• Title/Summary/Keyword: 영하 온도

Search Result 112, Processing Time 0.023 seconds

A Study on Freezing Characteristics of Pavements Using Data of Test Road (시험도로 자료를 이용한 포장의 동결특성 연구)

  • Jeong, Jin-Hoon;Bae, Sung-Ho;Kwon, Soon-Min
    • International Journal of Highway Engineering
    • /
    • v.7 no.2 s.24
    • /
    • pp.87-95
    • /
    • 2005
  • To prevent the lowering of structural capability due to freezing and thawing in cold winter, numerous researches on frost heaving have been performed. As the result, the freezing index contour map of the Korea peninsula has been made for the design of the anti-freezing layer of pavements. However, the validity of the anti-freezing layer needs to be evaluated because systematic investigations on the variation of freezing depth with the thickness and material types of pavement layers and the configuration of the ground have been rarely performed. The freezing index of the Korea Highway Corporation test road site was calculated and the freezing depths of the concrete and asphalt pavements of the test road were investigated using the ambient and pavement temperature and water content. In addition, the investigated freezing depths were compared to the values estimated by existing freezing depth models. This is the preliminary study on the freezing-related data measured at the test road. The results with higher reliability will be produced by the long-term accumulation of the data and the analysis on it.

  • PDF

Spatiotemporal Changes of Temperature and Humidity in Lentinula edodes Cultivation Sheds (표고시설재배사내 시·공간적인 온·습도변화)

  • Ryu, Sung Ryul;Koo, Chang Duck
    • Journal of Korean Society of Forest Science
    • /
    • v.94 no.6
    • /
    • pp.468-475
    • /
    • 2005
  • To understand spatiotemporal changes of temperature and humidity in Lentimula edodes cultivation sheds, temperature, relative humidity were measured with HOBO H8 series sensors in log cultivation sheds and sawdust cultivation sheds. The results obtained from October in 2003 to October in 2004 were as follows; 1. Horizontal temperature changes were smaller at center of cultivation shed inside than comer of cultivation shed inside, while relative humidity changes were greater about 3% at center of cultivation shed inside than corner of cultivation shed inside. 2. Vertical temperature changes showed that the temperature was higher at above than at below when the temperature rises, while the temperature was lower at above than at below when the temperature falls. Thus close to soil surface temperature showed a little fluctuation. Vertical relative humidity changes showed that the relative humidity was lower at above than at below when the temperature rises, while the relative humidity was higher at above than at below when the temperature falls. After all temperature and relative humidity was the opposite in cultivation shed. 3. It's showed in log cultivation shed that the minimum temperature was a subzero temperature until the end of April, while the minimum temperature did above zero after the beginning of the May. Besides a winter was the greatest at daily temperature range during the four season, about $30^{\circ}C$. On the other hand the minimum relative humidity was less than 20% at April, May and June but more than 40% after May.

Effects of Aggregate and Curing Temperature on Strength Development of UP-MMA based Polymer Mortar under Sub-Zero Temperature (영하온도에서 UP-MMA 폴리머 모르타르의 강도 발현에 미치는 골재 및 양생온도의 영향)

  • Yeon, Kyu-Seok;Kim, Yong-Seong;Cha, Jin-Yun;Son, Seung-Wan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.5
    • /
    • pp.25-33
    • /
    • 2011
  • In this paper, the effects of aggregate and curing temperature on strength development characteristics of UP (Unsaturated Polyester)-MMA (Methyl Methacrylate) based polymer mortar under sub-zero temperature are experimentally investigated to provide a criterion for repair and production of precast products. The result showed that the setting time of the binder was 4 minutes at $20^{\circ}C$ whereas 35 minutes at $-20^{\circ}C$. The result also revealed that the compressive, flexural, and splitting tensile strengths of UP-MMA based polymer mortar significantly decreased as the aggregate and curing temperatures decreased. However, sufficient strengths which can be implemented in actual practices -36.6 MPa of compressive strength, 6.11 MPa of flexural strength, and 5.81 MPa of splitting tensile strength - were obtained even though both aggregate and curing temperatures were $-20^{\circ}C$. Strength development of polymer mortar is largely affected by curing temperature rather than aggregate temperature. It was found that the effects of aggregate temperature on strength development become smaller as the curing temperature becomes lower. Also, toughness, a ratio of compressive strength to flexural strength, increased from 3.5 to 5.9 as both aggregate and curing temperatures decreased from $20^{\circ}C$ to $-20^{\circ}C$.

The effect of dilution solvent ratio on dewaxing of waxy oils (Waxy Oil 탈납에 있어서 용제희석의 영향)

  • 김주항
    • Tribology and Lubricants
    • /
    • v.3 no.2
    • /
    • pp.34-43
    • /
    • 1987
  • The effect of dilution solvent ratio, and the mixing ratio of MEK and toluene on the solvent dewaxing process has been studied. The results of this study are Summarized as follows; 1. The best mixing ratio of solvent of MEK process and Toluene when in case of light and medium Waxy oils, which has low viscosity was 48: 52, and when in case of heavy waxy oil, which has high viscosity was 45: 55. 2. The best dilution solvent ratio when in case of low viscosity oils. was 1:2.8 against waxy oils after annexing 5 times divided as well as, when incase of high viscosity oil was 1:3.5 after annexing 2 times divided. 3. The chilling temperature was -26$\circ$C and the reguired dewaxing time depends on the viscosity of waxy oils.

Development of Lightweight DMFC System for Charging Secondary Battery in Military Operational Environment (군 운용환경에서 이차전지 충전을 위한 경량화 DMFC 시스템 개발)

  • LEE, SUWON;GWAK, GEONHUI;RO, JUNGHO;CHO, YOUNGRAE;KIM, DOYOUN;JU, HYUNCHUL
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.5
    • /
    • pp.481-491
    • /
    • 2017
  • In this study, we developed 300 W lightweight DMFC system for charging secondary battery in small unit military operation. In order to reduce the volumetric shape and weight of the system considering the environment of the individual soldier's, the arranging of system components has been optimized. A metal bipolar plates made of STS-470FC have been implemented to the DMFC stack to meet the weight demand of the system. As a result of the performance test of the stack, the target value was satisfied by outputting 561 W exceeding 24% of the stack output 450 W required to output 300 W required for the entire system. Moreover, 2,655 hours exceeding 1,000 hours also has been satisfied. To ensure good robustness of the metallic bipolar plate based DMFC stack, finite element method based simulations are conducted using a commercial ANSYS Fluent software.

Synthesis and Characterization of Poly(lactic-co-mandelic acid)s by Direct Solution Polycondensation (직접 용액 축중합에 의한 Poly(lactic acid-co-mandelic acid)의 합성 및 특성 조사)

  • 김완중;김지흥;김수현;김영하
    • Polymer(Korea)
    • /
    • v.24 no.3
    • /
    • pp.431-436
    • /
    • 2000
  • To improve the thermal and mechanical properties of homo poly(L-lactic acid), DL-mandelic acid, one of the natural $\alpha$-hydroxy acid with aromatic ring as the side-chain residue was used as the comonomer. Copolymers with different contents of mandelic acid were prepared and characterized. The resulting copolymers were mostly amorphous. As the amount of mandelic acid in the monomer feed increased, the molecular weight of the resulting polymers tended to decrease linearly. T$_{g}$ and T$_{d}$ of the copolymer, however, were found to shift toward higher temperature, suggesting the improved thermal stability by increasing content of mandelic acid moiety. Tensile measurements of cast films showed somewhat improved values in the copolymers with mandelic acid content of 5 and 10 wt%.%.%.

  • PDF

Experimental Study on the Sand and Gravel Embankment in Winter Season (사역재료의 동기성토에 관한 실험적연구)

  • 이형수
    • Water for future
    • /
    • v.6 no.2
    • /
    • pp.12-18
    • /
    • 1973
  • This paper describes the study and test for sand and gravel embankment in winter season and also contribute to the development of construction method for the practical purposes. In order to make possible sand and gravel embankment in winter season, at first, the following eriteria on work are given under the normal weather condition: 1) The maximum diameter of material shall not exceed 30cm and sand content which is the ratio of the weight of sand to gravel shall not exceed 60% 2) Spreading depth shall not exceed 60cm each layer of material shall be compacted by over 6 times passing by thell ton smooth drum type of uibratory roller and the relative density shall exceed 60% In addition to the above conditions, the following criteria are given as winter season condition. 3) Sand contsnt shall not exceed 25%, and water content shall not exceed 4% 4) Dwing construction, the air temperature should be $70^{\circ}C$ below zero at minimum and $3^{\circ}C$ below zero onthe average and all the construction work should he continued without intersuptions. With above criteria, it is come to a conclusion that the conclusion that the construction of sand and gravel embankment in winter season will be done satisfactorily without any difficulty. On the basis of these criteria an actual construction was practiced and it was proved that those criteria are applicable to actual embankment of materials.

  • PDF

Characteristic of Cabin Temperature According to Thermal Load Condition of Heat Pump for Electric Vehicle (전기자동차용 히트펌프의 열 부하 조건에 따른 캐빈온도 특성)

  • Park, Ji Soo;Han, Jae Young;Kim, Sung-Soo;Yu, Sang Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.2
    • /
    • pp.85-91
    • /
    • 2016
  • The Positive Temperature Coefficient (PTC) is used for cabin air heating of a battery electric vehicle, which is different from conventional vehicles. Since the PTC heater consumes a large quantity of power in a parasitic manner, many valuable studies have been reported in the field of alternative heat pumps. In this study, a model for an R134a heat pump taking into account the thermal environment of the cabin was developed for a MATLAB/SIMULINK(R) platform. Component and cabin models are validated with reference values. Results show that the heat pump is more competitive for parasitic power consumption over all ambient temperature conditions. Additionally, the method of waste heat recovery to overcome disadvantages when temperatures are below zero is applied to efficiently operate the heat pump.

Optimal Heating Location for developing the Heating Smart Clothing based on Thermal Response of Body (발열 기능 스마트 의류를 위한 인체 온열반응 기반의 최적의 발열위치 연구)

  • Cho, Hakyung;Cho, Sangwoo
    • Science of Emotion and Sensibility
    • /
    • v.18 no.3
    • /
    • pp.93-106
    • /
    • 2015
  • In accordance with escalating demands for advanced technology products, the smart clothing that includes embedded ICT technology have expanded into fields of daily life. As a result of this trend, interest in smart clothing with digitally controllable heating has rapidly grown and the market for smart heated clothing has also expanded. Increasing of prospect in smart heated clothing market, the effectiveness and thermal sensation research of the location on the pad attached is insufficient. This study was conducted to find the optimal location of heated clothing via experimental research on changes in skin temperature and subjective thermal sensation when heating pads were placed on different areas of the body. For this experiment, the subjects consisted of 10 males in their 20's of standard physique. The skin temperature at 11 different areas of the body, rectal temperature, and subjective thermal sensation were taken at different stages (before testing, after a 20 minute rest period, 20 minute treatment period, and after a 40 minute recovery period) in an artificial-climate chamber at $-5^{\circ}C$. As a result, the optimal location for heating pads in smart clothing was estimated and suggested.

Utilization of Waste Tries in Cement Kiln as an Energy Source (시멘트 소성공정에서 폐타이어의 효율적 열이용 연구)

  • 노갑수;서형석;이영조;김영하;최명일
    • Resources Recycling
    • /
    • v.4 no.4
    • /
    • pp.37-58
    • /
    • 1995
  • Whole tues were put uto cement kiln inlet where the tempmalures or gas and cemcnt-raw-materials were 1050 and 800- 850.C. respcclrvely. Tl~ck iln consisls of \ulcorner-stage suspension preheatel- and air quenching coolers The amount of wusle tlrcs added in lhc normal encrgy in lhc ce~ncnlk iln was 3, 5, 7% by volume Welght and steel contents of tiles. ulti~~iaalcn d elemental analysis, ash contents. ash hsion temperature. etc, wete detcnutned to inveshgate thc prnpcrlics a1 tires and ilreir ashes. Flucluat~ons of cement kiln placess, cement quality and an pollulton were invesligalerl during lhc burning tins. When the Ieeding ralio ol wasle lires to normal cncrgy was 50'0, there was nn wlde d~ffereilces m the cemmt quctlity and air pollutcon between operation with tiles and withoul tires. Tl~ch cal iccovcry was uhout 50% w~th5 % add~tionI n the nonndl energy. There was a little lxt fluctuation of cement quultty ncld an pollution at olher feeding ralios.

  • PDF