• Title/Summary/Keyword: 외부연결형

Search Result 161, Processing Time 0.025 seconds

Effects of abutment angulation and type of connection on the fracture strength of zirconia abutments (지대주 각도와 연결방식이 지르코니아 지대주의 파절강도에 미치는 영향)

  • Kim, Ho-Seong;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.9-17
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the fracture strength of straight and angled zirconia abutments for internal hex and external hex implants. Materials and methods: Twenty internal hex implants and 20 external hex implants were prepared. The prefabricated straight zirconia abutments and 17-degree-angled zirconia abutments were connected to those 40 implants. The specimens were classified into 4 groups depending on the connection type and abutment angulation; internal hex implant/straight abutment, group INS; internal hex implant/angled abutment, group INA; external hex implant/straight abutment, group EXS; external hex implant/angled abutment, group EXA. All specimens were loaded at a 30-degree angle with a crosshead speed of 1 mm/min using universal testing machine. The fracture loads were analyzed using 2-way ANOVA and independent t-test (${\alpha}=.05$). Results: The mean fracture load for INS was 955.91 N, 933.65 N for INA, 1267.20 N for EXS, and 1405.93 N for EXA. External hex implant showed a significantly higher fracture load, as compared to internal hex implant (P < .001). No significant differences in fracture loads were observed between the straight and angled abutment in internal hex implants (P = .747) and external hex implants (P = .222). Internal hexes of abutments were fractured horizontally in internal connection implants, while lingual cervical neck portions were fractured in external connection implants. Conclusion: The zirconia abutments with external hex implants showed significantly higher fracture strength than those with internal hex implants. However there was no difference in fracture strength between the straight and 17-degree-angled zirconia abutment connected to both implant systems.

Concept and application of implant connection systems: Part II. Placement and restoration of external connection implant and tissue level implant (임플란트 연결부의 개념과 적용: Part 2. 안착형 외부 및 내부 연결형 임플란트의 식립과 보철)

  • Ko, Kyung-Ho;Kang, Hyeon-Goo;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.222-231
    • /
    • 2020
  • To use the external connection implant (EXT) appropriately, the inter-implant distance should be carefully considered during placement, and the bones raised above the implants should be trimmed during the second surgery. The hex abutment is more useful than the non-hex abutment. EXT is particularly useful when the inter-arch space is limited. The tissue level (TL, internal butt connection) implant has a biomechanical advantage of coronal wall thickness and a biological advantage of an inherent transmucosal smooth surface. During TL implant restoration, an abutment can be selected using the abutment and fixture margins with considerations for the inter-arch space. Since no single type of implant can satisfy all the cases, it is necessary to select the appropriate type, considering the occlusal force and the bone condition.

Effect of Implant Types and Bone Resorption on the Fatigue Life and Fracture Characteristics of Dental Implants (임플란트 형태와 골흡수가 임플란트 피로 수명 및 파절 특성에 미치는 효과에 관한 연구)

  • Won, Ho-Yeon;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.121-143
    • /
    • 2010
  • To investigate the effect of implant types and bone resorption on the fracture characteristics. 4 types of Osstem$^{(R)}$Implant were chosen and classified into external parallel, internal parallel, external taper, internal taper groups. Finite elements analysis was conducted with ANSYS Multi Physics software. Fatigue fracture test was performed by connecting the mold to the dynamic load fatigue testing machine with maximum load of 600N and minimum load of 60N. The entire fatigue test was performed with frequency of 14Hz and fractured specimens were observed with Hitachi S-3000 H scanning electron microscope. The results were as follows: 1. In the fatigue test of 2 mm exposed implants group, Tapered type and external connected type had higher fatigue life. 2. In the fatigue test of 4 mm exposed implants group, Parallel type and external connected types had higher fatigue life. 3. The fracture patterns of all 4 mm exposed implant system appeared transversely near the dead space of the fixture. With a exposing level of 2 mm, all internally connected implant systems were fractured transversely at the platform of fixture facing the abutment. but externally connected ones were fractured at the fillet of abutment body and hexa of fixture or near the dead space of the fixture. 4. Many fatigue striations were observed near the crack initiation and propagation sites. The cleavage with facet or dimple fractures appeared at the final fracture sites. 5. Effective stress of buccal site with compressive stress is higher than that of lingual site with tensile stress, and effective stress acting on the fixture is higher than that of the abutment screw. Also, maximum effective stress acting on the parallel type fixtures is higher. It is careful to use the internal type implant system in posterior area.

The Design Trends of Outdoor Space in Commercial Multi-Complexes in Korea (국내 복합상업시설 외부공간의 특성과 변화 양상)

  • Choi, YoungJoon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.5
    • /
    • pp.89-106
    • /
    • 2020
  • This study examines the functionality and landscape design specifics of the outdoor space of representative commercial multi-complexes in Korea in order to overview the design trends of outdoor landscaping trends. Through surveying the composition of outdoor spaces along with their relation to the surrounding landscape, open spaces, and the neighboring communities, this paper identified the change in trends regarding the characteristics of outdoor landscape planning and acknowledged the enhanced public value of outdoor space. This study asserts that the characteristics of outdoor spaces can best be understood by examining the ways in which the outdoor space relates to adjoining commercial multi-complexes and the surrounding landscape. Focusing on the relationships that outdoor space establishes, commercial multi-complexes can be categorized as follows: in/outdoor separated type, in/outdoor semi-open type, surrounding landscape-projected type, and surrounding landscape-combined type. By studying the landscape design specifics of the outdoor space of representative cases of each type, the following has been concluded: First, the amount of outdoor space has expanded in terms of importance and function while serving to assist in various activities and participatory experiences, and no longer merely serves as a backdrop of commercial facilities. Second, with the strengthened connectivity between in/outdoor spaces, the elements of outdoor surroundings are more actively introduced indoors to improve amenities. Through directly connecting certain indoor program spaces with outdoor spaces, commercial multi-complexes tend to provide richer combined experiences. Third, with the expansion of outdoor space functionality, commercial multi-complexes are increasingly recognized as a quasi-public space, making good example of liminal space. In light of the recent case of development plans linked with public open spaces in suburban settings, commercial landscape design shows the possibility of creating an open space that can function as a center for local culture and green networks in the community.

A study on the large scaling of Dye-Sensitized Solar Cell for commercialization (염료 감응형 태양전지의 상용화를 위한 실용적 대면적화에 대한 연구)

  • Kim, Mi-Jeong;Seo, Hyun-Woong;Hong, Ji-Tae;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1297-1298
    • /
    • 2007
  • 염료 감응형 태양전지(DSSC)의 개발 이후 많은 연구와 실험이 상용화를 위한 대면적화에 중점을 두고 진행되고 있다. 대면적화에 대한 대부분의 연구에서 그리드 전극을 넣고 내부적으로 직, 병렬 구조를 조합해 확장 시키는 방법을 채택하고 있지만, 그리드 전극을 넣음으로써 발생하는 손실, 즉 실링 공정의 어려움으로 발생하는 전자의 손실과 제작 공정상에 있어서의 복잡한 절차 및 그에 따라 소요되는 시간 등을 감안할 때 이는 그리 효과적이지 못하다고 할 수 있다. 면적이 작은 여러 셀을 외부에서 연결시켜 대면적화 시켰을 때 그 효과에 대해서 알아보고, 동일한 면적의 대면적화 된 단일 셀과 비교, 그 결과를 분석해 보았다. 그 결과, 우리는 동일한 면적을 가지고 있는 대면적의 단일 셀보다 여러 셀의 병렬 조합으로 이루어진 것이 더 좋은 결과를 나타냄을 알 수 있었다. 이를 바탕으로 유효면적 $8cm^2$을 가지는 셀을 외부적으로 연결시켜 대면적화 시켰을 때 그 효과에 대해서 알아보고 실험하였다. 하나의 모듈을 만들기 위해 직 병렬의 다양한 조합을 시도하여 직렬 연결이 많이 된 모듈일수록 이를 다시 병렬로 연결했을 때 전류의 손실을 많이 줄일 수 있다는 결론을 얻었다.

  • PDF

Uninterruptable power system using engine generator based on wound rotor induction machine (권선형 유도기 기반 엔진 발전기를 사용한 비상 전원 시스템)

  • Han, Yongsu;Lee, Chung-in;Ha, Jung-Ik
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.186-187
    • /
    • 2016
  • 본 논문에서는 권선형 유도기 기반의 엔진 발전기를 이용한 비상 전원 장치를 제안한다. 기존의 외부 여자동기 전동기를 이용한 엔진 발전기 시스템과 다르게 권선형 유도 전동기를 사용하여, 고정자 권선은 계통에 직접 연결되고, 회전자 단에는 배터리를 전력원으로 하는 인버터를 연결한다. 권선형 유도기가 엔진과 결합되어 엔진 발전기로 연결된 상태에서 계통사고로 계통이 단락 되는 경우 회전자 단 인버터를 이용하여 중요 부하에 전력을 공급하는 동시에 전동기를 구동시켜 엔진 발전기 동작 영역까지 전동기를 구동시키는 제어 방법을 제안한다.

  • PDF

Analysis of implant strain value exerted using different screw tightening protocols in screw-retained 3-unit prostheses (3본 나사 유지형 임플란트 보철물의 고정 방식에 따른 임플란트 고정체 치경부에 발생하는 변형율 비교분석)

  • Kim, Sang-Beom;Lee, Du-Hyeong;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.321-327
    • /
    • 2020
  • Purpose: The purpose of this study was to measure and compare the strain value exerted on the cervical area using different screw tightening protocols in implant-supported, screw-retained 3-unit prostheses. Materials and methods: Strain gauges were attached to four implants: two external and two internal. Thereafter, two study model were designed each type using acrylic resin. CAD-CAM was used to design hex and nonhex abutments for each group (EH, ENH, IH, and INH group) and Screw-cement-retained prostheses were also designed using a nonprecious base metal. Abutment was fixed with 10 Ncm torque, and the prosthesis was cemented. Screws were fixed with 30 Ncm torque using different three protocols. After 5 min, the strain gauge level was measured, and group analysis was performed (α=.05). Results: External group showed significantly lower strain values than internal group and the EH group showed significantly lower strain values than the ENH group (P<.05). There was no difference in strain value based on the types of screw tightening protocols in same group (P>.05). The IH group exhibited significantly higher strain values than the INH group and the IH group showed a significant difference in strain values based on the types of screw tightening protocols used (P<.05). Conclusion: There was no significant effect on the external type in the implant-supported, screw-retained prostheses. However, strain values were high in the internal type, and the types of screw tightening protocol significantly affected these implants.

자궁암 치료 시 고선량률 근접 치료기와 사용될 초음파 온열치료기 개발

  • Lee, Re-Na;Seo, Hyeon-Suk;Lee, Gyeong-Ja;Choe, Jin-Ho
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.81-84
    • /
    • 2004
  • 자궁암 치료시 고선량률 강내 근접치료기와 병행하여 사용할 초음파 온열 치료기가 개발되었다. 온열치료기는 텐덤형, 오보이드 형, 원통형으로 디자인 되었다. 각각의 치료기들에 사용될 초음파원 으로 PZT물질이 사용되었다. 텐덤형의 경우 외부직경이 2mm 이고 길이가 24.5mm 인 PZT5A가 사용되었고 오보이드형은 직경 20mm, 길이 20mm 인 원통형의 PZT 8 물질을 반으로 나누어 사용하였으며 원통형 치료기는 외경 25.4mm, 길이가 15.2 mm 인 원통형 PZT 8물질이 이용되었다. 각각의 트랜스듀서의 초음파 발생효율을 측정하였다. 텐덤형의 경우 3.2MHz 로 작동하였고 평균효율성은 16.7% 이다. 오보이드형의 작동 주파수는 1.5MHz 이며 효율성을 32${\sim}$46% 이다. 마지막으로 원통형의 작동주파수는 1.7MHz 이며 측정?? 효율성의 범위는 55${\sim}$65%이다. 특성분석 결과 온열치료에 사용될 초음파원으로 사용가능함이 입증되었다. 따라서 3개의 텐덤형 드랜스듀서를 연결하여 자궁내막의 길이가 73.5mm까지 치료가능한 텐덤형 온열치료기가 제작되었고 2개의 반원통형 트랜스듀서를 연결하여 치료길이가 40mm 인 오보이드형 치료기가 제작되었다. 마지막으로 4개의 원통형 트랜스듀서를 연결하여 질암등에 사용이 가능하고 61mm 까지 치료가 가능한 원통형 온열 치료기가 제작되었다.

  • PDF

Concept Design of Arc-SAR System Mounted on a Vehicle (차량 탑재형 Arc-SAR 시스템 개념 설계)

  • Cho, Seong-Jun;Lee, Hoon-Yol;Kim, Kwang-Eun
    • Proceedings of the KSRS Conference
    • /
    • 2008.03a
    • /
    • pp.3-6
    • /
    • 2008
  • 본 논문에서는 레일형 GB-SAR의 단점을 극복하고자 차량에 원형레일을 탑재하여 신속한 기동을 확보하고 합성구경의 길이를 늘리며 영상영역을 확장한 Arc-SAR의 설계안을 제시한다. 하드웨어 측면에서 살펴보면, 밴형 차량의 상부에 원형레일을 설치하고 마이크로파 송, 수신 안테나를 탑재한 후 레일 위를 1mm 이내의 정밀도로 이동시키며, 자료를 획득하게 된다. 이때 안테나에 연결된 동축 케이블은 차량 내부의 송, 수신장치에 연결되는데 RF대역에서 완벽히 작동하는 슬립링이 없기 때문에 내부 송, 수신 장치를 턴 테이블위에 장착하여 외부 안테나의 이동과 동일한 각도로 회전하여, 동축 케이블의 꼬임을 방지하게 된다. 송, 수신 장치의 구성은 벡터 네트워크 분석기를 기반으로 마이크로파 앰프, 마이크로파 스위치로 구성되며, 통합 제어 소프트웨어를 통해 외부 안테나의 이동과 함께 제어된다. 한편, Arc-SAR 영상의 구현은 원형레일을 따라 얻어지는 합성구경의 기하학적인 특수성을 감안하여 최초로 시도될 것이다. 이 시스템은 RTK-GPS를 장착하여 지반변형 모니터링 시 차량 이동 오차를 최소화 하고자 하며, 이외에 고정형 산란체를 이용하여 차량 이동 오차를 보정하고자 한다. 또한 AWS (Automatic Weather System)을 장착하여 위상의 대기보정을 동시에 수행할 것이다. 이 시스템은 차량 탑재에 의한 기동성의 확보로 침수나 침하 등 긴급 재난 지역에 즉각적인 대응이 가능하며, 대형 구조물의 주기적인 변형 모니터링 등에 활용성이 클 것이다.

  • PDF

Single External Feeding Wound Machine and Control Method for Washing Machine Drive (세탁기 구동을 위한 단일 외부 전원 공급형 권선형 전동기 및 그 제어 방법)

  • Han, Yongsu;Lee, Kahyun;Ha, Jung-Ik;Jeong, Tae-chul;Lee, Ju
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.173-174
    • /
    • 2013
  • 본 논문에서는 단상 전원과 고정자가 직접 연결되고 회전자에는 독립된 하나의 인버터가 적용되는 전동기 구동 시스템에 대한 분석을 진행한다. 이와 같은 전동기 구동 시스템의 구조는 양방향 운전이 가능하며, 인버터의 직류단 전압을 자유롭게 제어할 수 있다. 또한 입력단에 어떠한 추가적인 장치도 요구하지 않으므로 전동기를 단상 계통에 직접 연결할 수 있어 가전 제품의 적용에 용이하다. 본 논문에서는 이러한 권선형 전동기의 구동 방식을 설명하고, 세탁기 운전을 그 목표로 하여 권선형 전동기의 설계 및 FEM 시뮬레이션을 진행한다. 시뮬레이션은 Maxwell 로 설계된 전동기 FEM 모델을 Simplorer 시뮬레이션을 통해 연동해석을 진행하였다.

  • PDF