• Title/Summary/Keyword: 영상촬영기하

Search Result 181, Processing Time 0.034 seconds

Development of Unmatched System Model for Iterative Image Reconstruction for Pinhole Collimator of Imaging Systems in Nuclear Medicine (핀홀콜리메이터를 사용한 핵의학영상기기의 순환적 영상 재구성을 위한 비동일 시스템 모델 개발)

  • Bae, Jae-Keon;Bae, Seung-Bin;Lee, Ki-Sung;Kim, Yong-Kwon;Joung, Jin-Hun
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.353-360
    • /
    • 2012
  • Diverse designs of collimator have been applied to Single Photon Emission Computed Tomography (SPECT) according to the purpose of acquisition; thus, it is necessary to reflect geometric characteristic of each collimator for successive image reconstruction. This study carry out reconstruction algorithm for imaging system in nuclear medicine with pinhole collimator. Especially, we study to solve sampling problem which caused in the system model of pinhole collimator. System model for a maximum likelihood expectation maximization (MLEM) was developed based on the geometry of the collimator. The projector and back-projector were separately implemented based on the ray-driven and voxel-driven methods, respectively, to overcome sparse sampling problem. We perform phantom study for pinhole collimator by using geant4 application for tomographic emission(GATE) simulation tool. The reconstructed images show promising results. Designed iterative reconstruction algorithm with unmatched system model effective to remove sampling problem artefact. Proposed algorithm can be used not only for pinhole collimator but also for various collimator system of imaging system in nuclear medicine.

Three Dimensional Analysis of the Whole Interior-Surface of Structures by Multiple Close-Range Photogrammetry (다중근접사진측량에 의한 구조물 내부전면의 3차원 해석)

  • 이진덕;강준묵
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.11 no.1
    • /
    • pp.7-18
    • /
    • 1993
  • In analyzing whole surface of non-topographic objects, the design of multi-station photogrammetric network must involve a number of questions such as geometric configuration of exposure stations, imaging geometry, control point configuration or weight allowance of adjustments. Above all, the surveying of the interior of narrow longitudinal structures needs the design of special photogrammetric network. The main objective of this paper is to suggest the schemes for solving difficult problems attendant upon whole inside-surface analysis of structure and to improve the accuracy and reliability of final measurements. For it, the multi-station exposure network suitable to shape and size of the inside of the structure was designed. Then three dimensional data were acquired by bundle adjustments derived from multi-station photos and the effects of network design factors on accuracy of measurements were contemplated. Also, the algorithm for detection of blunders was developed here is expected to lead to improvement of the reliability of photogrammetric solutions.

  • PDF

High Resolution Depth-map Estimation in Real-time using Efficient Multi-threading (효율적인 멀티 쓰레딩을 이용한 고해상도 깊이지도의 실시간 획득)

  • Cho, Chil-Suk;Jun, Ji-In;Choo, Hyon-Gon;Park, Jong-Il
    • Journal of Broadcast Engineering
    • /
    • v.17 no.6
    • /
    • pp.945-953
    • /
    • 2012
  • A depth map can be obtained by projecting/capturing patterns of stripes using a projector-camera system and analyzing the geometric relationship between the projected patterns and the captured patterns. This is usually called structured light technique. In this paper, we propose a new multi-threading scheme for accelerating a conventional structured light technique. On CPUs and GPUs, multi-threading can be implemented by using OpenMP and CUDA, respectively. However, the problem is that their performance changes according to the computational conditions of partial processes of a structured light technique. In other words, OpenMP (using multiple CPUs) outperformed CUDA (using multiple GPUs) in partial processes such as pattern decoding and depth estimation. In contrast, CUDA outperformed OpenMP in partial processes such as rectification and pattern segmentation. Therefore, we carefully analyze the computational conditions where each outperforms the other and do use the better one in the related conditions. As a result, the proposed method can estimate a depth map in a speed of over 25 fps on $1280{\times}800$ images.

A Study on MR Imaging Method for The Patient with Inserting Shoulder Joint Suture Anchor (견관절 삽입술을 시행한 환자의 자기 공명 영상법에 관한 연구)

  • Park, Eui-Cheol;Bae, Seok-Hwan;Ryu, Yeun-Chul;Park, Young-Joon;Kim, Yong-Gwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.513-519
    • /
    • 2021
  • Metallic suture anchors are very useful and common fixation devices that are inserted into the target bone to sustain the tendon of a patient with musculus supraspinatus tendon ruptures. On the other hand, the presence of a metallic material prosthesis, such as a metal suture anchor, causes severe MR imaging artifacts, including field distortion, signal loss, and failure of fat suppression. The difference in magnetic susceptibility between metal and other organic materials causes magnetic field distortion surrounding the prosthesis. The resulting magnetic field inhomogeneity makes the images with a lower signal-to-noise ratio and distortion. For a patient with a suture anchor implanted, MR imaging is the golden standard for determining the postoperative prognosis, and a fat-saturation sequence is one of the imaging methods most affected by metal-induced artifacts. In this study, three fat-saturation sequences were compared. Artifact quantification and contrast comparison between the supraspinatus tendon and the surrounding muscle were presented. The images obtained using the STIR pulse sequence showed fewer susceptibility artifacts and better visibility in the supraspinatus tendon and the tissue area. Therefore, the STIR sequence is the most appropriate fat-saturation imaging method for patients with a metallic prosthesis.

Comparison of Multi-angle TerraSAR-X Staring Mode Image Registration Method through Coarse to Fine Step (Coarse to Fine 단계를 통한 TerraSAR-X Staring Mode 다중 관측각 영상 정합기법 비교 분석)

  • Lee, Dongjun;Kim, Sang-Wan
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.3
    • /
    • pp.475-491
    • /
    • 2021
  • With the recent increase in available high-resolution (< ~1 m) satellite SAR images, the demand for precise registration of SAR images is increasing in various fields including change detection. The registration between high-resolution SAR images acquired in different look angle is difficult due to speckle noise and geometric distortion caused by the characteristics of SAR images. In this study, registration is performed in two stages, coarse and fine, using the x-band SAR data imaged at staring spotlight mode of TerraSAR-X. For the coarse registration, a method combining the adaptive sampling method and SAR-SIFT (Scale Invariant Feature Transform) is applied, and three rigid methods (NCC: Normalized Cross Correlation, Phase Congruency-NCC, MI: Mutual Information) and one non-rigid (Gefolki: Geoscience extended Flow Optical Flow Lucas-Kanade Iterative), for the fine registration stage, was performed for performance comparison. The results were compared by using RMSE (Root Mean Square Error) and FSIM (Feature Similarity) index, and all rigid models showed poor results in all image combinations. It is confirmed that the rigid models have a large registration error in the rugged terrain area. As a result of applying the Gefolki algorithm, it was confirmed that the RMSE of Gefolki showed the best result as a 1~3 pixels, and the FSIM index also obtained a higher value than 0.02~0.03 compared to other rigid methods. It was confirmed that the mis-registration due to terrain effect could be sufficiently reduced by the Gefolki algorithm.

Evaluation of Dose Distribution of 6 MV X-ray using Optical Dosimetry (광 도시메트리시스템을 이용한 치료용 6 MV X선 선량분포 평가)

  • Kim, Sunghwan
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.925-932
    • /
    • 2019
  • In this paper, we developed optical dosimetry system with a plastic scintillator, a commercial 50 mm, f1.8 lens, and a commercial high-sensitivity CMOS (complementary metal-oxide semiconductor) camera. And, the correction processors of vignetting, geometrical distortion and scaling were established. Using the developed system, we can measured a percent depth dose, a beam profile and a dose linearity for 6 MV medical LINAC (Linear Accelerator). As results, the optically measured percent depth dose was well matched with the measured percent depth dose by ion-chamber within 2% tolerance. And the determined flatness was 2.8%. We concluded that the optical dosimetry system was sufficient for application of absorbed dose monitoring during radiation therapy.

Generation of 3D City Models Multi-Sensors (다중센서를 이용한 3차원 도시모델의 구축)

  • Choi Kyoung-Ah;Kang Moon-Kwon;Kim Sung-Joon;Lee Im-Pyeong
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2006.05a
    • /
    • pp.106-111
    • /
    • 2006
  • 텔레메틱스, 위치정보서비스, 유비쿼터스 등의 발전과 더불어 3차원 GIS의 활용은 급격히 증가할 것으로 기대된다. 특히 도시모델은 이러한 3D GIS의 근간을 이루며, 이에 도시모델의 획득과 지속적인 수정에 대한 수요 증가도 필연적이다. 따라서 본 연구에서는 기존의 도시모델 구축방법과 달리 보다 효율적이고 정밀한 도시모델을 구축하는 방법을 제시하고 실험적으로 검증하고자 하였다. 제시된 방법은 항공사진과 라이다데이터를 이용하여 지표면모델을 생성하고, 지상사진을 이용하여 건물의 정교한 3차원 모델을 생성하는 것을 핵심으로 한다. 서울시립대학교를 실험대상지역으로 선택하여 전체 23개의 건물을 포함하는 27만 $600m^2$면적의 영역에 대한 도시모델을 구축하였다. 생성된 모델에 대한 검사를 통해 건물과 지표면의 기하학적 구조가 정확하게 재현된 것을 알 수 있었다. 그러나 건물의 외벽 texture는 영상 촬영 시 나무 등에 의해 가려지는 문제, 주변 지물들에 의한 그림자 영향 등으로 깔끔하게 처리되지 못한 것을 볼 수 있었다. 결론적으로 3차원 모델 구축에 있어 texture 추출에 대한 알고리즘 개선이 요구되었고, 건물 내부도 모델링함으로써 더욱 다양한 활용방안도 생각해야 할 것이다.

  • PDF

The Development of Software Program for Depth Electrode though Occipito-temporal Route in Temporal Lobe Epilepsy (내측 측두엽 간질에서 심부전극 삽입을 위한 컴퓨터 프로그램 개발)

  • 이도희;이종주;이정교
    • Progress in Medical Physics
    • /
    • v.13 no.4
    • /
    • pp.234-241
    • /
    • 2002
  • The depth electrode technique, especially using the occipito-temporal route is widely used in the clinic, since it is known to be the most precise method about the invasive study of the mesial temporal lobe epilepsy. The depth electrode with the occipito-temporal route has been applied with manual calculation of MR images. Inherently there are some factor causing significant errors due to geometrical axis alignment, such as miss alignment of horizontal or vertical cutting line. In order to correct it in manually, it takes a long time. In this study, authors has developed the software for automate calculation of MRI wording for instance calculation and for the no time delaying operation. Authors could show that this software is useful for the clinic after applying if for 33 cases of the patients.

  • PDF

Performance Evaluation of KOMPSAT-3 Satellite DSM in Overseas Testbed Area (해외 테스트베드 지역 아리랑 위성 3호 DSM 성능평가)

  • Oh, Kwan-Young;Hwang, Jeong-In;Yoo, Woo-Sun;Lee, Kwang-Jae
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.6_2
    • /
    • pp.1615-1627
    • /
    • 2020
  • The purpose of this study is to compare and analyze the performance of KOMPSAT-3 Digital Surface Model (DSM) made in overseas testbed area. To that end, we collected the KOMPSAT-3 in-track stereo image taken in San Francisco, the U.S. The stereo geometry elements (B/H, converse angle, etc.) of the stereo image taken were all found to be in the stable range. By applying precise sensor modeling using Ground Control Point (GCP) and DSM automatic generation technique, DSM with 1 m resolution was produced. Reference materials for evaluation and calibration are ground points with accuracy within 0.01 m from Compass Data Inc., 1 m resolution Elevation 1-DSM produced by Airbus. The precision sensor modeling accuracy of KOMPSAT-3 was within 0.5 m (RMSE) in horizontal and vertical directions. When the difference map was written between the generated DSM and the reference DSM, the mean and standard deviation were 0.61 m and 5.25 m respectively, but in some areas, they showed a large difference of more than 100 m. These areas appeared mainly in closed areas where high-rise buildings were concentrated. If KOMPSAT-3 tri-stereo images are used and various post-processing techniques are developed, it will be possible to produce DSM with more improved quality.

A Study on the Method for Three-dimensional Geo-positioning Using Heterogeneous Satellite Stereo Images (이종위성 스테레오 영상의 3차원 위치 결정 방법 연구)

  • Jaehoon, Jeong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.33 no.4
    • /
    • pp.325-331
    • /
    • 2015
  • This paper suggests an intersection method to improve the accuracy of three-dimensional position from heterogeneous satellite stereo images, and addresses validation of the suggested method following the experimental results. The three-dimensional position is achieved by determining an intersection point of two rays that have been precisely adjusted through the sensor orientation. In case of conventional homogeneous satellite stereo images, the intersection point is generally determined as a mid-point of the shortest line that links two rays in at least square fashion. In this paper, a refined method, which determines the intersection point upon the ray adjusted at the higher resolution image, was used to improve the positioning accuracy of heterogeneous satellite images. Those heterogeneous satellite stereo pairs were constituted using two KOMPSAT-2 and QuickBird images of covering the same area. Also, the positioning results were visually compared in between the conventional intersection and the refined intersection, while the quantitative analysis was performed. The results demonstrated that the potential of refined intersection improved the positioning accuracy of heterogeneous satellite stereo pairs; especially, with a weak geometry of the heterogeneous satellite stereo, the greater effects on the accuracy improvement.