• Title/Summary/Keyword: 영상유도

Search Result 901, Processing Time 0.029 seconds

A Case Study on 'Visual Affordance' of Short Form Video in Smart Media (스마트미디어 초단편 영상의 '시각 유도성' 사례 연구)

  • Kim, Hyunsook;Moon, Jaecheol
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.7
    • /
    • pp.130-137
    • /
    • 2019
  • With the advent of smart media, short and fast-paced video content appeared, and conditions for viewing changed to viewing in environments where the perception is dispersed due to distracting and complicated external situations in a short period of time. Accordingly, smart media videos are quickly delivering meaning while keeping the eyes of viewers who lack patience. Our eyes and brain have a hard time accepting image information that flows through the constraints of a small screen. Our visual perception is limited in terms of acceptable visual information and, in particular, less cognition in moving images, so the production of smart media images should be directed in a way that enhances perceptual understanding. To be able to effectively communicate what you want to talk about while reducing the visual burden, intuitive image comprehension is needed by applying intuitiveness and behavioral induction to the moving images. Close-up shot, stable structure such as frontality and three-division structure, and color have such 'visual affordance' Therefore we need to use that device appropriately.

Availability of Positron Emission Tomography-Computed Tomography for the Diagnosis of the Soft Tissue Tumor through Ultrasound-Guided Biopsy (초음파 유도하 침 생검을 이용한 연부조직 종양의 진단에 있어 양전자방출 컴퓨터 단층촬영술의 유용성)

  • Jun, Se Bin;Kim, Jeung Il;Lee, In Sook;Song, You Seon;Choi, Kyung Un
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.5
    • /
    • pp.398-403
    • /
    • 2021
  • Purpose: A biopsy is needed to diagnose soft tissue tumors. However, it is extremely difficult to pinpoint the site of a tumor due to the heterogeneity of sarcomas. Thus, even when an open biopsy is conducted, it is difficult to diagnose a soft tissue tumor. In such cases, an ultrasound (US)-guided biopsy is used to improve the diagnostic accuracy. This study evaluated the accuracy of US-guided biopsy for a diagnosis of soft tissue tumors found initially in a magnetic resonance (MR) perfusion and assessed the availability of positron emission tomography-computed tomography (PET-CT) for a diagnosis of soft tissue tumors. Materials and Methods: From January 2014 to December 2018, the US-guided biopsy was performed on 152 patients with a suspected soft tissue tumor found in an MR perfusion and 86 cases were definitively diagnosed with a soft tissue tumor. The accuracy of the US-guided biopsy was assessed retrospectively. Among the 86 cases, only MR perfusion was used before the biopsy in 50 cases, while both MR perfusion and PET-CT was conducted on 36 cases. The accuracy was analyzed to determine if the PET-CT could improve the precision of a biopsy. Results: From 86 cases, 34 out of 50 cases, in which only MR perfusion had been conducted, matched the result of the definitive diagnosis and the US-guided biopsy. 32 out of 36 cases, in which both PET-CT and MR perfusion were conducted, matched the definitive diagnosis and the US-guided biopsy. These results show significant differences in the accuracy of US-guided biopsy. In the case of soft tissue sarcomas, 6 out of 12 cases, in which only MR perfusion had been conducted, matched the result of the definitive diagnosis and the US-guided biopsy. 17 out of 18 cases, in which both PET-CT and MR perfusion were conducted, matched the definitive diagnosis. Moreover US-guided biopsy also showed significant differences in the accuracy of US-guided biopsy. Conclusion: In diagnosing soft tissue tumors, a US-guided biopsy is a well-known tool for its high accuracy. However, the heterogeneity of sarcoma makes it difficult to locate the exact site for a biopsy using only MR perfusion. Thus, the use of PET-CT will meaningfully improve the accuracy of a diagnosis by precisely targeting the site for the US-guided biopsy.

Spectral quality compensation of KOMPSAT-2 fused image by using induction technique (영상 유도 기법을 통한 KOMPSA를-2 융합영상의 분광정보 보정)

  • Choi, Jae-Wan;Kim, Yong-Il
    • Proceedings of the KSRS Conference
    • /
    • 2009.03a
    • /
    • pp.186-189
    • /
    • 2009
  • KOMPSAT-2 고해상도 위성영상이 제공됨에 따라, 국내에서도 고해상도 위성영상을 활용한 다양한 연구 및 활용 사례가 증대되고 있다. KOMPSAT-2는 높은 공간해상도의 흑백영상과 멀티스펙트럴 영상을 동시에 제공하고 있는데, 개체 추출 및 고해상도의 토지 피복도 생성, 영상의 시각화를 위한 고해상도 멀티스펙트럴 영상 취득이 주요한 실정이다. 따라서 서로 다른 공간, 분광해 상도를 가지는 센서 자료를 이용하여 두 개의 장점을 모두 가지는 영상으로 재구성하는 영상융합은 원격탐사분야에서 중요한 연구분야이다. 이를 위해 다양한 영상융합기법이 연구되었지만, 대부분의 알고리즘들이 융합 후에 원 멀티스펙트럴 영상의 분광정보를 왜곡시키는 문제점을 지니고 있다. 본 연구에서는 영상 유도기법을 이용하여 융합영상의 분광정보를 향상시키는 방법을 제안하였다. 원 멀티스펙트럴 영상과 해상도를 낮춘 융합영상과의 비교 분석을 통하여 융합영상의 공간해상도 왜곡은 최소한으로 줄이고 왜곡된 분광정보를 최대한 보정하였다. 다양한 알고리즘을 통해 얻은 KOMPSAT-2 융합 영상에 본 알고리즘을 적용한 결과, 분광정보 왜곡량이 기존의 융합결과에 비해 줄어든 것을 확인할 수 있었으며, 이러한 결과는 다양한 응용분야에 활용될 수 있을 것이다.

  • PDF

The effective quality assurance for image guided device using the AMC G-Box (AMC G-Box를 이용한 영상유도장치의 효율적인 정도관리)

  • Kim, Chong Mi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.199-206
    • /
    • 2014
  • Purpose : According to the rapid increase recently in image-guided radiation therapy, It is necessary to control of the image guidance system completely. In particular for the main subject to the accuracy of image guided radiation therapy device to be done essentially the quality assurance. We made efficient phantom in AMC for the management of the accurate and efficient. Materials and Methods : By setting up of five very important as a quality assurance inventory of the Image guidance system, we made (AMC G-Box) phantom for quality assurance efficient and accurate. Quality assurance list were the Iso-center align, the real measurement, the center align of four direction, the accuracy of table movement and the reproducibility of Hounsfield Unit. The rectangular phantom; acrylic with a thickness of 1 cm to $10cm{\time}10cm{\time}10cm$ was inserted the three materials with different densities respectively for measure the CBCT HU. The phantom was to perform a check of consistency centered by creating a marker that indicates the position of the center fixed. By performing the quality assurance using the phantom of existing, comparing the resulting value to the different resulting value using the AMC G-Box, experiment was analyzed time and problems. Therapy equipment was used Varian device. It was measured twice at 1-week intervals. Results : When implemented quality assurance of an image guidance system using AMC G-Box and a phantom existing has been completed, the quality assurance result is similar in $0.2mm{\pm}0.1$. In the case of the conventional method, it was 45 minutes at 30 minutes. When using AMC G-Box, it takes 20 minutes 15 minutes, and declined to 50% of the time. Conclusion : The consistency and accurate of image guidance system tend to decline using device. Therefore, We need to perform thoroughly on the quality assurance related. It needs to be checked daily to consistency check especially. When using the AMC G-Box, It is possible to enhance the accuracy of the patient care and equipment efficiently performing accurate quality assurance.

A Study on the Implementation of Ultrasonic Guidance Algorithm for Improving Safety of Ultrasonic Varicose Vein Treatment (초음파 하지정맥류 치료의 안전성 개선을 위한 초음파 유도 알고리즘 구현에 관한 연구)

  • Kim, Seong-Cheol;Kim, Ju-Young;Noh, Si-Cheol;Choi, Heung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.435-441
    • /
    • 2018
  • In this study, we performed to design an image guiding algorithm to improve the efficiency and safety of treatment of varicose vein by focused ultrasound. The algorithm was suggested by different guiding images according to the location of varicose veins. In the case of deep-seated varicose veins, the target area was marked on the surface of the blood vessel in the obtained cross-sectional blood vessel ultrasound image. In the case of the superficial varicose vein, A guiding system based on image segmentation algorithm of the vascular region was suggested and designed two different algorithms according to varicose veins progression degree. as a results, the algorithm based on ultrasound image show a small error with $830{\mu}m$ at maximum. However, the algorithm based on charge coupled device image has a maximum error of 8.3 mm in some data. Therefore, it is expected that additional study is needed for superficial varicose vein image guiding algorithm, and it is expected that the accuracy of blood vessel tracking should be evaluated by constructing simple system.

A Study on the expression feature of the visual and auditory senses for Imagery psychotherapy images (심상치료 영상의 시청각적 표현 특성에 관한 연구)

  • Ham, Gi-Hun;Jeong, Seong-Hwan
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2009.05a
    • /
    • pp.47-50
    • /
    • 2009
  • 본 연구는 예술심리치료 및 심상유도의 접근을 통해 영상치료로서의 시각적, 청각적 표현 범위와 치료요소를 찾는데 목적을 두고 있다. 현재 인간의 사회 활동 중에 생기는 정신적 육체적 스트레스를 예방 및 해소하기 위해 이루어지는 치료 활동 중 영상을 이용한 심리치료의 노력이 다방면으로 행해지고 있다. 치료의 형태는 주로 예술심리치료에 속하는 이미지와 기능음악, 클래식 등을 결합한 영상과 음향의 복합적 활용 방식이 주를 이루고 있다. 그러나 이는 치료적 요소에 초점을 두고 체계적인 제작이 되지 앉아 심리치료의 한계를 드러내고 있다. 따라서 본 연구에서는 먼저 기존의 병원, 테라피 공간 및 공공장소에서 일반인을 대상으로 행해지고 있는 영상심리치료의 현황을 파악하고, 행해지는 치료 형태 분류를 통해 색채.미술심리치료에서 사용되어지는 이미지 활용과 음악치료 기법 중 GIM(Guided Imagery and music: 음악과 심상유도) 활용을 중심으로 일반인을 대상으로 하여 실험연구를 진행하였다. 실험 대상물은 영상이미지와 음향의 두 가지 자극이 복합되어 혹은 단일의 자극으로 주어지는 경우를 구분하여 정서적 반응을 조사하고, 전반적인 치료영상에 대한 선호도 조사를 통해 긍정적 정서를 불러일으키는 이미지 및 음향 요소를 도출한다. 이는 향후 영상심리치료의 체계적인 가이드라인 제작과 평가 척도 개발을 위한 기초 자료로 활용할 수 있다.

  • PDF

Study of Integrated-Flight M&S Application for the Anti-Tank Missile Configuration Design (대전차 유도무기의 형상 설계에서의 통합비행 M&S 적용 연구)

  • Jeong, Dong Gil;Kim, Sangman;Lee, Gunha;Hwang, Cheol Gyu
    • Journal of the Korea Society for Simulation
    • /
    • v.26 no.1
    • /
    • pp.13-19
    • /
    • 2017
  • 6-DOF flight simulation program is most generally used M&S tool in domestic missile development procedure. The 6-DOF M&S method, however, cannot validate the performance of a imaging seeker-adopted missile in various conditions. A M&S tool for the analysis of the integrated-flight simulation is required since the tracking performance of the imaging seeker is highly dependent on the missile maneuvering, which introduces the displacement and rotation of the target in the seeker imagery. Through the development of the $3^{rd}$ generation anti-tank missile, Raybolt, the integrated-flight M&S tool was developed and applied to the missile configuration design. It integrates synthetic image generation S/W, imaging tracker, and flight simulation program and computes the main system performance criteria, hit probability by Monte-Carlo Simulation. In this paper, the issues in the $3^{rd}$ generation anti-tank missile configuration and the integrated-flight M&S method and results are described.

Guided Wave Tomographic Imaging Using Boundary Element Method (경계요소법을 이용한 유도초음파 토모그래피 영상화 기법)

  • Piao, Yunri;Cho, Youn-Ho;Jin, Lianji;Ahn, Bong-Young;Kim, Noh-Yu;Cho, Seung-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.338-343
    • /
    • 2009
  • Tomography is the imaging method of cross sectional area using multi beam signals and is mainly applied to the medical diagnosis to acquire the image of the inside human body. This method is pretty meaningful in nondestructive evaluation field since the imaging of the inspection region can enhance the comprehension of the inspector. Recently, much attention has been paid to the guided wave for the diagnosis of platelike structures. So, in this work, a study on the imaging of the damage location in a plate was carried out on the basis of computer aided analysis of guided waves and tomographic imaging. To this end, boundary element method was employed to analyze the effect of the damage in plate on the propagation of the guided waves and the analytic results were applied to the tomographic imaging method to identify the damage location. Consequently, it was shown that the number of sensors heavily affect the inspection performance of the damage location.

Distortion Analysis in Stereoscopic Images (스테레오 영상에서의 상의 왜곡 해석)

  • ;Y. Gruts
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.198-199
    • /
    • 2001
  • 본 논문은 스테레오 영상의 왜곡 현상을 분석하는 수학적인 해석 방법을 제안하였다. 스테레오 카메라의 중심과 투사기의 중심을 연결하는 직선이 스크린이 가지는 평면의 중심을 지나는 법선 벡터가 되고, 스테레오 카메라와 투사기의 두 렌즈의 광축이 스크린의 중심에 놓일 경우에 사진을 찍는 조건, 투영 조건 및 관측 조건에 해당하는 해석해를 유도하였다. 위 세 가지 조건에 따라 영상의 왜곡 정도가 바뀌게 되는데 왜곡을 최소한으로 만들 수 있는 조건식을 유도하였다.

  • PDF