• Title/Summary/Keyword: 원자력학회지

Search Result 947, Processing Time 0.022 seconds

Field Application of Phased Array Ultrasonic Testing for Structural Weld Overlay on Dissimilar Welds of Pressurizer Nozzles (가압기 노즐 이종금속 용접부의 구조적 오버레이 용접부에 대한 위상배열 초음파기법의 현장 적용)

  • Kim, Jin-Hoi;Kim, Yongsik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.4
    • /
    • pp.268-274
    • /
    • 2015
  • Weld overlay was first used in power plants in the US in the early 1980s as an interim method of repairing the welds of flawed piping joints. Weld overlaid piping joints in nuclear power plants must be examined periodically using ultrasonic examination technology. Portable phased array ultrasonic technology has recently become available. Currently, the application of preemptive weld overlays as a mitigation technique and/as a method to improve the examination surface condition for more complex configurations is becoming more common. These complex geometries may require several focused conventional transducers for adequate inspection of the overlay, the original weld, and the base material. Alternatively, Phased array ultrasonic probes can be used to generate several inspection angles simultaneously at various focal depths to provide better and faster coverage than that possible by conventional methods. Thus, this technology can increase the speed of examinations, save costs, and reduce radiation exposure. In this paper, we explain the general sequence of the inspection of weld overlay and the results of signal analysis for some PAUT (phased array ultrasonic testing) signals detected in on-site inspections.

Separation for the Determination of $^{59/63}Ni$ in Radioactive Wastes (방사성 폐기물 내 $^{59/63}Ni$ 정량을 위한 분리)

  • Lee, Chang-Heon;Jung, Kie-Chul;Choi, Kwang-Soon;Jee, Kwang-Young;Kim, Won-Ho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.4
    • /
    • pp.309-317
    • /
    • 2005
  • A study on the separation of $^{99}Tc,\;^{94}Nb,\;^{55}Fe,\;^{90}Sr\;and\;^{59/63}Ni$ in various radioactive wastes discharged from nuclear power plants has been performed for a use in their quantification which is indispensible for the evaluation of the radionuclide inventory Ni was recovered along with Ca, Mg, Al, Cr, Ti, Mn, Ce, Na, K, and Cu through the sequential separation procedure of Re(as a surrogate of $^{99}Tc$), Nb, Fe and Sr by anion exchange and Sr-Spec extraction chromatography. In this research, chemical separation of Ni from the co-existing elements was investigated by cation exchange and Ni-Spec extraction chromatography. Precipitation behaviour of Ni and the co-existing elements with dimethylglyoxime(DMG) was investigated in ammonium $citrate/ethanol-H_2O$ and tartaric $acid/acetone-H_2O$ in order to purify separated Ni fractions and to prepare $^{59/63}Ni$ source for the radioactivity measurement using a gas proportional counter. Recovery of Ni separated through ion exchange chromatographic separation procedure was $92.1\%$ with relative standard deviation of $0.9\%$. In addition, recovery of Ni with DMG in the tartaric $acid/acetone-H_2O$ was $85.6\%$ with relative standard deviation of $1.9\%$.

  • PDF

Study of morphology on the Oxidation and the Annealing of High Burn-hp $UO_2$ Spent Fuel (고연소도 사용후 핵연료의 가열산화와 고온가열을 통한 미세조직 변화고찰)

  • Kim Dae Ho;Bang Jae Geun;Yang Yong Sik;Song Keun Woo;Lee Hyung Kwon;Kwon Hyung Moon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.4
    • /
    • pp.301-307
    • /
    • 2005
  • The morphology of the high burnup $UO_2$ spent fuel, which was oxidized and annealed in a PIA (Post Irradiation Annealing) apparatus, has been observed. The high burnup fuel irradiated in Ulchin Unit 2, average rod burnup 57,000 MWd/tU, was transported to the KAERI's PIEF. The test specimen was used with about 200 mg of the spent $UO_2$ fuel fragment of the local burnup 65,000 MWd/tU. This specimen was annealed at $1400^{\circ}C$ for 4hrs after the oxidation for 3hrs to grain boundary using the PIA apparatus in a hot-cell. In order to oxidize the grain boundary, the oxidation temperature increased up to $500^{\circ}C$ and held for 3hrs in the mixed gas (60 ml He and 100 ml STD-air) atmosphere. The amount of 85Kr during the whole test process was measured to know the fission gas release behavior using the online system of a beta counter and a gamma counter. The detailed micro-structure was observed by a SEM to confirm the change of the fuel morphology after this test. As the annealing temperature increased, the fission products were observed to move to the grain surface and grain boundary of the $UO_2$ matrix. This specimen was re-structured through the reduction process, and the grain sizes were distributed from 5 to $10\;{\mu}m$.

  • PDF

Characteristics of Vitrification Process for Mixture of Simulated Radioactive Waste Using Induction Cold Crucible Melter (유도가열식 저온용융로를 이용한 혼합모의 방사성폐기물의 유리화 공정 특성)

  • 김천우;양경화;박병철;박승철;황태원;박종길;신상운;하종현;송명재
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.3
    • /
    • pp.165-174
    • /
    • 2004
  • In order to simultaneously vitrify the ion exchange resin(IER) and combustible dry active waste(DAW) generated from Korean nuclear power plants, a vitrification pilot test was conducted using an induction cold crucible melter(CCM) . The energy necessary for startup of the glass using a Ti-ring was evaluated as about 290 kWh. The power supplied from a high frequency generator to melt the glass properly was ranged from 160 to 190 kW without any interruption. When the mixture of the IER and DAW was fed into the CCM, the concentration of CO was lowered up to 1/40 compared to feeding the IER solely. It may be caused by the DAW which can produce about 1.8 times higher heat compared to the IER. When the swelling phenomenon occurred in the glass melt, the concentration of $NO_2$, oxidizing gas, was higher than NO, reducing gas. Total feed amounts of the IER and DAW were 368 and 751 kg, respectively. And then, about 74 of volume reduction factor was achieved.

  • PDF

Removal Efficiency of Organic Iodide on Silver Ion-Exchanged Yeolite and TEDA-AC at High Temperature Process (고온공정에서 은교환 제올라이트 및 TEDA 첨착활성탄의 유기요오드 제거성능)

  • 최병선;박근일;김성훈;윤주현;배윤영;지성균;양호연;유승곤
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.1 no.1
    • /
    • pp.65-72
    • /
    • 2003
  • Adsorption and desorption characteristics of methyl iodide at high temperature conditions up to 25$0^{\circ}C$ by TEDA-impregnated activated carbon and silver-ion exchanged zeolite(AgX-10), which are used for radioiodine retention in nuclear facility, were experimentally evaluated. In the range of temperature from 3$0^{\circ}C$ to 25$0^{\circ}C$, the adsorption capacity of base activated carbon decreased sharply with increasing temperature but that of TEDA-impregnated activated carbon showed higher value even at high temperature ranges. Especially, the residual amount of methyl iodide after desorption on TEDA-AC represented 30% lower value than that on AgX-10. However, it can be used as an adsorbent for the removal of methyl iodide up to 15$0^{\circ}C$ if it is preventing explosion by Ignition. The breakthrough curves of methyl iodide in the fixed bed packed with AgX-10 uP to 40$0^{\circ}C$ were compared upon the effects of bed temperatures, bed depth and input concentration of methyl iodide. Removal mechanism of methyl iodide on AgX-10 was proposed, based on the analysis of by-product gas generated from adsorption reaction.

  • PDF

Evaluation on the Radiological Shielding Design of a Hot Cell Facility (핫셀시설의 방사선 안전성 평가)

  • 조일제;국동학;구정회;정원명;유길성;이은표;박성원
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.1
    • /
    • pp.1-11
    • /
    • 2004
  • The hot cell facility for research activities related to the lithium reduction of spent fuel, which is designed to permit safe handling of source materials with radioactivity levels up to 1,385 TBq, is planned to be built. To meet this goal, the facility is designed to keep gamma and neutron radiation lower than the recommended dose-rate in normally occupied areas. The calculations peformed with QAD-CGGP and MCNP-4C are used to evaluate the proposed engineering design concepts that would provide acceptable dose-rates during a normal operation in hot cell facility. The maximum effective gamma dose-rates on the surfaces of the facility at operation area and at service area calculated by QAD-CGGP are estimated to be $2.10{\times}10^{-3}, 2.97{\times}10^{-3} and 1.01{\times}10{-1}$ mSv/h, respectively. And those calculated by MCNP-4C are $1.60{\times}10^{-3}, 2.99{\times}10^{-3} and 7.88{\times}10^{-2}$ mSv/h, respectively, The dose-rates contributed by neutrons are one order of magnitude less than that of gamma sources. Therefore, it is confirmed that the radiological design for hot cell facility satisfies the Korean criterion of 0.01 mSv/h for the operation area and 0.15 mSv/h for the service (maintenance) area.

  • PDF

A Study on the Clearance Level(draft) for the Steel Scrap from the KRR-1 & 2 Decommissioning (연구로 1,2호기 해체 철재폐기물의 규제해제농도기준(안) 도출을 위한 연구)

  • 홍상범;이봉재;정운수
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.1
    • /
    • pp.60-67
    • /
    • 2004
  • The exposure dose form recycling of a large amount of the steel scrap from the KRR-1&2 decommissioning activities was evaluated, and also the clearance level(draft) was derived. The maximum individual dose and collective dose were evaluated by modifying internal dose conversion factor which was based on the concept of effective dose in ICRP 60, applied to the RESRAD-RECYCLE ver 3.06 computing code, IAEA Safety Series 111-P-1.1 and NUREG-1640 as the assessment tool. The result of assessment for individual dose and collective dose is 23.9 $\mu$Sv per year and 0.11 man$.$Sv per year respectively. The clearance levels were ultimately determined by extracting the most conservative value form the results of the generic assessment and specific assessment methodologies. The result of clearance level for radionuclides( $Co^{60}$ , C $s^{l37}$) is less than 1.14${\times}$10$^{-1}$ Bq/g to comply with the clearance criterion(maximum individual dose : 10 $\mu$Sv per year, collective dose : 1 man$.$Sv per year) provided for Korea Atomic Energy Act and relevant regulations.s.

  • PDF

Contaminative Influence of Beef Due to the Inhalation of Air and the Ingestion of Soil of Livestock from an Acute Release of Radioactive Materials (원자력시설의 사고시 가축의 공기 흡입과 토양 섭취가 육류의 방사능 요염에 미치는 영향)

  • 황원태;김은한;서경석;정효준;한문희
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.3
    • /
    • pp.181-188
    • /
    • 2004
  • The contaminative influence of beef due to the inhalation of air and the ingestion of soil of livestock, both of which are dealt with as minor contaminative pathways in most radioecological models but may not be neglected, was comprehensively investigated with the improvement of the Korean food chain model DYNACON. As the results, it was found that both pathways can not be neglected at all in the contamination of beef in the case of an accidental release during the non-grazing period of livestock. The ingestion of soil was more influential in the contamination of beef than the inhalation of air over most time following an release. If precipitation is encountered during an accidental release, contaminative influence due to the ingestion of soil was far greater compared with the cases of no precipitation. This fact was more distinct for a long-lived radionuclide $^{l37}Cs$ than a short-lived radionuclide $^{131}I$ (elemental iodine). Compared with the results for milk performed prior to this study, the contaminative pathways due to the inhalation of air and the ingestion of soil were more important in beef because of longer biological half-lives. On the other hand, in the case of an accidental release during the grazing period of livestock, radioactive contamination due to the ingestion of pasture was dominant irrespective of the existence of precipitation during an accidental release. It means that contaminative influence due to the inhalation of air and the ingestion of soil is negligible, like the cases of milk.

  • PDF

An Evaluation on the Radiation Shielding of the Radwaste Drum Assay Facility (방사성폐기물드럼 핵종재고량 평가시설 구축에 따른 방사선차폐 영향평가)

  • Ji, Young-Yong;Kwak, Kyung-Kil;Hong, Dae-Seok;Shon, Jong-Sik
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.10 no.2
    • /
    • pp.117-123
    • /
    • 2012
  • In order to dispose of the LILW(low and intermediate level radioactive waste) stored at KAERI, the radwaste drum assay system will be introduced to evaluate the radioisotopes inventory of stored drums. At present, the construction project of the dedicated assay facility to operate it and carry out routine maintenance of that equipment has been conducting at the radwaste treatment facility. Since that facility will be constructed in front of a 1st radwaste storage facility as well as the radwaste drums to be assayed and the transmission source in the radwaste drum assay system are in that facility, they could act as the radioactive sources and then, would affect the dose rate at the inside and the outside of the facility. Therefore, the radiation shielding should be evaluated through the concrete wall near to the radioactive sources whether the wall thickness is sufficient against the regulations. In this study, the radiation safety for the concrete wall around the radiation controlled area in the radwaste drum assay facility was evaluated by the MCNP code. From the evaluation results, the thickness of those concrete walls which are under consideration of about 30 cm was enough to shield the radiation from the radioactive sources.

Radionuclides Transport from the Hypothetical Disposal Facility in the KURT Field Condition on the Time Domain (KURT 부지 환경에 위치한 가상의 처분 시설에서 누출되는 방사성 핵종의 이동을 Time Domain에서 해석하는 방법에 관한 연구)

  • Hwang, Youngtaek;Ko, Nak-Youl;Choi, Jong Won;Jo, Seong-Seock
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.10 no.4
    • /
    • pp.295-303
    • /
    • 2012
  • Based on the data observed and analyzed on a groundwater flow system in the KURT (KAERI Underground Research Tunnel) site, the transport of radionuclides, which were assumed to be released at the supposed position, was calculated on the time-domain. A groundwater pathway from the release position to the surface was identified by simulating the groundwater flow model with the hydrogeological characteristics measured from the field tests in the KURT site. The elapsed time when the radionuclides moved through the pathway is evaluated using TDRW (Time Domain Random Walk) method for simulating the transport on the time-domain. Some retention mechanisms, such as radioactive decay, equilibrium sorption, and matrix diffusion, as well as the advection-dispersion were selected as the factors to influence on the elapsed time. From the simulation results, the effects of the sorption and matrix diffusion, determined by the properties of the radionuclides and underground media, on the transport of the radionuclides were analyzed and a decay chain of the radionuclides was also examined. The radionuclide ratio of the mass discharge into the surface environment to the mass released from the supposed repository did not exceed $10^{-3}$, and it decreased when the matrix diffusion were considered. The method used in this study could be used in preparing the data on radionuclide transport for a safety assessment of a geological disposal facility because the method could evaluate the travel time of the radionuclides considering the transport retention mechanism.