Temperature-Dependent Electrochemical Characteristic Analysis for 10kW Li-Polymer Energy Storage System (ESS) (10kW급 에너지 저장장치(ESS)의 전기화학적 온도특성 분석)

  • Kim, J.H.;Choi, H.J.;Song, J.W.;Kim, S.J.;Park, J.P.
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.61-62
    • /
    • 2012
  • 본 논문에서는 10kW급 리튬계열 에너지 저장장치 (ESS;Energy storage system)의 전기화학적 온도특성을 분석하였다. 70개 $LiFePO_4$ 단위 셀의 직렬결합(70S1P)으로 이루어진 ESS의 온도특성 분석을 위해 여름(7월)과 겨울(1월)일때의 ESS Tray/Rack/Cell 전압(표준편차) 및 온도데이터(최대값/최소값)의 통계처리를 실시하였다. 실험결과를 통해, 주변 외기온도에 영향을 최소화한 안정적인 ESS의 최적구축을 위한 가이드 라인을 제시할 수 있다.

  • PDF

Performance characteristics of hot-gas bypass refrigerator with the variation of operation conditions (운전조건 변화에 따른 hot-gas 바이패스 냉동장치의 성능 특성)

  • Baek, Seung-Moon;Son, Chang-Hyo;Heo, Jeong-Ho;Choi, In-Soo;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1021-1026
    • /
    • 2014
  • In this paper, among various systems applying hot-gas bypass control, outdoor temperature, outlet temperature of water cooler, superheating and subcooling degree, which are the factors affecting the performance of the system bypassing hot-gas to evaporator inlet were analyzed. The main results were summarized as following. Frist of all, performance of refrigeration system bypassing hot-gas to evaporator inlet was affected by outdoor temperature, outlet temperature of water cooler, superheating and sub cooling degree. Thus, providing basic planning date of refrigeration system obtained through optimization of variables is expectable. Thus, providing the basic design data of refrigeration system can be offered by performing the optimization of these variables. Also, the feasibility of this refrigeration system proposed in this paper was obtained by analyzing operating characteristics of the system bypassing hot-gas to evaporator inlet.

Capacity Modulation of a Ground Source Multi-Heat Pump in the Part Load Condtions (지열원 멀티열펌프 시스템의 용량가변 특성 연구)

  • Cho, Chanyong;Oh, Myung Suk;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.120-120
    • /
    • 2010
  • 에너지 절약적 차원에서 한 대의 실외기에 다수의 실내기가 접속되는 개별공조형 멀티 열펌프에 관한 연구 및 개발과 보급이 증대되고 있다. 본 연구에서는 복수의 실내기를 갖고 가변속 압축기를 채용한 지열원 물대공기 멀티열펌프시스템을 학교 현장에 설치하여 제조사의 운전 제어 알고리즘에 따라 일일 냉난방 실증 성능 특성을 분석하였다. 2008년 9월 30일의 냉방부하가 낮은 일자에 대하여 시간에 따른 부하 변동에 따라 압축기의 용량가변으로 실내기 냉방용량은 정격용량 대비 17.1%에서 111.3%의 범위에서 변이되었으나, 열펌프 유닛의 일일 최대 COP는 6.2를 나타냈으며, 일일 평균 열펌프 유닛 COP는 4.5로 열펌프 유닛 인증 기준 이상의 성능을 나타냈다. 2008년 11월 10일 대비 2008년 12월 15일에는 시스템 가동 중의 평균 외기온도가 $9.6^{\circ}C$ 감소하였으나, 각 재실공간의 용도별 부분 부하특성으로 11월 10일 보다 난방 부하량이 작게 나타났다. 하지만, 12월 15일에는 부하량이 매우 작아서 11월 10일보다 잦은 압축기 가변에 따른 손실로 일일 평균 COP가 낮게 나타났다. 2009년 1월 12일에는 정격 용량대비 94%의 부하율로 11월 10일과 12월 15일 대비 4배 이상의 부하량으로 압축기 용량 가변율이 작아서 난방용량과 COP 변화율이 작게 나타났다. 2009년 1월 12일에는 지중순환수의 실외열교환기 유입온도가 2008년 12월 15일보다 감소하고, 시스템의 난방용량 증가로 상대적으로 응축기와 증발기 크기가 감소한 효과로 히트펌프 유닛 COP가 감소하였으나, 본 지열원 열펌프 제조사에서 생산하고 있는 본 지열원 시스템과 동일한 압축기 등을 채용한 동일 용량의 공기열원 열펌프의 1월 12일 외기온도 $-10^{\circ}C$에서의 열펌프 유닛 COP 대비 70% 우수한 성능을 나타냈다. 본 지열원 히트펌프의 2008년 11월 10일의 일일 평균 히트펌프 유닛 COP는 외기온도가 낮고 일일 부하량이 크게 나타난 1월 12일의 일일 평균 히트펌프 유닛 COP 대비 37% 높게 나타났으나, 지중순환펌프의 정속운전으로 시스템 요구 지중순환수 유량 증가에 따른 성능 향상보다 소비전력 증가 영향이 커서 1월 12일의 시스템 COP 보다 33.3% 작은 값을 나타냈다. 본 연구의 용량 가변형 압축기를 채용한 지열원 멀티 히트펌프 유닛을 지열원 냉난방 시스템의 히트펌프 유닛으로 사용할 경우 시스템 최적화를 통한 시스템 COP 향상과 연간에너지 절감을 이루기 위해서는 히트펌프의 용량 변화 시에 지중순환펌프의 순환 유량 최적화를 위한 효율적 운전 제어 알고리즘 개발이 요구된다.

  • PDF

Determination of Convection Heat Transfer Coefficient Considering Curing Condition, Ambient Temperature and Boiling Effect (양생조건·외기온도·비등효과를 고려한 콘크리트 외기대류계수의 결정)

  • Choi Myoung-Sung;Kim Yun-Yong;Woo Sang-Kyun;Kim Jin-Keun
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.4 s.88
    • /
    • pp.551-558
    • /
    • 2005
  • The setting and hardening of concrete is accompanied with nonlinear temperature distribution caused by development of hydration heat of cement. Especially at early ages, this nonlinear distribution has a large influence on the crack evolution. As a result, in order to predict the exact temperature history in concrete structures it is required to examine thermal properties of concrete. In this study, the convection heat transfer coefficient which presents thermal transfer between surface of concrete and air, was experimentally investigated with variables such as velocity of wind, curing condition and ambient temperature. At initial stage, the convection heat transfer coefficient is overestimated by the evaporation quantity. So it is essential to modify the thermal equilibrium considered with the boiling effect. From experimental results, the convection heat transfer coefficient was calculated using equations of thermal equilibrium. Finally, the prediction model for equivalent convection heat transfer coefficient including effects of velocity of wind, curing condition, ambient temperature and boiling effects was theoretically proposed. The convection heat transfer coefficient in the proposed model increases with velocity of wind, and its dependance on wind velocity is varied with curing condition. This tendency is due to a combined heat transfer system of conduction through form and convection to air. From comparison with experimental results, the convection heat transfer coefficient by this model was well agreed with those by experimental results.

A Numerical Study for the Performance of Natural Smoke-venting of a Vertical Vent (수직 배연구의 자연배연 성능에 관한 수치해석연구)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.1-10
    • /
    • 2008
  • In this study, the effects of vent location, outside temperature, wind velocity and fire size on the performance of natural venting of the vertical vent designed according to NFPA 204 standard and fire characteristics were numerically investigated using CFAST. In cases of the Vent located on most upper wall, lower outside temperature and lower wind velocity, vents met the performance criteria of venting. The larger fire size becomes, the more mass flow rate through a vent becomes, but the lower interface height of smoke layer becomes, so that vent didn't meet the performance criteria of venting. It should be noted that a natural vertical vent be designed considering maximum outside temperature and maximum wind velocity and developing a design fire accurately in order to meet the performance criteria of venting.

Characteristic Analysis of Hybrid Desiccant Cooling System for District Heating in Residential Environment (지역난방에 연계된 하이브리드 제습냉방시스템의 주거환경에서의 성능 분석)

  • Ahn, Joon;Kim, Jaeyool;Kang, Byung Ha
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.7
    • /
    • pp.571-579
    • /
    • 2014
  • A series of field tests on hybrid desiccant cooling systems were conducted in July-August, 2013. The temperature and humidity of the supply and return air, power, and heat consumption were monitored and transferred in real time through the Internet. The performance parameters of the cooling system, namely, cooling capacity and COP (coefficient of performance), were evaluated from the measured data and their variations under outdoor conditions was analyzed. It was found that with increase in the outdoor temperature, the total energy decreases and cooling capacity increases whereas the latter decreases with increase in the outdoor humidity. The COP was also found to increase with the increase in outdoor temperature.

Analysis of Relations between Ice Accretion Shapes and Ambient Conditions by Employing Self-Organization Maps and Analysis of Variance (자가조직도와 분산분석을 활용한 결빙 형상과 외기 조건의 관계 분석)

  • Son, Chan-Kyu;Oh, Se-Jong;Yee, Kwan-Jung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.8
    • /
    • pp.689-701
    • /
    • 2011
  • The relations between ambient conditions and ice accretion shapes are quantitatively analyzed by employing self-organization maps and analysis of variance. Liquid water contents(LWC), mean volumetric droplet diameter(MVD), ambient temperature and free-stream velocity are chosen as ambient conditions which change ice accretion shapes. The parameters of ice accretion shape are selected as maximum thickness, icing limits, ice heading, and ice accretion area. Qualitative analysis was conducted by employing self-organization maps which show the qualitative relations between ice shapes and ambient conditions. The quantitative results of analysis of variance yield intensity of ambient conditions to the parameters of ice accretion shapes.

A study on the room heating by solar assisted heat pump using the alternatives (대체냉매적용 태양열 열펌프시스템에 의한 난방성능분석(1))

  • 선경호;정현채
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.94-99
    • /
    • 1995
  • 본 연구는 태양열 열펌프시스템에 의한 약 6평 규모의 실내의 난방방법으로서 간접 난방인 온수순환난방과 직접난방인 복사난방의 성능을 분석하였다. 태양열 열펌프의 최대의 열적성능을 나타낼 수 있도록 알루미늄 롤 본드형 태양열 집열기의 면적을 조절하였으며 집열효과를 극대화하기 위하여 온도감응 자동팽창밸브의 용량을 변화시켰다. 본 실험에서 적용된 태양열 열펌프 난방은 서울지방 봄 가을철의 외기온도에서 실내온도가 18~2$0^{\circ}C$로 유지되도록 설계제작되었다. 태양열 열펌프시스템에 적용된 작용유체는 온수순환 난방에는 R-12냉매. 그 대체냉매는 R-134a 및 혼합냉매, 복사난방에는 R-22냉매이었다.

  • PDF

사용후핵연료 중간저장 시설의 사고시 UO$_2$의 산화거동 연구

  • 김건식;유길성;민덕기;김은가;노성기
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05b
    • /
    • pp.727-732
    • /
    • 1995
  • 사용후핵연료 중간저장 시설의 누수사고시 예상되는 핵연료봉의 온도상승을 SFUEL 컴퓨터 코드 분석결과에 따른 실제 $UO_2$의 산화거동을 실험하였다. 외기 온도 38$^{\circ}C$에서 환기회수가 시간당 0, 1, 2회인 조건에서 저장용기 밑바닥 구멍 크기가 2.54, 5.08, 7.62 cm인 경우의 실험결과 환기회수 0회 바닥구멍 크기 2,54 cm 일 때 약 15시간 후 건전성 상실(0.6% 무게증가)이 일어났으며 환기회수 2회 바닥구멍 크기 7.62 cm 일 때는 약 21시간 이후에 건전성 상실이 일어나 가장 느렸다. 바닥구멍 크기가 증가할수록 공기 순환비의 영향을 크게 받으며, 또 외기 온도가 낮을 수록 공기 순환비의 영향을 크게 받았다.

  • PDF

The Effects of Hot Water Supply Temperature on Indoor Thermal Characteristics for Floor Radiant Heating System (바닥복사 난방시스템의 공급온수온도가 실내 열환경에 미치는 영향)

  • Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.4
    • /
    • pp.13-19
    • /
    • 2018
  • The Effects of hot water supply temperature on indoor thermal characteristics for floor radiant heating system in residential apartment were researched by computer simulation. The parametric study on hot water supply temperatures with different outdoor air temperatures was done with regard to energy performance and control characteristics, respectively. As a result, the maximum overshoot of indoor air temperature and energy consumption were reduced by adjusting the hot water supply temperatures with outdoor air temperatures.