• Title/Summary/Keyword: 요오드계 소독제

Search Result 5, Processing Time 0.017 seconds

Dimensional stability of rubber impression materials immersed in iodophor disinfectant (요오드 소독제에 침전된 고무인상재의 체적안정성)

  • Choi, Mee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.23-27
    • /
    • 2014
  • Purpose: The purpose of this study was to determine the dimensional stability of three rubber impression materials (polysulfide, polyvinylsiloxane, polyether) in an iodophor disinfectant. Materials and Methods: Seventy-two impressions were made with each material and divided into control, 10-minute, and 30-minute immersion groups using an iodophor as the disinfectant. A microscope was used to measure dimensional changes in the stone casts made from each group of impressions, and the percent change was analyzed using a two-way ANOVA (P = 0.05). Results: All dimensional changes after iodophor disinfection were small in 10 minute groups, however, showed significantly increased in 30 minute groups (P < 0.05). Conclusion: Clinically, it can be recommended to use iodophor disinfectant for rubber materials within 10 minute.

Analysis of Trace Levels of Lodinated Trihalomethanes in Water Using Headspace - GC/ECD (Headspace - GC/ECD를 이용한 수중의 미량 요오드계 트리할로메탄류 분석)

  • Son, Hee-Jong;Song, Mi-Jung;Kim, Kyung-A;Yoom, Hoon-Sik;Choi, Jin-Taek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.1
    • /
    • pp.35-41
    • /
    • 2014
  • Trihalomethanes (THMs) are formed as a results of the reaction of residual chlorine, used as a disinfectant in drinking water, with the organic matter in raw water. Although chlorinated and brominated THMs are the most common disinfection byproducts (DBPs) reported, iodinated THMs (I-THMs) can be formed when iodide is present in raw water. I-THMs have been usually associated with several medicinal or pharmaceutical taste and odor problems and is a potential health concern since they have been reported to be more toxic than their brominated and chlorinated analogs. Currently, there is no published standard analytical method for I-THMs in water. An automated headspace-gas chromatography/electron capture detector (GC/ECD) technique was developed for routine analysis of 10 THMs including 6 I-THMs in water samples. The optimization of the method is discussed. The limits of detection (LOD) and limits of quantification (LOQ) range from 12 ng/L to 56 ng/L and from 38 ng/L to 178 ng/L for 10 THMs, respectively. Matrix effects in river water, sea water and wastewater treatment plant (WWTP) final effluent water were investigated and it was shown that the method is suitable for the analysis of trace levels of I-THMs, in a wide range of waters. The method developed in the present study has the advantage of being rapid, simple and sensitive.

Assessment of Both Standard and Isolated Vibrio parahaemolyticus on Efficacy of Commercial Sanitizers and Disinfectants (Vibrio parahaemolyticus 표준 및 식품분리 균주에 대한 살균소독제 유효성분별 감수성 평가)

  • Kim, Il-Jin;Kim, Yong-Su;Kim, Hyung-Il;Choi, Hyun-Chul;Jeon, Dea-Hoon;Lee, Young-Ja;Ha, Sang-Do
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.2
    • /
    • pp.127-131
    • /
    • 2007
  • This study evaluated the bactericidal effect of 10 sanitizers and disinfectants such as ethanol (75 and 95%), iodine (15 and 25 ppm), chlorine (100 and 200 ppm), quaternary ammonium, acid, hydrogen peroxide, and peroxide acetic acid against V. parahaemolyticus. Ten strains of V. parahaemolyticus isolated from Korean foods and 4 strains of standard V. parahaemolyticus were compared for efficacies of various sanitizers and disinfectants by EN 1276 method based on quantitative suspension test. Ethanol (75 and 95%), 25 ppm of iodine, 100 ppm of quaternary ammonium, 145 ppm of hydrogen peroxide and acid showed more than $5log_{10}CFU/mL$ reduction in both clean and dirty conditions. Tests result of chlorine (100 ppm) showed more than $5log_{10}CFU/mL$ reduction in clean condition. Iodine (15 ppm) showed more than $5log_{10}CFU/mL$ reduction except 4 isolated and 1 standard V. parahaemolyticus in clean condition. iodine (15 ppm) also showed under $5log_{10}CFU/mL$ reduction $(0.93{\sim}3.73log_{10}CFU/mL)$ in dirty condition. Eleven hundred ppm of hydrogen peroxide was evaluated as weak sanitizer and disinfectant due to their $0.99{\sim}4.79log_{10}CFU/mL$ reduction on both clean and dirty conditions. Consequently, ethanol, iodine (25 ppm), chlorine (200 ppm), quaternary ammonium, acid and peroxide acetic acid were thought to be effective sanitizer and disinfectant against V. parahaemolyticus.

Inhibitory Effect of Aerosolized Commercial Sanitizers against Foodborne Pathogens (에어로졸 형태의 상업적 살균소독제의 병원성 미생물에 대한 저해효과 평가)

  • Lee, Sun-Young;Jung, Jin-Ho;Jin, Hyun-Ho;Kim, Young-Ho;Oh, Se-Wook
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.4
    • /
    • pp.235-242
    • /
    • 2007
  • This study was conducted to investigate the effect of aerosolized chemical sanitizers on inhibiting foodborne pathogens such as Escherichia coli O157:H7, Salmonella typhimurium, and Listeria monocytogenes. Five domestic commercial sanitizers subjected to five groups of sanitizer (chlorine-based, hydrogen peroxide-based, Iodophor-based, quaternary ammonium-based, and alcohol-based sanitizers) were aerosolized by an aerosol generator into a model cabinet and treated in laboratory media containing three pathogens for 1 h at room temperature. Aerosolized hydrogen peroxide-based and quaternary ammonium-based sanitizers were effective at inhibiting levels of E. coli O157:H7 (ca. 4-9 log reductions) whereas other aerosolized sanitizers such as chlorine-based, Iodophor-based, and alcohol-based sanitizers did not significantly reduced the levels of E. coli O157:H7. For S. typhimurium, the only aerosolized hydrogen peroxide-based sanitizer was effective and resulted in ca. 5-9 log reduction. Aerosolized hydrogen peroxide-based, Iodophor-based, and quaternary ammonium-based sanitizers significantly reduced levels of L. monocytogenes and especially, aerosolized quaternary ammonium-based sanitizer was strongly effective to kill L. monocytogenes, resulted in higher than 8.8 log reduction. And there was no special trend in inhibitory efficacy of sanitizers aerosolized by 1.6 or 2.4 MHz aerosol generators. From these results, aerosolization has great potential for use in commercial applications however it's efficacy could be very different depending on type of sanitizers.

Factors Affecting the Formation of Iodo-Trihalomethanes during Chlorination in Drinking Water Treatment (정수처리에서 염소 처리시 요오드계 트리할로메탄류 생성에 영향을 미치는 인자들)

  • Son, Hee-Jong;Yoom, Hoon-Sik;Kim, Kyung-A;Song, Mi-Jeong;Choi, Jin-Taek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.8
    • /
    • pp.542-548
    • /
    • 2014
  • Effects of bromide ($Br^-$) and iodide ($I^-$) concentrations, chlorine ($Cl_2$) doses, pH, temperature, ammonia nitrogen concentrations, reaction times and water characteristics on formation of iodinated trihalomethanes (I-THMs) during oxidation of iodide containing water with chlorine were investigated in this study. Results showed that the yields of I-THMs increased with the high bromide and iodide level during chlorination. The elevated pH significantly increased the yields of I-THMs during chlorination. The formation of I-THMs was higher at $20^{\circ}C$ than $4^{\circ}C$, $10^{\circ}C$ and $30^{\circ}C$. In chloramination study, addition of ammonium chloride ($NH_4Cl$) markedly increased the formation of I-THMs. Among the water samples collected from seven water sources including wastewater treatment plant (WWTP) effluent water (EfOM water), prepared humic containing water (HA water) and algal organic matter (AOM) containing water (AOM water), EfOM water generated the highest yields of I-THMs ($12.31{\mu}g/mg$ DOC), followed by HA water ($4.96{\mu}g/mg$ DOC), while AOM water produced the lowest yields of I-THMs ($0.99{\mu}g/mg$ DOC). $SUVA_{254}$ values of EfOM water, HA water and AOM water were $1.38L/mg{\cdot}m$, $4.96L/mg{\cdot}m$ and $0.97L/mg{\cdot}m$, respectively. The I-THMs yields had a low correlation with $SUVA_{254}$ values ($r^2$ = 0.002).