• Title/Summary/Keyword: 요오드화수은

Search Result 14, Processing Time 0.019 seconds

Study on the effect of DSSC(Dye Sensitizer Solar Cell) Material on the electrical properties of Mercuric Iodide (염료감응형태양열 물질이 요오드화수은의 전기적 특성에 미치는 영향에 관한 연구)

  • Cho, Gyu-Seok;Park, Ji-koon;Heo, Seung-Wook;Song, Yong-keun;Han, Moo-Jae;Kim, Kum-Bae;Choi, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.525-529
    • /
    • 2017
  • As a photoconductive material with a high X-ray sensitivity, many researches about mercury iodide has been carried out to substitute for amorphous selenium. However, it has many limitations in commercialization because of the high leakage current. In this study, we fabricated $HgI_2$ unit-cells with mixed silicon oxide($SiO_2$) and titanium oxide($TiO_2$) to reduce a high leakage current and we evaluated an electrical properties of the fabricated unit-cells. As a result, we confirmed that both mixtures were effective in reduing the leakage current of the $HgI_2$ and x-ray sensitivity were significantly increased in fabricated $HgI_2-TiO_2$ unit-cell.

Analysis of the Signal Properties of Polycrystalline $HgI_2$ Film Detector under Radiographic Irradiation Condition (X-선촬영 조사 조건하에서 다결정 요오드화수은 박막검출기의 신호특성 분석)

  • Kim, Jong-Eon
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.289-294
    • /
    • 2010
  • The purpose of this study is an evaluation of the performance of a detector under radiographic irradiation condition by fabricating the polycrystalline $HgI_2$ film detector. The polycrystalline $HgI_2$ film detectors with thickness of 210 and $320\;{\mu}m$ were fabricated by screen print technology. Measurements of X-ray sensitivity and dark current were performed for two detectors. And measurements of the linearity of X-ray response and reproducibility were performed for the detector of thickness $320\;{\mu}m$. For applied electric field strengths from 0.05 to $2\;V/{\mu}m$ to the detector of thickness $320\;{\mu}m$, the X-ray sensitivities were measured from 233 to $1,408{\times}106\;electrons/mR{\cdot}mm^2$. And the dark currents were measured from 3.2 to $118\;pA/mm^2$. Compared with values reported by Zhong Su et al., the X-ray sensitivities exhibit about two times larger than the X-ray sensitivities measured by Zhong Su et al. And the dark currents exhibit about nine times larger than the dark currents measured by Zhong Su et al. The linearity of X-ray response acquired 0.988 as a coefficient of correlation (r). Reproducibility acquired 0.002 as a coefficient of variation. This study provides the performance data of fabricated polycrystalline $HgI_2$ film detector available for an active matrix flat panel imager under radiographic irradiation condition.

A Study on Applicability of Mercury-contaminated Tailing and Soil Remediation around abandoned Mines using Washing Process (세척공법을 이용한 광산주변 수은 함유 오염물질 처리 적용성 평가)

  • Kwon, Yo Seb;Park, So Young;Koh, Il Ha;Ji, Won Hyun;Lee, Jin Soo;Ko, Ju In
    • Economic and Environmental Geology
    • /
    • v.53 no.4
    • /
    • pp.337-346
    • /
    • 2020
  • This study was carried out to evaluate the applicability of the soil washing process to remediation mercury-contaminated mine tailing or solid material (soil and sediments etc.) around abandoned mines. First, the physicochemical characteristics of mine tailing were analyzed through particle size analysis and sequential extraction. Secondly, laboratory scale washing experiments were performed using hydrochloric acid, nitric acid, potassium iodide and sodium thiosulfate. As a results of particle size analysis, mine tailing particle were concentrated below 40 mesh and the particle size below 200 mesh was the most analyzed. As a result of sequential extraction, elemental mercury fraction was analyzed as the highest with 69.12%, with strongly bound fraction 15.25% and residual and HgS fractions 11.97%, respectively. Laboratory scale washing experiments showed low applicability for nitric acid and sodium thiosulfate solutions. In case of hydrochloric acid solution, it was analyzed that mercury removal was possible at particle size of 200 mesh or more. Therefore, it is considered to be performed together with the physical sorting process. Potassium iodide solution was analyzed to have high washing efficiency at all concentrations and particle sizes. In particular, the mercury removal efficiency is high in the micro particles, and thus the applicability of the washing technology is the highest.

The Feasibility Study of photoconductor materials for the use of a dosimeter in Radiotherapy (광도전체 물질의 치료 방사선 선량계 적용을 위한 가능성 연구)

  • Jang, Giwon;Shin, Jungwook;Oh, Kyungmin;Park, Sungkwang;Kim, Jinyoung;Park, Jikoon;Nam, Sanghee
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.81-84
    • /
    • 2013
  • The use of the dosimetry have been increasingly recognized as high radiation energy and radiation treatment planning(RTP) have rapidly developed in radiotherapy. There are many types of detectors for the dosimetry such as ionization chamber, film, TLD, diode, and etc. Among such detectors, the diode detector uses a photoconductor materials that generate electrical signals by the incident radiation energy. Though many research groups are recently interested in such materials, there is few experimental results except for silicon in the radiation therapy field. In this study, the feasibility of photoconductor materials was verified as a dosimeter through the evaluation of response properties at a high radiation energy. For the fabricated detectors based on $HgI_2$ and $PbI_2$, reproducibility, linearity, and pulse-rate response were analyzed. Such evaluations are essential factors for the use of dosimeter. From results, linearity and reproducibility of the fabricated $HgI_2$ detector indicated about 7% error. The fabricated $PbI_2$ detector showed 1.7% error in linearity, and 12.2% error in reproducibility.

The Evaluation and Fabrication of Photoconductor Sensor for Quality Assurance of Radiation Therapy Devices (방사선치료기기 정도관리를 위한 광도전체 센서 제작 및 평가)

  • Kang, Sang Sik;Noh, Sung Jin;Jung, Bong Jae;Noh, Ci Chul;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.565-569
    • /
    • 2016
  • Recently, a use of linear accelerator with a multi-leaf collimator(MLC) for radiation therapy is increasing. The importance of quality assurance (QA) for the linear accelerator is emphasized as the side effects of the inaccurate delivery of the radiation beam has been increased according to the high dose irradiation technique. In this study, The $HgI_2$ and $PbI_2$ photoconductor layer samples of $400{\mu}m$ thickness were fabricated using sedimentation method among particle-in-binder technology. From the fabricated samples, the electrical properties(dark current, output current, response properties and linearity) were investigated. From the experimental results, $HgI_2$ has good charge signal generation and linearity. Finally, from the signal response results about various thickness of $HgI_2$ sensor, the signal creation efficiency of $400{\mu}m$ thickness of $HgI_2$ sensor has the highest value and the excellent reproducibility below ${\pm}2.5%$.

Determination of Silver with Mercaptans (I). Amperometric Titration of Silver with 2,5-Dimercapto-1,3,4-Thiadiazole (Mercapto 화합물에 의한 은의 정량 (제1보) 2,5-Dimercapto-1,3,4-Thiadiazol에 의한 은의 전류 적정)

  • Young Gu Ha;Q. Won Choi
    • Journal of the Korean Chemical Society
    • /
    • v.17 no.2
    • /
    • pp.126-129
    • /
    • 1973
  • An amperometric method has been developed for the titration of silver with 2,5-dimercapto-1,3,4,-thiadiazole in ammonical solution (1N) using rotating platinum electrode as an indicator electrode and the mercury-mercury (II) iodide as reference electrode. Direct titration of milligram amount of silver (0.05-1.0mg) is possible in the presence of a number of foreign ions in ammonical solution containing ethylenediaminetetraacetic acid as masking agent under atmosphere. The interfering elements are gold and platinum. The milligram amount of silver can be determined by the proposed method within an error ${\pm}3{\%}$.

  • PDF

The Study on Applicability of Semi-conductive Compound for Radioactive Source Tracing Dosimeter in NDT Field (비파괴 검사 분야의 방사성 동위원소 위치추적을 위한 반도체 화합물의 적용 가능성 연구)

  • Shin, Yohan;Han, Moojae;Jung, Jaehoon;Kim, Kyotae;Heo, Yeji;Lee, Deukhee;Cho, Heunglae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.39-44
    • /
    • 2019
  • Radiation safety management is being considered very important since radioactive isotopes such as Co-60 and Ir-192 are widely used in fields such as non-destructive test(NDT). In this study, the applicability of Mercury(II) Iodide($HgI_2$) source for tracing system was evaluated. To make sure the unit cell sensor's reliability, we evaluated the electrical properties of the sensor made with $HgI_2$, and then position dependence of the sensor was analyzed and compared with the dose distribution from the planning system. As a result of the evaluation, high reliability of the sensor was shown through the linearity of R-sq > 0.990 and reproducibility of CV < 0.015. In the position dependence evaluation, the maximum value was measured at the isocenter of the sensor and gradually decreased according to the distance. However, the dose distribution data from the planning system was turned out that has difference with that of the sensor up to 30%. This seems to come from the difference between single-point measuring based planning system and area measuring based sensor.

Chemical Modification and Feedback Inhibition of Arabidopsis thaliana Acetolactate Synthase (아라비돕시스 탈리아나 Acetolactate Synthase의 화학적 변형과 되먹임 방해)

  • Hong, Seong-Taek;Choi, Myung-Un;Shin, Jung-Hyu;Koh, Eun-Hie
    • Applied Biological Chemistry
    • /
    • v.40 no.4
    • /
    • pp.277-282
    • /
    • 1997
  • Acetolactate synthase (ALS) was partially purified from Escherichia coli MF2000/pTATX containing Arabidopsis thaliana ALS gene. The partially purified ALS was examined for its sensitivity toward various modifying reagents such as iodoacetic acid, iodoacetamide, N-ethylmaleimide (NEM), 5,5'-dithiobis(2-nitrobenzoic acid) (DTNB), p-chloromercuribenzoic acid (PCMB), and phenylglyoxal. It was found that PCMB inhibited the enzyme activity most strongly followed by DTNB and NEM. Since iodoacetic acid did not compete with substrate pyruvate, it appeared that cysteine is not involved in the substrate binding site. On the other hand, the substrate protected the enzyme partly from inactivation by phenylglyoxal, which might indicate interaction of arginine residue with the substrate. The partially purified enzyme was inhibited by end products, valine and isoleucine, but not by leucine. However, the ALS modified with PCMB led to potentiate the feedback inhibition of all end products. Additionally, derivatives of pyrimidyl sulfur benzoate, a candidate for a new herbicide for ALS, were examined for their inhibitory effects.

  • PDF

Analytical Methods of Hydroxyl Radical Produced by TiO2 Photo-catalytic Oxidation (TiO2 광촉매 산화 반응에서 생성된 수산기 라디칼 분석 방법)

  • Kim, Seong Hee;Lee, Sang-Woo;Kim, Jeong Jin;Kim, Soon-Oh
    • Journal of the Mineralogical Society of Korea
    • /
    • v.28 no.3
    • /
    • pp.245-253
    • /
    • 2015
  • The performance of $TiO_2$ photo-catalytic oxidation process is significantly dependent on the amount of hydroxyl radicals produced during the process, and it is an essential prerequisite to quantify its production. However, precise and accurate methods for quantification of hydroxyl radicals have not been developed so far. For this reason, this study was initiated to compare existing methods for analysis of hydroxyl radicals produced by $TiO_2$ photo-catalytic oxidation and to propose a new method to overcome the limitation of established methods. To simulate $TiO_2$ photo-catalytic oxidation process, Degussa P25 which has been widely used as a standard $TiO_2$ photo-catalyst was used with the dose of 0.05 g/L. The light source of process was UVC mercury low-pressure lamp (11 W, $2,975mW/cm^2$). The results indicate that both potassium iodide (KI)/UV-vis spectrometer and terephthalic acid (TPA)/fluorescence spectrometer methods could be applied to qualitatively measure hydroxyl radicals via detection of triiodide ion ($I_3{^-}$) and 2-hydroxyterephthalic acid which are produced by reactions of iodine ion ($I^-$) and TPA with hydroxyl radicals, respectively. However, it was possible to quantitatively measure hydroxyl radicals using TPA method coupled with high-performance liquid chromatograph (HPLC). The analytical results using TPA/HPLC method show that hydroxyl radical of 0.013 M was produced after 8 hours operation of photo-catalytic oxidation under specific experimental conditions of this study. The proposed method is expected to contribute to precise the evaluation of the performance of photo-catalytic oxidation process.

The Fabrication and Evaluation of HgI2 Semiconductor Detector as High Energy X-ray Dosimeter Application (고에너지 X선 선량계 적용을 위한 TiO2 첨가된 요오드화수은 반도체 검출기 제작 및 평가)

  • Choi, Il Hong;Noh, Sung Jin;Park, Jung Eun;Park, Ji Koon;Kang, Sang Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.383-387
    • /
    • 2014
  • In this paper, for a new detection system development with the better accurate dose evaluation and beam distribution imaging using the small field irradiation of linear accelerator, the compound semiconductor based detection sensors were fabricated and the performance evaluation was investigated. The special particle-in-binder sedimentation was used for a large area film sensor fabrication. The detection properties for high energy x-rays were investigated from a dark current, an output current, a rising time, a falling time, and response delay measurement. The experimental results, the $TiO_2$ mixed $HgI_2$ sensor showed the best electrical characteristics than $PbI_2$, PbO, pure $HgI_2$. Linearity, repeatability, and accuracy tests from LINAC were tested, the $TiO_2$ mixed $HgI_2$ sensor showed the better performance than the commercially available dosimetry devices.