• Title/Summary/Keyword: 오피스 건물

Search Result 46, Processing Time 0.024 seconds

A Study on Design Application of Eco-Friendly Integrated Design Process (친환경 통합 디자인 프로세스의 디자인 적용에 관한 연구 -오피스 건물을 중심으로-)

  • Kim, Min Gyu;Kang, Hee Seon
    • KIEAE Journal
    • /
    • v.13 no.4
    • /
    • pp.87-94
    • /
    • 2013
  • This Study, as a Eco-Friendly Design Process of Office for sustainable design, aims to develop a sustainable design process by letting the designers easily approach the concept of Eco-Friendly Design Process and applying this to Eco-Friendly Design Process when the designers perform design. Through a review on simulation, a research was made on the seriousness of environmental problems and control that was caused by design, Environmentally friendly design, sustainability, and sustainable design's background and definition were studied. In order to develop a Eco-Friendly Design Process, an existing review from Building Energy Simulation that proposed about energy environmentally friendly design element and sustainable design element's semantic similarities were restructured as sustainable design element comparative analysis. Restructured sustainable design elements and the relationship between sustainable design elements and the relationship of each product developmental process levels were analyzed. Finally, through clustering, sustainable design guideline were developed. This Eco-Friendly Design Process is expected to be applied to as one of the methods in solving the global environmental issues in design practice.

An Emergency-Alert Delivery Approach Based on Cell Broadcast for Smart-City IoT Devices (스마트 시티 용 IoT 단말기를 위한 셀 방송 기반의 경보 전송기법)

  • Chang, Sekchin
    • Journal of Broadcast Engineering
    • /
    • v.27 no.5
    • /
    • pp.762-772
    • /
    • 2022
  • Current disaster alert broadcasting based on mobile communication systems targets personal mobile terminals such as smartphones. However, smart cities require IoT-based services such as smart homes and offices. Therefore, when severe disasters such as earthquakes occur, smart cities must quickly perform appropriate control and respond to buildings and factories. For this, a disaster warning broadcasting technique for IoT terminals for smart cities is required. In this paper, we propose a disaster alert transmission method based on 4G/5G mobile communication for IoT terminals for smart cities. The proposed method effectively utilizes the image display method for CBS, a cell-based broadcasting service, and shows the superiority of the proposed approach through simulation.

Scheduling Technique for Remodeling Project of Inhabited Condition (재실 리모델링 특성을 반영한 공정계획 기법)

  • Paik, Hwa-Sook;Nam, Wook-Jin;Kim, Sung-Han;Kim, Hyung-Jin;Choi, Jong-Soo;Kim, Kyung-Hwan
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.2
    • /
    • pp.141-149
    • /
    • 2013
  • This paper presents a scheduling technique that reflects various constraints in remodeling project of inhabited condition. The remodeling project of inhabited condition is required more detailed planning and control due to claims by noise, vibration, dust, smells, limited lift capacity, and limited temporary stock area. Because of the constraints, complexity in scheduling is increased and earlier completion is required to reduce the possibility of safety and environment accidents. Especially, in case of inhabited condition, the scheduling should be linked day-time/night-time/weekend work. This paper proposes a structured scheduling technique to incorporate those constraints in remodeling of inhabited condition. This scheduling technique considers not only remodeling process but also dismantling, newly-construction, and residents movement. Process expression method using MS-Project also presented to keep connectivity with existing scheduling system.

Construction of Aluminum Curtain Wall with 3D Elevation for TRUTEC Building (트루텍 빌딩의 3차원 입체 커튼월 시공)

  • Park, Choel;Hong, Doo-Pyo
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.119-122
    • /
    • 2007
  • TRUTEC building, which is located at DMC B block is zone, is just one the office building in Soeul. TRUTEC building is designed by Barkow Leibinger Architeken in Germany, has 5 stories under and 12 stories above and has been finished with the unique three dimensional curtain wall unit. Big trial to make unique elevation succeeded as getting rid of the typical plain curtain wall unit. In addition, aluminum bars are treated by the latest CNC machine in order to achieve 3D section. Construction of curtain wall is highly focused from the moment of contract to keep the schedule because the contract period is 18 months. Regular design meeting and technical meeting between stakeholders including construction manager, designer, engineer, consultant and so on have been held during the construction to minimize the risks from the unique elevation and trial. Step by step mock-up test (design mock-up and visual mock-up on site) has been performed before functional mock-up test.

  • PDF

Heating and Cooling Load according to the Climatic Conditions of Foreign Cities (해외 주요 도시의 기후특성에 따른 최대공조부하 요소별 분석)

  • An, Seung-Hyun;Kim, Jong-Ho;Lee, Jung-Hun;Lee, Sang-Yup;Song, Doo-Sam
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.5
    • /
    • pp.81-87
    • /
    • 2014
  • According to the domestic construction business will continue stagnant, many domestic construction companies are expanding their business into foreign countries. As results, building design guidelines including HVAC design for foreign countries considering the regional climate conditions are needed. Also, green building design strategies to minimize the heating and cooling load are key issue to win a contract in construction business in the world. In this study, peak heating and cooling loads were calculated for the representative cities in the world : Seoul, St. Petersburg, Singapore and Mecca. The analyzed building was a typical high-rise office building and the building envelope properties, indoor heat gain, residence and operating schedules were same in all cases. Only the weather conditions were different by cases.

Evaluation of Thermal and Visual Environment for the Glazing and Shading Device in an Office Building with Installed of Venetian Blind (베네시안 블라인드가 적용된 오피스 건물의 외피 투과체 계획을 위한 열·빛 환경 평가에 대한 연구)

  • Kim, Chul-Ho;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.15 no.6
    • /
    • pp.101-109
    • /
    • 2015
  • Purpose: Glazing and shading devices influence a lot on the thermal and visual environment in office buildings. Solar heat and daylight are contrary concept, therefore proper arrangement of thermal and optical performance is needed when designing a glazing and shading devices. The purpose of this study is to examine the conditions of the glazing and shading devices available for promoting the reduction of cooling loads + lighting loads and the improvement in thermal comfort and visual comfort for the summer season in an office building installed with venetian blind. Method: This study established 12 simulation cases which have different glazings and the positions of venetian blind for evaluating different thermal and optical performance. And by using EnergyPlus v8.1 and Window v7.2 program, we quantitatively analyzed cooling loads + lighting loads, thermal comfort and visual comfort in an office building installed with the glazing and shading devices. Result: Consequently, Case 9(Double Low-E+Exterior Blind) is the best arrangement of solar heat gain and daylight influx, thereby becomes the most excellent case of reducing cooling+lighting loads(46.8%) and simultaneously becomes the enhancement case in thermal comfort. Also, DGI(Daylight glare index) under clear sky conditions in summer was evaluated to be 19.6, and thereby satisfied the recommendation level of allowing visual comfort.

The Analysis on the Variation of the Ventilation Rates by Wind Pressure and Temperature Difference between Indoor and Outdoor in the Multi-Story Type Double Skin Facade applied to the Office Building (오피스 건물에 적용된 다층형 이중외피의 풍압과 실내·외 온도차에 의한 환기량 변화 분석)

  • Song, Chi-Ho;Kim, Teayeon;Leigh, Seung-Bok
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.123-131
    • /
    • 2015
  • Purpose : Improvement of indoor thermal comfort and reduction of the energy consumption in building can be obtained by applying a double skin facade system. In order to achieve effectively this purpose, design team would have to perform easy and appropriate performance analysis for making better design decision during the design process. Method : This paper focus on the natural ventilation performance of a multi-story type double skin facade with main causes which are pressure difference according to the wind and temperature difference between indoor and outdoor (Buoyancy Effect). Using this main causes, the natural ventilation ratio of wind effect-to-buoyancy effect in cavity of multi-story type double skin facade were analyzed through the performance analysis results of CFD (Computational Fluid Dynamics) simulation. Result : When the wind velocity was 2m/s, the ventilation rate in the cavity was highest. If wind velocity was slower than 2m/s wind velocity, buoyancy effect has more influence on the ventilation rate in the cavity, and if wind velocity was faster than 2m/s wind velocity, wind effect has more influence on the ventilation rate in the cavity.

The Field Survey of Indoor Environment of the Office Building (오피스 건물의 실내 환경 실태 조사)

  • Yang, Young Kwon;Kang, In Sung;Chung, Min Hee;Moon, Jin Woo;Park, Jin Chul
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.71-76
    • /
    • 2016
  • Purpose: This study aimed at improving the indoor environment of the office building by measuring the indoor environment and conducting a survey. Method: The measurement was conducted from January 13 to March 16 in 2012, targeting 44 sites in same office building located in Seoul, South Korea. The lists of measurement such as dry-blub temperature, relative humidity, formaldehyde (HCHO), asbestos, carbon monoxide (CO), carbon dioxide (CO2), volatile organic compounds (VOCs) and particle pollution (PM10) were measured. In addition, illuminance which belongs to light environment and noise in sound[acoustical] environment were measured respectively. Result: The buildings showed overall pleasant conditions. In terms of the thermal, air, sound, and visual environment, each measurements were satisfied with the requirements in standard, within pleasant ranges, except several sites. However, the survey results were revealed that the office workers were mostly dissatisfied with their indoor environment. Given that the measured values were mostly within standards, the results of survey might have resulted from a compensation mentality biased toward the subjects in psychological terms.

Performance Based Design of Coupling Beam Considering Probability Distribution of Flexural and Shear Strength (휨강도와 전단강도의 확률분포를 고려한 연결보의 성능기반설계)

  • Kim, Yun-Gon;Cho, Suk-Hee
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.5
    • /
    • pp.509-516
    • /
    • 2013
  • In this paper, performance based design of coupling beam using non-linear static analysis is proposed considering probability distribution of flexural and shear strength in order to develop flexural hinge. This method considers post-yielding behavior of coupling beam and stress redistribution of system. It can verify the reduced effective stiffness to meet the current design requirement based on linear analysis. It also evaluates the lateral displacement under service load (un-factored wind load) properly. In addition, it can optimize the coupled shear wall system by taking stress redistribution between members into account. For a simplified 30-story building, non-linear static (push-over) analysis was performed and the structural behavior was checked at performance point and several displacement steps. Furthermore, system behavior according to the amount of reinforcement and depth of coupling beam was explored and compared each other.

Analysis for Fire Spread through Double Skin Facade System with FDS (화재시뮬레이션(FDS)을 이용한 Double Skin 연소확대 위험에 관한 고찰)

  • Huh, Yoon-Taek;Park, Chang-Bok;Sung, June-Shik;Yoon, Myong-O
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.110-116
    • /
    • 2009
  • This study is related with fire risk assessment for fire and smoke spread of double skin facade system by use of FDS (Fire Dynamics Simulator) which is a computational fluid dynamics (CFD) model of fire-driven fluid flow. For the study, fire scenario is intended to evaluate the impact of a fire spread for glazed office building. The major purpose of this study is to analyze the fire risk depending on the width of between inner skin and outer skin and to present fire prevention method regarding double skin facade system. The result of analysis presents fire spread more vertically as intermediate space becomes narrow. It is anticipated that fire can spread upper 2 stories above the fire floor if intermediate space with not more than 1m width. Therefore, prevention of vertical fire spread is required.