• Title/Summary/Keyword: 오선교

Search Result 51, Processing Time 0.023 seconds

A Method on the Control of Hydration Heat of Mass Concrete Considering the Difference of Setting Time (응결시간차를 활용한 매스콘크리트의 수화열 조정공법)

  • 심보길;윤치환;한민철;김기철;오선교;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.379-384
    • /
    • 2001
  • This Paper Presents field application test results of mass concrete using super retarding agent. The field test was carried out at mat foundation(thickness 1m) of newly constructed information center of Chongju university. Placing lift composed of 2 layers, and each layer is 50cm. Fly ash and flowing method is also applied. Difference of setting time of concrete between with super retarding agent and without super retarding agent is considered. Concrete without super retarding agent is placed at upper layer and with super retarding agent at lower layer According to test results, the reducing method of hydration heat considering difference of setting time with super retarding agent can reduce the highest temperature about 3~4$^{\circ}C$, and delay the peak time about 3~4days. Compressive strength using super retarding agent is somewhat higher than that of normal concrete. Accordingly, super retarding agent does not affect the strength development.

  • PDF

An Experimental Study on the Mock-up Test of Cold Weather Concreting Using Anti-freeze Agent and Insulating Form (내한제 및 단열거푸집을 이용한 한중콘크리트의 모의구조체 적용에 관한 실험 연구)

  • 김경민;손성운;김기철;오선교;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.663-668
    • /
    • 2002
  • In this paper, insulating effects and strength development of concrete placed at mock up model structure are discussed using anti freezing agent and insulating forms. According to test results, concrete containing 8% of anti freezing agent shows lower freezing temperature, earlier setting time and higher strength development than plain concrete. As for the temperature history of mock up structures, when plain concrete is placed at euro form, the temperature drops to -4${\circ}$ before early 24 hours, and when concrete containing anti freeze agent at euro form, it to -3${\circ}$ before early 24 hours. Nevertheless, when concrete containing anti freeze agent is placed at insulating form, it does not go below zero, and the concrete containing anti freeze agent enhances higher strength development.

  • PDF

Execution of Mass Concrete for Mat Foundation Using Setting Time Difference with Super Retarding Agent for Reducing Hydration Heat (초지연제의 응결시간차 공법을 이용한 기초 매트 콘크리트의 수화열 저감 시공)

  • Jeon Chung Keun;Yoon Chi Whan;Song Seung Heon;Shin Dong An;Oh Seon Gyo;Han Cheon Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.144-147
    • /
    • 2004
  • In this paper, field application of mass concreting using super retarding agent(SRA) are discussed based on setting. time difference with SRA in big discount market in Chongju. Mechanical and physical properties of .concrete are investigated. Temperature history of concrete is also measured. Slump and air content meet the requirement of target value. Compressive strength of concrete exceeded the nominal strength with 24MPa. Compressive strength of SRA concrete is higher than that of plain concrete by about $3\~4\%$. For temperature history, peak temperature of concrete at middle section at top concrete layer reached $49.6^{\circ}C$ within 24hours, and at bottom concrete layer, $54.6^{\circ}C$ within 42hours. Based on the naked eye's observation, no crack was found at mass concrete.

  • PDF

A Study on the Degree of Surface-Glossing of Exposed Concrete with the Kinds of Form Materials and Form Oils (거푸집 및 빅리제 종류에 따른 제치장 콘크리트의 광택도에 관한 연구)

  • 김효구;강의영;오선교;한천구;반호용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.197-202
    • /
    • 1999
  • The properties of surface-glossing of exposed concrete with the kinds of form materials and form oil are investigated under various slump value. According to the experimental results, surface-glossing has high value with the increase of slump. In case of surface-glossing with the kind of the form, the form made of acryl has the best performance among the form kinds tested in this experiment. The order of surface-glossing is follows ; fancy plywood > metal form > plywood. Water solution type form oil has better performance in surface-glossing than oil solution type form oil. Also, surface-glossing get worse with the elapse of age.

  • PDF

Temperature History of Concrete at Cold Weather Depending on the Kinds of Insulating Sheet (단열양생시트 종류 변화에 따른 한중콘크리트의 온도이력)

  • Jeon, Chung-Keun;Kim, Jong;Shin, Dong-An;Oh, Seon-Kyo;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.618-621
    • /
    • 2006
  • This paper is to investigate temperature history of cold weather concrete depending on insulation curing sheet kinds. Insulating effect according to curing sheet is shown in order of 5 layer bubble sheet, combination of PE form and 3 layer bubble sheet and 3 layer bubble sheet. It maintained above $10^{\circ}C$ of minimum temperature until the completion of initial curing period when bubble curing sheet was supplied regardless of curing sheet kinds. Five layer bubble curing sheet secure higher curing temperature than any other curing sheet applied in this experiment by as much as $2{\sim}3^{\circ}C$, which performed remarkable insulation effect. Concrete applied with curing sheet secured above $65^{\circ}D{\cdot}D$ of maturity, at which concrete had 5MPa of compressive strength at 3 days.

  • PDF

A Fundamental Study on the Improvement of Superplasticizer for Manufacturing the High Quality Flowing Concrete in the Field (고품질 현장 유동화 콘크리트 제조를 위한 유동화제 성능 개선에 관한 기초적 연구)

  • 강의영;한만철;오선교;한천구;반호용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04a
    • /
    • pp.33-36
    • /
    • 1998
  • Generally, the base concrete for manufacturing the flowing concrete has to increase the fine aggregate content or adjust the fines content prevent the concrete from segeration, However, it may not only increase the cost, but cause the inconvenience in production of base concrete. In this paper, the experiments is performed on the superplasticizer which is used for base concrete by mixing viscosity agents and AE admixtures. According to the results, it shows that it is possible to manufacture a flowing, non segregation, high durability and economical concrete in the field without increasing the fine aggregate content of base concrete, when the superplasticizer are mixed with viscosity agents and AE admixtures in an appropriate proportion.

  • PDF

Improvement of Surface Glossing of Exposed Concrete Applying Flowing Concrete Method -Focused on the Construction of the Service Training Institure (유동화 공법에 의한 제치장 콘크리트의 표면광택도 향상 -청주대학교 대천 수련원 공사를 중심으로-)

  • Jeon, Chung-Keun;Kim, Hyo-Goo;Oh, Sun-Kyo;Bahn, Ho-Yong;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.85-88
    • /
    • 2000
  • This paper is dealt with the ways of the improvement of the surface glossing of exposed concrete through the construction field test. The field applied in this test is located at Daechon, Chungnam province where the service training institute of Chongju university has been built. The flowing method is applied. According to the test results, as water to cement ratio, or slump increase after flowed, surface glossing tends to be improved. As for the effects of the forms typer, following orders, which is shown to be better surface glossing values, are given; Acryle > fancy wood forms > steel forms > plywood forms.

  • PDF

Influence of Mix Proportions and Form Types on the Surface-Glossing of Flowing Concrete (유동화 콘크리트의 표면 광택도에 미치는 배합 및 거푸집 요인의 영향)

  • 한천구;김효구;오선교;반호용
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.4
    • /
    • pp.15-22
    • /
    • 2000
  • The objective of this study is to investigate the degree of surface-glossing of flowing concrete, varying with W/C, types of forms and form oils. According to the experimental results, the degree of surface-glossing of flowing concrete is turned out to be higher than that of base concrete, as the slump increases. The degree of surface-glossing of concrete with 40% of W/C is higher than that with 50%. The orders of degree of surface-glossing with the types of forms are as follows : acryle > fancy plywood > metal form > plywood. When water solution type form oil is applied to the surface of forms, we can achieve higher degree of surface-glossing. It shows that the degree of surface-glossing decreases with elapsed time.

The Properties of Temperature History of Concrete with Surface Insulating Material in Cold Weather Concreting (한중콘크리트 시공시 표면 단열재 변화에 따른 콘크리트의 온도이력 특성)

  • 문학용;신동안;김경민;김기철;오선교;한천구
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.7-11
    • /
    • 2003
  • This study investigate the hydration heat history with variation of surface insulating material in cold weather concreting. According to the results, the temperature of concrete lowers below zero in 24hours, so early frost damage occurs in the case of exposure and 1 fold bubble sheet, but the lowest temperature keeps above zero, so a adiabatic effect is very favorable in the case of double bubble sheet and 부직포. Compressive strength of core specimen at 7 and 28 days is highest In the case of double bubble sheet and 부직포. But, considering convenience of construction and economical efficiency, it is thought that the most effective surface insulating material is 1 fold bubble sheet +blanket.

  • PDF

Field Construction Applying the Insulating Method of Moderate-Cold Weather Concreting Using Double Bubble Sheets (2중 버블시트를 이용한 한랭기 콘크리트의 단열양생공법 현장적용)

  • Kim, Jong;Kim, Jong-Back;Jeon, Chung-Keun;Shin, Dong-An;Oh, Seon-Gyo;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.29-32
    • /
    • 2006
  • Experimental test results of field construction, Cheongju University Educational Liberal Art Building, applying the insulating curing method on slab concrete showed that the quality of concrete in fresh and hardened state satisfied all target values. Temperature history of slab concrete in A and B area secured more than $7.8{\sim}9.2^{\circ}C$ higher than outside atmosphere. After completing certain curing period of time on the surface of the structure, crack occurrence was not found. It is concluded that the preventing vaporization of moisture by the insulating curing method reduces plastic and drying shrinkage as welt as improves durability.

  • PDF