• Title/Summary/Keyword: 온도차 해석

Search Result 403, Processing Time 0.031 seconds

Study of Reduction of Mismatch Loss of a Thermoelectric Generator (열전발전 시스템의 부정합손실 저감방안 연구)

  • Choi, Taeho;Kim, Tae Young
    • Journal of Convergence for Information Technology
    • /
    • v.12 no.3
    • /
    • pp.294-301
    • /
    • 2022
  • In this study, a multi-layer cascade (MLC) electrical array configuration method for thermoelectric generator consisting of plural number of thermoelectric modules (TEMs) was proposed to reduce mismatch loss caused by temperature maldistribution on the surfaces of the TEMs. To validate the effect of MLC on the mismatch loss reduction, a numerical model capable of reflecting multi-physics phenomena occuring in the TEMs was developed. MLC can be employed by placing a group of TEMs experiencing relatively low temperature differences in an electric layer with more electrical branches while locating a group of TEMs experiencing relatively high temperature differences in an electric layer with less electrical branches. The TEMs were classified using the temperature distribution obtained by the numerical model. A MLC with an optimal electrical branch ratio showed a 96.5% of electric power generation compared to an ideal case.

A Numerical Study of the 3-D Flow in the Primary Calcinator of Porcelain (도자기 1차 소성로의 3차원 유동장 수치해석에 관한 연구)

  • 김성수;홍성선;박지영;오창섭
    • Journal of Energy Engineering
    • /
    • v.5 no.1
    • /
    • pp.50-55
    • /
    • 1996
  • A numerical simulation on a primary calcinator of porcelain was performed with using Fluent to calculate the heat efficiency by studying velocity vector and temperature profile according to variables such as the location of outlet and porcelain. Control-Volume based Finite Difference Method and Up-wind scheme are used for discretization of differential equation. SIMPLEC Algorithm and standard k-$\varepsilon$ turbulent model are selected to resolve the pressure-velocity coupling and the turbulent. The result of simulation showed that the whole velocity vector field in a calcinator was varied greatly according to the location of outlet. But the whole temperature profile at each zone was still high regardless of the location of outlet because of the radiation. But the temperature of a case with a outlet at sidepart of preheating or cooling zone was little high compared to the case with a outlet on the top of preheating zone. The velocity vector field and temperature profile in a calcinator were almost not affected by the location of porcelain, but the temperature inside a porcelain was much affected according to the place where it was located. The heat efficiency in a calcinator was 44.6% and the gas temperature in the outlet was about 1000 K.

  • PDF

Heat Transfer Analysis of Medium-Size Crankshaft during Induction Heating (유도가열시 중형 크랭크샤프트의 열전달 해석)

  • Park, Sang-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4156-4162
    • /
    • 2013
  • This study was peformed to determine optimum induction heating conditions for a round bar of crankshaft. Four induction heating conditions were proposed and evaluated, employing numerical method, based on electromagnetic and sequential heat transfer analyses, resulting in optimum induction heating conditions which are finally proposed based on peak temperatures at heating zone and minimum temperature gradient through thickness of a round bar after 1 hour induction heating.

Double-Diffusive Convection in Molten Pb-Sn Alloy (용융상태인 납-주석 합금의 이중확산유동)

  • ;Bergman, T. L.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.19 no.2
    • /
    • pp.27-35
    • /
    • 1995
  • 액체 상태인 Pb-Sn 합금에 의한 이중확산유동에 대해 체비세프 콜로케이션 기법을 이용하여 수치해석하였다. 온도차에 의한 부력과 농도차에 의한 부력이 작을때에는 유동형태가 서서히 준정상상태에 이르러 아무런 진동현상을 볼 수 없다. 부력이 증가함에 따라 유동은 수직 농도 경계층을 파괴하여 플륨(Plume)형태의 유동을 생성시키고, 이는 시스템 내부로 성장한 후 소멸된다. 이러한 현상이 반복되면서 높은 주파수의 진동현상을 관찰할 수 있다.

  • PDF

A Numerical Study on the Performance and Transfer Characteristics of Phosphoric Acid Fuel Cell (인산형 연료전지의 성능 및 전달현상에 관한 연구)

  • 전동협;채재우
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1994.11a
    • /
    • pp.9-13
    • /
    • 1994
  • 인산형 연료전지내 열 및 물질전달 특성에 대하여 FDM과 시행착오법에 의하여 3차원 해석이 이루어졌다. Z병행류와 Z대향류를 대상으로 냉각공기 유입방향을 바꿔가며 전류밀도가 평균온도, 전압, 온도분포차, 전류밀도분포차에 미치는 영향에 대하여 고찰하였다. 본 연구의 결과로 Stack에서의 최적조건을 도출하여 연료전지의 성능향상에 도움이 되리라 기대된다.

  • PDF

Study of Thermoelectric Generator with Various Thermal Conditions for Exhaust Gas from Internal Combustion Engine using Numerical Analysis (수치해석을 통한 엔진 배기가스의 조건 변화에 따른 열전소자 발전 특성에 관한 연구)

  • In, Byung Deok;Lee, Ki Hyung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.3
    • /
    • pp.243-248
    • /
    • 2013
  • Internal combustion engines typically expel 30%-40% of the energy supplied by fuel to the environment through their exhaust system. Therefore, further significant improvements in the thermal efficiency of IC engines are possible by recovering the waste heat from the engine exhaust gas. With this fact in mind, a numerical simulation was carried out to investigate the potential of using thermoelectric generation with an internal combustion engine for waste heat recovery. Physical parameters such as the exhaust temperature and mass flow rate were evaluated in the exhaust system, and the optimum location for inserting a thermoelectric generator (TEG) into the system was determined. The TEG will be located in the exhaust system and will use the energy flow between the warmer exhaust gas and the external environment. The optimum position of the temperature distribution and the TEG performance were predicted through numerical analysis. The experimental results obtained showed that the power output significantly increases with the temperature difference between the cold and hot sides of the TEG.

Thermal analysis of concrete dam considering placing interval (타설 간격을 고려한 콘크리트 댐의 수화열 해석특성)

  • Chu, In-Yeop;Jang, Bong-Seok;Kim, Jin-Keun;Park, Byung-Kook
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.385-386
    • /
    • 2009
  • The temperature crack of concrete structure is caused by the phenomenon which the concrete volume is restricted in the inside or outside part due th the temperature variations induced by the hydration heat of cement. And mass concrete structures are weak in temperature crack. This study performed the hydration heat analysis of Seongdeok dam to analyze the hydration heat according to different interval of placement.

  • PDF

Predictions of Heat and Mass Transfer Rates to a Spray Droplet Experiencing Condensation (응축을 수반하는 분무수적으로의 열 및 질량전달률 예측)

  • 이상균;조종철;신원기;조진호;서정일
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.5
    • /
    • pp.1763-1773
    • /
    • 1991
  • 본 연구에서는 포화수증기와 공기의 혼합기내에서 분무수적으로의 열 및 질량 전달률을 계산하기 위하여 수적의 부분혼합모형과 비혼합모형에 대하여 수적내 과도온 도분포의 해석해를 적용성이 보장되면서도 계산상의 어려움이 수반되지 않는 형태로 구하기 위하여 수적내부의 열전도해석에 있어서 적분법을 적용하였다. 적분법으로 얻어지는 과도온도분포의 해는 유한차의 다항식으로 표시되어 비혼합모형인 경우 각시 간 구간의 경계에서의 온도분포가 연속성을 유지하면서 물성치들의 온도에 대한 종속 성이 쉽게 고려되고 계산도 용이한 형태이다. 본 보에서 제시하는 해석결과의 적용 성을 조사하기 위하여 완전혼합모형을 포함하는 세가지 수적모형들에 대한 계산결과들 로부터 얻어진 시간변화에 따른 수적의 무차원 체적평균온도변동을 유효한 실험결과들 과 비교, 검토하였으며, 부분혼합모형에 대하여 혼합기의 압력, 수적의 초기온도, 혼 합기 속에 포함되어 있는 수증기의 체적분율, 수적의 초기크기, 수적의 초기속도 및 분사각도가 주위혼합기로부터 수적으로 전달되는 열 및 질량전달에 미치는 영향을 조] 사하고 도출된 대표적인 검토 결과를 제시하였다.

정온도형 열선유속계의 오차해석과 그 응용

  • 고상근
    • Journal of the KSME
    • /
    • v.31 no.6
    • /
    • pp.512-518
    • /
    • 1991
  • TSI IFA 100 Thermal anemometer와 같이 자동화된 유속계라 할지라도, 사용자가 조정해야 하는 과열비, 인덕턴스 등과 같은 인자가 있다. 이와 같은 조정의 문제 외에도 오차를 고려해야 하는 많은 요소가 있다. 이들 중 주위 유체의 온도 변화에 대한 영향 등에 깊은 이해를 가지고 있어야 정밀계측을 가능하게 할 것이다. 그 예로서 자동차에서 사용되는 정온도형 열선유속계 형의 공기유량계는 주위온도 보상을 위한 회로가 내장되어 동절기와 하절기 사이의 온도차를 보상하고 있다.

  • PDF

Analysis of 1MW Closed OTEC Cycle Using Thermal Effluent and Waste Heat (발전소 온배수를 이용한 1MW급 폐쇄형 해양온도차발전 성능해석)

  • Kim, Hyeon-Ju;Lee, Ho-Saeng;Jung, Dong-Ho;Moon, Deok-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.4
    • /
    • pp.470-476
    • /
    • 2010
  • The thermodynamic performance of closed ocean thermal energy conversion (OTEC) cycle with 1 MW gross power was evaluated to obtain the basic data for the optimal design of OTEC. The basic thermodynamic model for OTEC is Rankine cycle and the thermal effluent from power plant was used for the heat source of evaporator. The cycle performance such as efficiency, heat exchanger capacity, etc. was analyzed on the temperature variation of thermal effluent. The saturated pressure of evaporator increased with respect to the increase of thermal effluent temperature, so the cycle efficiency increased and necessary capacity of evaporator and condenser decreased under 1 MW gross power. As the thermal effluent temperature increases about $15^{\circ}C$, the cycle efficiency increased approximately 44%. So, it was revealed that thermal effluent from power plant is important heat source for OTEC plant. Also, if there is an available waste heat, it can be transferred heat to the working fluid form the evaporator through heat exchanger and cycle efficiency will be increased.