• Title/Summary/Keyword: 원자로 공동

Search Result 70, Processing Time 0.025 seconds

Round Robin Analysis of Pressure-Temperature Limit Curve for Reactor Vessel (원자로 용기의 압력-온도 한계곡선 Round Robin 해석)

  • 정명조;이진호;박윤원;최영환;김영진
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.16 no.2
    • /
    • pp.153-163
    • /
    • 2003
  • Performed here is a comparative assessment study for the generation of the pressure-temperature limit curve of the reactor vessel. A round robin problem is proposed using the data available in Korea and all organizations interested in the generation of the pressure-temperature limit curve are invited. The problems consisting of 12 cases for cool-down are solved and their results are compared to generate a reference solution for the reference problem, which will be useful in the evaluation of the generation of the pressure-temperature limit curve in the future.

Spectroscopic studies of the high-pressure di-atomic sulfur vapor excited in an optical cavity by microwave discharges (마이크로파 방전에 의한 광학적 공동 안에서 고압 2-원자 황 증71의 분광학적 특성 연구)

  • 김진중;고정태;원동호;홍성호;김정원
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.114-115
    • /
    • 2002
  • 마이크로파 방전에 의한 고압 2-원자 황증기 (high-pressure di-atomic sulfur vapor)는 고효율(high luminous efficacy) 및 고연색성 (high color rendering index)의 백색 광원 (source of white light)으로 높이 평가되고 있다 [1]. 소위 무전극 황전등 (elec출odeless sulfur lamp, ESL)으로 알려진 이 발광원은 최고 효율이 173 lm/w 까지 시연되어 알려진 모든 인조 광원 중에서 가장 높은 효율을 보인 혁신적인 광원이다 [2]. (중략)

  • PDF

BETHSY 부분충수운전 실험 6.9c를 이용한 MELCOR 1.8.3 전산코드 평가

  • 조용진;김인구;이석호;이종인
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.629-634
    • /
    • 1998
  • 프랑스 CEA 실험장치인 BETHSY 실험설비에서 수행된 부분충수 운전에 대한 실험인 6.9c 실험에 대한 MELCOR 1.8.3 의 평가를 수행하였다. 이 연구는 OECD/NEA 국제공동연구인 ISP-38 로 수행되었다. 평가결과, MELCOR 1.8.3 은 부분충수운전시 잔열제거계통 상실에 대한 예측능력이 있고 원자로 냉각재계통압력, 노심수위 등 전반적으로 거동을 잘 모의하고 있다고 판단되었다. 그러나 민감도 분석에서 도출된 결론에 의하여 상간의 운동량 전달 및 Liquid Entrainment모델에 있어서 개선 필요성이 있는 것으로 평가되었다.

  • PDF

노벨물리학상 수상자들과 공동연구, 그리고 에피소드

  • Lee, Su-Jong
    • The Science & Technology
    • /
    • no.11 s.426
    • /
    • pp.38-45
    • /
    • 2004
  • 원자내부 미시세계와 우주바깥 거시세계의 기원을 밝혀내는 놀라운 노력의 결과로 지금까지 60여명의 고에너지물리학자에게 전체 노벨물리학상의 약 1/3이 수여되었다. 올해도 어김없이 노벨물리학상은 이 분야를 지목하여 폴리처(David H. Politzer), 그로스(David J. Gross), 윌첵(Frank Wilczek)에게 수여되었다.수상자들은 모두 필자와 공동연구를 했었고, 개인적으로 잘 알고 지내는 학자들이다. 이들의 업적을 에피소드와 함께 소개하고자 한다

  • PDF

한국천문연구원-제50호

  • 한국천문연구원
    • KASI NEWSLETTER
    • /
    • s.50
    • /
    • pp.1-4
    • /
    • 2005
  • 기숙사 신축공사 기공식/ 2004년 기관평가 결과 : '보통'/ 연구원 STRM 워크샵 개최/ 멕시코와 초대형 망원경 건설 공동협력 의향서 체결/ 대형망원경 건설 사업 과제 제안서 공모/ 삼국시대 일식도 발간/ 제13회 천체사진공모전 당선작 선정 및 시상/ 2005 별의 축제 개최/ 제2회 보현산별빛문화축제 개최/ 직원동정/ 학회동정/ 콜로키움/ 과학기술위성 1호 FIMS (원자외선 우주망원경) 관측

  • PDF

Prediction of Vortex Reducing Effect by a Peforated Baffle in the Inlet Plenum of a Research Reactor (연구용 원자로 유입 공동에서 다공형 차폐물에 의한 와류 감쇄효과 예측)

  • Park J. H.;Chae H. T.;Park C.;Kim H. I.
    • Journal of computational fluids engineering
    • /
    • v.9 no.2
    • /
    • pp.11-17
    • /
    • 2004
  • CFD analysis was performed to figure out flow behavior in the inlet plenum of new research reactor where coolant is injected to the flow tubes with the fuel assembly. The computation results showed that large-scale vortices are generated in the inlet plenum by flow stream injected from inlet pipe. These vortices are divided into small vortices and reversed their revolution. They may lead to flow-induced vibration of fuel assembly, moreover, which has been regarded as a cause of fretting wear of fuel assembly. Also there is an another important thing that average velocity of each flow-tube is uneven showing difference in maximum 18%. So it has been suggested that perforated baffle will be installed to prevent the formation of vortex in the inlet plenum. Two perforated baffles, one is flow skirt and the other is muffler type flow straightener, were proposed and their effect was evaluated using commercial CFD code, Fluent. According to CFD analysis for two perforated baffles, it was confirmed that both of them can prevent or reduce vortex formation in the inlet plenum and make average velocity of each flow tube more even.

Technological Features of Generation IV Nuclear Energy System (제4세대 원자력시스템의 기술적 특성)

  • Chung, Ik;Kim, Hyeon-Jun;Yang, Maeng-Ho;Oh, Geun-Bae
    • Proceedings of the Korea Technology Innovation Society Conference
    • /
    • 2003.11a
    • /
    • pp.359-368
    • /
    • 2003
  • In the early stage of 21th century, international nuclear society was on the active look out for new direction, and had a common recognition on the necessity of innovative reactor system. To achieve this purpose effectively, several international projects have been initiated for development of new nuclear energy systems that secure stable energy supply and have improved public acceptance, safety, and cost-effectiveness. In this study, status of international projects on future innovative nuclear energy systems and technology goals of future nuclear energy systems were surveyed, and the technological features of Generation IV nuclear energy system were described.

  • PDF

원자로 생산 방사성 핵종의 임상이용

  • 임상무
    • Nuclear Engineering and Technology
    • /
    • v.27 no.4
    • /
    • pp.635-643
    • /
    • 1995
  • 핵의학(nuclear medicine )이 란 방사성 및 안정 핵종의 동위원소표지 화합물을 인체에 투여하여, 관심장기의 형태 및 기능을 평가하여 해부학적 또는 생리학적 상태를 진단, 치료하는 의학의 전문 분야이다. 핵의학에 이용되던 방사성 핵종은 1960년대 까지만 해도 $^{131}$ I이 주였으나 1970년대 부터는 $^{99}$Mo -$^{99m}$ Tc 발생기와 $^{99m}$ TC으로 표지된 방사성의 약품이 활발히 이용되면서 $^{131}$ I을 대신하게 되었다. 원자로-생산핵종들의 특성은 중성자가 과잉이어 붕괴시 배타입자를 방출하는 점으로, 이것이 각종 질병의 치료에 이용되고 있다. 특히 각종 표시 화합물의 성질을 이용하여 원하는 부위에 방사선을 집중시킬 수 있음이 외부조사보다 유리한 점이다. 방사성핵종을 이용한 악성종양의 치료에 가장 성공적인 것은 분화된 갑상선 암환자에서 $^{131}$ I을 사용한 것이며, 갈색세포종 등에 $^{131}$ I-MIBG도 효과적이다. 악성종양의 골전이 치료에 베타선을 방출하는$^{32}$P, $^{186}$ Re, $^{153}$ Sm 등이 이용되었다. 종양의 동맥에 주입하여 세동맥이나 모세혈관에 걸리는 기름, 교진 또는 입자에 의한 치료에 $^{131}$ I-lipiodol, ethiodol, $^{32}$P 또는$^{90}$ Y흡사 ceramic resin 미소구 $^{166}$ Ho 유산중합체 미소구 등이 이용된다. $^{166}$ Ho, $^{198}$ Au, $^{32}$P, $^{90}$ Y, $^{169}$ Er, $^{186}$ Rc, $^{131}$ I, $^{211}$ At 등 의 방사성 핵종의 교질, 미소구 또는 단세포군 항체표지 형태로 직접 종양내 또는 공동이나 체강에 투여하는 치료법이 있다. 류마치스 관절염의 슬관절에 $^{165}$ Dy colloid를 주사하는 $^{166}$ Ho-MAA도 활발히 이용되고 있다.

  • PDF

부분충수 운전중 잔열제거계통 기능상실사고에 대한 CATHARE2 코드의 민감도 분석

  • 정영종;김원석;장원표
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.48-54
    • /
    • 1996
  • 가압경수로의 부분충수 운전중 RHR 계통의 기능상실시 사고완화를 위해 가압기 manway와 증기 발생기 출구공동 manway를 동시에 개방한 경우에 대한 실험결과를 CATHAHR2 코드를 이용하여 해석하였다. 해석을 통해 이 경우에 발생하는 물리적 현상을 이해하고 이와 같은 과도기에 대해 코드 예측능력을 평가하므로 써, 실제 원전에서 사고시 적절한 사고대응 방안을 강구하는데 참고가 될 수 있도록 해석적 근거를 제시하고자 한다. 연구결과 CATHARE2 코드는 실험을 통해 관측된 주요 물리적 현상들을 타당하게 예측하였으나, 가압기와 밀림관의 DP를 과대 예측하여 원자로 상부공동의 최대압력을 실험보다 약 7kPa 높게 예측하였다. 노심 노출시간도 노심에서 기포율 분포를 비현실적으로 예측하여 실험보다 약 500초 지연되었다. 실험과 코드의 모의결과를 통하여 노심 노출은 중력주입에 의한 냉각수 보충만으로 충분히 회복될 수 있음을 확인하였다. CATHARE2 코드는 비록 상세한 현상들에 대해 다소 불확실성을 내포하였으나, 전반적인 거동분석에는 타당한 것으로 판단된다. CATHARE 코드는 노심에서 계면 마찰력을 줄임으로써 노심의 차압을 개선할 수 있었고, guide 튜브의 위치를 고온관 중심선과 일치시켜 guide 튜브내 액체의 hold-up 기간을 개선할 수 있었으며, 가압기의 계면 마찰력을 증가시켜서 밀림관에서 "plug and clearing" 현상을 모의할 수 있었다.모의할 수 있었다.

  • PDF

Nuclear Hydrogen Production Technology Development Using Very High Temperature Reactor (초고온가스로를 이용한 원자력수소생산 기술개발)

  • Kim, Yong-Wan;Kim, Eung-Seon;Lee, Ki-yooung;Kim, Min-hwan
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.4
    • /
    • pp.299-305
    • /
    • 2015
  • Nuclear hydrogen production technology is being developed for the future energy supply system. The sulfur-iodine thermo-chemical hydrogen production process directly splits water by using of the heat generated from very high temperature gas-cooled reactor, a typical Generation IV nuclear system. Nuclear hydrogen key technologies are composed of VHTR simulation technology at elevated temperature, computational tools, TRISO fuel, and sulfur iodine hydrogen production technology. Key technology for nuclear hydrogen production system were developed and demonstrated in a laboratory scale test facility. Technical challenges for the commercial hydrogen production system were discussed.