A Study on the Performance Improvement of a Simultaneous Heating and Cooling Water Source Heat Pump System by Controlling of the Refrigerant Flow Rate in an Outdoor Unit (수열원 냉난방 동시형 히트펌프 시스템의 실외 열교환기 유량제어를 통한 성능개선에 관한 연구)

  • Bae, Heung Hee;Lee, Dong Hyuk;Lee, Sanghun;Kim, Byengsoon;Ahn, Young Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제25권3호
    • /
    • pp.131-136
    • /
    • 2013
  • The present study has conducted cycle design and control technology of a water source VRF heat pump system. Previously, study of a simultaneous heating and cooling in an air source VRF heat pump system has been conducted. However, performance data and design methods for simultaneous heating and cooling in a water source VRF heat pump system are limited in the literature, due to various system parameters and operating conditions. In this study, the operating characteristics and performances of a simultaneous heating and cooling heat pump system are carried out, in simultaneous operation modes. Control logics of an EEV are developed for flow rate control to the outdoor unit, and are verified. When the control logics are applied, the simultaneous cooling and heating performances are sufficiently achieved, and system COPs are increased by up to 23.4%.

A Study on Characteristics of DPF for Heavy-duty Diesel Engine on Pollutant Emission Reduction (대형디젤엔진 배출가스 저감을 위한 DPF의 재생특성 연구)

  • Eom, D.K.;Lee, S.H.;Oh, S.K.
    • Journal of Power System Engineering
    • /
    • 제12권5호
    • /
    • pp.34-39
    • /
    • 2008
  • The combustion purpose of diesel engine is to reduce the emission of green gas and to produce high output. Generally, the regulation matter of emission gas is largely diveded by 'THC', 'NOx', 'CO' and 'PM'. Among those matters, the most problem is to disgorge into 'PM', the character of diesel combustion. Diesel PM can be controlled using Diesel Particulate Filter, which can effectively reduce the level of soot emissions to ambient background levels. $NO_2$ generated by the DOC is used to combust the carbon collected in the DPF at low temperature. To certificate DPF device that is suitable to domestic circumstances, it is necessary to exactly evaluate the DPF devices according to the regulation of DPF certificate test procedure fur retrofit. To do carry out the above-mentioned description the understanding of that regulation like the standard of PM reduction is needed. In this study the test procedure including test cycle and BPT test condition was examined, and also the test result for specific DPF was analyzed. In every test like field test, PM reduction efficiency test and Seoul-10 mode test, no defect was showed.

  • PDF

The Grid Strap Vibration Characteristics of the 5×5 Nuclear Fuel Mock-up (5×5 핵연료 모의 집합체의 지지격자 스트랩 진동특성)

  • Kim, Kyoung-Hong;Park, Nam-Gyu;Kim, Kyoung-Ju;Suh, Jung-Min
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • 제22권7호
    • /
    • pp.619-625
    • /
    • 2012
  • Since the fuel is always exposed to turbulent flow, the grid strap shows flow induced vibration characteristics that impact on the nuclear fuel soundness. The dynamic behavior of grids in nuclear fuels is quite complex, since two pairs of spring and dimple support are contacted with rods by friction in the limited space. This paper focuses on investigation of the grid strap(test fuel strap, TFS) vibration in one cell. TFS consists of a single spring and double dimples. To identify the grid strap vibration, modal analysis of the strap is performed using finite element method(FEM). Modal testing on a $5{\times}5$ grid structure without rods is performed. The modal testing results are compared to analytic results. In addition, random test considering rod effect is performed about a $5{\times}5$ grid with rods under real contact condition in the air. Finally, the strap vibration of a $5{\times}5$ fuel bundle in investigation of flow induced vibration(INFINIT) facility is measured in real fluid velocity condition without heating. It is shown that modal frequencies from the test are almost equal to those peak frequencies in the INFINIT test.

The Fabrication and Operational Characteristics of a Novel Type Superconducting Power Supply for Persistent Current Mode (새로운 형태의 영구전류모드용 초전도 전원장치의 제작 및 운전특성)

  • Kim, Ho-Min;Yun, Yong-Su;Go, Tae-Guk;Han, Tae-Su;Jang, Seung-Chan;O, Sang-Su
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • 제49권12호
    • /
    • pp.771-777
    • /
    • 2000
  • This paper deals with the design and fabrication of a novel superconducting power supply system, and characteristics have been investigated through experiments. Superconducting power supply consists of rotating and static parts, and superconducting magnet. In this experiment, superconducting foils were placed in parallel within the static part of the machine, pumping currents were measured with respect to rotor speeds and excitation currents. In addition, in order to observe the rotating flux distribution in the superconducting foils, several hall-sensors were placed in it. With the flux distribution acquired, effect of the flux on the superconducting foil during the process of current pumping has been discussed. Also, the general operational characteristics of the superconducting power supply system have been investigated on the basis of the current and voltage data, and magnetic field values acquired through the experiments.

  • PDF

Development and Application of Modified Intermittently Aeration mode for Advanced Phase Isolation Ditch (APID) process at Winter Season (APID공정 내 동절기 개량형 간헐포기 운전모드 적용 및 개발)

  • Kwak, Sung-Keun;An, Sang-Woo;Chung, Mu-Keun;Park, Jae-Ro;Park, Jae-Woo
    • Journal of Korean Society on Water Environment
    • /
    • 제25권6호
    • /
    • pp.872-878
    • /
    • 2009
  • Advanced Phase Isolation Ditch (APID) process was studied to develop economic retrofitting technology, for the plants where retrofitting of common activated sludge process is required. In this study, to develop and apply the modified intermittently aeration mode as process control conditions for treating municipal wastewater, a demonstration plant was installed and operated in the existing sewage treatment plant of P city. During this study, the average effluent $BOD_5$, SS, T-N, and T-P concentrations were 6.3, 4.5, 10.0, and 1.3 mg/L. The modified mode decreased the nitrification capability more than the conventional mode in the application period. Nitrate in the anaerobic condition can have a negative effect on biological phosphorus removal. In the decreasing nitrate levels, the modified mode increased the biological ability of removal phosphorus more than the conventional mode in this study. Therefore, newly developed APID process with modified intermittent aeration mode can be one of the useful processes for stable organic matter and nutrients removal.

A Study on the Change of Dynamic Characteristics of Stator Windings due to Generator Operation (발전기 운전에 따른 고정자 권선의 진동 특성 변화)

  • Kim, Hee-Soo;Bae, Yong-Chae;Lee, Doo-Young;Kim, Yeon-Whan;Lee, Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1029-1033
    • /
    • 2006
  • During operation of generator, the excitation force with 120Hz always exist irrespective of No. of poles. Therefore the vibration is generated in the stator end windings and the micro-crack is grown up inside the bars. After all, coolant water is leaked outside the bars or the stator is moved and is worn out. What is more, one bar is touched with another bar so a short circuit may frequently happen in operation. In order to prevent it from occurring, the evaluation of mechanical integrity for generator stator windings is carried out periodically during overhaul period. This help troublesome end windings to complement with insulation material and to change vibration characteristics. In this paper, the evaluation of mechanical integrity for generator stator windings is described and the change of vibration characteristics is analysed.

  • PDF

A Dynamic Simulation Model for the Operating Strategy Study of 1 kW PEMFC (가정용 연료전지 운전 모드 해석을 위한 동특성 모델 개발)

  • Yu, Sang-Seok;Lee, Young-Duk;Hong, Dong-Jin;Ahn, Kook-Young
    • Journal of Hydrogen and New Energy
    • /
    • 제19권4호
    • /
    • pp.313-321
    • /
    • 2008
  • Dynamics of the proton exchange membrane fuel cell is specially important when the system is frequently working on transient conditions. Even though the dynamics of proton exchange membrane fuel cell for residential power generation is less critical than that of PEMFC for transportation application, the system dynamics of PEMFC for RPG can be very important for daily start-up and stop. In particular, thermal management of the PEMFC for RPG is very important because the heat generation from electrochemical reaction is delivered to the home for hot water usages. Additionally, the thermal management is also very important for heat balance of the system and temperature control of the fuel cell. The objective of this study is to develop a dynamic system model for the study of PEMFC performance over various BOP options. Basic simulation results will be presented.

Generalized Nyquist Criterion for the Stability of Xenon Oscillation (일반화된 Nyquist 요건에 의한 제논진동의 안전성 분석)

  • Park, You-Cho;Park, Goon-Cherl;Chung, Chang-Hyun;Park, Chong-Kyun
    • Nuclear Engineering and Technology
    • /
    • 제22권4호
    • /
    • pp.371-379
    • /
    • 1990
  • The Xenon spatial oscillation may give rise to operational difficulties in a nuclear power plant. In this study, in order to investigate the Xenon instability for a PWR, the frequency-domain technique is adopted by using Generalized Nyquist Criterion, which is more general and suitable for the multi-input/multi-output system. Also linearized modal fluxes are obtained by a modal expansion. This model has been implemented to test the axial Xenon stability of YGN-1 unit against the changes in plant operating parameters ; power level, control rod position, and core average burnup. The results show that the increase of power level and the deeper insertion of control rod have the destabilizing effect, and that the burnup progress makes the core less stable. Also the results show that the overestimation due to modal interaction was found not to be significant.

  • PDF

A Thermal Performance Analysis on the Operation Modes of Radiant Floor Heating System Using SERI-RES (SERI-RES를 이용한 Radiant Floor Heating System의 열 성능 분석)

  • Chun, Won-Gee;Jeon, Myung-Seok;Auh, P.Chung-Moo
    • Solar Energy
    • /
    • 제11권2호
    • /
    • pp.29-33
    • /
    • 1991
  • The present paper deals with two types of heating methods widely used for the Radiant Floor heating systems in Korea. Of these, one method circulates hot water according to the predefined schedule ("intermittent heating") while the other runs the system with the aid of thermostats ("continuous heating"). The standard version of SERI-RES has been modified for the numerical simulation of the problem. Preliminary results show relatively large temperature swings in the case of intermittent heating with solar availability. On the other hand, the case of continuous heating would avoid such undesirable temperature fluctuations. These results are also verified by experimental evaluations.

  • PDF

The study on Harmonic Current Generated on Power Supply Station in(for) Conventional line and The Review on Effect of facility reducing Harmonic Current. (기존선 변전소에서의 고조파 발생현황과 저감설비 설치 효과 검토)

  • Park Sang-Ock;Lee Jong-Woo;Kwon Sam-Young;Lee Chang-Moo
    • Proceedings of the KSR Conference
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1309-1315
    • /
    • 2004
  • The harmonic current originated from electric cars will be cause of electromagnetic interference along adjacent communication cables and troubles with signaling. It will also cause overheating in power capacitor and malfuction in protection relay. Therefore, it brought actual measurement of harmonic current by each operation mode. Because the result exceeded the value prescribed by Korea Electric Power Corporation, we constructed facilities reducing harmonic current on overloaded part at each power supply station located in conventional line (Guro, Kyungsan, and Milyang) as an optimal alternative. Then, this study compared and analyzed the reducing effect before and after constructing facility.

  • PDF