• Title/Summary/Keyword: 외부자장

Search Result 107, Processing Time 0.024 seconds

Surface Dose Measurement of Electron Beam within the Magnetic Field Variation (자기장 내에서 전자선의 표면선량 변화 측정)

  • Je, Jae-Yong;Noh, Kyung-Suk;Shin, Oon-Jae;Park, Cheol-Woo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.103-107
    • /
    • 2008
  • Purpose: This paper describes a electron field presence of magnetic field, intensity and shape surface dose variation to clinical application possibility. Materials and Methods: The using 6 MeV electron and $10{\times}10\;cm^2$ field size, 9 hole to shielding block make the by measure the film, when the magnetic field position inside and outside of the X-Omat film and parallel plate ionization chamber using the surface dose measured. Results: Present of 4 cm to the side at angle about 3 degree from beam center, use of ring type magnetic is 0.9% increase the surface dose, lens block located in the magnetic field the surface dose 1.58% increase, half magnetic field's position on the side of them at the field center of the 3.6% increase of the surface dose. Conclusion: Surface dose variation is with magnetic field about the mean electron beam of progress direction change, orbit region patient's is inconvenient without surface dose increase percentage case goodness will be used as a useful way.

  • PDF

남해 동부 연안 지역 지하수의 수리지구화학적 연구: 해수침투에 대한 고찰

  • 신광섭;윤성택;허철호;이상규
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.438-441
    • /
    • 2003
  • 남해 동부 연안 지역 지하수의 해수 침투 영향을 광역적으로 파악하기 위하여, 202개소의 지하수 시료를 채취하고 수리지구화학적 연구를 수행하였다. 전체 시료 중 14.4%가 500 $\mu\textrm{m}$/cm을 초과하는 높은 EC값을 나타내어 해수 영향을 시사해 주었다. 해수 영향 판단의 또 다른 파라메터로 사용되는 CI/HCO$_3$ 몰비는 전체 시료의 23.3%가 1.3 이상의 값을 나타내었다. 한편, 대표적으로 해수침투 영향 및 인위적 오염의 영향을 각각 반영하는 것으로 알려진 Cl과 NO$_3$의 농도에 관한 누적도수분포도를 작성하여 배경수질군과 오염영향군을 구분짓는 배경치(background concentration)를 구한 결과, 각각 Cl = 22.3 mg/1 및 NO$_3$= 23.1 mg/l로 나타났다. 이 두 파라메터의 농도 분포를 기준으로 하여 채취된 지하수 시료를 크게 4개의 그룹으로 나눌 수 있었다. 그 결과, 자연적 또는 인위적 기원의 오염이 배제된 그룹 1은 전체 시료의 31%, 자연적 오염(해수 영향)을 반영하는 그룹 2는 전체의 24%, 인위적 오염의 영향을 반영하는 그룹 3은 전체의 9%, 해수 영향 및 인위적 오염을 동시에 반영하는 그룹4는 전체의 36%로 나타났다. 또한 그룹2와 그룹4는 대부분 Na-Cl유형으로 진화하는 Ca-Cl유형을 나타내었다. 따라서, 여러 지구화학 방법에 의한 해수 영향 판단 결과는 서로 잘 일치하고 있음을 알 수 있다. 결국, 지구화학적 파라메터를 종합적으로 활용함으로써, 연안 지역 해수침투의 효과적인 파악은 물론 예측 및 방지, 복구에 효과적으로 사용될 수 있을 것으로 판단된다.으로 토양에서 유동 가능성이 있는 중금속만을 추출하였다. 분석실험은 토양의 Cd2+ 와 Pb2+를 대상으로 행하여졌으며, 여러 토양에서 추출 분석한 결과를 EDTA분석결과와 비교하였다. 실험결과, 중금속은 매우 신속하게 고분자 자성체와 결합하였고, 그 후 자성체를 외부 자장으로 모은 후 산으로 용해시키고, 결합된 중금속은 Graphite furnace AAS로 분석함으로써 빠르고 효율적으로 분석실험을 수행할 수 있음을 알 수 있었다. 한편, 실험에서 나타난 수치들을 비교 검토한 결과 토양 분석시 sandy soil에서는 자성체를 이용한 분석이 EDTA에 의한 방법보다 더 높은 추출도를 보인 반면, silt 함량이 많은 토양의 경우에서 EDTA분석에서 더 높은 중금속 추출도를 보였다.s 중에서 490nm와 555nm의 복합밴드를 포함하는 OC2 알고리즘(ocean color chlorophyll 2 algorithm)을 사용하는 것이 OC2 series 및 OC4 알고리즘보다 좋은 추정 값을 도출할 수 있을 것으로 기대된다.환경에서는 5일에서 7월에 주로 이 충체의 유충이 발육되고 전파되는 것으로 추측되었다.러 가지 방법들을 적극 적용하여 금후 검토해볼 필요가 있을 것이다.잡은 전혀 삭과가 형성되지 않았다. 이 결과는 종간 교잡종을 자방친으로 하고 그 자방친의 화분친을 사용할 때만 교잡이 이루어지고 있음을 나타내고 있다. 따라서 여교잡을 통한 종간잡종 품종육성 활용방안을 금후 적극 확대 검토해야 할 것이다하였다.함을 보이고 있다.X> , ZnCl$_{3}$$^{-}$같은 이온과 MgCl$^{+}$, MgCl$_{2}$같은 이온종을 형성하기 때문인것 같다. 한편 어

  • PDF

Magnetism of Amorphous Bulk $(Sm_{1-x}Pr_x)Fe_2$ Alloys in a Low Magnetic Field (저자장에서 비정질 후막$(Sm_{1-x}Pr_x)Fe_2$의 자성)

  • Kim, Jai-Young
    • Korean Journal of Materials Research
    • /
    • v.5 no.8
    • /
    • pp.913-920
    • /
    • 1995
  • RFe$_2$(R=rare earth) Laves Phase intermetallic compounds are one of the promising materials for magnetostrictive applications, due to large magnetostriction coefficients in the order of 10$^{-3}$ . However, because RFe$_2$intermetallic compounds have large magnetostriction constants as well as large magnetocrystalline anisotropy constants, a large external magnetic field is necessary to reach saturation magnetostriction. Hence researches on giant magnetostriction have been concentrated on producing materials exhibiting a high value of magnetostriction in a low magentic field. The main research trend of the giant magnetostriction to obtain the large value in the low magnetic filed, fortunately as the signs of magnetocrystalline anisotropy constans in RFe$_2$intermetallic compounds alternate with the rare earth metals, has been to substitute the rare earth metal for others and hence to reduce the magnetocrystalline anisotropy energy. In addition, amorphous RFe$_2$alloys have been researched. In this research, both of the methods which are substitution of the rare earth metal and amorphization in RFe$_2$ intermetallic compounds are simultaneously conducted to obtain the large magnetostriction coefficient in the low external magnetic field. Among them, SmFe$_2$and PrFe$_2$are selected, and amorphized in substrate-free bulk state. Magnetism in amorphous bulk (Sm$_{1-x}$ Pr$_{x}$) Fe$_2$alloys is investigated in the low magnetic field.ld.

  • PDF

A Study on the Magnetic Anisotrpy and Magnetoresistive Characteristics of NiFe/Cu/Co Trilayers (NiFe/Cu/Co 삼층막의 자기이방성과 자기저항 특성에 관한 연구)

  • 김형준;이병일;주승기
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.5
    • /
    • pp.323-328
    • /
    • 1996
  • NiFe($60\;{\AA}$)/Cu($60\;{\AA}$)/Co($30\;{\AA}$) trilayers were formed on the $4^{\circ}$ tilt-cut Si(111) substrate by rf magnetron sputtering method. With a Cu($50\;{\AA}$) underlayer, NiFe($60\;{\AA}$)/Cu($60\;{\AA}$)/Co($30\;{\AA}$) trilayers developed in-plane magnebc anisotropy and in-plane perpendicular alignment of easy axes in two magnetic components of NiFe($60\;{\AA}$)/Cu($60\;{\AA}$)/Co($30\;{\AA}$) trilayers has been found. The easy axis of Co layer consisbng of NiFe($60\;{\AA}$)/Cu($60\;{\AA}$)/Co($30\;{\AA}$) trilayers turned out to be along $4^{\circ}$ tilt Si <112> direcbon and that of NiFe layer along Si <110> direction. [NiFe($60\;{\AA}$)/Cu($60\;{\AA}$)/Co($30\;{\AA}$)]/Cu($50\;{\AA}$)/Si(111, $4^{\circ}$ tiIt-cut) trilayers showed about 2.2 % MR ratio at room temperature and large plateau in MR curves, which are more improved MR characteristics than those in [NiFe($60\;{\AA}$)/Cu($60\;{\AA}$)/Co($30\;{\AA}$)]/Cu($50\;{\AA}$)/glass trilayers with no appreciable magnetic anisotropy.

  • PDF

Simulation of Remote Field Scanner for Defect Evaluation of Water Wall Tube Within the Fluidized Bed Boiler (유동층보일러 수냉벽튜브 결함평가를 위한 원격자장 스캐너 시뮬레이션에 관한 연구)

  • Gil, Doo-Song;Jung, Gye-Jo;Seo, Jung-Seok;Kim, Hak-Joon;Kwon, Chan-Wool
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.2
    • /
    • pp.145-150
    • /
    • 2020
  • Water wall tube is one of the major factors consisting of a fluidized bed boiler and it plays very important role for the generation of electricity within the boiler. But these water wall tubes within the fluidized bed boiler are subject to the ware and corrosion caused by the high temperature gas and the flowing medium. If water leak is occurred, the secondary damage by the water leak will occur. As a result of that, the power generation efficiency decreases noticeably. Therefore, the maintenance of the water wall tube is very important. In this study, we designed a exciter sensor based on simulation and composed a remote field eddy current system for the defect evaluation of the outer water wall tube. Starting from the shape design of exciter, we conducted simulations for various design factors such as the water wall tube size, material, frequency, lift-off and so on. Based on the results, we designed the optimum exciter sensor for the water wall tube test within the fluidized bed boiler.

Effects of Ultrathin Co Insertion Layer on Magnetic Anisotropy and GMR Properties of NiFe/Cu/Co Spin Valve Thin Films (NiFe/Cu 계면에 삽입된 Co 층이 NiFe/Cu/Co 스핀밸브 박막의 거대자기저항 특성과 자기이방성에 미치는 영향)

  • 김형준;조권구;주승기
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.5
    • /
    • pp.251-255
    • /
    • 1999
  • NiFe(60 $\AA$)/Co(0$\AA$$\leq$x$\AA$$\leq$15$\AA$)/Cu(60$\AA$)/Co(30$\AA$) spin valve thin films were prepared on 4$^{\circ}$ tilt-cut Si(111) substrates with a 50 $\AA$ thick Cu underlayer without applying any external magnetic field during the deposition, and the effects of inserted ultrathin Co layer on magnetic anisotropy and GMR properties of the NiFe(60 $\AA$)/Cu(60$\AA$)/Co(30$\AA$) spin valves were investigated. As the ultrathin Co layer was inserted into the NiFe/Cu interface of the spin valves, GMR ratio was increased from about 1.5% to 3.5%, and the easy axis of NiFe(60 $\AA$) layer was rotated by 90$^{\circ}$. Accordingly, it was aligned along the same direction with the easy axis of Co(30 $\AA$)layer. Therefore, squared R-H curves was obtained in the spin valves, which is favorable properties for the digital GMR devices such as MRAM. In order to investigate the change of magnetic anisotropy of NiFe layer of the spin valves in more details,XRD measurement was performed using NiFe(500 $\AA$) and NiFe(500 $\AA$)/Co(10 $\AA$) thin films on the same templates. Strong (220) NiFe peak was observed in both films regardless of the inserted Co layer, so it was thought that the variation of magnetic anisotropy of NiFe layer is from the interface effect, the change of interface from NiFe/Cu to NiFe/Co, rather than the volume effect such as the change of magnetocrystalline effect.

  • PDF

A Basic Study on a Magnetic Fluid Driven Artificial Heart (자성유체에 의해 구동되는 인공심장에 관한 기초연구)

  • Kim, Dong-Wook;MITAMURA, Yoshinoro
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.5
    • /
    • pp.940-947
    • /
    • 2006
  • A variety of actuators fur an implantable artificial heart have been studied. They, all, however, share the disadvantages of a complicated energy conversion mechanism and of the need to use bearings. A ferrofluidic actuator directly drives magnetic fluids by applying a magnetic field to these fluids; it does not require bearings. In this study, the feasibility of a ferrofluidic actuator for an implantable artificial heart was studied. An way of two Poles of ring solenoids was mounted near the acrylic tube $({\phi}\;7.4mm)$. A rubber sack (volume : $2m{\ell}$ was connected to both ends of the acrylic tube. The sack were encased in a rigid chamber that had inlet and outlet ports. The acrylic tube and the rubber sack were filled with water encased in a rigid chamber magnetic fluid and the iron cylinder were immersed in the water. Two experiment method was conducted. 1) distance between stoppers were 72mm and 2) distance between stoppers were 104mm. A stroke volume was stability and $0.96m{\ell}$ was obtained in the experiment 1 and $1.92m{\ell}$ in the experiment 2. The energy efficiency of Experiment method 2 is about five times than Experiment method 2. A magnetic fluid-driven blood pump could be feasible if the magnetic fluid with high magnetization (3 times yester than the current value) is developed.

  • PDF