• Title/Summary/Keyword: 운동 정확도 측정

Search Result 254, Processing Time 0.024 seconds

Software Architecture of a Wearable Device to Measure User's Vital Signal Depending on the Behavior Recognition (행동 인지에 따라 사용자 생체 신호를 측정하는 웨어러블 디바이스 소프트웨어 구조)

  • Choi, Dong-jin;Kang, Soon-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.3
    • /
    • pp.347-358
    • /
    • 2016
  • The paper presents a software architecture for a wearable device to measure vital signs with the real-time user's behavior recognition. Taking vital signs with a wearable device help user measuring health state related to their behavior because a wearable device is worn in daily life. Especially, when the user is running or sleeping, oxygen saturation and heart rate are used to diagnose a respiratory problems. However, in measuring vital signs, continuosly measuring like the conventional method is not reasonable because motion artifact could decrease the accuracy of vital signs. And in order to fix the distortion, a complex algorithm is not appropriate because of the limited resources of the wearable device. In this paper, we proposed the software architecture for wearable device using a simple filter and the acceleration sensor to recognize the user's behavior and measure accurate vital signs with the behavior state.

Data Analysis and Processing Methods of Magnetic Sensor for Measuring Wrist Gesture (손목운동 측정을 위한 자기장 센서 데이터의 분석 및 처리 방법)

  • Yeo, Hee-Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.28-36
    • /
    • 2020
  • As many types of magnetic sensors are widely applied in various industries, the analysis and processing of magnetic sensor data need to be accurate. On the other hand, owing to the complexity of the magnetic field line caused by a moving magnet, the magnetic data generated by magnetic sensors are unpredictably nonlinear. Many industry systems using magnetic sensors have struggled with the nonlinear nature of magnetic sensor data. To reduce the effect of the nonlinearity, they have the target objects fixed firmly. Therefore, to collect accurate and reliable data, considerable efforts have been made to resolve the issues with the expensive tools and systems required. Through this paper, to tackle the issues, the data analysis and methodologies, including intelligent algorithms, are presented for the wrist rehabilitation system using magnetic sensors while being implemented without using expensive tools or systems. On processing magnetic sensor data, this paper adopted an intelligent algorithm, fuzzy logic, and compared the performance of other algorithms for comparison.

허혈성 심질환의 자기공명 영상 진단

  • 최영희
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.5-20
    • /
    • 2002
  • 허혈성 심질환 환자의 평가도구로서 MRI의 역할이 확대된 데에는 소위 "one-stop shop"이라는 통합적 심장검사법의 개발이 계기가 되었다. 즉 한 번의 MRI 검사로서 심실벽운동을 평가하여 심근의 기능과 예비능을 측정하여 만성 심근경색을 평가할 수 있고, 심근의 관류를 평가할 수 있고, 관동맥의 혈류 예비능과 심근의 viability를 평가하고, 관동맥 조영술을 통해, 수술 후의 우회로 평가 및 관동맥의 협착 여부의 진단이 가능한 프로토콜이 MRI장비마다 각각 개발되어 보급되고 있다. 하드웨어와 소프트웨어의 개발과 지속적인 연구를 통해서 MRI는 허혈성 심질환의 진단적 검사로서 기존의 다른 검사들과 비교하여 높은 시간적, 공간적 해상력으로 정확한 구조와 기능의 평가를 제공할 수 있는 가장 유용한 검사가 될 것으로 사료된다 특히, MR 관동맥조영술, 심근관류검사, 심근 표지법, dobutamine 부하검사, viability 평가, plaque characterization, MR spectroscopy 분야에서 현재 활발히 연구가 진행되고 있으며 향후 임상적용이 확대될 것으로 예상된다.

  • PDF

A study on the Error Separation Method in Rotation Accuracy Measurement of High Precision Spindle Unit (고정밀 스핀들의 회전정밀도 측정 오차 분리법에 관한 연구)

  • Kim, Sang-Hwa;Kim, Byung-Ha;Jin, Yong-Gyoo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.1
    • /
    • pp.78-84
    • /
    • 2014
  • The rotation of a spindle unit must be accurate for high-quality machining and to improve the quality of the machine tools.Therefore, the proper measurement of the rotation accuracy and ensuring a proper analysis are very important. Separate processes are necessary because spindle errors and roundness errors associated with the test balls can both factor into the measured rotation error values. We used three methods to discern test ball errors and analyzed which could be deemed as the most proper technique in a test of the rotation accuracy of the main spindle of a machine tool.

Development of Monitoring System for the weak and the elderly (노약자 활동상황 감시를 위한 시스템의 개발)

  • Kang, Dong-Youn;Yun, Hee-Hak;Park, Chan-Sik;Cha, En-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.93-94
    • /
    • 2007
  • 노약자 활동상황 감시에서 활동정보와 위치정보는 매우 중요하다. 본 논문에서는 3축 가속도센서와 ZigBee 통신을 이용하여 노약자 활동상황 감시를 위한 시스템을 개발하였다. 가속도센서로부터 활동량을 측정하고 운동량을 계산하기 위한 걸음 검출을 하며, ZigBee 통신을 이용하여 감시시스템으로 전송하여 실시간으로 노약자의 활동상황을 모니터링 할 수 있다. 추가로 부착위치에 강인한 걸음 검출 알고리즘을 제안하였으며, 실제 실험을 통해 가속도센서를 가슴에 부착할 경우 99.83%의 정확도로 걸음을 검출할 수 있음을 확인하였다. 또한 ZigBee 통신의 수신신호세기를 이용하여 노약자가 있는 방을 구별할 수 있었다.

  • PDF

Effect of Exercise Program of a Public Health Subcenter for Middle and Old Aged Women in an Urban Area (장.노년기 여성의 운동 프로그램 시행 전.후의 신체계측치와 혈액검사치의 변화 비교- 일개 도시 보건지소를 중심으로 -)

  • Gueon, Jun-Gyeong;Lee, Kyeong-Soo;Hwang, Tae-Yoon;Sohn, Seok-Joon;Kim, Kyoung-Won;Jang, Eun-Jin
    • Journal of agricultural medicine and community health
    • /
    • v.34 no.3
    • /
    • pp.359-367
    • /
    • 2009
  • Objectives: This study was to identify the changes of body fat, blood pressure, blood glucose and serum lipid of middle and old aged women after participation in exercise program which includes aerobic(dance sports) and anaerobic(dumbbell gymnastics) exercises. Methods: One hundred women aged from 55 to 72 were surveyed before and after an exercise program. The exercise program was provided to the subjects performed during 6 months from July, 2007 to December, 2007 at a public health subcenter in Gumi City. Questionnaire survey for general characteristics, anthropometric measurement and blood test were taken before starting the program and anthropometric measurement and blood test after completing the program. Results: Body Weight, body fat and blood pressure showed significant change after the exercise program(p<0.05). Additionally in total glucose, total cholesterol and triglyceride significant change was observed(p>0.05). Waite circumference decreased, however did not show statistically significant difference. Conclusions: It was effective to participate in dance sports and dumbbell gymnastics exercise regularly. All of the positive changes through the study showed that there should be the program for middle and old aged women to exercise actively and also the middle and old aged women need have a active exercise habits as regular as possible. Additional studies confirming the results of this study are needed to compare the effects of the dance sports and dumbbell gymnastics exercise on the other age groups.

A Study on Neuroactive Response Measurement Platform using Mechano Sensor (Mechano sensor를 이용한 신경자극반응 측정 플랫폼에 관한 연구)

  • Kim, Woo-Ram;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.198-201
    • /
    • 2012
  • This is a study about a platform realization measuring the extent of reaction in nerve, as giving a electrical impulse on a nerve pulp regulating a function of muscle, about a measurement of nerve reaction in the amount of current, the lasting time of current, and the position of electrode from a electrical impuls. The position of an electrode in a electrical nerve impuls have nothing to do with all nerves from exercise to all things. There is the Single Twitch Stimulation, Train-of-four, and Double Burst Stimulation in the form of nerve stimulation. This report is needed for selecting MCU of low electric power for a base in embedded system and measuring the extent of reaction after making a sensor interface to know sensitivity of measuring sensor in basic reaction of nerve impuls. The platform is realized to select a high efficiency AD Convertor for raising accuracy in measured data. As the platform in this report was developed for a medical appliances, it was designed to consider user safety in electric power Isolation when making electric power circuit.

  • PDF

Performance Evaluation of Inertial Balance for Measuring Mass in Microgravity (마이크로중력환경에서 사용 가능한 관성저울의 성능평가)

  • Jang, Hyun-Jin;Lee, Joo-Hee;Choi, Jae-Hyuk;Park, Seul-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.12
    • /
    • pp.1395-1401
    • /
    • 2014
  • In an effort to develop and implement an inertial balance with high performance, the response characteristics of a load cell, which are some of the critical parameters for optimal system design, were evaluated using a sample object of approximately 100 g under microgravity conditions. To this end, a 15-m drop-tower was used to produce microgravity conditions, and the response characteristics of the load cell were investigated in terms of the variations in the magnitude of the deceleration of the sample object, noting that the mass of a living animal should be determined in microgravity. An analysis of the ratio of the inertial forces clearly demonstrated that the average velocity of a load cell plate should be higher than 0.5 m/s to meet the design requirements.

Effect of Design variables of Rail Surface Measuring Device on Acoustic Roughness and Spectral Analysis (레일표면 측정장치의 설계변수가 음향조도 스펙트럼 분석에 미치는 영향)

  • Jeong, Wootae;Jeon, Seungwoo;Jeong, Dahae;Choi, Han Shin
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.4
    • /
    • pp.440-447
    • /
    • 2017
  • Spectrum level for the acoustic roughness of wheels and rail surface should be periodically maintained under the limitation of ISO to reduce rolling noise of railway vehicles. Thus, in maintaining railway track, displacement sensor-based measuring devices are broadly used to measure the surface roughness and to perform spectral analysis. However, these measuring devices cause unexpected measuring errors since the displacement sensors are fixed at moving platforms and the main frame produces pitching motion during measurement. To increase the accuracy of the measured values, this paper has investigated the effects of design variables such as wheel base, additional wheels, and elastic deformation of wheels on the surface roughness and acoustic roughness spectrum.

Residual Neuromuscular Sensing Platform Development using Sensor of Nerve Stimulation Response Measurement during Anesthesia (신경자극반응 측정 센서를 이용한 마취 시 잔여근이완 감지 플랫폼 구현)

  • Shin, Hyo-Seob;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.459-462
    • /
    • 2010
  • Response to nerve stimulation platform for implementing measures to detect finger movement has been functioning as an important factor. This stimulated finger on the nerve and muscle responses would vary. In other words, the finger movement of the muscle response to nerve stimulation and sensing Actuator for the H/W development is needed. In addition, a low power embedded CPU based on the top was used. H/W configuration portion of the isolation power, constant current control, High impedance INA, amplifier parts, and the stimulus mode and the Micro-control the status of current, AD converter Low Data obtained through the processing system is implemented.

  • PDF