• Title/Summary/Keyword: 온수처리

Search Result 63, Processing Time 0.035 seconds

Development of Temperature Control Technology of Root Zone using Multi-line Heating Methods in the Strawberry Hydroponics (다선식 가온방식을 이용한 딸기 수경재배의 배지 온도조절 기술 개발)

  • Kim, Ki-Dong;Ha, Yu-Shin;Lee, Ki-Myung;Park, Dae-Heum;Kwon, Soon-Hong;Choi, Won-Sik;Chung, Sung-Won
    • Journal of Bio-Environment Control
    • /
    • v.19 no.4
    • /
    • pp.189-194
    • /
    • 2010
  • A multi line electric tube consisted of XL pipes contained with 2~4 hot wires and water in it. The specification of one meter length multi-line electric tube was investigated and the proper number in the multi-line electric tube was determined. A multi line electric tube with three hot wires were found to be the most efficient for the media heating control system. Temperature rise of medium in the rice hulls media was faster than that in the perlite media, showed better insulation effect of rice hulls media. Temperature rise of medium with mulching on the top of the bed was faster than without mulching, resulted in the beneficial effect of temperature rise with mulching. The regression model for the rice hulls media with mulching air temperature of $5^{\circ}C$ were a = -0.1458 and b = -0.1088. Using the model, the temperature rise of medium during low temperature season can be predicted for the various media according to the different depths.

Stabilization Performance Evaluation of Filter(pH) Using Ionic Water Generator (이온수기 필터(pH)의 안정화 성능평가)

  • Nam, Sangyep;Kwon, Yunjung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.3
    • /
    • pp.199-205
    • /
    • 2015
  • This study is about ionic water generator filter Recently, a lot of people feel deep interest in health and drinking water. And there are various types of water. Ionic water generator is a system with special function, and can be classified as a medical device and should be manufactured after approval from the Food and Drug Administration. Basically ionized water is different from the packaged and stored water. When the tap water or ground water passes through the various filters of ionic water generator, it turns to the purified water of pH7 ~ 7.5 and we can electrolyze that water into anion and cation by diaphragm. And in negative electrode side, we can get alkaline water with calcium ($Ca^+$), potassium ($K^+$), magnesium ($Mg^+$), sodium ($Na^+$) for body. In general, we can change pH value from 5 to 9 of ionizer by controlling the level of electrolysis voltage in the ionizer. In general, 1stage (pH8), 2stage (pH8.5), 3stage (pH9), 4stage (pH9.5) are used as the alkaline ionized water, -1Stage (pH6.0), -2 stage (pH5.0) are used as the acidic water. But in early stage, the water that passed through filter was weakly alkaline water and that was problem. Therefore, when filter condition is stable, the pH and ORP value of water is different with the early one. the initial setting pH value of the ionizer was confirmed that changes significantly. In order to resolve this problem we need to wash filter for some period time and neutralize by acidification treatment of the filter.

Studies on the Utilization of Persimmons -(Part 1) Effect of Carton Dioxide Treatment on the Removal of Astringency- (감의 이용(利用)에 관(關)한 연구(硏究) -제1보(第一報) 탄산(炭酸)가스처리(處理)가 탈삽(脫澁)에 미치는 영향(影響)-)

  • Seu, Ohn-Soo;Sohn, Tae-Hwa
    • Applied Biological Chemistry
    • /
    • v.19 no.2
    • /
    • pp.93-98
    • /
    • 1976
  • The experiment was made to investigate concentrations of $CO_2\;and\;O_2$ in the removal of astringency of persimmon fruits and to study the changes of total, reducing sugar and hardness during the removal of astringency. 1. During the removal of astringency of persimmon fruits, channel of tannin content showed the rapid decrease in high concentration of $CO_2$ and the gradual decrease in low concentration of $CO_2$. 2. Concentration of oxygen did not show effect on the removal of astringency at high concentration of $CO_2$ but at low concentration of $CO_2$ in Chungdo-Bansi. 3. Optimal concentration of the removal of astringency was $60{\sim}70%,\;CO_2$ and $6{\sim}8%\;O_2$ in Chungdo-Bansi and Sagoksi 4. In changes of sugar content total sugar was decreased and reducing sugar was increased.

  • PDF

The Effect of Safety Culture on the Safety Consciousness and Safety Behavior of Manufacturing Workers -Focusing on the Mediation Effect of Safety Consciousness- (안전문화가 제조업 종사자의 안전의식과 안전행동에 미치는 영향 -안전의식의 매개효과를 중심으로-)

  • Kim, Ji-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.12
    • /
    • pp.151-163
    • /
    • 2019
  • The purpose of this study was to investigate the effects of safety culture on the safety consciousness and safety behaviors of manufacturing workers, and to suggest ways for manufacturing workers to understand the safety culture and improve safety consciousness and safety behavior. To achieve this research objective, out of 176 industrial complexes in Seoul and Gyeonggi Province registered with the Korea Industrial Complex Corporation, workers at 50 industrial complexes, including the Korea Export-Industrial Complex and Seoul's Onsuji, were subject to research. The implementation of this survey distributed 300 questionnaires through the mid-level managers of manufacturers and environment safety and health managers over a period of one month from August 1st to 31st, 2019, finally statisticalizing the data in 282 parts excluding 18 questionnaires deemed to have been unresponsive. First, the safety culture (safety climate, safety procedures) has a positive effect on the safety consciousness (recognition of importance, interest and participation inducement) of the manufacturing workers. Second, the safety culture (safety climate, safety procedures) has a positive effect on the safety behavior (safety planning, safety check) of manufacturing workers. Third, safety consciousness (recognition of importance, interest and inducement of participation) has a positive influence on the safety behavior (safety planning, safety check) of manufacturing workers. Fourth, the safety consciousness (recognition of importance, interest and inducement of participation) appears to have a partial mediating effect in relation to safety culture (safety climate, safety procedure) and safety behavior (safety planning, safety check) of manufacturing workers. The implication of this study is that although the industrial accidents have occurred in the manufacturing industry in recent years, the studies on the workers in the manufacturing industry are insufficient. However, this study is meaningful that it has suggested ways for manufacturing workers to understand the safety culture and improve the safety consciousness and safety behavior by analyzing the effects of safety culture on safety consciousness and safety behavior of manufacturing workers.

Acaricidal Efficacy of Herbal Extracts against Tetranychus urticae (Acarina: Tetranychidae) (점박이응애, Tetranychus urticae (Acarina: Tetranychidae)에 대한 약용식물 추출물의 살비 효과)

  • Lee, Jung-Su;Ham, Eun-hae;Choo, Ho-Yul;Lee, Suk-Jun;Lee, Dong-Woon
    • Journal of agriculture & life science
    • /
    • v.45 no.6
    • /
    • pp.151-162
    • /
    • 2011
  • Methanol and hexane extracts from 35 species in 27 families of herbal plants were evaluated for their acaricidal activities against two-spotted spider mite, Tetranychus urticae by leaf-dipping and spraying methods in laboratory, pot and field, respectively. Acaricidal activities were different depending on herbal plants. When T. urticae was released on leaves of Phaseolus vulgaris var. humilis that were dipped in the 1,000 ppm hexane extracts from fruits of Torreya nucifer and Daphan genkwa, seeds of Xanthium strumarium and Pharbitis nil at one minute they experienced 56.8, 47.8, 47.7, and 47.7% mortalities, respectively. Dipping time influenced acaricidal activity, that is, one minute dipping was more effective than 30 second dipping of Phaseolus vulgaris var. humilis leaves. However, extracts of X. strumarium and P. nil seeds had comparatively high activities. Concentration of hexane extract of X. strumarium and P. nil seeds revealing LC50 were 1,824 and 1,899 ppm, respectively. Extracts of both plants from hot and cold water were not effective representing <20% mortality at 1,000 ppm. However, hexane extracts of X. strumarium and P. nil seeds were effective against T. urticae on P. vulgaris var. humilis representing 76.3 and 71.3% mortalities in pot, respectively. Control effects of hexane extract of P. nil seed were 50.8 and 35.1% at 2,000 and 1,000 ppm against T. urticae on Chrysanthemum morifolium in greenhouse, respectively.

A Study on the Shape and Movement in Dissolved Air Flotation for the Algae Removal (수중조류제거(水中藻類除去)를 위한 가압부상(加壓浮上)에 있어서 기포(氣泡)의 양태(模態)에 관한 연구(研究))

  • Kim, Hwan Gi;Jeong, Tae Seop
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.4
    • /
    • pp.79-93
    • /
    • 1984
  • The dissolved air flotation(DAF) has been shown to be efficient process for the removal of algae ftom water. The efficiency of DAF can be affected by the volume ratio of pressurized liquid to sample, the pressure pressurized liquid, the contact time, the appropriate coagulant and its amount, the water temperature, the turbulence of reactor, the bubble size and rising velocity etc. The purpose of this paper is to compare the practical bubble rising velocity with the theoretical one, to investigate the adhesion phenomenon of bubbles and floc, and the influence of bubble size and velocity upon the process. The results through theoretical review and experimental investigation are as follows: Ives' equation is more suitable than Stokes' equation in computation of the bubble rising velocity. The collection of bubble and algae floc is convective collection type and resulted from absorption than adhesion or collision. The treatment efficiency is excellent when the bubble sizes are smaller than $l00{\mu}m$, and the turbulence of reactor is small. In the optimum condition of continuous type DAF the volume ratio of pressurized liquid to sample is 15%, the contact time in reactor is 15 minutes, the pressure of pressurized liquid is $4kg/cm^2$ and the distance from jet needle to inlet is 30cm.

  • PDF

Application Effect of Heating Energy Saving Package on Venlo Type Glasshouse of Paprika Cultivation (파프리카 재배 벤로형 유리온실에서 난방에너지 절감 패키지 기술 적용효과)

  • Kwon, Jin Kyung;Jeon, Jong Gil;Kim, Seung Hee;Kim, Hyung Gweon
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.225-231
    • /
    • 2016
  • Glasshouse heating package technologies to improve energy usage efficiency in winter were developed. Heating package was composed of the ground water source heat pump with heating capacity of 105kW, the aluminum multi-layer thermal curtain with six layers of different materials and the root zone local heater with XL pipes of ${\phi}20mm$. Venlo type glasshouse($461m^2$) with the heating package was compared with the same type and area control glasshouse with the light oil boiler, the usual non-woven fabric thermal curtain with respect to the glasshouse inside temperature, relative humidity, crop growth, and heating energy consumption. The results of test in paprika cultivation glasshouses showed that the air temperature inside glasshouse with aluminum multi-layer thermal curtain was maintained $2.2^{\circ}C$ higher than that of control glasshouse in un-heating night time and the temperature in bed with root zone local heating was $4.7^{\circ}C$ higher than that in bed without local heating. Average heating coefficient of performance(COP) of the ground water source heat pump used in paprika cultivation was 3.7 and the glasshouse inside temperature was maintained at $21^{\circ}C$ of heating set up temperature. The heating energy consumptions per 10a were measured at 14,071L of light oil and 364kWh of electric power for the control glasshouse and 35,082kWh for the glasshouse applied heating package. As results, the heating cost of the glasshouse applied heating package was 87 percent lower than that of control glasshouse. The growths of paprika in glasshouses of control and applied heating package did not show any significant difference.

Acceleration of Mycelial growth of Lentinus edodes in Coniferous Sawdust (침엽수 톱밥에서 표고 균사생장 촉진에 관한 연구)

  • Park, Kyung-Mok;Kim, Dong-Chan;Lee, Jong-Yoon;Yang, Jae-Kyung;You, Chang-Hyun;Chung, Won-Il
    • The Korean Journal of Mycology
    • /
    • v.22 no.3
    • /
    • pp.222-228
    • /
    • 1994
  • In Lentinus edodes(oak mushroom) cultivation, commonly are logs and sawdusts of oak and some other broadleaved tree species used. Recently oak trees have been substantially diminished due to extensive logging. Thus, to develop comparable synthetic formula using other tree species for the cultivation of Lentinus edodes, we investigated the effect of various nutrients and pretreatment on L. edodes mycelial growth in coniferous sawdusts(i.e., Pine and Larch). We found that 1.5 hr pretreatment of sawdust with hot water and adding 10% rice bran, 3% charcoal, 0.02% $NH_4CI$ and 0.5-1% lignosulfornic acid were effective for the growth of L. edodes in pine sawdust media. In larch sawdust pretreatment with acetone for one hr and adding 20% rice bran, 3% charcoal and 0.02% $NH_4CI$ increased L. edodes mycelial growth. We also analyzed the components of oak and coniferous sawdusts and found oak has higher content of xylose and lower content of lignin, arabinose and mannose than conifers. Rice bran, compared with BITEL(HOKKEN Co.) known for better commercial substitute for rice bran, has lower content of xylose and galactose, but the similar C/N ratio.

  • PDF

Analysis of Actual State of Facilities for Pleurotus eryngii Cultivation - Based on Western Gyeongnam Area - (큰느타리버섯 재배사의 실태분석 - 서부경남지역을 중심으로 -)

  • Yoon Yong Cheol;Suh Won Myung;Yu Chan
    • Journal of Bio-Environment Control
    • /
    • v.13 no.4
    • /
    • pp.217-225
    • /
    • 2004
  • This study was performed to provide the basic knowledge about the mushroom cultivation facilities. Classified current status of cultivation facilities in Gyeongnam province was investigated by questionnaire. The structure of Pleurotus eryngii cultivation facilities can be classified into the simple and permanent frame type. The simple frame structures were mostly single-span type, on the other hand, the permanent frame structures were more multi-span than simple structures. And the scale of cultivation facilities was very different regardless of structural type. But as a whole, the length, width and ridge height were prevailing approximately 20.0 m, $6.6\~7.0m$ and $4.6\~5.0m$ range, respectively. The floor area was about $132\~160\;m^2$, and floor was built with concrete to protect mushrooms from various harmful infection. The roof slope of the simple and permanent type showed about $41.5^{\circ}\;and\;18.6\~28.6^{\circ}$, respectively. The width and layer number of growing bed for mushroom cultivation were around $1.2\~1.6m$, 4 layers in common, respectively. Most of year round cultivation facilities were equipped with cooler, heater, humidifier, and ventilating fan. Hot water boiler was the most commonly used heating system, the next was electric heater and then steam boiler. The industrial air conditioner has been widely used for cooling. And humidity was controlled mostly by ultra-wave or centrifuging humidifier. But some farmers has been using nozzle system for auxiliary purpose. More then $90\%$ of the mushroom house had the independent environment control system. The inside temperature was usually controlled by sensor, but humidity and $CO_2$ concentration was controlled by timer for each growing stage. The capacity of medium bottle was generally 850 cc and 1100cc, some farms used 800 cc, 950 co and 1,250 cc. Most of mushroom producted has been usually shipped to both circulating company and joint market.

The Permeability of Capsule Type Fertilizer and Herbicide with Chitoasn and Alginic Acid (Chitosan과 Alginic Acid를 이용한 캡슐형 비료 및 제초제의 투과특성)

  • LEE Keun-Tai;KIM Sang-Moo;PARK Seong-Min;SON Byung-Yil;KIM Hyoung Seub;LEE Sang-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.2
    • /
    • pp.313-318
    • /
    • 1997
  • Effects of the concentration of NaCl, the concentration and the molecular weight of chitosan on the permeability of capsule type fertilizer and herbicide were investigated. The encapsulating process was based on the electrostatic interaction between chitosan (a polycationic polymer) and sodium alginate (an anionic polysaccharide). Sodium alginate solution $(1\%)$ was dropped into chitosan solution $(1\%)$ in which various amounts of NaCl was added. The capsule strength was increased with the addition of NaCl and the maximum value of capsule strength was observed at 0.3M NaCl. Capsule type fertilizer and herbicide were immersed in deionized water to determine its permeability, and it was affected by the concentration of NaCl and chitosan, and the molecular weight of chitosan. As the concentration of NaCl in chitosan solution increased, permeability of the capsule increased and marked the maximum value of $ 88\%$(fertilizer), $87\%$ (herbicide) at 0.75M NaCl. As concentration of chitosan solution increased, permeability tended to decreased; it showed the maximum value of $90\%$ (fertilizer) and $90.3\%$ (herbicide) at $0.25\%$ chitosan and the minimum value of $83\%$ (fertilizer) and $82\%$ (herbicide) at $1\%$ chitosan. Permeability of fertilizer and herbicide also decreased, as the molecular weight of chitosan (material of capsule) was decreased; it was showed $86\%$ (fertilizer) and $83\%$ (herbicide) at M.W 330,000 (sonication time 0min) and $52\%$ (fertilizer) and $51\%$ (herbicide) at M.W 119,000 (sonication time 180 min). The chitosan-alginic acid capsule was manufactured (defined as prepared capsule), dried for 6 hrs and immersed in deionized water (defined as restored capsule) to examine restoration of capsule. Restoration of capsule was good, and capsule strength was slightly decreased form $20g/cm^2$ (prepared capsule) to $17g/cm^2$ (restored capsule)

  • PDF