Studies on the Syndiotactic Poly(vinyl alcohol) Polarizing Film -Preparation of Low Molecular Weight Syndiotactic Poly(vinyl alcohol)/Iodine Complex Film and Its Characterization- (교대배열 폴리비닐알코올 편광필름에 관한 연구 -저분자량 교대배열 폴리비닐알코올/요오드 복합체 필름의 제조와 특성 해석-)

  • 류원석;염정현;최진현;지병철;노태환
    • Polymer(Korea)
    • /
    • v.24 no.5
    • /
    • pp.713-720
    • /
    • 2000
  • A polymer/iodine complex film was prepared using syndiotactic poly(vinyl alcohol) (s-PVA) with number-average degree of polymerization of 900 and syndiotactic diad content of 63.1%. In comparison with atactic-PVA/iodine films, degree of polarization of the s-PVA/iodine film was improved up to over 99% although a lower transmittance was obtained. By soaking in iodine/potassium iodide aqueous solution of a lower iodine concentration and subsequent drawing by 4 times, s-PVA/iodine film of a higher transmittance and degree of polarization was produced. The degree of iodine desorption of the s-PVA/iodine film in water were very low. The crystallinity and the d-spacing and crystal size of (100) plane increased at the early stage of soaking time, however, remained constant or decreased slightly with increasing soaking time. In consequence, s-PVA/iodine complex formation took place mainly inside crystal region at the initial stage of soaking time, whereas it occurred outside crystal region or physical adsorption of iodine dominated after sufficient soaking.

  • PDF

Comparison of Quality Characteristics of Sesame Oil and Blend Oil by Using Component Analysis and NIR Spectroscopy (참기름과 혼합유의 성분 및 NIR Spectrum 분석을 통한 품질특성 비교)

  • Joo, Jae-young;Yeo, Yong-heon;Lee, Namrye
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.6
    • /
    • pp.739-743
    • /
    • 2017
  • Product distribution and consumption in the military is difficult due to unique contracts and supply systems. It is difficult to change suppliers immediately when quality problem is encountered. Due to these special circumstances, the quality of products must be thoroughly controlled. Sesame oil is used to increase the taste and nutrition of food, but it is more expensive than other cooking oils. Oil producers may blend other cooking oils with sesame oil to make higher profits, so it has become important to identify good and bad products. In this study, pure sesame oil and blend oils were compared by analyzing their smell, taste, chemical components, and near infra-red spectra to determine quality differences between them.

The Study on the Thermal Oxidation of Mixed Rapeseed Oil with Coconut and Palm Oil (혼합 유채유의 가열산화에 관한 연구)

  • 현영희
    • The Korean Journal of Food And Nutrition
    • /
    • v.15 no.4
    • /
    • pp.342-349
    • /
    • 2002
  • Rapeseed oil is easily oxidized due to the high contents of unsaturated fatty acid such as linoleic acid and linolenic acid. For stability of rapeseed oil oxidation, a special process is required. Two kind of simple and interesterifying mixed rapeseed oil were prepared according to add 30%, 50% and 70% of coconut oil and palm oil. Sample oils were heated at 180${\pm}$5$^{\circ}C$ for 5, 10, 15, 20, 25, 30 and 35 hours. Then the physicochemical properties such as the tendency of oxidation were investigated. The initial AV and POV of interesterifying mixed rapeseed oil were higher than those of simple mixed oil. But the tendency of oxidation were similar. While oxidation rate of similar and interesterifying mixed rapeseed oils with coconut oil and palm oil were lower about than those of rapeseed oil.

Development of Self-Diagnosis Linearity Quality Assurance Technique in Computed Tomography by Using Iodic Contrast Media (요오드 조영제를 이용한 전산화단층촬영장치의 자가진단 직선성 정도관리 기술 개발)

  • Seoung, Youl-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.5
    • /
    • pp.436-443
    • /
    • 2015
  • The purpose of this study was to develop a self-diagnostic linearity quality control techniques of computed tomography (CT) by using measured CT number values from the various concentrations of iodine contrast media (CM) is diluted with distilled water under each condition of the tube voltage. The equipment was used for four-channel MDCT, the iodine concentration were using 300 mgI/ml, 350 mgI/ml, 370 mgI/ml and 400mgI/ml. Dilution of CM in distilled water was increased by each 5% until the maximum CT number values were measured. We applied the tube voltages for 90 kVp, 120 kVp, 140 kVp. As a result, we was obtained to the nearest linearity as 0.993 of correlation coefficient between the iodinated CM from 5% to 25% in 400 mgI/ml and the CT number values by 90 kVp. In conclusion, the proposed self-diagnostic linearity quality assurance technique by using iodine CM can be utilized to replace the AAPM CT performance phantom.

Thermodynamics of the Formation of Polynuclear Aromatics-Iodine Charge Transfer Complexes (여러고리 방향족 화합물과 요오드 사이의 전하이동 착물생성에 관한 열역학적 연구)

  • Oh Cheun Kwun;Jeong Rin Kim;Young Hoon Lee
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.6
    • /
    • pp.575-581
    • /
    • 1985
  • Ultraviolet spectrophotometric investigations have been carried out on the systems of benzene, naphthalene and phenanthrene with iodine in carbon tetrachloride. The results reveal the formation of the one to one molecular complexes. The equilibrium constants were obtained in consideration of that absorption maxima due to the formation of the charge transfer complexes shift to blue with increasing temperature. Thermodynamic parameters for the formation of the charge transfer complexes were calculated from these values. These results indicate that the stabilities of the complexes formed between polynuclear aromatics and iodine increase with the number of aromatic rings. This may be a measure of the relative basicities of polynuclear aromatics toward iodine, which is explained in terms of the resonance of the interaction between aromatics and iodine. The results in this study were, additionally, compared with those of the polymethylbenzene series to be discussed the reason for them.

  • PDF

A Study on the Dissolution and Separation for the Quantitative Analysis of Iodide in Spent Nuclear Fuel (사용후핵연료중의 미량 요오드 정량을 위한 용해 및 분리 연구)

  • Choi, Ke Chon;Lee, Chang Heon;Song, Byang Chol;Park, Yang Soon;Jee, Kwang Yong;Kim, Won Ho
    • Analytical Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.751-758
    • /
    • 2000
  • A study was carried out on the dissolution of spent PWR fuels and performed on the fuels and the separation of iodide for the quantitative analysis using SIMFUEL which has chemical composition of a simulated spent PWR fuel (burn-up; 35,000 MWd/MTU and cooling time; 10 years). To dissolve the SIMFUEL effectively and to minimize the formation of volatile iodine through dissolution process, the optimum ratio of mixed acid ($HNO_3/HCl$ 80: 20 mol%) was established and ozone gas was purged. In the separation step of iodine with $CCl_4$, $NH_2OH{\cdot}HCl$ was used for reducing ${IO_3}^-$ to $I_2$.The optimum acidity of the dissolved solution and the added of $NH_2OH{\cdot}HCl$ were 2.5 M and more than $1.5{\times}10^{-3}mole$, respectively. The recovery of iodide by ion chromatography was $82.8{\pm}4.1%$ and the total yield was corrected by gamma spectrometery using $^{131}I$ as a tracer.

  • PDF

Characterization of Deep Learning-Based and Hybrid Iterative Reconstruction for Image Quality Optimization at Computer Tomography Angiography (전산화단층촬영조영술에서 화질 최적화를 위한 딥러닝 기반 및 하이브리드 반복 재구성의 특성분석)

  • Pil-Hyun, Jeon;Chang-Lae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • For optimal image quality of computer tomography angiography (CTA), different iodine concentrations and scan parameters were applied to quantitatively evaluate the image quality characteristics of filtered back projection (FBP), hybrid-iterative reconstruction (hybrid-IR), and deep learning reconstruction (DLR). A 320-row-detector CT scanner scanned a phantom with various iodine concentrations (1.2, 2.9, 4.9, 6.9, 10.4, 14.3, 18.4, and 25.9 mg/mL) located at the edge of a cylindrical water phantom with a diameter of 19 cm. Data obtained using each reconstruction technique was analyzed through noise, coefficient of variation (COV), and root mean square error (RMSE). As the iodine concentration increased, the CT number value increased, but the noise change did not show any special characteristics. COV decreased with increasing iodine concentration for FBP, adaptive iterative dose reduction (AIDR) 3D, and advanced intelligent clear-IQ engine (AiCE) at various tube voltages and tube currents. In addition, when the iodine concentration was low, there was a slight difference in COV between the reconstitution techniques, but there was little difference as the iodine concentration increased. AiCE showed the characteristic that RMSE decreased as the iodine concentration increased but rather increased after a specific concentration (4.9 mg/mL). Therefore, the user will have to consider the characteristics of scan parameters such as tube current and tube voltage as well as iodine concentration according to the reconstruction technique for optimal CTA image acquisition.

Estimation and Application of HU Values for Various Materials as a Function of Physical Factor (물리적 인자의 변화에 따른 다양한 구성물질의 하운스필드 단위 평가 및 응용)

  • Lee, Seung-Wan;Kim, Hee-Joung;Kim, Tae-Ho;Jo, So-Jeong;Lee, Chang-Lae
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.145-151
    • /
    • 2009
  • This study aims to evaluate CT (Computed Tomography) characteristics through the estimation of HU (Hounsfield Unit) and the corresponding variations using coefficient of variation values for various materials as a function of physical factor. HU values for various materials with varying densities as a function of physical factor were measured using MDCT (Siemens SOMATOM Sensation 4, Germany). The results showed that the HU values were decreased and increased as a function of kVp and material density, respectively. Especially, the HU values for bone and iodine at 140 kVp were 32% and 42% smaller than those at 80 kVp, respectively. In case of iodine, the HU values also decreased and increased as a function of kVp and concentration, respectively. While the HU values were fixed as a function of mAs. The decreased ratio of HU values between 80 keV and 140 keV was different at various concentration and maximum difference was shown as 1.73 at 3% concentration. These results indicated that it may be possible to separate composition of materials, e.g. iodine and bone, using single source CT. The results showed that dual energy techniques using single source CT can be applied to material separation and expand CT imaging techniques to other practical applications.

  • PDF

Comparison of the Measured Radiation Dose-rate by the Ionization Chamber and GM(Geiger-Müller) Counter After Radioactive Iodine Therapy in Differentiated Thyroid Cancer Patients (분화성 갑상선암환자의 방사성 요오드 치료시 전리함과 Geiger-Muller계수관에서 방사선량률 측정값 비교)

  • Park, Kwang-hun;Kim, Kgu-hwan
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.565-570
    • /
    • 2016
  • Radioactive iodine($^{131}I$) treatment reduces recurrence and increases survival in patients with differentiated thyroid cancer. However, it is important in terms of radiation safety management to measure the radiation dose rate generated from the patient because the radiation emitted from the patient may cause the exposure. Research methods, it measured radiation dose-rate according to the elapsed time from 1 m from the upper abdomen of the patient by intake of radioactive iodine. Directly comparing the changes over time, high dose rate sensitivity and efficiency is statistically significant, and higher chamber than GM counter(p<0.05). Low dose rate sensitivity and efficiency in the chamber had lower levels than gm counter, but not statistically significant(p>0.05). In this study confirmed the characteristics of calibrated ionization chamber and GM counter according to the radiation intensity during high-dose radioactive iodine therapy by measuring the accurate and rapid radiation dose rate to the patient explains, discharged patients will be reduced to worry about radiation hazard of family and others person.

The Effect of Pressure on the Electrophilic Substitution Reaction of Tetramethyltin with Iodine (Tetramethyltin과 Iodine의 친전자 치환반응에 대한 압력의 영향)

  • Kwun Oh Cheun;Lee Young Hoon
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.6
    • /
    • pp.555-561
    • /
    • 1993
  • Ultraviolet spectrophotometric investigation has been carried out on the system of iododestannylation iodine and tetramethyltin in methanol. The transient CT absorption spectrum can be observed and the subsequent disappearance of CT absorption spectrum was accompained by the cleavage of tetramethyltin with iodine. From there, the rate constants for the iododestannylation were determined at 10, 25 and 35$^{\circ}C$ up to 1600 bar and the reaction rates were increased with increasing temperature and pressure. From these rate constants, the values of the activation parameters (${\Delta}V^\neq,\;{\Delta}{\beta}^{\neq},\;{\Delta}H^{\neq},\;{\Delta}S^{\neq}\;and\;{\Delta}G^{\neq}$) were obtained. The activation volumes and activation compressibility coefficients were both negativity. The activation enthalpies were positive and activation entropies had large negative values. From these values discussed in terms of solvent structure variation of transition state and mechanism. From these results, it was found that the reaction is followed with $S_E2$ mechaenism and weakened $S_E2$ mechanism nature by increasing pressure.