• Title/Summary/Keyword: 외장재용 풍압계수

Search Result 3, Processing Time 0.017 seconds

Characteristics of Peak External Pressure Acting on the Roof and Wall of the Low-Rise Buildings with Gable Roofs (박공지붕형 저층건축물의 지붕 및 벽면에 작용하는 피크외압의 분포 특성)

  • Jo, Won Geun;Won, Jong Ho;Ha, Young Cheol
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.3
    • /
    • pp.245-255
    • /
    • 2009
  • The low-rise buildings with gable roofs are commonly used in a number of industries. In order to study the characteristics of peak external pressure coefficient on low-rise buildings with gable roofs, wind-tunnel test have been carried out. Wind-induced pressures were measured simultaneously at many points on wind-pressure models, typical of simple low-rise buildings with gable roofs, which have seven different roof slope with constant width(D), height(H), and length(D). The pressure measurements were made in one kind of turbulent boundary layer, which simulated the natural winds over typical suburban terrains at a geometric scale of 1/150. The results indicate that peak external pressure coefficient on the roof and wall edges were increased. The results compared with wind standard of KBC-2005 and standards of various nations. The comparative resultant, experimental result appeared very similar at AIJ-2004. But the results were somewhat larger then wind standard of KBC-2005.

Analysis of External Peak Pressure Coefficients for Cladding in Elliptical Retractable Dome Roof by Wind Tunnel Test (풍동 실험을 통한 타원형 개폐식 돔 지붕의 외장재용 풍압 계수 분석)

  • Lee, Jong-Ho;Kim, Yong-Chul;Cheon, Dong-Jin;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.1
    • /
    • pp.49-59
    • /
    • 2020
  • This study investigates the wind pressure characteristics of elliptical plan retractable dome roof. Wind tunnel experiments were performed on spherical dome roofs with varying wall height-span ratios (0.1~0.5) and opening ratios (0%, 10%, 30% and 50%), similar to previous studies of cirular dome roofs. In previous study, wind pressure coefficients for open dome roofs have been proposed since there are no wind load criteria for open roofs. However, in the case of Eeliptical plan retractable dome roof, the wind pressure coefficient may be largely different due to the presence of the longitudinal direction and transverse direction. The analysis results leads to the exceeding of maximum and minimum wind pressure coefficients KBC2016 code.

Comparison of Wind Pressure Coefficient and Wind Load Standard for Cladding in a Retractable Dome Roof by Wind Tunnel Test (풍동 실험을 통한 개폐식 돔 지붕의 외장재용 풍압 계수와 풍하중 기준 비교)

  • Cheon, Dong-jin;Kim, Yong-Chul;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.3
    • /
    • pp.125-132
    • /
    • 2018
  • The biggest impact on the cladding design of buildings is wind loads. Wind tunnel tests were conducted to examine the applicability of current wind load standards about membrane retractable roof spatial structure. A dome model with a circular shape that is retractable to the center of the dome was made (Opening ratio = 0, 10, 30, 50). In addition, height adjustable turntables were made and tested with five patterns with H/D = 0.1, 0.2, 0.3, 0.4 and 0.5. The maximum wind pressure coefficient and the minimum wind pressure coefficient for the cladding were analyzed and the experimental wind pressure coefficient were compared with the current wind load standards, KBC2016 and AIJ-RLB(2015). The experimental value and the reference value of the enclosed roof were very similar and showed possibility of application, but opened roof case was found that the reference value was underestimated.