• Title/Summary/Keyword: 워터 젯

Search Result 77, Processing Time 0.025 seconds

Effects of Traverse Speed on Dimensional Error in Abrasive Water-Jet (입자 워터 젯의 이송속도가 공작물의 치수정밀도에 미치는 영향)

  • 곽재섭;하만경
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.3
    • /
    • pp.1-7
    • /
    • 2004
  • Abrasive water-jet(AWJ) machining can cut various materials such as metal, glass and plastics. However, the AWJ machining has some troubles including kerf, rounding and side taper. In this study, we experimently investigated the correlation between the traverse speed of the abrasive water-jet and the dimensional error of the workpiece according to the thickness and the types of the material. The specimen was the stainless steel and the mild steel and the predetermined contour cutting was conducted. A comer radius error, an uncut width and a kerf were measured and evaluated.

Development of 3-D Modeling for Abrasive Waterjet Drilling Process (어브레시브 워터젯에 의한 Drilling의 3차원 모델링 연구)

  • Kwak, Hyo-Sung;Kovacevic, Rodovan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.7
    • /
    • pp.7-14
    • /
    • 1999
  • 어브레시브 워터젯을 이용한 Drilling시 깊이에 대한 예측은 가장 중요한 변주중의 하나다. 이 논문에서는 구멍 깊이의 예측 및 구멍 형상을 연구하기 위하여 3차원 해석 모델이 제안되었다. 해석 모델은 크게 두 가지로 구성되었다. 하나는 비선형 반복 방정식에서 생성된 입자의 운동식이며, 다른 하나는 수많은 입자에 의한 충돌시 가공능력을 규정지우는 Constitutive Equation으로 구성되었다. 이 모델은 구멍 가공이 진행됨에 따라 발생하는 감쇠 효과를 고려하였다.실험적인 고찰이 해석모델의 유용성을 검증하기 위하여 이루어졌으며, 근사한 결과를 보였다.

  • PDF

Efficiency Evaluation of Wind Power Blade Surface Cleaning using Brush and Water Jet (브러시 및 워터젯을 이용한 풍력 발전 블레이드 표면 청소 효율 측정)

  • Jeon, Minseok;Kim, Byunggon;Park, Sora;Hong, Daehie
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.9
    • /
    • pp.977-982
    • /
    • 2013
  • Blades of wind energy plants are exposed to external shocks or internal cracks during operation. Furthermore, the blade surfaces can be contaminated by substances such as dust, blood of birds, salt or insects which can decrease the electricity generation efficiency significantly. For this reason, many blade cleaning companies started to appear and a variety of methods for cleaning were suggested. Despite these diverse methods, there has been no study to investigate how effectively to clean the substances in quantitative manner. In this paper, the cleaning efficiency of two rotor blade cleaning methods, brush and water-jet, is examined through experiments by changing operating parameters. Then, the optimal operating conditions for both methods are derived.

A Study on the Frosting Phenomena of Abrasive Waterjet Microcutting for Multi-Layered Materials (연마제 워터젯을 이용한 복합재 미세가공의 백화현상에 대한 연구)

  • Park, Kang-Su;Bahk, Yeon-Kyoung;Go, Jeung-Sang;Shin, Bo-Sung
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.5
    • /
    • pp.183-190
    • /
    • 2007
  • It is well known that abrasive waterjet(AWJ) was developed as a kind of high-density energy processing technologies. AWJ is used to obtain the better cutting quality of various materials such as metals, ceramics, glass and composite materials within a short manufacturing time because of the characteristics of heatless and noncontact processing. However, AWJ device still has some problems to obtain the high quality of thin workpiece. In this paper, we investigated the optimal microcutting conditions of AWJ, such as maximum pressure, cutting speed and standoff distance of thin multi-layered materials. The experimental results show that AWJ has possibilities and potential to apply to the microcutting of thin multi-layered materials for IT industrial applications.

A Study on the Heat Transfer Characteristics of Water-Jet-Impingement (노후하수관 워터젯분사장치의 분사조건에 따른 열전달특성에 관한 연구)

  • Roh, Hong-Koo;Lim, Kyung-Bin;Noh, Jong-Ho;Lee, Young-Ki;Lee, Sung-Cheol;Ko, Jun-Bin
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1190-1194
    • /
    • 2008
  • The study aims to analyzed and identify the heat transfer characteristics of water-jet-impingement with use of 3-D numerical-analysis in order to design the old water duct. The temperature comparison processes were done with various duct flows. In addition, the optimal conditions of water-jet-impingement were proposed as jet-pressure, the temperature on the beat plane, and so on.

  • PDF

Development of the stone surface process equipment by Water Jet System (워터젯 시스템을 이용한 석재표면처리장치 개발)

  • 강지호;장명환
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.26 no.3
    • /
    • pp.31-38
    • /
    • 2003
  • There is boner process of stone manufacturing to become quality down of stone to consolidated micro crack appearance of stone surface and biotite by fire that is to be route process in stone surface by flame of LPG. And then, it is develop that stone surface process equipment by automation for the work method of boner process can be substitute work method by water jet To development of equipment, There is to be down noise and dust. According to remove calamity growth hazardous substance in the work environment, there is to solve workplace avoidance factor.

Removal of Hydrogen Fluoride from Waterjet Plasma Wastewater by Electrocoagulation (전해응집법에 의한 불화수소 함유 워터젯 플라즈마 폐수처리)

  • Lee, Chae Hong;Chun, Young Nam
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.10
    • /
    • pp.702-708
    • /
    • 2012
  • Tetrafluoromethane ($CF_4$) has been used as etching and Chemical Vapor Deposition (CVD) gases for semiconductor manufacturing processes. These gases need to be removed efficiently because of their strong absorption of infrared radiation and long atmospheric lifetimes which cause the global warming effect. Also, the wastewater including the fluorine is caused by of the ground water pollution. Long-term consumption of water containing excessive fluoride can lead to fluorosis of the teeth and bones. The wastewater including the fluorine among the by-product which is generated by using the waterjet plasma after destroying $CF_4$ by HF is generated. The system which can remove the hydrogen fluoride among the wastewater by using the electrocoagulation using this wastewater the aluminum electrode was developed. The operating condition such as initial pH, electrocoagulation time, wastewater flow rate, current density were investigated experimentally using a electrocoagulation. Through the parametric studies, the highest hydrogen fluoride destruction of 85% was achieved at 3.5 initial pH, 10 min electrocoagulation time, 10 mL/min wastewater flow rate and $159A/m^2$ current density.