• Title/Summary/Keyword: 예열온도

Search Result 127, Processing Time 0.027 seconds

Numerical Study on Ignition Delay Time of CH4 as CO/H2 Addition in MILD Combustion (MILD 연소 환경에서 CO/H2 첨가에 따른 CH4의 점화 지연 시간의 해석적 연구)

  • Kim, Donghee;Huh, Kang Y.;Lee, Youngjae
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.2
    • /
    • pp.1-12
    • /
    • 2021
  • MILD(Moderate or Intense Low-oxygen Dilution) combustion has attracted attention as the clean thermal energy technology due to the lower emissions of unburnt carbon and NOx. MILD combustion aims to enlarge the combustion reaction zone using the spontaneous ignition phenomenon of the reactants. In this study, the ignition delay time of CH4 according to the initial temperature of reactants and the addition of CO, H2 was investigated using a numerical approach. Ignition delay time became shorter as the increases of initial temperature and H2 addition. But, CO addition to the fuel increase the ignition delay time. In case of H2 addition to the fuel, the ignition delay time decreased because the higher fraction of HO2 promotes the decomposition of methyl radical(CH3) and produce OH radical. However, in case of CO addition to the fuel, ignition delay time inceased because a high proportion of HCO consumes H radical. There was no significant effect of HCO on the reduction of ignition delay time. Also, the increase rates of NO emissions by the addition of CO and H2 were approximately 7% and 1%, respectively. A high proportion of NCO affects the increase in NO production rate.

Study on Hydrogen Production and CO Oxidation Reaction using Plasma Reforming System with PEMFC (고분자 전해질 연료전지용 플라즈마 개질 시스템에서 수소 생산 및 CO 산화반응에 관한 연구)

  • Hong, Suck Joo;Lim, Mun Sup;Chun, Young Nam
    • Korean Chemical Engineering Research
    • /
    • v.45 no.6
    • /
    • pp.656-662
    • /
    • 2007
  • Fuel reformer using plasma and shift reactor for CO oxidation were designed and manufactured as $H_2$ supply device to operate a polymer electrolyte membrane fuel cell (PEMFC). $H_2$ selectivity was increased by non-thermal plasma reformer using GlidArc discharge with Ni catalyst simultaneously. Shift reactor was consisted of steam generator, low temperature shifter, high temperature shifter and preferential oxidation reactor. Parametric screening studies of fuel reformer were conducted, in which there were the variations of the catalyst temperature, gas component ratio, total gas ratio and input power. and parametric screening studies of shift reactor were conducted, in which there were the variations of the air flow rate, stema flow rate and temperature. When the $O_2/C$ ratio was 0.64, total gas flow rate was 14.2 l/min, catalytic reactor temperature was $672^{\circ}C$ and input power 1.1 kJ/L, the production of $H_2$ was maximized 41.1%. And $CH_4$ conversion rate, $H_2$ yield and reformer energy density were 88.7%, 54% and 35.2% respectively. When the $O_2/C$ ratio was 0.3 in the PrOx reactor, steam flow ratio was 2.8 in the HTS, and temperature were 475, 314, 260, $235^{\circ}C$ in the HTS, LTS, PrOx, the conversion of CO was optimized conditions of shift reactor using simulated reformate gas. Preheat time of the reactor using plasma was 30 min, component of reformed gas from shift reactor were $H_2$ 38%, CO<10 ppm, $N_2$ 36%, $CO_2$ 21% and $CH_4$ 4%.

Thin Film Chromel-Alumel Multjunction Thermal Converter (박막형 크로멜-알루멜 다중접합 열전변환기)

  • Jung, In-Sik;Kim, Jin-Sup;Lee, Jung-Hee;Lee, Jong-Hyun;Shin, Jang-Kyoo;Park, Se-Il;Kwon, Sung-Won
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.9
    • /
    • pp.37-45
    • /
    • 1999
  • For the purpose of reducing the output voltage fluctuation of thin film multijunction thermal converter, EVANOHM alloy-S and chromel-alumel thermocouple were used as a thin film heater material and as a thermoelement of thrmopile, respectively. The temperature coefficient of the resistance of thin film EVANOHM alloy-S heater was about $1.4 {\times} 10^4/^{\circ}C$, which is very small compared to other materials, and thin film chromel-alumel thermocouple showed relatively small difference of the Seebeck coefficients about $38 {\mu}V/K$. The output voltage fluctuation of the thermal converter was about 0.06% for the initial 120 seconds in air and decreased considerably after preheating for 5 minutes or more. The respective AC-DC voltage and current transfer error ranges of the thermal converter were about ${\pm}$1.6 ppm and ${\pm}$0.7 ppm in the frequency range from 10Hz to 10 kHz and increased remarkably below 10 Hz or above 10 kHz.

  • PDF

Manufacturing of Watermelon Beverage Added with Natural Color Extracts (천연 색소 추출물을 첨가한 수박 음료의 제조)

  • Hwang, Young;Lee, Ki-Kwon;Jung, Gi-Tai;Ko, Bok-Rae;Choi, Dong-Chil;Choi, Joung-Sik;Eun, Jong-Bang
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.226-232
    • /
    • 2004
  • Dilution concentration of watermelon juice, concentrations of added sugar, citric acid, and vitamin C, sterilization temperature and time, and natural color extracts were evaluated to determine optimum conditions for watermelon beverage production. Optimum dilution concentration of watermelon juice and optimum content of soluble solid were 40% and $12^{\circ}Brix$, respectively. Addition of 0.5 and 0.3 g/L or 1.0 and 0.3 g/L citric acid and vitamin C gave optimum sensory quality. Sterilization of watermelon beverage at above $70^{\circ}C$ decreased redness. Sterilization at $60^{\circ}C$ for 10 to 30 min or at $70^{\circ}C$ for 10 min achieved best sensory quality. Addition of 20 g/L raspberries gave best sensory quality among raspberries, omija, and borage. Hot water was better than alcohol for extraction of natural color. Ratio of extracts for optimum sensory quality was 7 : 3 for extract of 20 g raspberries/L : extract of 30 g omija/L.

Performance Evaluation of an Electrometer for Quality Control and Dosimetry in Radiation Therapy (방사선 치료의 정도관리 및 선량측정에 이용되는 전리계의 성능평가)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.123-130
    • /
    • 2000
  • The performance of an electrometer directly affects on the accuracy and precision in radiation dosimetry. This study is to list of the quality control for maintaining performance and to perform evaluation tests of an electrometer. Performance tests selected include proper polarizing voltages, warm-up and equalization time, leakages, long-term stability, linearity, and effect of ambient conditions. An electrometer connected with a rigid stem ionization chamber was evaluated with a Strontium-90 check device. Bias voltage was measured directly on the input socket. Equalization time is the time required for reaching threshold of charged state after the power is on or the bias voltage is changed. Pre- and post-signal leakages are defined as the accumulation of signal with no exposure and after exposure, respectively. Over three months period, the electrometer's long-term stability was measured by comparison of the temperature-pressure corrected readings. Linearity was expressed as the deviation of readings from multiple short exposures from one continuous exposure. Effect of ambient conditions was expressed as the zero drift of the electrometer over 17-34$^{\circ}C$ temperature ranges. For two nominal values, 300 and 500 volts, measured voltages were lower by 2.5 and 5.8%, respectively. The warm-up time, 20 minutes, was longer than the lamp time by 9 minutes and the equalization time was less than 1 minute. Without exposure, the zero-drift was 0.002 scale-unit in 15 minutes and the leakage after 10 minutes exposure was minimal. The IQ-4 was stable over 99.4% for three-month periods. Deviation from the linearity was 0.9% for measurement scale, 0.000-9.991. Over 17-34$^{\circ}C$ temperature range, the zero-drift was minimal, less than 0.2%. For a clinically-used electrometer, a list for the basic peformance evaluations is proposed. By running this program, the measurement error using an electrometer can be reduced and in turn the improvement in accuracy and precision of radiation dosimetry can be achieved.

  • PDF

A Study of material analysis and its experimentation of metamorphosis and its utilities in Copper Alloy plates for contemporary metal craft (현대금속공예용 동합금판의 재료분석과 형질변환 실험 및 응용에 관한 연구)

  • Lim, Ock-Soo
    • Archives of design research
    • /
    • v.17 no.4
    • /
    • pp.241-250
    • /
    • 2004
  • In this research, the copper alloy plates C2200, C5210, C7701, C8113 were selected to make datum and to identify further usage of metal craft experimentation. For its experimentation, the general welding and TIG welding methods were researched; for 2nd experimentation, the Reticulation and Electroforming skill's differences in color and temperature were researched. With these methods 3 different kinds of works are introduced for sample studies. For this research, Dr. Lee, Dong-Woo who works in Poongsan Metal Co, supported 4 kinds of copper alloy metals. Which are Commercial bronze (Cu-Zn), Deoxidiged Copper(Cu-Sn-P), Nickel Silver (Cu-Ni-Zn), and White Bronze (Cu-Ni); they were applied partly and wholly by the method of Laminatin, Reticulation, Fusing, and Electroforming skills. In case of C2200, the brass, the A. C. TIG welding method is better under 2mm slight plate; the D.C. TIG welding is better upper 2mm plate; and 250~300$^{\circ}C$ is recommended for remain heat treatment. In case of C5210, not having Hydrogen in high temperature return period, doesn't need Oxygen in high temperature and hardening in comparative high temperature neither, it is good for welding. It contains Sn 2-9% ad P 0.03-0.4% generally; and in accordance with the growth rate of Sn contain amount, the harden temperature boundary become broad. In case of cold moment after welding, they are recommended that higher speed TIG welding, smaller melting site and less than 200$^{\circ}C$ for pre-heating temperature. In case of C7701, the 10-20% Ni, 15-30% Zn are widely used.. If it is upper 30% Zn, it become (${\alpha}+{\beta}$) system and adhesive power rate become lower, and the productivity become lower in low temperature but the productivity become higher in high temperature. Nickel Silver's resistance of electricity is well; and the heatproof and incorrodibility is good, too. Lastly, in case of C8113, good at persistence in salty and grind; high in strength of high temperature. In case of white brass, contain 10-30% Nickel and hardened in high temperature and become single phrase. For these reason, the crystallization particles easily become large, if the resistance become higher small amount of Pb, P, S separation rate become higher.

  • PDF

Effects of Pre-heat Treatments on Milk Protein and Microorganism Aspects in Raw Milk (예열처리(豫熱處理)가 원유(原乳)의 단백질(蛋白質) 및 미생물(微生物)에 미치는 영향(影響))

  • Kim, Seung Sub;Kim, Jong Woo
    • Korean Journal of Agricultural Science
    • /
    • v.20 no.2
    • /
    • pp.153-166
    • /
    • 1993
  • The experiments were conducted to improve raw milk quality during storage, the chemical composition and microbiological aspect of raw milk, milk thermized at $65^{\circ}C$ for 30 second, and $75^{\circ}C$ for 2 second stored at $5^{\circ}C$ for 4 days were investigated. The result obtained were summarized as follows : 1. During storage of raw and thermized milk, in the composition of milk fat, milk protein, lactose and total solid did not change significantly. 2. The range of pH and acidity for the raw milk were 6.73~5.94 and 0.16~0.27% respectively and those of the thermized milk were 6.79~6.62 and 0.16~0.17% respectively. The phosphatase test were negative in heated milk. 3. The composition of total nitrogen, NCN and whey protein were decreased, wherease those of NPN and casein were increased in heat treated milk. 4. The compositions of total nitrogen and casein were decreased as the storage period advanced, wherese those of NCN and NPN were increased. However, the composition of whey protein did not significantly change. 5. The number of coliform bacteria was not found in thermized milk. but were gradually increased in raw milk during storage period. 6. Raw milk had total bacteria count as $5.6{\times}10^6/ml$, psychrotrophic bacteria $1.8{\times}10^6/ml$ and thermoduric bacteria $1.6{\times}10^5/ml$, as the heat treatment increased microorganism counts decreased to milk thermized at $75^{\circ}C$, for 2 sec. $3.0{\times}10^3/ml$, $1.5{\times}10/ml$ and $2.7{\times}10^3/ml$ respectively. 7. The count of thermoduric bacteria, psychrotrophic bacteria and total bacteria were increased during storage period, and more rapidly increased in raw milk than in heat treated milk.

  • PDF