• Title/Summary/Keyword: 예혼합

Search Result 853, Processing Time 0.022 seconds

An Experimental Study on Flame and $NO_x$ Emission Characteristics of Front Mixing Premix Combustor ($NO_x$ 선단 예혼합 연소기의 화염 및 $NO_x$ 배출 특성 연구)

  • Shin, Myung-Chul;Kim, Se-Won;Mun, Min-Uk
    • Journal of the Korean Society of Combustion
    • /
    • v.11 no.2
    • /
    • pp.22-27
    • /
    • 2006
  • This experimental study has been mainly motivated to obtain generally applicable design correlation for the front mixing premix combustor. The design concept of the front mixing premix combustor is to minimize thermal $NO_x$ and prompt $NO_x$ formation by maintaining low peak flame temperature, and nearly uniform flame temperature through rapid mixing process near the ignition point. The present experimental results clearly indicate that the front mixing premix combustor yields the $NO_x$ level lower than 43 ppm $NO_x$ emissions and the nearly uniform temperature distribution.

  • PDF

Simultaneous NOx, PM Reduction by the Late Injection & Fast Combustion Type Premixed Combustion Technology (지연분사급속연소방식 예혼합연소 기술에 의한 NOx, PM의 동시저감)

  • 김장헌;최인용;김창일
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.4
    • /
    • pp.31-35
    • /
    • 2004
  • A new combustion strategy called LIFC(Late Injection & Fast Combustion) was developed for simultaneous reduction of particulate matter(PM) and nitrogen oxides(NOx) in exhaust emission of diesel engines, In this study, effects of injection timing and injection pressure under relatively high EGR rate were investigated. The experiments were conducted in a conventional engine over a range of commercial engine speed. The test engine could be operated in LIFC up to 2000rpm / bmep 5 bar condition with significant reduction of NOx and PM. The experimental results showed potential for the mechanism of the simultaneous reduction of NOx and PM from HSDI diesel engines.

Observation on Double-droplet Combustion Speed in Premixed Spray Flame (예혼합 분무화염내의 이중적 액적 연소속도에 관한 관찰)

  • Lee, Chi-Woo;Shim, Han-Sub
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.6
    • /
    • pp.119-126
    • /
    • 2004
  • In order to elucidate the modes of double-droplet combustion speed in premixed spray flame, the difference between flame propagation speed and droplet cluster disappearance speed are experimentally investigated using a premixed spray burner system, It was confirmed that flame speed concerned with premixed-mode combustion in the spray flame was approximately 2.0 m/s in average while mean disappearance speed of droplet clusters, which were dominated by diffusion-mode combustion in downstream of the flame, was evaluated as much as 0.45 m/s. It was clarified that both characteristics of premixed-mode and diffusion-mode combustion in spray flames are of much difference in nature, even though both speed, which are supposed to depend on local properties of the spray itself and flow conditions surrounding droplet clusters, are scattered in experiments.

Flame Transfer Function Modeling in a Gas Turbine Partially-premixed Combustor with Equivalence Ratio Modulation (가스터빈 부분 예혼합 연소기에서 당량비 섭동에 대한 화염전달함수 모델링)

  • Kim, Jihwan;Kim, Daesik
    • Journal of ILASS-Korea
    • /
    • v.22 no.2
    • /
    • pp.55-61
    • /
    • 2017
  • This study has investigated the relationship between heat release fluctuations and the flow perturbations in a partially premixed gas turbine combustor using a commercial CFD code. Special focus of the current work is placed on the effect of equivalence ratio on the flame dynamics in a partially-premixed system. As the first step for this combustion dynamics study in the non-perfectly premixed combustor, flame behaviors are modeled and then compared with measured results under both steady and unsteady conditions. The calculated results of the flame transfer function with equivalence ratio fluctuation are found to well capture the main qualitative characteristics of the combustion dynamics for the partially-premixed flames.

Combustion Instability Modeling in a Partially-premixed Gas Turbine Combustor using Finite Element Method (유한요소법을 이용한 부분 예혼합 가스터빈 연소기에서의 연소불안정 모델링)

  • Jang, Segu;Kim, Deasik;Joo, Seongpil;Yoon, Youngbin
    • Journal of ILASS-Korea
    • /
    • v.23 no.1
    • /
    • pp.16-21
    • /
    • 2018
  • The current study has developed an in-house 3D FEM code in order to model thermoacoustic problems in a gas turbine combustion system and compared calculation results of main instability characteristics with measured ones from a lab-scale partially-premixed combustor. From the comparison of calculation results with the measured data, the current model could successfully capture the harmonic longitudinal instability frequencies and their spatial distributions of the acoustic field as well as the growth rate of self-excited modes.

The Characteristics of Combustion and Exhaust Emission according to Operating Condition and Fuel Composition in a Direct Injection Type HCCI Diesel Engine (직분식 예혼합 압축착화 디젤엔진의 운전조건과 연료조성에 따른 연소 및 배기 특성)

  • 이기형;류재덕;이창식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.1
    • /
    • pp.10-16
    • /
    • 2004
  • The Homogeneous Charge Compression Ignition (HCCI) engine has advantage for reducing the NOx and P.M. simultaneously. Therefore, HCCI engine is receiving attention as a low emission diesel engine concept. This study was carried out to investigate the characteristics of combustion and exhaust emission for operating conditions in a direct injection type of HCCI engines such as supercharged and naturally aspirated using diesel fuel and additive. From the experimental result, we found that cool flame was always appeared and also it was difficult to control combustion characteristics by changing the injection timing in HCCI. In addition, at the lean air-fuel ratio and high speed range, it was observed that charging air pressure, additive or increasing intake air temperature is effective to increase combustion performance and reduce exhaust emission. We concluded that chemical reaction by the increasing intake air temperature or additive without physical improvement has limitation for reduction of exhaust emission.

The Simulation of LES Model For Premixed Combustion around A Bluff Body (LES 모델을 적용한 Bluff-body 주위의 예혼합 연소 해석)

  • Jung, Eui-Man;Ku, Ja-Yeo
    • Journal of Aerospace System Engineering
    • /
    • v.3 no.4
    • /
    • pp.41-49
    • /
    • 2009
  • This paper present result of numerical simulation of premixed combustion around a triangle Bluff Body. And a numerical simulation of a premixed flame stabilization by a bluff body was performed using LES Model. The calculated results from the LES showed a good agreement with experiment data than k-model. Premixture combustion has flammability limit, quenching distance, smallest ignition energy has the combustion quality of the back. Bluff body makes a recirculation zone. Therefor velocity of behind bluff body is very slow. It was caused by slowly position speed and the fire occurred after the Bluff Body. Occurrence of fire it made the waste gas of high speed and the thrust made well.

  • PDF

Characteristics of Premixed Propane Flame in Electric Field according to Electrode Position (전극위치에 따른 전기장 내 프로판 예혼합 화염의 특성)

  • Taehun Kim;Minseok Kim;Hyemin Kim
    • Journal of ILASS-Korea
    • /
    • v.28 no.3
    • /
    • pp.134-142
    • /
    • 2023
  • Electric field assisted combustion is a method that reduces instability in lean combustion. In this study investigated the effects of electrode position on propane-air flame characteristic using a ring electrode. Results showed that burning velocity was not affected by electrode position, but positive voltage expanded the flammability limit while negative voltage contracted it. The effect of voltage polarity on the flammability limit decreased as the electrode position increased. Expanding the flammability limit with a positive voltage can reduce NOx emissions.

Lean Burn Combustion Characteristics of Propane Premixed Flame in Electric Field (전기장 인가에 따른 프로판 예혼합 화염의 희박연소 특성)

  • Minseok Kim;Junyoung Choi;Taehun Kim;Hyemin Kim
    • Journal of ILASS-Korea
    • /
    • v.28 no.1
    • /
    • pp.24-31
    • /
    • 2023
  • In this study, characteristics of a propane-air premixed flame sin DC electric field was investigated. The stainless steel Bunsen burner and the stainless steel ring were used as electrode, and the high voltage supply was used for applying electric field. Flammability range increased significantly when the positive voltage was applied because of extension of LBO limit, while it shrank when the negative voltage was applied. The reason for this was not much related to the burning velocity, but the induced flow around the burner by electric field. withNOx production slightly increased after positive voltage was applied in identical equivalence ratio. Nevertheless, it was advantageous to apply the positive electric field to reduce the NOx since the extension of LBO limit makes the burner possible to operate in very low equivalence ratio.

Flow Characteristics of Propane Premixed Flame on AC Electric Field (교류 전기장 인가에 따른 프로판 예혼합 화염의 유동 특성)

  • Boyun Kim;Minseok Kim;Taehun Kim;Ilsong Kweon;Hyemin Kim
    • Journal of ILASS-Korea
    • /
    • v.29 no.1
    • /
    • pp.38-44
    • /
    • 2024
  • This study investigates the flow characteristics of propane-air premixed flames on AC electric field using the Schlieren method. A voltage was applied to the ring electrode and the burner was grounded to form an electric field, and the applied voltage was fixed at 16 kV (Vpp). Results show that under the application of AC electric fields, flow around the flame oscillated only at frequencies below 50 Hz, and no oscillation was observed above this frequency range. Flame height oscillated with frequency in the range of 25 to 300 Hz, with frequency doubling observed in the range of 25 to 150 Hz. The flammability limit increased with frequency up to 250 Hz, but in the high-frequency range above 250 Hz, the flammability limit did not increased and converged.