• 제목/요약/키워드: 욕조성

검색결과 32건 처리시간 0.028초

욕조에서의 전위분포 해석 및 전격재해 위험성 평가 (Analysis of the Electric Potential distribution and Evaluation of Electric Shock Risk in Bathtub)

  • 김종민;김한상;정종욱;정진수;김성철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.37-40
    • /
    • 2006
  • This paper presents the evaluation electric shock risk In bath so that we made and designed a bathtub which is the same size in real public bath. and then we did an experiment, provided of electric leakage in various conditions so, we measured how to form an electric potential and knew the electric potential is formed variously under exposed conductor in bath. also we made certain that electric shock risk is down if we insert an insulated pipe in bathtub pipe which is prevent from being formed the electric field sharply.

  • PDF

욕조에서의 전위분포 해석을 통한 전격재해 위험성 평가 (Evaluation on Electric Shock Risk due to the Electric Potential Distribution in Bathtub)

  • 김종민;김한상;김성철;김두현
    • 한국안전학회지
    • /
    • 제22권1호
    • /
    • pp.40-46
    • /
    • 2007
  • It is evaluated that electric shock risk in bath so that we made and designed a bathtub which is the same size in real public bath. And then, we did an experiment, provided of electric leakage in various conditions, so we measured how to form an electric potential and knew the electric potential is formed variously under exposed conductor in bath. Also, we made certain that electric shock risk is down if we insert an insulated pipe in bathtub pipe which is prevent from being formed the electric field sharply. The results show that the increased shock risk and safe distance are estimated by the bathtub of limited width and depth, and the voltage simulated on the basis of Flux 3D concept is compared with the measured value.

철도전력시스템에서의 유지보수를 위한 고장률 분석에 관한 연구 (A Study on Failure Analysis for Maintenance in Railway Power System)

  • 신동근;김형철;권삼영;박현준;장길수;이기천
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.2054-2055
    • /
    • 2007
  • 이 논문에서는 철도전력시스템에서의 유지보수를 위한 고장률 분석에 관하여 설명하고 있다. 유지보수와 관련된 문제들은 시스템의 다른 부분과도 연관이 있어 기계적 사고의 위험성을 증가시킨다. 그러므로 설비는 교체와 예방정비를 겪게 된다. 여기서는 유지보수의 방법을 욕조곡선을 기반으로 정할 것이다.

  • PDF

가정용수 용도별 사용량의 통계적 특성 분석 (Analysis on Statistical Characteristics of Household Water End-uses)

  • 김화수;이두진;박노석;정관수
    • 대한토목학회논문집
    • /
    • 제28권5B호
    • /
    • pp.603-614
    • /
    • 2008
  • 가정용수의 용도별 사용량은 주거형태, 거주자 생활양식, 주택구조 등의 내부적인 요인과 온도, 날씨, 수도요금 등과 같은 다양한 외부요인들의 영향을 받게 된다. 장기적으로는 거주민의 생활양식, 주거형태, 수도관련 시설의 변화 등에 따라 사용량이 점진적으로 변화하게 되며, 단기적으로는 기온이나 가뭄과 같은 기후조건이나 절수정책과 같은 인위적인 영향에 의해 사용량이 크게 변화하기도 한다. 용수수요에 영향을 미치는 인자에 대한 분석과 이해는 사용량의 변화원인과 경향을 설명해주고 여러가지 인자와의 상관관계를 분석함으로서 물사용패턴과 향후 수요를 예측하는데 도움을 준다. 본 연구에서는 가정용수의 용도별 사용량 실측자료를 바탕으로 사용패턴과 사용량에 미치는 영향인자를 분석하기 위하여 요일별, 월별, 계절별 사용량을 비교하고, 또한 가구특성, 기온 등의 외부인자에 의해 영향을 받는 용도에 대해서도 살펴보았다. 가정용수의 사용패턴을 분석한 결과, 토요일에 사용량이 가장 많고, 월간 중에는 7월의 사용량이 가장 높았으며, 월별 사용량의 첨두율은 평균대비 1.12로 나타났다. 기온에 따른 용도별 사용경향에서 총량용수는 $-14^{\circ}C{\sim}0^{\circ}C$까지 물사용량이 급격하게 증가하는 경향을 보였으나, $0^{\circ}C$이상에서는 큰 변화양상을 보이지 않았다. 반면에 세면, 세탁, 욕조용수는 $0^{\circ}C$이상에서도 점진적인 증가경향을 보였으나, 변기용수는 오히려 감소하는 경향을 보였다. 기온에 대한 용도별 사용량의 상관관계 분석결과 세면용수가 상관계수 0.73으로 상관성이 가장 높았으며, 변기용수는 -0.14로 매우 낮은 음의 상관성을 보였다. 각 인자별로 가정용수 사용량 원단위의 차이에 대한 유의성 여부를 검토하기 위하여 주택유형, 실거주인수, 가족구성, 건평, 수입, 맞벌이여부, 절수형변기, 비데기유무 등에 대하여 분산분석을 수행한 결과, 주택유형의 경우 욕조용수의 사용량에 차이가 발견되었고, 실거주인수는 싱크대, 변기, 기타, 총량용수에서 유의한 차이가 발견되었다. 특히 실거주인수는 세면과 욕조를 제외한 모든 용도별 사용량에서 유의한 차이를 보여 거주인수의 증감에 따라 용도별 사용량의 차이가 분명히 발생하며, 이는 향후 가구당 용수사용량을 설계하는 경우 평균 거주인수에 대한 신중한 검토가 필요할 것으로 판단되었다. 이러한 가정용수의 용도별 사용특성 분석결과는 수요예측, 수요관리 정책수립, 수도관련 기자재 및 시설의 규격결정 등에 기초자료로 활용될 수 있을 것으로 기대된다.

공중욕조에서의 FLUX3D에 의한 전위분포 해석 및 인체의 전격위험성 평가 (Electric Shock Risk Assessment of the Human Body and Potential Distribution Analysis by FLUX3D in a Public Bathtub)

  • 김두현;김성철;이종호;김한상;김종민
    • 한국안전학회지
    • /
    • 제22권2호
    • /
    • pp.41-46
    • /
    • 2007
  • This paper considers the electrical shock risk of the human body due to underwater leakage current in such places of public baths. Many submerged electric facilities in a public bath may create a severe electric shock hazard for the human body, since wet body in an accidentally energized bathtub can result in low electrical resistance through the human body for leakage or fault currents. Therefore a major consideration, in the context of electrical safety underwater, is the shock risk to the bather as a result of electric current flowing through the water in bathtub. To assess the electric shock risk and to analyze the potential distribution in a bathtub, 2 different situation cases are set up, then experimental and simulation methods are adopted. The validity of 2 cases of simulation and experiment data in a bathtub for electric distribution underwater are compared and analyzed. Also electric shock risk assessment underwater in a real public bathtub by simulation program package, Flux 3D, was conducted herein, and the results are presented and discussed.

이중구조 무기형광 함침막 제조 및 방사성핵종 탐지능력의 분석 (Preparation and Radionuclide Detection Analysis of Inorganic Fluor Impregnated Double-layered Membranes)

  • 이근우;서범경;박진호;남석태;한명진
    • 멤브레인
    • /
    • 제12권4호
    • /
    • pp.240-246
    • /
    • 2002
  • 방사선과의 상호작용에 의하여 섬광이 발생하는 무기형광체(inorganic fluor)인 cerium activated yttrium silicate(CAYS)를 폴리설폰 고분자막에 함침시킴으로써, 형광 용액의 도움 없이 방사능 오염도를 측정할 수 있는 새로운 측정막을 제조하였다. 막의 제조는 두 가지 공정으로 나누어진다. 우선 고분자와 용매의 균일한 1차 제막용액을 유리판 위에 제막 후 용매증발을 통해 폴리설폰 고분자막이 생성되도록 하였다. 고형화된 폴리설폰 필름 표면에 CAYS가 분산된 고분자 제막용액을 2차로 도포시킨 후, 비용매 욕조에 침지시키는 상전환 공정을 이용하거나 용매의 증발을 통한 유리화에 의해 2차 용액의 고형화를 유도함으로써 함침막을 제조하였다. 이렇게 제조된 막의 형상은 치밀한 구조를 지니는 고분자 지지체와 이에 완전히 고착된 CAYS함침막의 이중구조를 지니게되며, 지지체 부분은 막의 안정성을 2차 제막에서 생성된 부분은 기능성의 향상을 이룰 수 있는 구조적 특성을 지닌다. 제조된 함침막에 방사성핵종을 직접 도포하여 방사성핵종의 탐지 특성을 측정하였을 때 효율적인 탐지 특성을 지니는 것으로 확인되었다.

단거리전용통신방식 노변기지국의 예비부품수 및 교체시기 산정 (The Estimation of the Number of Spare Parts and the Changing Time about DSRC Road Side Equipment)

  • 한대희;이청원
    • 한국ITS학회 논문지
    • /
    • 제6권3호
    • /
    • pp.174-182
    • /
    • 2007
  • 현재 국내 ITS는 현장장비 유지관리에 대한 연구 및 고장관련 DB가 부족하여 예비부품수 및 교체시기 산정에 대한 규정이 없는 실정이다. 이에 본 연구는 실제 고장이력자료를 갖고 신뢰성 분석을 실시하여 단거리전용통신(DSRC)방식 노변기지국(RSE)의 예비부품수 및 교체시기를 산정하였다. 전체 수집기간동안의 고장자료는 욕조곡선의 형상을 나타내어 우발고장기간의 자료로 신뢰성 분석을 실시하였으나 고장 수명 분포 중 적합되는 분포가 없었으며, 이러한 사실은 본 연구대상 노변기지국(RSE)의 경우 통계적 모형에 의한 예방 정비가 어려움을 의미한다. 따라서, 본 연구는 실증적인 방법으로 하자보수기간 $1{\sim}2$년 동안의 수리비용 및 고장빈도 이력자료를 활용하여 노변기지국(RSE)의 교체여부를 결정하는 방법 및 필요 예비부품수를 산정하는 방법을 제안하였다. 향후에는 노변기지국(RSE) 외에 다른 ITS 장비에 대한 신뢰성 분석이 필요하다.

  • PDF

수술적 처치가 필요했던 식도이물에 관한 임상적 고찰 (A Surgical Treatment of the Esophageal Foreign Body (10 cases report))

  • 황의두;황경환
    • Journal of Chest Surgery
    • /
    • 제30권11호
    • /
    • pp.1117-1120
    • /
    • 1997
  • 충남대학교병원에서 1980년7월부터 1995년 8월까지 경험한 식도이물 10례를 수술 치료하였다. 나이는 25 세에서 71세로, 평균 나이는 45.3세였고 남녀의 비는 6:4였다 가장 흔한 증상은 연하곤란, 발열, 이물감, 경부 동통이였다. 이물질은 생선뼈 3례였고, 거품 약포장지가 2례였고, 맥주병 마개,욕조 물마개, 깨진 사발 조각, 닭고기, 콩이 각각 1례였다. 진단은 수용성 식도 조영제와 식도 내시경을 이용하였다. 10례중 2례에서는 과거에 가성소다 섭취로 인해 식도 협착이 있었다. 1례에서는 정신과적 문제가 있었다. 식도이물은 모두 수술적 처치로 제거하였다 5례에서는 경부식도절게술을 시행하였고 1례는 우측 개흉술 을, 1례는 개복하여 위를 통해 위관을 역류성으로 통과 제거하였으며, 2례는 경부농양이 있어 절개후 배농하 였다. 3례는 수술 후 누출이 있었으나 수술치료없이 보존적 요법으로 호전되었으며,1례는 일시적인 애성이 있 었다. 1례는 외상성 기흉이 발생하여 폐쇄적 홉관 삽관술로 치료하였다. 수술 사망자는 없었다.

  • PDF

비행기지 RAPCON 유지보수비용 추정 (Estimating Maintenance Cost of RAPCON at Air Force Base)

  • 방장규;이근영
    • 한국항행학회논문지
    • /
    • 제20권6호
    • /
    • pp.511-518
    • /
    • 2016
  • 본 연구는 RAPCON을 구성하는 구성요소를 체계별로 구분하고 체계별 운영시간 에 따른 고장율 등을 분석한다. 아울러 설계수명에 점차 도달한 RAPCON의 운영 중 발생한 유지보수비용 데이터를 토대로 남은 설계수명 기간 동안 향후 발생 가능한 유지보수 비용을 추정한다. 이런 분석결과를 통해 장비의 신뢰성 관련 선행연구들에서 주로 인용되고 있는 욕조커브 (bathtub curve) 이론과 본 연구의 비용예측 결과와의 연관성을 진단하고 안정적인 유지보수를 위한 기초자료로서 활용되고자 한다. 본 시계열 분석에 사용된 자료는 T국 공군이 구형 RAPCON을 신형으로 교체하면서, 설계수명이 다된 기존 RAPCON 운영단계에서 발생했던 50개월의 유지보수비용 데이터이다. 유지보수 비용은 6개 체계별 유지보수비용을 합한 월별 유지보수비용으로 사용하였다. ARIMA 모형을 토대로 향후 10개월 간 발생 가능한 유지보수 비용을 예측한 결과 비용이 상승할 것이라는 통계적으로 신뢰할 만한 추정 결과를 얻었다.

폴리설폰 필름의 형상 및 방사성 오염물 채취에 있어 용매처리의 효과 (Effect of Surface Modification by Solvent Treatment on Morphology and Radionuclide Pick-up Efficiency of Polysulfone Film)

  • 한명진;이근우;서범경;박진호;남석태
    • 멤브레인
    • /
    • 제14권2호
    • /
    • pp.126-131
    • /
    • 2004
  • 균일한 밀집구조를 지니는 투명한 폴리설폰 필름이 용매를 사용한 표면처리를 통해 개질되었다. 개질은 고분자 필름을 디메털포름아마이드 용매에 1 sec간 담그고 이를 비용매 욕조에 침지시켜 이루어졌다. 개질 전 투명하였던 필름은 개질 후 횐색을 띠며, 많은 기공이 표면에 형성되었다. 비용매로서 물을 사용하였을 때가 이소프로파놀을 사용하였을 때 보다 표면의 불균일도가 증가하였다. 개질된 필름을 사용하여 방사성핵종으로 오염된 지역으로부터 오염물을 채취하였을 때 일반적으로 사용되는 필터페이퍼를 사용하는 것보다 우수한 채취 효율을 보여주었다. 개질된 필름 중에서는 비용매로 물을 사용한 경우 이소프로파놀을 이용한 필름보다 오염물의 채취 효과가 좋은 것으로 나타났다. 한편, 개질된 필름은 고분자 필름의 양쪽 겉표면만을 변화시켜, 필름의 내부는 고유한 밀집도를 유지함으로써, 필터페이퍼 또는 유리섬유를 사용한 오염물 제거 과정에서 나타날 수 있는 매체의 기공을 통한 2차적 오염을 방지하는 효과가 있다.