• Title/Summary/Keyword: 외피시스템

Search Result 74, Processing Time 0.03 seconds

Energy Performance Evaluation of a Double-skin Facade with a Venetian Blind in Residential Buildings (주거건물용 이중외피 시스템의 블라인드 조절에 따른 에너지 성능평가에 관한 연구)

  • Lee, So-Yeun;Kang, Jae-Sik;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.1-9
    • /
    • 2010
  • Apartment balcony has been remodeled since the government permitted remodeling in January 2006.But extended balcony has great impact on building heat gain and loss. Therefore It has problems such as increase of heating and cooling energy. So $\underline{t}echnical$ solutions about window solar gain in summer is an urgent matter. The Purpose of this study is to evaluate energy performance of a blind in a double-skin facade in residential buildings by using EnergyPlus program. The results show that slat angles of $90^{\circ}$ is best in energy performance if we do not consider daylight. Poorly daylighted living room needs electric light and it also causes high cooling load. On the other hand, the results show that the application of blinds controlled automatically is best for energy performance when we consider daylight. Blind slat angles of $50\sim60^{\circ}$ have best performance when blinds are controlled in this angle throughout the day on a clear day in August. Blind slat angles of $0\sim30^{\circ}$ have best performance when blinds $\underline{are\;controlled}$ in this angle throughout the day on a cloudy day (more than 7 of total sky cover) in August.

A Study on The Modulor System Shown in Structure and Envelope of Le Corbusier's Works (Le Corbusier 건축의 구조와 외피에 나타나는 모듈러 시스템에 관한 연구)

  • Cho, Sung-Hyun
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.10 no.1
    • /
    • pp.15-22
    • /
    • 2010
  • As for structural system, which constitutes his construction, there are column inside dimension and span which constitutes plane, and as for constructions for section, there are C.H and slab, and as for constructive factors for envelope, there are window and closing panel of outer wall, and as for opening, there are punching window and wave window. With these constructive parts and opening of envelope, his construction composes volume and mass. The relation of structure and modulor which are shown in his later construction can be divided in two cases that modulor is directly and indirectly adapted for rate and measure calculation of the constructive body. As for indirectly adapted case, we can find it form most of his later construction, it is living place in which human beings life is, and it is adapted mainly for small space. In his construction, he tried to tell human scale and sense of musical rhythm through modulor. In other words, he played sense of space and musical scale by adapting regular and repetitive modulor of opening, and in small space for daily life, he made the size of space into the space which human can perceive. And, if we interpret mudulor in modern meaning, it is an establishment of radius of human act. And, we can make organic and harmonic design of space if we use modulor as origin of human centered measurement calculation, and if we adapt space after dividing by use.

Study on Indoor Thermal Performance Analysis upon PCM Temperature applicable to the Double Skin Facade System in the Winter (동절기 이중외피 시스템에 적용 가능한 PCM재료의 온도설정에 따른 실내 열 성능 분석에 관한 연구)

  • Ryu, Ri;Seo, Jang-hoo;Kim, Yong-seong
    • KIEAE Journal
    • /
    • v.15 no.3
    • /
    • pp.43-48
    • /
    • 2015
  • Purpose: Recently, many countries around the world are actively looking for the ways to make full use of natural energy sources and also develop and apply an environmentally friendly system designed to save building energy consumption. Under these circumstances, this study intended to determine the applicability and energy saving effect by deriving the indoor thermal performance characteristics and the PCM temperature appropriate for a double skin façade to reduce indoor energy consumption through the application of different PCM temperatures to double skin façade and perform a performance evaluation depending on the application or non-application of PCM to a double skin façade. Method: For this study, the physical variables of the double skin façade with PCM were configured through a preliminary examination based on an experimental measurement, and experimental measurements were taken with a total of 7 types of mockup cases: Type-1 (Basic), the basic double skin façade, Type-2 (PCM $18^{\circ}C$) which was applied to the inner skin of the double skin façade depending on the phase-change temperature of PCM, Type-3 (PCM $20^{\circ}C$), Type-4 (PCM $22^{\circ}C$), Type-5 (PCM $24^{\circ}C$), Type-6 (PCM $26^{\circ}C$), and Type-7 (PCM $28^{\circ}C$) with reference to the data analysis of the basic double skin façade which preceded this study, to analyze the indoor thermal performance of the double skin façade depending on PCM temperature and the installation or non-installation of a double skin façade applying PCM based on the selected unit space. Result: Indoor thermal performance was analyzed depending on the PCM temperature applicable to double skin façade, and the analysis of heating energy reduction showed that Type-2 (PCM $18^{\circ}C$) gained 15.9% more heat compared with Type-1 (Basic) and secondly, Type-3 (PCM $20^{\circ}C$) gained 11.5% more heat. Based on these findings, it is deemed possible that the use of energy for heating can be reduced when heat coming indoors increases during the heating period, and the appropriate temperature for PCM applied to the inner skin of a double skin façade to reduce heating energy in winter, Type-2 (PCM $18^{\circ}C$) showed the highest efficiency and Type-3 (PCM $20^{\circ}C$) was also deemed appropriate.

Control Efficiency of a Daylight Dimming System for Indirect Lighting in a Small Office (소규모 사무실 공간에서 간접조명에 대한 조광제어 시스템효율)

  • Kim, Soo-Young;Jung, Yong-Ho;Sohn, Jang-Yeul
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.3
    • /
    • pp.33-43
    • /
    • 2006
  • Daylight dimming control system was analyzed for an indirect lighting system in a small office space with a double skin envelope system. Computer simulations were performed for photosensors with three shielding conditions. The photosensors were placed on the center of ceiling, and backwall. Three sky conditions defined by CIE were considered. Overall, control performance was not very excellent for all conditions. Fully-shielded photosensor achieved good control performance for some cases, but partially-shielded and unshielded photosensors failed to achieve target illuminance. The variation in desktop illuminance due to daylight was examined for a variety of daylight conditions. Linear correlation between desktop illuminance and photosensor illuminance was analyzed using ANOVA.

Modal Analysis and Failure Safety Estimation for the Satellite Antenna System Composed of Sandwich Structure with Laminated Face Sheet (적층된 외피를 갖는 샌드위치로 구성된 위성체 안테나 시스템의 모드 해석과 파손안전성 판별)

  • Oh, Se-Hee;Han, Jae-Hung;Oh, Il-Kwon;Shin, Won-Ho;Kim, Chun-Gon;Lee, In;Park, Jong-Heung
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.228-233
    • /
    • 2001
  • Satellite system experiences severe mechanical loads during the launch period. Therefore, positive margin of safety of the satellite system must be demonstrated for every possible mechanical loading condition during the launch period. This paper presents modal and stress analysis result due to quasi-static loads for the satellite antenna system. The failure tendency for the sandwich construction of the satellite antenna system has been studied with various lamination angles of unidirectional prepreg.

  • PDF

A Study on Natural Ventilation Performance for a Double-Skin Facade System in Apartment Buildings (이중외피시스템을 적용한 고층 주거용건물의 자연환기 성능평가)

  • 석호태;김동화;최정민
    • Journal of the Korean housing association
    • /
    • v.14 no.3
    • /
    • pp.119-126
    • /
    • 2003
  • The purpose of this study is to evaluate the natural ventilation performance for variable external wind speed as a preliminary step to determining the seasonal operating modes of the Double-skin Facade System applied to apartment buildings. For this purpose, two simulation programs are used to compare the Double-Skin Facade System with the Double Sash Window. First, TAS is used to plan a schedule for natural ventilation during the intermediate season and to analyze the cooling loads. Second, CFD is used for a more detailed airflow analysis on a typical floor plan of the model building. The results of the simulations on natural ventilation performance show that the Double-Skin Facade System can reduce the cooling load by 10.5% compared to the Double Sash Window.

Numerical Simulation on Thermal Performence of Passive Ventilation Skin (패시브환기외피의 열성능 수치시뮬레이션)

  • Lee, Tae-Cheol;Son, Yu-Nam;Yoon, Seong-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.144-149
    • /
    • 2011
  • This study aims to evaluate performance of ventilation and thermal about breathing wall by flowing air to indoor on appropriate conditions that is effective aperture area in the Central region(20, 50, $80cm^2/m^2$). The result is as follows : 1) Sectional temperature distribution of inflow and outflow out under the constant ventilation was reviewed. In the case of inflow, outside temperature increase effect was confirmed. 2) The more differences of temperature between outdoor and indraft of air was high, the more heat recovery was high.

  • PDF

Thermal Buckling Characteristics for Thermal Protection System Panel Using Ritz Method (리츠 법을 이용한 열방어 시스템 패널의 열 좌굴 특성 연구)

  • Lee, Heesoo;Kim, Yongha;Park, Jungsun
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.1
    • /
    • pp.18-28
    • /
    • 2019
  • High speed vehicles are subjected to high thermal loadings due to aerodynamic heating during ascent and reentry. Since a thermal protection system panel is mechanically constrained, it may cause thermal buckling under excessive thermal loadings. The thermal buckling could disturb the field of flow and make aerodynamic characteristics unstable. It is thus necessary to design the thermal protection system panel to prevent thermal buckling. This study defines the analytical model of temperature distribution using the finite difference method for the thermal protection system panel with large temperature differences inside and outside. This paper proposes the approximate model of the thermal buckling characteristics for the thermal protection system panel through the use of the Ritz method. The validity of the present method was verified by comparing the results of the finite element analysis. Furthermore, this research performs the parametric analysis of the thermal buckling characteristics for the thermal protection system panel by using the approximate model.

Optimal Manufacturing of Composite Wing Ribs in Solar-Powered UAVs: A Study (태양광 무인기 복합재 윙 리브 최적 제작 연구)

  • Yang, Yongman;Kim, Myungjun;Kim, Jinsung;Lee, Sooyong
    • Journal of Aerospace System Engineering
    • /
    • v.10 no.4
    • /
    • pp.50-58
    • /
    • 2016
  • In our preceding study, we reported that the use of light, composite-material wings in long-endurance Solar-Powered UAVs is a critical factor. Ribs are critical components of wings, which prevent buckling and torsion of the wing skin. This study was undertaken to design and manufacture optimal composite ribs. The ribs were manufactured by applying laminated-layer patterns and shapes, considering the anisotropic properties of the composite material. Through the finite element analysis using the MSC Patran/Nastran, the maximum load and the displacement shape were identified. Based on the study results measured by structural tests, we present an optimal design of ribs.

A Preliminary Study on Outer Shell Plan through Element Technologies in Eco-friendly Architecture -Focused on Works of Norman Foster - (친환경 건축에서의 요소기술을 통한 외피계획에 관한 기초연구 -노먼 포스터(Norman Foster) 작품을 중심으로-)

  • Ryu, Ri;Seo, Jang-Hoo;Kim, Yong-Seong
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.13 no.4
    • /
    • pp.69-76
    • /
    • 2013
  • As the energy consumed in building area has occupied a lot when looking into energy usage weights in area over the world, energy reduction building, eco-friendly architecture comes to the fore in the modern architecture. Discussions on the eco-friendly architecture have various concept definitions and targets to be achieved.The architectural works of Norman Foster are expressed as high-tech buildings using iron, glass, etc. in appearance, but they appear as those buildings with low energy load by analyzing environmental conditions from initial design stage that each building has, utilizing natural energy with design of outer shell and applying proper technical system. Thus, this study aims at providing basic data of outer shell planning through eco-friendly element technologies by considering pattern and outer shell design of buildings, principles of eco-friendly building plan as an eco-friendly building planning technique of Norman Foster as an example of plans to utilize building pattern, outer shell design and natural environments, in order to utilize passive measures as much as possible to increase energy saving methods and increase comfort by analyzing element technologies in the eco-friendly architecture in line with the modern flow.