• Title/Summary/Keyword: 예측선량

Search Result 169, Processing Time 0.032 seconds

Empirical Study on the Value Comparison Between Cosmic Radiation Measuring Instruments and Prediction Programs (항공기 탑재 우주방사선 측정장비와 예측프로그램의 비교값 실증연구)

  • Kyu-Wang Kim;Youn-Chul Choi
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.6
    • /
    • pp.755-762
    • /
    • 2023
  • The reliability of measuring instruments is essential in measuring cosmic radiation. To demonstrate this importance, this study measured and compared the amount of cosmic radiation using Liulin and TEPC, operated in South Korea, on a flight between Incheon, South Korea and LA, the US. In addition, since prior analysis based on a prediction program is necessary in advance to check the dose of cosmic radiation, this study utilized KREAM developed in Korea and the CARI-6M developed by the FAA to acquire the predicted value. As a result of the verification, the reliability of the two devices falls within the acceptable level of 20%, proving the reliability. Moreover, the differences between the values acquired by each prediction program were only subtle. Nevertheless, the analysis demonstrated that the prediction value obtained by the programs and the measured value had significant differences. Therefore, additional correction of the discrepancies or continuous research for such is required to match the predicted values are similar to the actual measured values.

A Study on the dose distribution produced by $^{32}$ P source form in treatment for inhibiting restenosis of coronary artery (관상동맥 재협착 방지를 위한 치료에서 $^{32}$ P 핵종의 선원 형태에 따른 선량분포에 관한 연구)

  • 김경화;김영미;박경배
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 1999
  • In this study, the dose distributions of a $^{32}$ p uniform cylindrical volume source and a surface source, a pure $\beta$emitter, were calculated in order to obtain information relevant to the utilization of a balloon catheter and a radioactive stent. The dose distributions of $^{32}$ p were calculated by means of the EGS4 code system. The sources are considered to be distributed uniformly in the volume and on the surface in the form of a cylinder with a radius of 1.5 mm and length of 20 mm. The energy of $\beta$particles emitted is chosen at random in the $\beta$ energy spectrum evaluated by the solution of the Dirac equation for the Coulomb potential. Liquid water is used to simulate the particle transport in the human body. The dose rates in a target at a 0.5mm radial distance from the surface of cylindrical volume and surface source are 12.133 cGy/s per GBq (0.449 cGy/s per mCi, uncertainty: 1.51%) and 24.732 cGy/s per GBq (0.915 cGy/s per mCi, uncertainty: 1.01%), respectively. The dose rates in the two sources decrease with distance in both radial and axial direction. On the basis of the above results, the determined initial activities were 29.69 mCi and 1.2278 $\mu$Ci for the balloon catheter and the radioactive stent using $^{32}$ P isotope, respectively. The total absorbed dose for optimal therapeutic regimen is considered to be 20 Gy and the treatment time in the case of the balloon catheter is less than 3 min. Absorbed doses in targets placed in a radial direction for the two sources were also calculated when it expressed initial activity in a 1 mCi/ml volume activity density for the cylindrical volume source and a 0.1 mCi/cm$^2$ area activity density for the surface source. The absorbed dose distribution around the $^{32}$ P cylindrical source with different size can be easily calculated using our results when the volume activity density and area activity density for the source are known.

  • PDF

A Study on the Use of Active Protocol Using the Change of Pitch and Rotation Time in PET/CT (PET/CT에서 Pitch와 Rotation Time의 변화를 이용한 능동적인 프로토콜 사용에 대한 연구)

  • Jang, Eui Sun;Kwak, In Suk;Park, Sun Myung;Choi, Choon Ki;Lee, Hyuk;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.67-71
    • /
    • 2013
  • Purpose: The Change of CT exposure condition have a effect on image quality and patient exposure dose. In this study, we evaluated effect CT image quality and SUV when CT parameters (Pitch, Rotation time) were changed. Materials and Methods: Discovery Ste (GE, USA) was used as a PET/CT scanner. Using GE QA Phantom and AAPM CT Performance Phantom for evaluate Noise of CT image. Images are acquired by using 24 combinations that four stages pitch (0.562, 0.938, 1.375, 1.75:1) and six stages X-ray tube rotation time (0.5s-1.0s). PET images are acquired using 1994 NEMA PET Phantom ($^{18}F-FDG$ 5.3 kBq/mL, 2.5 min/frame). For noise test, noise are evaluated by standard deviation of each image's CT numbers. And then we used expectation noise according to change of DLP (Dose Length Product) to experimental noise ratio for index of effectiveness. For spatial resolution test, we confirmed that it is possible to identify to 1.0 mm size of the holes at the AAPM CT Performance Phantom. Finally we evaluated each 24 image's SUV. Results: Noise efficiency were 1.00, 1.03, 1.01, 0.96 and 1.00, 1.04, 1.02, 0.97 when pitch changes at the QA Phantom and AAPM Phantom. In case of X-ray tube rotation time changes, 0.99, 1.02, 1.00, 1.00, 0.99, 0.99 and 1.01, 1.01, 0.99, 1.01, 1.01, 1.01 at the QA Phantom and AAPM Phantom. We could identify 1.0 mm size of the holes all 24 images. Also, there were no significant change of SUV and all image's average SUV were 1.1. Conclusion: 1.75:1 pitch is the most effective value at the CT image evaluation according to pitch change and It doesn't affect to the spatial resolution and SUV. However, the change of rotation time doesn't affect anything. So, we recommend to use the effective pitch like 1.75:1 and adequate X-ray tube rotation time according to patient size.

  • PDF

Development of a Dynamic Ingestion Pathways Model(KORFOOD), Applicable to Korean Environment (한국 환경에 적용 가능한 동적 섭식경로 모델 (KORFOOD) 개발)

  • Hwang, Won-Tae;Kim, Byung-Woo;Lee, Kun-Jai
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.1
    • /
    • pp.9-24
    • /
    • 1993
  • The time-dependent radioecological model applicable to Korean environment has been developed in order to assess the radiological consequences following the short-term deposition of radionuclides in an accident of nuclear power plant. Time-dependent radioactivity concentrations in foodstuffs can be estimated by the model called 'KORFOOD' as well as time-dependent and time-integrated ingestion doses. Three kinds of critical radionuclides and thirteen kinds of foodstuffs were considered in this model. Dynamic variation of radioactivities were simulated by considering several effects such as deposition, weathering and washout, resuspension, root uptake, translocation, leaching, senescence, intake and excretion of soil by animals, intake and excretion of feedstuffs by animals, etc. The input data to the KORFOOD are the time of the year when the deposition occurs, the kinds of radionuclides and foodstuffs for estimation. The time-dependent specific activities in rice and the ingestion doses due to the consumption of all considered foodstuffs were calculated with deposition time using agricultural data-base in Kori region. In order to validate results of KORFOOD, the calculated results were compared with those by a leading German model, ECOSYS-87. The comparison of results shows good agreements within a factor of ten.

  • PDF

An Intercomparison of Model Predictions for an Urban Contamination Resulting from the Explosion of a Radiological Dispersal Device (도심에서 방사능분산장치의 폭발로 인한 피폭선량 예측결과의 상호비교)

  • Hwang, Won-Tae;Jeong, Hyo-Jun;Kim, Eun-Han;Han, Moon-Hee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.1
    • /
    • pp.39-47
    • /
    • 2009
  • The METRO-K is a model for a radiological dose assessment due to a radioactive contamination in the Korean urban environment. The model has been taken part in the Urban Remediation Working Group within the IAEA's (International Atomic Energy Agency) EMRAS (${\mathbf{\underline{E}}}nvironmental$ ${\mathbf{\underline{M}}}odeling$ for ${\mathbf{\underline{RA}}}diation$ ${\mathbf{\underline{S}}}afety$) program. The Working Croup designed for the intercomparison of radioactive contamination to be resulted from the explosion of a radiological dispersal device in a hypothetical city. This paper dealt intensively with a part among a lot of predictive results which had been performed in the EMRAS program. The predictive results of three different models (METRO-K, RESRAD-RDD, CPHR) were submitted to the Working Group. The gap of predictive results was due to the difference of mathemathical modeling approaches, parameter values, understanding of assessors. Even if final results (for example, dose rates from contamintaed surfaces which might affect to a receptor) are similar, the understanding on the contribution of contaminated surfaces showed a great difference. Judging from the authors, it is due to the lack of understanding and information on radioactive terrors as well as the social and cultural gaps which assessors have been experienced. Therefore, it can be known that the experience of assessors and their subjective judgements might be important factors to get reliable results. If the acquisition of a little additional information is possible, it was identified that the METRO-K might be a useful tool for decision support against contamination resulting from radioactive terrors by improving the existing model.

  • PDF

Detection and Absorbed-Dose Estimation of Irradiated Enzyme Powder Using ESR Spectroscopy (ESR Spectroscopy를 이용한 방사선 조사 효소분말의 검지와 흡수선량 예측)

  • Chung, Hyung-Wook;Jeong, Jae-Young;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.1159-1163
    • /
    • 1999
  • Along with the increasing demands for food irradiation technology in the food industry, a proper detection means for controlling irradiated foods is required. Enzyme powder, which is permitted to be irradiated in Korea, was subjected to a detection trial by ESR spectroscopy. The high correlation coefficients were observed between the absorbed doses ranging from 2.5 to 15.0 kGy and the corresponding ESR signal intensity, such as $R^2$ = 0.9904 in gamma irradiation and $R^2$ = 0.9696 in electron beam. Pre-established threshold values for both non-irradiated control (1.19) and 2.5 kGy-irradiated samples (6.97 in gamma-ray; 7.36 in electron-beam) were successfully applicable to the detection of 30 coded unknown samples of enzyme powder. The calibration curves obtained from the samples irradiated at 2.5 to 15 kGy were expected to be potentially adopted to estimate absorbed doses ranging front 4 to 7 kGy with a quadratic equation.

  • PDF

A Correction Method of Dose to Attenuation Rate of Transmitting Photon Beam Through Couch Top for Radiosurgery Using Novalis (노발리스를 이용한 방사선 수술시 치료테이블을 투과하는 광자선의 감쇠율에 따른 선량 보정방법)

  • Kim, Sung-Joon;Shin, Hyun-Soo;Ko, Seung-Young;Park, Hye-Li;Kim, Ja-Young;Lee, Bo-Mi;Yea, Ji-Woon;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.12-17
    • /
    • 2011
  • This study has its own goal to deliver the accurate dose on the target volume by calculating and modifying the attenuation rate of photon beam transmitting the couch top with geometric model. The experiment was that the transmission rate and attenuation rate of photon beam transmitting the couch top was predicted by the geometric model, then compared and analyzed with what was measured experimentally based on that. The result showed that the predicted value by the geometric model accorded closely with the experimental value. In addition, in order to judge whether the practical clinical application is available, the point dose, measured after modifying the attenuation rate modelinged according to the treatment plan of a patient of spine radiosurgery, was compared with the one done nothing. The result was that the former showed decreased error range with treatment planned one than the latter. This papers calculated the transmission and attenuation rate with the geometric model transmitting the couch top and verified it experimentally. This method is expected to be very useful in not only the radiosurgery using Novalis but also the general radiation therapy.

Evaluation of the Minimum Shear Reinforcement Ratio of Reinforced Concrete Members (철근콘크리트 부재의 최소전단보강근비의 평가)

  • Lee Jung-Yoon;Yoon Sung-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.1 s.79
    • /
    • pp.43-53
    • /
    • 2004
  • The current Korean Concrete Design Code(KCI Code) requires the minimum and maximum content of shear s in order to prevent brittle and noneconomic design. However, the required content of the steel reinforcement In KCI Code is quite different to those of the other design codes such as fib-code, Canadian Code, and Japanese Code. Furthermore, since the evaluation equations of the minimum and maximum shear reinforcement for the current KCI Code were based on the experimental results, the equations can not be used for the RC members beyond the experimental application limits. The concrete tensile strength, shear stress, crack inclination, strain perpendicular to the crack, and shear span ratio are strongly related to the lower and upper limits of shear reinforcement. In this research, an evaluation equation for the minimum content of shear reinforcement is theoretical proposed from the Wavier's three principals of the mechanics of materials.

Measurement of Rectal Rodiation dose in the Patients with Uterine Cervix fencer using In Vivo Dosimetry(Diode Detector) (자궁경부암 환자에서 In vivo dosimetry(Diode detector)를 이용할 직장선량의 측정)

  • Kim, Sung-Kee;Kim, Wan-Sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.29-37
    • /
    • 2004
  • Purpose : A rectum and a bladder should be carefully considered in order to decrease side effects when HDR patient of uterine cervix cancer. Generally speaking, the value of dosimeter at a rectum and a bladder only depends on the value of a planning equipment, while some analyses of the value of dosimetry at rectum with TLD has been reported Or the contrary, it is hardly to find a report with in vivo dosimetry(diode detector). On this thesis, we would like to suggest the following. When a patient of uterine cervix cancer is in therapy, it is helpful to put a diode detector inside of a rectum in order to measure the rectal dose Based upon the result of the dosimetry, the result can be used as basic data at decreasing side effects. Materials and Methods : Six patients of uterine cervix cancer(four with tandem and ovoid, one with cylinder, and the other one with tandem and cylinder) who had been irradiated with HDR. Ir-192 totally 28 times from February 2003 to June 2003. We irradiated twice in the same distant spots with anterior film and lateral film whenever we measured with a diode detector. Then we did planning and compared each film. Results : The result of the measurement 4 patients with a diode detector is the following. The average and deviation from 3 patients with tandem and ovoid were $274.1{\pm}13.4cGy$, from 1 patient with tandem and ovoid were $126.1{\pm}7.2cGy$, from 1 patient with cylinder were $99.7{\pm}7.1cGy$, and from 1 patient with tandem and cylinder were $77.7{\pm}11.5cGy$. Conclusion : It is difficult to predict how the side effect of a rectum since the result of measurement with a diode detector depends on the state of a rectum. According to the result of the study, it is effective to use a TLD or an in vivo dosimetry and measure a rectum in order to consider the side effect. It is very necessary to decrease the amount of irradiation by controlling properly the duration of the irradiation and gauze packing, and by using shield equipments especially when side effects can be expected.

  • PDF

Radiation Absorbed Dose Measurement after I-131 Metaiodobenzylguanidine Treatment in a patient with Pheochromycytoma (갈색세포종 환자에서 Medical Internal Radiation Dose법을 이용한 I-131 Metaiodobenzylguanidine 치료 후 흡수선량 평가)

  • Yang, Weon-Il;Kim, Byeung-Il;Lee, Jae-Sung;Lee, Jung-Rim;Choi, Chang-Woon;Lim, Sang-Moo;Hong, Sung-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.422-429
    • /
    • 1999
  • Purpose: The measurement of radiation absorbed dose is useful to predict the response after I-131 labeled metaiodobenzylguanidine (MIBG) therapy and determine therapy dose in patients with unresectable or malignant pheochromocytoma. We estimated the absorbed dose in tumor tissue after high dose I-131 MIBG in a patient with pheochromocytoma using a gamma camera and Medical Internal Radiation Dose (MIRD) formula. Materials and Methods: A 64-year old female patient with pheochromocytoma who had multiple metastases of mediastinum, right kidney and periaortic lymph nodes, received 74 GBq (200 mCi) of I-131 MIBG. We obtained anterior and posterior images at 0.5, 16, 24, 64 and 145 hours after treatment. Two standard sources of 37 and 74 MBq of I-131 were imaged simultaneously. Cummulated I-131 MIBG uptake in tumor tissue was calculated after the correction of background activity, attenuation, system sensitivity and count loss at a high count rate. Results: The calculated absorbed radiation dose was 32-63 Gy/ 74 GBq, which was lower than the known dose for tumor remission (150-200 Gy). follow-up studies at 1 month showed minimally reduced tumor size on computed tomography, and mildly reduced I-131 MIBG uptake. Conclusion: We estimated radiation absorbed dose after therapeutic I-131 MIBG using a gamma camera and MIRD formula, which can be peformed in a clinical nuclear medicine laboratory. Our results suggest that the measurement of radiation absorbed dose in I-131 MIBG therapy is feasible as a routine clinical practice that can guide further treatment plan. The accuracy of dose measurement and correlation with clinical outcome should be evaluated further.

  • PDF