• Title/Summary/Keyword: 영상화질평가

Search Result 481, Processing Time 0.024 seconds

Image Evaluation of Resolution Parameter and Reconstitution Filter in 256 Multi Detector Computed Tomography by Using Head Phantom (256 다중 검출기 전산화단층촬영에서 두개부 전용 팬톰을 이용한 분해능 파라메터와 재구성 필터의 영상 평가)

  • Gu, Bon-Seung;Seoung, Youl-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.12
    • /
    • pp.814-821
    • /
    • 2011
  • The purpose of this study was to evaluate of resolution parameter and reconstitution filter in the 256 multi detector computed tomography(MDCT) by using the head phantom. We used 256 MDCT, and head phantom of philips system. We evaluated to image quality by using Extended Brilliance Workspace. The protocol were axial scan method with 120 kVp, 0.5 sec of rotation time, 5 mm of slice thickness and increment, 250 mm of field of view(FOV), $512{\times}512$ of matrix size, 1.0 of pitch, $128{\times}0.625$ mm of collimations. The resolution parameter was applied for 'Standard', 'High' and 'Ultrahigh'. The reconstitution filters were changed to seven type of 'A', 'B', 'C', 'D', 'UA', 'UB', 'UC'. The assesment factors of image quality were the uniformity, the noise, the linearity and 50% and 10% of the modulation transfer function(MTF). Finally The good image quality in 'High' resolution parameter showed at the uniformity, the linearity and 50% and 10% of MTF. The 'UA', 'UB' reconstitution filter showed at the good image quality of the uniformity and the noise and 'C' reconstitution filter showed at the same result of the linearity and 50% and 10% of MTF.

Adaptive Postprocessing Technique for Compressed Images using Directional Activity-based Block Analysis (방향성 활동도 기반 블록 분석을 통한 압축 영상의 적응적 후처리 기법)

  • Kim, Jongho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.7
    • /
    • pp.1687-1693
    • /
    • 2013
  • This paper addresses an adaptive postprocessing technique to remove blocking effects of the highly compressed images. The proposed technique removes blocking effects selectively by applying filters with different strength according to block analysis based on the directional activity. One-dimensional filters which are used to remove grid noises accomplish the adaptive filtering to the signal itself as well as to the directionality of the block. Moreover, we propose a detection method of the staircase noises and corner outliers and a two-dimensional directional filter to remove them. Experimental results for various images and bitrates show that the proposed method outperforms the conventional methods in PSNR for the objective performance and GBIM for the subjective quality evaluation.

A Study on IPTV Video Quality by Routing Protocols in Wireless LAN (무선 LAN 환경에서 경로 배정 프로토콜에 따른 IPTV 영상 서비스 품질에 관한 연구)

  • Jung, Jae-hoon;Park, Seung-seob
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.572-575
    • /
    • 2009
  • With the advent of integration environment of broadcasting and communication, IPTV has been widely used. It provides services such as information, movie contents and broadcasting through TV using super-high speed networks. Developments of Wireless LAN and IP network technology create various and fusional services such as IPTV, VoIP that are based on IP network. The development of Wireless LAN is very important in IPTV network field which requires the best quality of service on the security, QoS and bandwidth. In this Paper, We configure the experimental network in its RIP and OSPF environment to test the Video Quality of IPTV in Wireless LAN. We measure and evaluate broadcasting quality by using PSNR to show the corelation of Routing Protocols in Wireless LAN in which how they affect to the IPTV real-time Video Quality.

  • PDF

Evaluation of Usefulness of Automatic Exposure Control (AEC) by Comparison Analysis of Entrance Surface Dose (ESD) and Entropy in Clinical Application of Digital Radiography (DR) (디지털 방사선 시스템의 노출 유형에 따른 임상 적용 시 입사표면선량 및 Entropy 비교분석을 통한 자동노출제어장치의 유용성 평가)

  • Choi, Ji-An;Hwang, Jun-Ho;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.8
    • /
    • pp.276-283
    • /
    • 2019
  • The purpose of this study is to evaluate the usefulness of automatic exposure control (AEC) by analyzing entrance surface dose (ESD) and entropy on using automatic exposure and manual exposure. The experimental method was to measure the dose by placing a semiconductor dosimeter on the Rando Phantom for the Pelvis, Abdomen, Skull, and Chest regions. The DICOM file was simultaneously acquired and then entropy was analyzed by using Matlab. As a result, when using the automatic exposure control, dose of all sites was lower than manual exposure's dose and entropy was high. In addition, paired t-test was performed for each item and p<0.05 was found in each item. In conclusion, the use of automatic exposure control can be a useful method to contribute to the optimization of the exposure dose and the image quality by reducing the amount of unnecessary radiation amount and information loss that can occur in X-ray examination.

A Wavelet-Domain IKONOS Satellite Image Fusion Algorithm Considering the Spectrum Range of Multispectral Images (다중분광 영상의 색상별 스펙트럼 영역을 고려한 웨이블릿 변역 IKONOS 위성영상 융합 알고리즘)

  • Lee, Young-Gun;Kuk, Jung-Gap;Cho, Nam-Ik
    • Journal of Broadcast Engineering
    • /
    • v.16 no.1
    • /
    • pp.14-22
    • /
    • 2011
  • The conventional satellite image fusion methods usually add the same amount of higher frequency components extracted from the panchromatic image to all the multispectral images. However, it is noted that each of multispectral images has different amount of overlap with the panchromatic image in terms of its spectrum, and also has different intensities. Thus giving the same amount of high frequency contents to all the spectral bands does not match with this observation, which causes color distortion in the fused image. In this paper, we propose a new wavelet-domain satellite image fusion algorithm that can compensate for these differences in intensity and spectrum overlap. For the compensation of intensity differences, we first estimate the high resolution multispectral images from P, considering the relative intensity ratios. For the compensation of the amount of spectral overlap, their wavelet coefficients are appended to the conventional wavelet-domain method where the coefficients for the addition is determined by the amount of spectrum overlap. Experiments are conducted for the IKONOS satellite images whose spectrums are well known, and the results show that the proposed algorithm gives higher PSNR and correlation coefficients compared to the conventional methods.

3D Fusion Imaging based on Spectral Computed Tomography Using K-edge Images (K-각 영상을 이용한 스펙트럼 전산화단층촬영 기반 3차원 융합진단영상화에 관한 연구)

  • Kim, Burnyoung;Lee, Seungwan;Yim, Dobin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.523-530
    • /
    • 2019
  • The purpose of this study was to obtain the K-edge images using a spectral CT system based on a photon-counting detector and implement the 3D fusion imaging using the conventional and spectral CT images. Also, we evaluated the clinical feasibility of the 3D fusion images though the quantitative analysis of image quality. A spectral CT system based on a CdTe photon-counting detector was used to obtain K-edge images. A pork phantom was manufactured with the six tubes including diluted iodine and gadolinium solutions. The K-edge images were obtained by the low-energy thresholds of 35 and 52 keV for iodine and gadolinium imaging with the X-ray spectrum, which was generated at a tube voltage of 100 kVp with a tube current of $500{\mu}A$. We implemented 3D fusion imaging by combining the iodine and gadolinium K-edge images with the conventional CT images. The results showed that the CNRs of the 3D fusion images were 6.76-14.9 times higher than those of the conventional CT images. Also, the 3D fusion images was able to provide the maps of target materials. Therefore, the technique proposed in this study can improve the quality of CT images and the diagnostic efficiency through the additional information of target materials.

Comparison Study on CNR and SNR of Thoracic Spine Lateral Radiography (흉추 측면검사 영상의 CNR과 SNR 측정의 비교 연구)

  • Kim, Ki-Won;Min, Jung-Whan;Lyu, Kwang-Yeul;Kim, Jung-Min;Jeong, Hoi-Woun;Lee, Joo-Ah;Jung, Jae-Hong;Sung, Dong-Chan;Park, Soon-Cheol
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.273-280
    • /
    • 2013
  • This study was proven for the T-spine breathing technique in lateral projection, using computer radiography (CR), charge coupled device (CCD), indirect digital radiography (IDR) and direct digital radiography (DDR). All images were evaluated and compared with CNR and SNR measured with the mean pixels and the standard deviation as setting ROI of spinous process, pedicle, vertebral body, intervertebral foramen and intervertebral disk using Image J. In experiment results of 4 type detectors, T-spine breathing technique was indicated as excellent in ROI of spinous process, pedicle, vertebral body, intervertebral foramen and intervertebral disk. As T-spine breathing technique indicated excellent images compared to the existing T-spine lateral radiography, this method would be useful for elderly patients who have difficulty in deep exhalation. This study was indicated the application possibility of T-spine breathing technique by presenting contrast to noise ratio (CNR) and signal to noise ratio (SNR) with quantitative value in 4 type detectors.

Establishment of Quality Control System for Angiographic Unit (IVR장치의 성능 평가 기준 개발)

  • Kang, Byung-Sam;Son, Jin-Hyun;Kim, Seung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.1
    • /
    • pp.236-244
    • /
    • 2011
  • Recently, the number of interventional procedures has increased dramatically as an alternative of invasive surgical procedure. The need for the quality control program of the angiographic units has also increased, because of concerns about the increased patient dose and the importance of image quality of angiographic units for the successful procedures. The purpose of this study was to propose an optimal guideline for the quality control program of the angiographic units. We reviewed domestic and international standards about medical imaging system and we evaluated the quality of 61 angiographic units in Korea with the use of NEMA 21 phantom. According to the results of our study, we propose a guideline for the quality control program of the angiographic units. Quality control program includes tube voltage test, tube current test, HVL test, image-field geometry test, spatial resolution test, low-contrast iodine detectability test, wire resolution test, phantom entrance dose test. Proposed reference levels are as follows: PAE < $\pm$ 10% in tube voltage test, PAE < $\pm$ 15% in tube current test, minimum 2.3 mmAl at 80 kVp in HVL test, minimum 'acceptable' level at image-field geometry test, 0.8 lp/mm for detector size of 34-40cm, 1.0 lp/mm for detector size of 28-33cm, 1.2 lp/mm for detector size of 22-27cm in spatial resolution test, minimum 200mg/cc in low contrast iodine detectability test, phantom entrance dose should be under 10R/min, 0.012 inch wire should be seen at static wire resolution test, and 0.022 inch wire should be seen at moving wire resolution test.

The Evaluation for Attenuation Map using Low Dose in PET/CT System (PET/CT 시스템에서 감쇠지도를 만들기 위한 저선량 CT 평가)

  • Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Lee, Chang-Lae;Lim, Han-Sang;Park, Hoon-Hee;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.134-138
    • /
    • 2007
  • The current PET/CT system with high quality CT images not only increases diagnostic value by providing anatomic localization, but also shortens the acquisition time for attenuation correction than primary PET system. All commercially available PET/CT system uses the CT scan for attenuation correction instead of the transmission scan using radioactive source such as $^{137}Cs,\;^{68}Ge$. However the CT scan may substantially increase the patient dose. The purpose of this study was to evaluate quality of PET images reconstructed by CT attenuation map using various tube currents. in this study, images were acquired for 3D Hoffman brain phantom and cylindrical phantom using GE DSTe PET/CT system. The emission data were acquired for 10 min using phantoms after injecting 44.03 MBq of $^{18}F-FDG$. The CT images for attenuation map were acquired by changing tube current from 10 mA to 95 mA with fixed exposure time of 8 sec and fixed tube voltage of 140 kVp. The PET images were reconstructed using these CT attenuation maps. Image quality of CT images was evaluated by measuring SD (standard deviation) of cylindrical phantom which was filled with water and $^{18}F-FDG$ solution. The PET images were evaluated by measuring the activity ratio between gray matter and white matter in Hoffman phantom images. SDs of CT images decrease by increasing tube current. When PET images were reconstructed using CT attenuation maps with various tube currents, the activity ratios between gray matter and white matter of PET images were almost same. These results indicated that the quality of the PET images using low dose CT data were comparable to the PET images using general dose CT data. Therefore, the use of low dose CT is recommended than the use of general dose CT, when the diagnostic high quality CT is not required. Further studies may need to be performed for other system, since this study is limited to the GE DSTe system used in this study.

  • PDF

Performance Analysis of Implementation on Image Processing Algorithm for Multi-Access Memory System Including 16 Processing Elements (16개의 처리기를 가진 다중접근기억장치를 위한 영상처리 알고리즘의 구현에 대한 성능평가)

  • Lee, You-Jin;Kim, Jea-Hee;Park, Jong-Won
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.49 no.3
    • /
    • pp.8-14
    • /
    • 2012
  • Improving the speed of image processing is in great demand according to spread of high quality visual media or massive image applications such as 3D TV or movies, AR(Augmented reality). SIMD computer attached to a host computer can accelerate various image processing and massive data operations. MAMS is a multi-access memory system which is, along with multiple processing elements(PEs), adequate for establishing a high performance pipelined SIMD machine. MAMS supports simultaneous access to pq data elements within a horizontal, a vertical, or a block subarray with a constant interval in an arbitrary position in an $M{\times}N$ array of data elements, where the number of memory modules(MMs), m, is a prime number greater than pq. MAMS-PP4 is the first realization of the MAMS architecture, which consists of four PEs in a single chip and five MMs. This paper presents implementation of image processing algorithms and performance analysis for MAMS-PP16 which consists of 16 PEs with 17 MMs in an extension or the prior work, MAMS-PP4. The newly designed MAMS-PP16 has a 64 bit instruction format and application specific instruction set. The author develops a simulator of the MAMS-PP16 system, which implemented algorithms can be executed on. Performance analysis has done with this simulator executing implemented algorithms of processing images. The result of performance analysis verifies consistent response of MAMS-PP16 through the pyramid operation in image processing algorithms comparing with a Pentium-based serial processor. Executing the pyramid operation in MAMS-PP16 results in consistent response of processing time while randomly response time in a serial processor.