• Title/Summary/Keyword: 외피단열

Search Result 51, Processing Time 0.023 seconds

A Study on the Non-residential Building Envelope Remodeling for Energy Efficiency (비주거용 건물의 외피 리모델링을 통한 에너지성능향상 방안에 관한 연구)

  • Jang, Hyun-Sook;Lee, Sang-Ho
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.6
    • /
    • pp.3-12
    • /
    • 2012
  • The slowdown of private building industry resulted in growth of remodeling market as a way to improve energy performance. Remodeling is considered more cost-effective and eco-friendly approach for energy efficient building than new construction. Since 2008, Seoul has promoted Building Retrofit Project (BRP) preponderantly to attract energy-saving renovation by supporting building owners to switch building system into energy-saving system when they remodel their old buildings. According to 2012 press release, 254 Private sectors participated in this green building project and annually reduced 41000ton of greenhouse gas emission, 14000TOE, which also result in 7.5 billion won energy cost savings per year. The paper focuses on the building envelope remodeling as a way to improve energy efficiency. Different components of the building envelope such as wall insulation, window, and shading, were applied to the baseline model and the comparison was analyzed to come up with the ideal solution. This study only assesses the building envelope as to suggest the way to redesign the better energy performing building. Offering solution focusing on the architectural feature is essential because it will provide basic information and standard when remodeling a building for energy efficiency, especially, for the nonresidential buildings used as rental offices.

Thermal Effect of the Transparent Insulated Opaque Envelopes (투명 단열외피의 열적성능에 관한 연구)

  • Kim, Se-Hwan;Lee, Sung
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.4 no.4
    • /
    • pp.19-24
    • /
    • 2004
  • The thermal effect of a transparent insulated opake wall with solar energy was investigated theoretically. The heat gain through transparent insulated opake wall was studied for relative simple conditions. The stationary heat transport effect was studied for layer which is built on the opake wall. This study shows that a relative low solar radiation intensity causes a great heat reduction through the transparent insulated opake wall. Because the transparent insulation layer is mostly transparent to solar radiation, it is opaque to heat radiation.

  • PDF

Thermal Performance of Building Envelope with Transparent Insulation Wall (건물 외피 투과형단열 벽체의 열성능 해석 연구)

  • Jang, Yong-Sung;Yoon, Yong-Jin;Park, Hyo-Soon
    • KIEAE Journal
    • /
    • v.5 no.1
    • /
    • pp.27-33
    • /
    • 2005
  • Global efforts have made to reduce energy consumption and $CO_2$ gas emission. One of the weakest parts for energy loss through the whole building components is building envelopes. Lots of technologies to increase the thermal performance of building envelopes have been introduced in recent year. Transparent Insulation Wall(TIW) is a new technology for building insulation and has been function both solar transmittance and thermal insulation. A mathematical model of a Transparent Insulation Wall equipped with south wall was proposed in order to predict thermal performance under varying climates(summer and winter). Unsteady state heat transfer equations were set up using an energy balance equation and solved using Gauss-Seidel iteration solution procedure. The thermal performance of the TIW determined from a wall surface and air layer temperature, non-airconditioned room temperature and air conditioning load. As a result, this numerical study shows that the TIW is effective in an air conditioning load reduction. Further experimental study is required to establish complete TIW system.

Thermal Performance of TI-wall System (투과형단열재 부착 건물외피구조체의 열성능)

  • Yoon, Yong-Jin;Kim, Hea-Jeong;Kim, Byoung-Soo
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.121-128
    • /
    • 2004
  • One of the most weak parts for energy loss through the whole building components are building envelopes. Lots of technbologies to increase the thermal performance of building envelopes have been introduced in recent years. Transparent insulation is a new technology for building insulation and has function both solar transmittance and thermal insulation. This study has been carried out to develope the transparent insulation panels and TI-wall system and to analyze the thermal performance of TI-wall system by experiments using test-cell and dynamic energy simulation program ESP-r 9.0. This system is regarded as a efficient building envelope system suitable for to reduce the heating and cooling load of the buildings in our country.

Study on the palstic green houses depending on regional weather conditions (지역기후특성을 고려한 비닐온실에 관한연구)

  • Woo, Byung Kwan;Lee, Sung;Kim, Se Hwan;Kim, Sam Yeol
    • KIEAE Journal
    • /
    • v.9 no.5
    • /
    • pp.39-46
    • /
    • 2009
  • Most Plastic Green Houses in Korea are made according the European weather condition, which lead to have very low solar energy efficiency. Moreover, the function of green houses, as well as the structure of them, has not changed for Korean weather condition. Therefore, the structure and function of them should adopt the regional weather condition in order to improve the energy efficiency. This paper investigates the current plastic green housesin Korea, and presents an alternative for improving the energy efficiency. The elements of green houses were investigated. When using a partial opaque insulation with a thermal storage body, the difference of indoor air temperature became 20C during daytime, and 5C during night, which will save massive fossil fuels.

Study on the Energy Saving for School Buildings - through thermal effect of the transparent insulated opaque envelopes - (학교건물의 에너지 절약에 관한 연구 - 투명 단열외피의 열적성능을 중심으로 -)

  • Lee, S.;Kim, S.H.;Kim, K.C.
    • Journal of Power System Engineering
    • /
    • v.10 no.1
    • /
    • pp.41-45
    • /
    • 2006
  • The thermal effect of a transparent insulated opake wall with solar energy was investigated theoretically. The heat gain through transparent insulated opake wall was studied for relative simple conditions. The stationary heat transport effect was studied for layer which is built on the opake wall. This study shows that a relative low solar radiation intensity causes a great heat reduction through the transparent insulated opake wall.

  • PDF

Cyclic Structural Characteristics of Thermal Bridge Breaker Systems embedded in Reinforced Concrete Slabs (벽-슬래브 접합부에 매립된 열교차단장치의 반복하중에 대한 거동특성 평가)

  • Shin, Dong-Hyeon;Oh, Moung-Ho;Kim, Young-Ho;Kim, Hyung-Joon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.5
    • /
    • pp.511-521
    • /
    • 2015
  • The thermal bridge occurring in a building influences its thermal performance and durability. The domestic typical multi-unit residential buildings suffer thermal losses resulting from thermal bridges of the balcony slab. To minimize the thermal loss between inside and outside of the balcony slab, thermal bridge breaker(TBB) systems have been developed and applied in building construction. Although thermal bridge breaker systems for reinforced concrete(RC) wall-slab joints can improve the thermal performance of a building, it is necessary to verify the structural performance of TBB systems whether they provide proper resistance for cyclic loading. In order to investigate the structural characteristics of TBB systems embedded in RC slabs, cyclic tests of wall-slab joints were performed by applying two reversed cycles at each up to 30 cycles. The test results show that the RC slabs embedding TBBS systems can present excellent structural performance and the maximum moment capacity, energy dissipation capacity and ductility of TBBs systems are enhanced compared to those of the typical RC slabs.

Insulation Details and Energy Performance of Post-Beam Timber House for Insulation Standards (단열 기준에 따른 기둥-보 목조주택의 단열 상세 및 에너지 성능)

  • Kim, Sejong;Park, Joo-Saeng
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.876-883
    • /
    • 2015
  • Han-green project, which pursues Korean style post and beam timber house with traditional construction technique of Han-ok, has been carried out in KFRI (Korea Forest Research Institute) since 2006. Recently, the improvement of its building energy performance was studied with energy-saving elements. This study was conducted to provide the insulation details of building envelopes in a post-beam timber house for recent enhanced insulation standards and following effect on building energy performance. The level of thermal transmittance (U-value) values of building envelopes was composed of two stages: present Korean insulation standards and passive house. To evaluate building energy performance, the building airtightness values of two stages was ACH50 = $3.0h^{-1}$ for common domestic timber house constructed recently, and ACH50 = $0.6h^{-1}$ for passive house. Consequently, four cases of the building energy performance according to the combination of U-value with airtightness were evaluated. The test house for evaluation was located in Seoul and its energy performance was evaluated with CE3 commercial building energy simulation program. The result showed that enhanced insulation from level I to II reduced $14kWh/(m^2{\cdot}a)$ of annual heating energy demand regardless of airtightness.

Indoor Visual Environmental Estimate Experiment Evaluation of See Through BIPV Curtainwall System (가시성확보 BIPV 커튼월시스템의 실내 시환경 예측 시험 평가)

  • Cha, Kwangseok;Jo, Boram
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.108-108
    • /
    • 2011
  • 공동주택에서 2025년 정부가 추진하고 있는 Zero Energy 건축물 구현과 친환경에 대한 탄소배출 저감 문제로 재생에너지 생산시스템의 추가 적용은 반드시 필요하다. 따라서 공동주택 적용 및 활용성을 높일 수 있는 BIPV시스템 개발을 통하여 설치면적 확보와 세대 활용성을 높일 수 있도록 하는 것이 필요하다. 특히 거실 창호의 경우 주방향이 남향, 남동 또는 남서향으로 배치되어 태양광을 적용하기에 적합한 특성을 가지고 있다. 그러나 창호는 건물외피의 역할과 재실자가 조망과 정보취득을 얻을 수 있는 중요한 통로가 되기 때문에 단열 문제나 시야 차폐의 문제는 발생하지는 않도록 하는 것이 필요하다. 본 연구에서는 a-si타입 모듈 2개를 10% 투과율로 Bsck Coating 색상을 달리한 모듈과 c-si BIPV 모듈을 커튼월 창호시스템으로 개발, 일반 2중 창호시스템과 비교 평가를 위해 실제 Test bed 건물에 시공하여 시환경 및 실내 창측면 온도변화 측정 분석을 진행하였다. 현재 국내외 출시되고 있는 a-si see through 모듈은 10~30%의 투과율로 창 마감재로 대체가 가능하나 건축 환경(시환경,열환경)에 대한 분석은 전무한 상태이다. 본 연구에서는 시환경과 창유리면의 열 부하, 자외선, 적외선 차폐 및 가시광선의 투과율에 대한 평가와 Back Coating에 따른 색온도 평가를 통해서 a-si BIPV의 공동주택 세대 발코니 창호 적합성에 대한 검토를 진행하였다. 연구결과는 아래와 같다. ${\bullet}$ 실내조도는 청천공 정오기준 가시성 확보 모듈의 경우 2,300 ~ 3,500lx를 나타내고 있어 대비 현상이나 창측의 급격한 조도 변화가 적은 시환경 구축이 가능 ${\bullet}$ 12시경 휘도는 창측면, 실내 벽체, 코너 바닥면을 대상으로 a-si BIPV 모듈을 적용한 경우 휘도비가 12:1로 KS나 IESNA의 광원과 근접면의 비 20:1 범위에 모두 존재, 적합한 것으로 분석되었으나 c-si의 경우는 그림자로 인한 대비 현상이 발생, 작업 시환경 문제 발생. ${\bullet}$ 이중시스템 창호와 비교하여 단열 성능 떨어짐. 발전시간대 창유리 면 온도 상승 으로 하절기 냉방부하 증가. ${\bullet}$ 자외선은 100% 가까이 차단, 적외선은 13~42%만 투과되고 가시광선은 13% 투과율을 나타내어 일반 창에 칼라 코팅을 적용하는 것과 유사한 경향을 나타냄.

  • PDF