• 제목/요약/키워드: 원심임펠러

검색결과 144건 처리시간 0.025초

기액 이상류시의 스크류식 원심펌프의 압력분포 (Pressure Distributions of a Screw-type Centrifugal Pump Operating in Air-Water Two-Phase Flow)

  • 김유택;최민선;이영호
    • 한국유체기계학회 논문집
    • /
    • 제4권3호
    • /
    • pp.39-45
    • /
    • 2001
  • It is reported recently that the pump head deterioration near the best efficiency point, from single-phase flow to the choke due to air entrainment became less in a screw-type centrifugal pump than in a general centrifugal pump. Moreover, at a narrow tip clearance, the pump head became partially higher in two-phase flow than that in single-phase flow. However, the internal pressure fluctuations on this pump due to air entrainment have not been studied yet. For that reason, we have examined the influences of void fraction, flow coefficient and impeller tip clearance on pressure fluctuations in the casing. The void fraction became larger, the influence of tip clearance on pressure distribution became less.

  • PDF

원심 압축기 베인 디퓨져내 비정상 유동의 수치해석적 연구 (Numerical Study on the Unsteady Flow in the Vaned Diffuser of Centrifugal Compressor)

  • 황성목;한화택;김원갑
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.113-119
    • /
    • 2001
  • Interaction of flow through an Impeller and a Vaned Diffuser in Centrifugal Compressor was investigated using the 3-dimensional Wavier-Stokes solution method. To consider the interaction effect of impeller and vaned diffuser, Inlet boundary conditions are imposed with the results of the steady calculation of the impeller and rotates with time. The results have been compared to steady computation results and experiment. From this, it is discussed about the compatability of the method and the advantage and disadvantage of the steady calculation.

  • PDF

상용 CFD코드를 이용한 원심펌프 임펠러의 성능해석 (Performance Analysis of the Centrifugal Pump Impeller Using Commercial CFD Code)

  • 최영석;이용갑;홍순삼;강신형
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.305-311
    • /
    • 2000
  • A commercial CFD code is used to compute the 3-D viscous flow field within the impeller o( a centrifugal pump. Several preliminary numerical calculations are carried out to determine the influence of the parameters such as the grid systems, the numerical schemes, the turbulence models and the shape of the vaneless diffusers at the design flow rate. The results of the preliminary study are used for the calculation of the off-design flow conditions. The circumferentially averaged results such as the radial and tangential velocities, the exit flow angle, the slip factor, the static pressure and the total pressure are compared with the experimental data at the impeller exit to discuss the influence of the prescribed parameters.

  • PDF

상용코드를 이용한 원심펌프 임펠러 유동평가 (Flow Evaluations of Centrifugal Pump Impeller Using Commercial Code)

  • 심창열;홍순삼;강신형
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.285-292
    • /
    • 2000
  • Numerical calculation is applied to centrifugal pump at design condition by using commercial code STAR-CD and Tascflow, and these results are compared with experimental data at impeller outlet. Numerical analysis is also performed by changing turbulence model and discretization scheme at design condition using Tascflow. Turbulence model and discretization scheme used to Tascflow are k-$\epsilon$, k-$\omega$ turbulence model and upwind, modified linear profile scheme. W;th the same turbulence model and discretization scheme, two results of STAR-CD and Tascflow are very similar. But there is significant difference in numerical results near hub and shroud of impeller with different kinds of turbulent model and discretization scheme at design condition. And with k- $\omega$ turbulence model and modified linear profile scheme, it is showed that numerical results are very similar to experimental results of impeller outlet

  • PDF

원심압축기 임펠러의 Blockage와 Slip 특성에 관한 수치연구 (Numerical Study on Blockage and Slip Characteristics of Centrifugal Compressor Impellers)

  • 오종식
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.236-244
    • /
    • 2000
  • As the second part of the author's study, the aerodynamic blockage and the slip factor of 8 centrifugal compressor impellers are investigated, when the flow rate is changed from numerical stall to choke, using three-dimensional Navier-Stokes analysis results. Based on all the exit blockage distributions, an improved model equation with two adjusting coefficients is developed for the use in design processes with the agile engineering purpose. A popular expression of constant slip factors, the Wiesner's equation, cannot be applied in design processes when more accurate prediction is strongly required at design and off-design points. Slip factor variation is found to be also influenced by the blade loadings at midspan. When the flow rate is changed, a pattern of the slip factor variations is assumed to be a simple form which can be explained using midspan blade loading distributions.

  • PDF

압력보정법을 이용한 8개의 원심압축기 임펠러 CFD의 적용 연구 (Application of Pressure Correction Method to CFD Work for 8 Centrifugal Compressor Impellers)

  • 오종식;노수혁;현용익
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.226-235
    • /
    • 2000
  • Two representative finite volume methods, i.e., the time marching method and the pressure correction method, were applied to 8 centrifugal compressor impeller flows, with low to very high level of pressure ratio, among which 7 impellers' experimental performance is given in the open literature. The present study is focused on the prediction differences from both methods, developed by the authors, in the pressure correction method's point of view. In all cases, the time marching method gives a satifactory solution, but the pressure correction method does not. Up to about $18\%$ less level of total-to-total pressure ratio is predicted by the pressure correction method as the level of the impeller pressure ratio increases up to about 10. The drop of total pressure ratio is caused by the underestimation of static pressure rise which seems to be attributed to inappropriate linearization and discretization of the pressure/density coupling terms in the pressure correction equation.

  • PDF

반응면기법을 이용한 원심압축기 최적설계 (OPTIMIZATION OF A CENTRIFUGAL COMPRESSOR IMPELLER AND DIFFUSER USING A RESPONSE SURFACE METHOD)

  • 김세미;박준영;안국영;백제현
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2007년도 추계 학술대회논문집
    • /
    • pp.92-99
    • /
    • 2007
  • In this paper, optimization of the vaned centrifugal compressor was carried out at a given mass flow rate condition. Firstly, impeller optimization was conducted using response surface method (RSM) which is one of optimization methods. After the optimization of the impeller was completed, diffuser optimization was performed with the optimized impeller. In these processes, Navier-Stokes solver was used to calculate the flow inside the centrifugal compressor. And the optimization is performed with Box-Behnken design method which is efficient for fitting second-order response surfaces to reduce the number of calculations required. As a result, compared with the reference model, the efficiency and the pressure ratio of the optimized impeller and diffuser are found to be increased. The performance at off-design conditions is presented.

  • PDF

실험계수를 이용한 원심 펌프의 설계와 해석 (Design and Analysis of Centrifugal Pump using Experimental Factor)

  • 임효남;김진영;양창조;이영호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.434-440
    • /
    • 2000
  • This study is focused on the performance prediction and design of the centrifugal pump with optimum shape. Design and analysis of centrifugal pump rely on experience of designer due to many fluid mechanical and geometrical variables. In this study, a design method was developed with experimental factors and analysed the method by comparition with 2nd-order vortex panel method. Impeller is the most important component affecting the performance of the centrifugal pump. The predicted total head for three cases, of which designs were determined by this method, agrees well with a particular commercial pump. This study shows that satisfactory performance of an optimal pump shape can be obtained through the automatic design routine.

  • PDF

원심형 터보기계의 볼류트형상 변화에 따른 유동특성에 관한 실험적 연구 (An Experimental Study on Flow Characteristics of Centrifugal Turbomachinery According to The Volute Shape Change)

  • 박대송;전경준;주원구
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.623-626
    • /
    • 2002
  • The object of present study is to find the flow characteristics of centrifugal turbomachinery according to the volute shape change. The experiments were carried out for two model; volute-A designed by free vortex conditions and volute-B designed for use in high mass flow rate conditions using the volute-A test results, Flow measurements were taken in shrouded impeller with 12 backward type blades by using a five-hole pilot-tube and carried out in 4 flow rate, $Q/Q_d\;=0,43,\;1.0,\;1.27,\;1,47$, respectively, For volute-B, we found that pressure distribution was more uniform at high flow rate and from $Q/Q_d\;:\;0,43\;to\;Q/Q_d\;:\;1,20$, losses decreased and efficiency increased compare with volute-A.

  • PDF

CFD에 의한 원심펌프 임펠러 성능해석에 관한 연구 (A Study on a Perfomance Analysis of the Centrifugal Pump Impeller using CFD)

  • 남구만;모장오;강신정;임효남;이영호
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.89-94
    • /
    • 2002
  • A commercial CFD code is used to calculate the 3-D viscous flow field within the centrifugal pump impeller. Design conditions are changed by impeller inlet(9.3mm, 12.2mm) and outlet breadth(6.65mm, 6.85mm). Numerical calculation was performed by changing flow rate from 8 to 26m$^{3}$/hr. Computation results shows that total head is increased at the larger inlet and outlet breadth than the others. And when the flow rate is increasing, the total head was decreased. The maximum efficiency of pump is shown at the design flow rate(16m$^{3}$/hr). In this study shows that the calculated results are good agreements with analysis results of design condition.

  • PDF