A Study on the Reduction of Scattered Ray in Outside Radiation Field (조사야 외부의 산란선량 감소 방법에 관한 연구)

  • Je, Jaeyong;Jang, Howon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.539-543
    • /
    • 2016
  • In this research, The way to decrease a patient's exposure dose by reducing the scattered radiation dosage outside a radiation field with an diagnosis X-ray was examined. The scattered radiation dosage reaching other parts outside the radiation field was to be reduced by attaching a self-produced $150{\times}190mm^2$ lead plate to the lower part of a collimator. When a lead plate was inserted additionally and the scattered radiation dosage of the X axis was measured in the direction of the central X-ray axis, It was found out to have been decreased by 26 to 36%, and in the direction of Y axis, which was vertical direction from the central axis, The scattered radiation dosage depending on whether a lead plate was used or not displayed no large differences. These results shows that the impact of the scattered radiation by the off focus X-ray that was generated around the focus was bigger than that generated by the shutter of the collimator. Therefore it has been concluded that installing an additional lead plate in the lower part of the existing collimator can decrease the scattered radiation dosage outside a radiation field.

Evaluation of Radiation Exposure to Nurse on Nuclear Medicine Examination by Use Radioisotope (방사성 동위원소를 이용한 핵의학과 검사에서 병동 간호사의 방사선 피폭선량 평가)

  • Jeong, Jae Hoon;Lee, Chung Wun;You, Yeon Wook;Seo, Yeong Deok;Choi, Ho Yong;Kim, Yun Cheol;Kim, Yong Geun;Won, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.44-49
    • /
    • 2017
  • Purpose Radiation exposure management has been strictly regulated for the radiation workers, but there are only a few studies on potential risk of radiation exposure to non-radiation workers, especially nurses in a general ward. The present study aimed to estimate the exact total exposure of the nurse in a general ward by close contact with the patient undergoing nuclear medicine examinations. Materials and Methods Radiation exposure rate was determined by using thermoluminescent dosimeter (TLD) and optical simulated luminescence (OSL) in 14 nurses in a general ward from October 2015 to June 2016. External radiation rate was measured immediately after injection and examination at skin surface, and 50 cm and 1 m distance from 50 patients (PET/CT 20 pts; Bone scan 20 pts; Myocardial SPECT 10 pts). After measurement, effective half-life, and total radiation exposure expected in nurses were calculated. Then, expected total exposure was compared with total exposures actually measured in nurses by TLD and OSL. Results Mean and maximum amount of radiation exposure of 14 nurses in a general ward were 0.01 and 0.02 mSv, respectively in each measuring period. External radiation rate after injection at skin surface, 0.5 m and 1 m distance from patients was as following; $376.0{\pm}25.2$, $88.1{\pm}8.2$ and $29.0{\pm}5.8{\mu}Sv/hr$, respectively in PET/CT; $206.7{\pm}56.6$, $23.1{\pm}4.4$ and $10.1{\pm}1.4{\mu}Sv/hr$, respectively in bone scan; $22.5{\pm}2.6$, $2.4{\pm}0.7$ and $0.9{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. After examination, external radiation rate at skin surface, 0.5 m and 1 m distance from patients was decreased as following; $165.3{\pm}22.1$, $38.7{\pm}5.9$ and $12.4{\pm}2.5{\mu}Sv/hr$, respectively in PET/CT; $32.1{\pm}8.7$, $6.2{\pm}1.1$, $2.8{\pm}0.6$, respectively in bone scan; $14.0{\pm}1.2$, $2.1{\pm}0.3$, $0.8{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. Based upon the results, an effective half-life was calculated, and at 30 minutes after examination the time to reach normal dose limit in 'Nuclear Safety Act' was calculated conservatively without considering a half-life. In oder of distance (at skin surface, 0.5 m and 1 m distance from patients), it was 7.9, 34.1 and 106.8 hr, respectively in PET/CT; 40.4, 199.5 and 451.1 hr, respectively in bone scan, 62.5, 519.3 and 1313.6 hr, respectively in myocardial SPECT. Conclusion Radiation exposure rate may differ slightly depending on the work process and the environment in a general ward. Exposure rate was measured at step in the general examination procedure and it made our results more reliable. Our results clearly showed that total amount of radiation exposure caused by residual radioactive isotope in the patient body was neglectable, even comparing with the natural radiation exposure. In conclusion, nurses in a general ward were much less exposed than the normal dose limit, and the effects of exposure by contacting patients undergoing nuclear medicine examination was ignorable.

  • PDF

Evaluation of Stability using Monte Carlo Simulation in 2 People Isolation Treatment Room of Radiation Iodine (몬테카를로 모의 모사를 이용한 방사성옥소 2인 치료병실의 안전성 평가)

  • Jang, Dong-Gun;Ko, Sung-Jin;Kim, Chang-Soo;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.385-390
    • /
    • 2016
  • Radioactive iodine treatment that uses the 2 people isolation room is to cause unnecessary radiation exposure between patients. This research is to be tested safety of 2 people Isolation treatment room and dose-rate through conservative perspective except physiology characteristic and biology information on the assumption that patient have iodine without excretion in 2 people isolation treatment room. This research shows that 364 keV gamma rays emitted by the radioiodine was to determine that the air layer about 30 cm or lead shield 3 mm a half-layer. In addition, In addition, patients in the distance, and lead shielding, length of hospital stay (48 hours) for external radiation exposure that is received from the other patients, two of treatment as appears to be lower than the legal isolation standard dose less than 5 mSv isolation room effective analyzed that manageable.

Development of Portable Memory Type Radiation Alarm Monitor (휴대용 메모리형 방사선 경보장치 개발)

  • Son, Jung-Kwon;Lee, Myung-Chan;Song, Myung-Jae
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.4
    • /
    • pp.263-272
    • /
    • 1997
  • A Radiation Alarm Monitor has been developed and manufactured in order to protect radiation workers from over-exposure. A visual and audible alarm system has been attached to initiate evacuation when accident occurs such as an unexpected change of radiation level or an over-exposure. The Radiation Alarm Monitor installed with microprocessor can record the information of radiation field change between 90 min. before the alarm and 30 min. after the alarm and also provide the data to an IBM compatible computer to analyze the accidents and to set a counterplan. It features a wide detection range of radiation field(10 mR/h-100 R/h), radiation field data storage, portability, high precision (${\pm}5%$) due to self-calibration function, and adaption of a powerful alarm system. According to ANSI N42.17A, the most stringent test standards, performance tests were carried out under various conditions of temperature, humidity, vibration, and electromagnetic wave hindrance at Korea Research Institute of Standards & Science (KRISS). As a result, the Radiation Alarm Monitor passed all tests.

  • PDF

A Control Room Dose Assessment for a 1300 MWe PWR Following a Loss of Coolant Accident (냉각재(冷却材) 상실사고시(喪失事故時) 1300 MWe 급(級) PWR원전(原電) 주제어실(主制御室)의 선량평가(線量評價))

  • Chang, Si-Young;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.1
    • /
    • pp.34-45
    • /
    • 1989
  • The habitability of a reactor control room in a French 1300 MWe P'4 type PWR has been evaluated through the exposure dose assessment for the reactor operator following a Loss of Coolant Accident. The main hypotheses adopted in this evaluation are based on the French Standard Safety Analysis Report. A simple computer program, named COREX(Control Room EXposure), was developed to calculate : the time-integrated radioactivities released from the reactor building, the volume factors for radionuclides concerned and the resulting time-integrated external whole body and internal thyroid doses to the reactor operators staying in the control room up to 30 days following the LOCA. The results obtained in this study, on the whole, well agreed with those proposed by the EDF(Electricite de France) except for the case of the whole body exposure, which was attributed to the differences in the volume factors for the radionuclides concerned.

  • PDF

A Study of Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET-CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Kim, Bit-Na;Cho, Suk Won;Lee, Juyoung;Lyu, Kwang Yeul;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to 99mTc emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radio technologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radio technologists. Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8cm$, mean weight: $65.9{\pm}1.4kg$). Radiation was measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150, and 200 cm, respectively. Then, all the procedure was given with a portable radiation shielding on the location of head, chest, and abdomen at the distance of 100, 150, and 200 cm and transmittance was calculated. In 10 cm, head ($105.40{\mu}Sv/h$) was the highest and foot($15.85{\mu}Sv/h$) was the lowest. In 200 cm, head, chest, and abdomen showed similar. On head, the measured dose rates were $9.56{\mu}Sv/h$, $5.23{\mu}Sv/h$, and $3.40{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.24{\mu}Sv/h$, $1.67{\mu}Sv/h$, and $1.27{\mu}Sv/h$ in 100, 150, and 200 cm on head. On chest, the measured dose rates were $8.54{\mu}Sv/h$, $4.90{\mu}Sv/h$, $3.44{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.27{\mu}Sv/h$, $1.34{\mu}Sv/h$, and $1.13{\mu}Sv/h$ in 100, 150, and 200 cm on chest. On abdomen, the measured dose rates were $9.83{\mu}Sv/h$, $5.15{\mu}Sv/h$, and $3.18{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.60{\mu}Sv/h$, $1.75{\mu}Sv/h$, and $1.23{\mu}Sv/h$ in 100, 150, and 200 cm on abdomen. Transmittance was increased as the distance was expanded. As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the technologists.

Development of the Monte Carlo Simulation Radiation Dose Assessment Procedure for NORM added Consumer Adhere·Non-Adhere Product based on ICRP 103 (ICRP 103 권고기반의 밀착형·비밀착형 가공제품 사용으로 인한 몬테칼로 전산모사 피폭선량 평가체계 개발)

  • Go, Ho-Jung;Noh, Siwan;Lee, Jae-Ho;Yeom, Yeon-Soo;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.124-131
    • /
    • 2015
  • Radiation exposure to humans can be caused by the gamma rays emitted from natural radioactive elements(such as uranium, thorium and potassium and any of their decay products) of Naturally Occurring Radioactive Materials(NORM) or Technologically Enhanced Naturally Occurring Radioactive Materials(TENORM) added consumer products. In this study, assume that activity of radioactive elements is $^{238}U$, $^{235}U$, $^{232}Th$ $1Bq{\cdot}g^{-1}$, $^{40}K$ $10Bq{\cdot}g^{-1}$ and the gamma rays emitted from these natural radioactive elements radioactive equilibrium state. In this study, reflected End-User circumstances and evaluated annual exposure dose for products based on ICRP reference voxel phantoms and ICRP Recommendation 103 using the Monte Carlo Method. The consumer products classified according to the adhere to the skin(bracelet, necklace, belt-wrist, belt-ankle, belt-knee, moxa stone) or not(gypsum board, anion wallpaper, anion paint), and Geometric Modeling was reflected in Republic of Korea "Residential Living Trend-distributions and Design Guidelines For Common Types of Household.", was designed the Room model($3m{\times}4m{\times}2.8m$, a closed room, conservatively) and the ICRP reference phantom's 3D segmentation and modeling. The end-user's usage time assume that "Development and Application of Korean Exposure Factors." or conservatively 24 hours; in case of unknown. In this study, the results of the effective dose were 0.00003 ~ 0.47636 mSv per year and were confirmed the meaning of necessary for geometric modeling to ICRP reference phantoms through the equivalent dose rate of belt products.

An Effective Block of Radioactive Gases for the Storage During the Synthesis of Radiopharmaceutical (방사성의약품 합성에서 발생하는 방사성기체의 효율적 차단)

  • Chi, Yong Gi;Kim, Dong Il;Kim, Si Hwal;Won, Moon Hee;Choe, Seong-Uk;Choi, Choon Ki;Seok, Jae Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.126-130
    • /
    • 2012
  • Purpose : Methode an effective block was investigated to deal with volatile radioactive gas, short lived radioactive waste generated as a result of the routinely produced radiopharmaceuticals FDG (2-deoxy-2-[$^{18}F$]fluoro-D-glucose) and compound with $^{11}C$. Materials and Methods : All components of the radiation stack monitoring and data management system for continuous radioactive gas detection in the air extract system purchase from fixed noble gas monitor of Berthold company. TEDLAR gas sampling bags purchase from the Dongbanghitech company. TEDLAR gas sampling bags (volume: 10 L) connected via paraflex or PTFE tubing and Teflon 3 way stopcock. When installing TEDLAR gas sampling bags in Hot cell on the inside and not radioactive gas concentrations were compared. According to whether the Hot cell inside a activated carbon filter installed, compare the difference in concentration of the radioactive gas $^{18}F$. Comparison of radiation emission concentration difference of module a FASTlab and TRACElab. Results : Activated carbon filter are installed in the Hot cell, a measure of the concentration of radioactive gas was 8 $Bq/m^3$. Without activated carbone filter in the hot cell was 300 $Bq/m^3$. Tedlar bag prior to installation of the radioactive gases a measure of the concentration was 3,500 $Bq/m^3$, $^{11}C$ synthesis of the measured concentration was 27,000 $Bq/m^3$. After installed a Tedlar bag and a measure concentration of the radioactive gases was 300 $Bq/m^3$ and $^{11}C$ synthesis was 1,000$Bq/m^3$. Conclusion : $^{11}C$ radioactive gas that was ejected out of the Hot cell, with the use of a Tedlar gas sampling bag stored inside. A compound of 11C is not absorbed onto activated carbon filter. But can block the release out by storing in a Tedlar gas sampling bag. We was able to reduce the radiation exposure of the worker by efficient radiation protection.

  • PDF

The Improvement Plan on Unifying from Law and Regulations Related to Radiation (방사선관계법 개정 시 용어 적용에 관한 개선 방안)

  • Jeong, Dong-Kyong;Lee, Jong-Back;Park, Myeong-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.7-12
    • /
    • 2006
  • Purpose: This is for the purpose to help the bill related to technologists be systematic and unitary by carefully analyzing a legislation, an enforcement ordinance, and enforcement regulations in the connection with the radiological worker and the radiation workers from the law and regulations related to technologists. Materials and Methods: Concerning technologists, a legislation, an enforcement ordinance, and enforcement regulations for a sort of medical technician, regarding the radiological worker, the rules of diagnosis radiation equipment safety management, and concerning the radiation workers, atomic energy law, an enforcement ordinance and enforcement regulations were gathered, compared with one another, and analyzed. Results: Among technologists, in the case of working in the department of diagnosis radiation, the title 'Radiological Worker' is used by the Medical Service Law, and in the case of working in the department of radiation tumors or the one of nucleus medicine, the title 'Radiation Workers' is used by the Atomic Energy Law. Conclusion: Besides the technical term that is used by characteristic tasks, unification of the terms that can be used in common is necessary for sure. And when a legislation, an enforcement ordinance, enforcement regulations, and notification, things like that in the radiation field are amended, certainly they should be done by mutual agreement through negotiation between the organization related to radiation and the governmental organization.

  • PDF

An External Costs Assessment of the Impacts on Human Health from Nuclear Power Plants in Korea (국내원전운전(國內原電運轉)에 따른 보건영향(保健影響)의 외부비용평가(外部費用評價))

  • Kim, Kyoung-Pyo;Kang, Hee-Jung
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.67-76
    • /
    • 2008
  • As the first comprehensive attempt at a national implementation, this study aims at assessing the external costs of major electricity generation technologies in Korea, particularly an evaluation of the impacts on human health resulting from exposures to atmospheric radiological emissions from nuclear power plants, and a monetary quantification of their damages. The methodology used for the assessment of the externalities of the selected fuel cycles has been developed by the International Atomic Energy Agency (IAEA), namely the SimPacts Model Package. The model is internationally recognized as a tool which can be applied to a wide range of fuels, different technologies and locations, for an externalities study. In this study, the relevant emissions are quantified first and then their impacts on human health are evaluated and compared. The study focused on all the nuclear power plants for the last 6 years ($2001{\sim}2006$) in Korea. With respect to nuclear power, the impact analysis only focuses on a power generation, however the front- and back-end nuclear fuel cycles are not included, namely uranium mining, conversion, enrichment, reprocessing, conditioning, etc., because these facilities are not present in Korea. The analysis results show that nuclear power in general, generates low external costs. The highest damage costs from the nuclear power plants among the 4 sites in Korea were estimated to be 3.9 mills/MWh, which is about 1/20th of the result for a similar case study conducted in the U.K., implemented through the ExternE project. This difference is largely due to the number of radionuclides included in the study and the amount of released radioactive emissions based on up-to-date information in Korea. In this study, the sensitivities of the major factors for nuclear power plants were also calculated. The analysis indicates that there was around a ${\pm}3%$ damage costs variation to a ${\pm}15%$ change of the reference population density and a ${\pm}1%$ damage cost variation to a $1{\sim}30$ meters change of the effective release height, respectively. These sensitive calculations show that there is only a minor difference when the reference costs are compared.