• Title/Summary/Keyword: 원격진단 시스템

Search Result 249, Processing Time 0.021 seconds

Implementation of PACS using PDA System on Medical Images (PDA기반 의료영상의 전송시스템 구현)

  • Ji, Yeon-Sang;Dong, Kyung-Rae;Kim, Chang-Bok
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.4
    • /
    • pp.247-253
    • /
    • 2009
  • PACS(Picture archiving communication system) is a system that enables medical images such as X -ray, CT, MRI, PET to be stored electronically viewed on computer screens so that doctors and other authorized people can access search the information as needed. But if they are not in hospital area for example on holiday or at night, that are not able to access the PACS system instantly. We have to solve this problem for more efficient patient care. So we try to suggest a method that use the PDA system that wireless LAN and CDMA cellular phone are equipped. This system may help to access easier to PACS system regardless of the location and can also attribute the development of telemedicne.

A User Driven Adaptable Bandwidth Video System for Remote Medical Diagnosis System (원격 의료 진단 시스템을 위한 사용자 기반 적응 대역폭 비디오 시스템)

  • Chung, Yeongjee;Wright, Dustin;Ozturk, Yusuf
    • Journal of Information Technology Services
    • /
    • v.14 no.1
    • /
    • pp.99-113
    • /
    • 2015
  • Adaptive bitrate (ABR) streaming technology has become an important and prevalent feature in many multimedia delivery systems, with content providers such as Netflix and Amazon using ABR streaming to increase bandwidth efficiency and provide the maximum user experience when channel conditions are not ideal. Where such systems could see improvement is in the delivery of live video with a closed loop cognitive control of video encoding. In this paper, we present streaming camera system which provides spatially and temporally adaptive video streams, learning the user's preferences in order to make intelligent scaling decisions. The system employs a hardware based H.264/AVC encoder for video compression. The encoding parameters can be configured by the user or by the cognitive system on behalf of the user when the bandwidth changes. A cognitive video client developed in this study learns the user's preferences (i.e. video size over frame rate) over time and intelligently adapts encoding parameters when the channel conditions change. It has been demonstrated that the cognitive decision system developed has the ability to control video bandwidth by altering the spatial and temporal resolution, as well as the ability to make scaling decisions

Reliability Model for u-Health SW's BMT (u-Health SW의 BMT를 위한 신뢰성 모델)

  • Chung, Sam-Sool;Yang, Hae-Sool
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.5
    • /
    • pp.80-89
    • /
    • 2010
  • u-Health refers to "Always, ubiquitously" prevention against disease, diagnosis, medical treatment service that can receive treatment even if patient does not visit hospital as abbreviated word of ubiquitous and health. U-Health transmits in individual's living body sign and measuring of health information and health information system that is consisted of process of analysis and feedback transmiting and measure individual's living body signal and health information and health proprietary company or medical institution operates. If analyze pattern to information that health information system is transmited, health care officer or chief physician means that offer healthcare and medical treatment service to remote about target customer. Wish to present authoritativeness model for u-Health's inside and outside of the country same native place and u-Health's BMT in this research.

The Development of X-ray Unit of Remote Emergency medical System (원격응급시스템에 적합한 X-ray 장치 개발)

  • Cho, Dong-Heon;Koo, Kyung-Wan;Yang, Hae-Sool;Han, Man-Seok;Han, Sang-Ok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.49-54
    • /
    • 2006
  • The X-ray unit developed by this study is to diagnose emergency cases which is too far from a hospital and to classify the patients. We have to use the X-ray in a ambulance or the scene of an accident where we cannot use the AC220 outlet because of the distance from a hospital as well. The X-ray unit developed has a characteristics as follows. First of all, as the unit has a condenser in itself where there is no electric supply, we can use the X-ray inspector in a mountain area or a island. Second, we can detect by digital detector the information taken by X-ray from DC 12[V] electricity and store as a form of file. A control circuit can secure the reliability of the X-ray unit by using the Pic16F84A X-ray and provide various functions. The X-ray unit which suits remote emergency system can be efficiently used for the emergent cases who is too far from a doctor and a hospital or in the situation where it is difficult to diagnose, transcribe and treat simultaneously.

A Customized Cancer Radiation Treatment Planning Simulation (ccRTPs) System via Web and Network (웹과 네트워크 기술을 이용한 환자 맞춤식 암치료 계획 시뮬레이션 시스템)

  • Khm, O-Yeon
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.144-152
    • /
    • 2006
  • The telemedicine using independent client-server system via networks can provide high quality normalized services to many hospitals, specifically to local/rural area hospitals. This will eventually lead to a decreased medical cost because the centralized institute can handle big computer hardware systems and complicated software systems efficiently and economically, Customized cancer radiation treatment planning for each patient Is very useful for both a patient and a doctor because it makes possible for the most effective treatment with the least possible dose to patient. Radiation planners know that too small a dose to the tumor can result in recurrence of the cancer, while too large a dose to healthy tissue can cause complications or even death. The best solution is to build an accurate planning simulation system to provide better treatment strategies based on each patient's computerized tomography (CT) image. We are developing a web-based and a network-based customized cancer radiation therapy simulation system consisting of four Important computer codes; a CT managing code for preparing the patients target data from their CT image files, a parallel Monte Carlo high-energy beam code (PMCEPT code) for calculating doses against the target generated from the patient CT image, a parallel linear programming code for optimizing the treatment plan, and scientific data visualization code for efficient pre/post evaluation of the results. The whole softwares will run on a high performance Beowulf PC cluster of about 100-200 CPUs. Efficient management of the hardware and software systems is not an easy task for a hospital. Therefore, we integrated our system into the client-sewer system via network or web and provide high quality normalized services to many hospitals. Seamless communication with doctors is maintained via messenger function of the server-client system.

  • PDF

The Simulation and Research of Information for Space Craft(Autonomous Spacecraft Health Monitoring/Data Validation Control Systems)

  • Kim, H;Jhonson, R.;Zalewski, D.;Qu, Z.;Durrance, S.T.;Ham, C.
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.2 no.2
    • /
    • pp.81-89
    • /
    • 2001
  • Space systems are operating in a changing and uncertain space environment and are desired to have autonomous capability for long periods of time without frequent telecommunications from the ground station At the same time. requirements for new set of projects/systems calling for ""autonomous"" operations for long unattended periods of time are emerging. Since, by the nature of space systems, it is desired that they perform their mission flawlessly and also it is of extreme importance to have fault-tolerant sensor/actuator sub-systems for the purpose of validating science measurement data for the mission success. Technology innovations attendant on autonomous data validation and health monitoring are articulated for a growing class of autonomous operations of space systems. The greatest need is on focus research effort to the development of a new class of fault-tolerant space systems such as attitude actuators and sensors as well as validation of measurement data from scientific instruments. The characterization for the next step in evolving the existing control processes to an autonomous posture is to embed intelligence into actively control. modify parameters and select sensor/actuator subsystems based on statistical parameters of the measurement errors in real-time. This research focuses on the identification/demonstration of critical technology innovations that will be applied to Autonomous Spacecraft Health Monitoring/Data Validation Control Systems (ASHMDVCS). Systems (ASHMDVCS).

  • PDF

Research of Remote Inspection Method for River Bridge using Sonar and visual system (수중초음파와 광학영상의 하이브리드 시스템을 이용한 교각 수중부 원격점검 기법 연구)

  • Jung, Ju-Yeong;Yoon, Hyuk-Jin;Cho, Hyun-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.330-335
    • /
    • 2017
  • This study applied SONAR(Sound Navigation And Ranging) to the inspection and evaluation of underwater structures. Anactual river bridge was chosen for inspection and evaluation. SONAR and an optical camera were operated together to analyze the underwater image of the bridge. SONAR images were obtained by various methods to remove the environmental variables from the field experiment, and it was confirmed that the reliability of detecting damaged areas on piers was decreased when using SONAR alone. The SONAR equipment and the optical camera can be used simultaneously to overcome the limitations of SONAR in inspecting underwater structures.These results can be used as basic data for the development of similar technologies for underwater structure inspection.

Development of Wireless Measurement System for Bridge Using PDA and Fiber Optical Sensor (PDA와 광섬유 센서를 이용한 교량의 무선계측 시스템 개발)

  • Kwak, Kae-Hwan;Hwang, Hae-Sung;Jang, Hwa-Sup;Kim, Woo-Jong;Kim, Hoi-OK
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.1 s.53
    • /
    • pp.88-96
    • /
    • 2009
  • This study proposes a wireless measurement system that is a new safety management system by using an FBG sensor and a PDA. The sensor part has many advantages of implementing a wireless measurement system, and the study emploies an FBG-LVDT sensor, FBG-STRAIN sensor, FBG-TEMP sensor, and FBG-ACC sensor, using FBG sensors. Also, the study show a configuration of a signal process system for operating a wireless transmission system of FBG sensors applied to the signal process system, and engrafted the cutting edge information technology industry in order to display from a remote distance using a PDA. In order to verify the applicability of the developed FBG sensors and wireless measurement monitoring system to the field, their accuracy, and usability, the study has conducted a static and dynamic test to a bridge in the field. The study made an assessment of service for the vibration of the bridge by applying dynamic data measured by an FBG-LVDT sensor and FBG-ACC sensor to Meister's curve and prepared methods for assessing the vibration of the bridge by proposing a standard of vibration limitation given the service of vibration of the bridge. As a follow up for this study, it would be necessary to set up an overall model for the standard of service assessment established in this study.

Urothelial Carcinoma of the Bladder: Radiologic Perspective (방광 요로상피세포암: 영상의학적 관점)

  • Dong Won Kim;Seong Kuk Yoon;Sang Hyeon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1033-1052
    • /
    • 2021
  • Bladder cancer is a relatively common cancer type, with a high recurrence rate, that can be often encountered in the imaging study. Accurate diagnosis and staging have a significant impact on determining treatment and evaluating prognosis. Bladder cancer has been evaluated by transurethral resection of bladder tumor for clinical staging and treatment, but it is often understaged when compared with final pathologic result by radical cystectomy. If the location, size, presence of muscle invasion, lymph node metastasis, distant metastasis, and presence of upper urinary tract cancer can be accurately diagnosed and evaluated in an imaging study, it can be treated and managed more appropriately. For an accurate diagnosis, radiologists who evaluate the images must be aware of the characteristics of bladder cancer as well as its types, imaging techniques, and limitations of imaging studies. Recent developments in MRI with functional imaging have improved the quality of bladder imaging and the evaluation of cancer. In addition, the Vesical Imaging Reporting and Data System was published to objectively assess the possibility for muscle invasion of cancer. Radiologists need to know the types of bladder cancer treatment and how to evaluate the changes after treatment. In this article, the characteristics of bladder urothelial carcinoma, various imaging studies, and findings are reviewed.

A Centralized Monitoring System for Infant Incubators Using Bluetooth (블루투스를 이용한 신생아 인공 보육기의 중앙감시 장치)

  • Kim Joo-Sik;Ahn Hyun-Sik;Jeong Gu-Min
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.7 no.1
    • /
    • pp.33-37
    • /
    • 2006
  • In this paper, we present a centralized monitoring system for infant incubator using Bluetooth. Conventional monitoring systems for incubators require large space and wire connection, which causes the spatial restrictions. To overcome this disadvantage, centralized monitoring system is proposed for infant incubators using Bluetooth. The implemented system consists mainly of transmission systems and receiver systems. There are temperature sensors, humidity sensors, ECG measurement units and Bluetooth modules in the transmission systems. For temperature, humidity and ECG data, the transmission systems acquire them from the measuring modules in the incubator and transmits the signals using Bluetooth. In the receiver system, users can see the status of the infant by accessing the central monitoring host computer. That is, one can monitor the information on the temperature and the humidity in the incubator and Infant's ECG without dependence to a conventional bulky system. Also, the system manager in the receiver system can maintain centralized monitoring of the situations in all incubators and infant. The developed system will be useful in remote diagnosis of infant incubator In various environments.

  • PDF