• Title/Summary/Keyword: 염화동

Search Result 68, Processing Time 0.021 seconds

A Study on the Recovery of Shape-controlled Copper Oxide from the Waste etchant of PCB Industry (PCB 産業에서 배출되는 산성 염화동 폐액으로부터 입자형상이 제어된 산화동 회수에 관한 연구)

  • 김영희;류도형;김수룡;어용선
    • Resources Recycling
    • /
    • v.10 no.6
    • /
    • pp.15-21
    • /
    • 2001
  • Shape-controlled copper oxides have been recovered from copper-containing waste etchant by neutralization with alkalihydroxide. Large amount of copper-containing waste etchant is generated from Printed Circuit Board industry. In an environmental and economic point of view, retrieve of the valuable natural resource from the waste is important. In recycling process of copper oxide from the waste etchant, reaction temperature controls shapes and sizes of the products. Copper oxide recovered below reaction temperature $40^{\circ}C$ was of a needle shape, while copper oxide comes in a platy shape above $40 ^{\circ}C$ . Physical properties of samples have been characterized using SEM, XRD, TGA and Atomic absorption spectroscopy.

  • PDF

A Stydy on the Preparation of Cu-Graphite Composite Powders (흑연-금속동 복합분말제조에 관한 연구)

  • Oh, Jong-Kee;Kim, Taek-Hoon;Lee, Hwa-Yeong
    • Korean Journal of Materials Research
    • /
    • v.3 no.2
    • /
    • pp.103-110
    • /
    • 1993
  • Abstract It has been attempted to make the copper-graphite composites by deposition of copper on the surface of graphite through the hydrogen reduction of copper chlorides. Both KISH and natural graphites of less than 325 mesh were used as substrates and the hydrogen reduction also was conducted in the range of 350-50$0^{\circ}C$. The distribution of copper on the surface of graphite was found to increase with the decrease of reduction temperature. In addition. the partial pressure of hydrogen played an important role in the overall rate of reduction which was substantially dominated by the chemical reaction on the surface of each particle. It was concluded that the reduction temperature should be maintained as low as possible to accomplish the well distribution of copper in the composites.

  • PDF

Preparation and Characterization of Copper Oxychloride from Acidic Copper Chloride Etchant (PCB 산업에서 배출되는 산성 염화동 폐액으로부터 Copper Oxychloride의 제조 및 특성분석)

  • 김영희;김수룡;정상진;이윤주;어영선
    • Resources Recycling
    • /
    • v.12 no.2
    • /
    • pp.3-10
    • /
    • 2003
  • Copper oxychloride used as an agricultural fungicide has been recovered from copper-containing waste etchant by the neutralization with alkali hydroxides. Large amount of copper-containing waste etchant is generated from Printed Circuit Board industry. In an environmental and economic point of view, retrieve of the valuable natural resource from the waste is important. Recycling process of copper oxychloride from the waste etchant is discovered through the our study. In the range of reaction temp. 2$0^{\circ}C$-4$0^{\circ}C$, pH 5-7, pure copper oxychloride was able to prepare and the yield of copper oxychloride was higher than 95%. Physical properties of the sample have been characterized using SEM, XRD, TGA, ICP and Atomic absorption spectroscopy.

Etching properties of BeCu Foil using $FeCl_3$ solution (염화제이철 용액을 이용한 베릴륨동 기판의 식각 특성)

  • Lee, Keun-Woo;Lee, Byung-Wook;Lee, Tae-Sung;Lee, Jong-Ha;Lee, Jae-Hong;Kim, Chang-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.26-27
    • /
    • 2006
  • 구리와 강철의 성질을 혼합한 것과 같은 우수한 성질을 갖고 있어서 열전도율이 좋고 내마모성이 뛰어난 베릴륨동 기판(BeCu foil)에 대한 식각 특성에 관하여 연구하였다. 일반적으로 베결륨구리에 대한 식각용액은 염화제이철($FeCl_3$)이 널리 알려져 있으며, 이 용액은 농도와 온도에 따라 식각시간이 달라지게 되어 식각되는 면의 상태가 영향을 받게 된다. 염화제이철의 농도를 변화시켜 본 결과 염화제이철의 농도가 증가할수록 식각률이 증가하였고, 염화제이철에 염산(HCI)을 첨가한 결과 식각률이 증가함을 알 수 있었다. 이는 염화제이철의 성분 중에서 염산(HCl)의 농도가 식각률에 영향을 미치고 있음을 나타낸다. 또한 염화제이철의 온도가 $40^{\circ}C$일때 식각률이 가장 우수하며 식각되는 면의 상태가 매우 양호해지고 각각 되는 면의 각도도 수직에 가까워진다.

  • PDF

A Study on The Corrosion Resistance of Concrete Containing Copper Slag (동제련 슬래그 혼입 콘크리트의 부식 저항성에 관한 연구)

  • Lee, Dong-Un;Jung, Yoo-Jin;Kim, Young-Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.5
    • /
    • pp.189-196
    • /
    • 2007
  • The purpose of this study was to analyze steel corrosion resistance of concrete containing copper slag. The specimens were made with normal portland cement and pozzolan materials with various replacement ratio and with W/B ratio ranging from 35% to 55%. Compressive strength, coefficient of chloride diffusion, corrosion area ratio and weight reduction ratio were determinated for the test. The results show that the concrete with pozzolan materials is superior resistant to chloride ions compared to the concrete without pozzolan materials. It was observed that blast furnace slag replacement ratio of 20% gives the best results with respect to chloride ion penetration and corrosion tests and observed that copper slag replacement ratio of 10% gives the seperior resistance compared to normal concrete.

Evaluation of the Properties of an Environment-Friendly De-icing Agent Based on Industrial By-Products (산업부산물을 활용한 친환경제설제의 특성평가)

  • Heo, Hyung-Seok;Lee, Byung-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.132-139
    • /
    • 2017
  • A huge amount of de-icing agent is sprayed during winter to promote traffic safety in cold regions, and the quantity of de-icing agent sprayed has increased each year. The main ingredients in commonly used de-icing agents are chlorides, such as calcium chloride($CaCl_2$) and sodium chloride(NaCl). While calcium chloride is mostly used in Korea and sodium chloride is usually used in the U.S. and Japan, all de-icing agents include chloride ions. The chlorides included in sprayed calcium chloride-based de-icing agents have severe adverse effects, including the corrosion of reinforcing steels through salt damage by infiltrating into road structures, reduced structural performance of pavement or damage to bridge structures, and surface scaling, in combination with freezing damage in winter, as well as water pollution. In addition, the deterioration of paved concrete road surface that occurs after the use of calcium chloride-based de-icing agent accelerates the development of visual problems with traffic structures. Therefore, the present study was performed to prepare an environment-friendly liquid de-icing agent through a reaction between waste organic acids and calcium-based by-products, which are industrial by-products, and to analyze the properties of the de-icing agent in order to evaluate its applicability to road facilities.

Durability of High-fluidity Polymer-Modified Mortar Using Redispersible Polymer Powder (재유화형 분말수지 혼입 고유동 폴리머 시멘트 모르타르의 내구성)

  • Joo Myung-Ki;Lee Youn-Su;Youn Do-Yong;Jung In-Su
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.703-708
    • /
    • 2005
  • The effects of polymer-cement ratio and antifoamer content on the setting time and durability of high-fluidity polymer-modified mortars using redispersible polymer powder are examined. As the result, the setting time of the polymer-modified mortars using redispersible polymer powder tends to be delayed with increasing polymer-cement ratio, regardless of the antifoamer content. The water absorption, chloride ion penetration depth and carbonation depth of the high-fluidity polymer-modified mortars using redispersible polymer powder decrease with increasing polymer-cement ratio and antifoamer content. The resistance of freezing and thawing and chemicals improvement is attributed to the improved bond between cement hydrates and aggregates because of the incorporation of redispersible polymer powder

Exothermic Oil Absorbent Sheet for Low-sulfur Fuel Oil (LSFO) Spilled into Seawater in the Winter Season (동절기 해상으로 유출된 저유황 중질유 제거를 위한 발열 흡착포)

  • Park, Han-gyu;Oh, Gyung-geun;Bae, Byung-Uk;Song, Young-Chae
    • Journal of Navigation and Port Research
    • /
    • v.46 no.4
    • /
    • pp.297-302
    • /
    • 2022
  • An exothermic oil absorbent sheet with calcium chloride crystals can be fabricated, by dipping a clean polypropylene fabric in calcium carbonate and hydrochloric acid solution and drying it. The exothermic oil absorbent sheet applied to the seawater surface, releases heat by the dissociation of calcium chloride. The dissociation heat liquefies the solidified low-sulfur fuel oil at a low temperature, and converts it to a state at which it can be absorbed. The optimum mole concentrations of calcium carbonate and hydrochloric acid required for the exothermic oil absorbent sheet, are 0.25 M and 0.5 M, respectively. The oil absorption capacity of the exothermic oil absorbent sheet for low sulfur fuel oil depends on the seawater temperature. But, it is highly excellent at 4.5-7.08 g/g at 10℃, the average seawater temperature during the winter in Korea. The exothermic oil absorbent sheet is an excellent alternative in absorbing low-sulfur fuel oil in winter and removing it from seawater.

Kinetic Studies on Nucleophilic Substitution Reaction for Naphthalene Carbonyl Chloride (염화나프탈렌카르보닐의 친핵성 치환반응에 관한 연구)

  • Sang Kee Yoon;Tae Sup Uhm;Dae Dong Sung
    • Journal of the Korean Chemical Society
    • /
    • v.24 no.5
    • /
    • pp.347-355
    • /
    • 1980
  • The rate constants for the reaction of ${\alpha}$-naphthalene carbonyl chloride and ${\beta}$-naphthalene carbonyl chloride have been determined in methanol-acetonitrile and methanol-acetone. The rate constant of ${\alpha}$-naphtalene carbonyl chloride is higher than that of ${\beta}$-naphthalene carbonyl chloride. This behavior is consistent with Dewar's number, Nr and also Streitwieser's value ${\sigma}^+$. Since in the transition state carbonyl carbon is transformed to$sp^3$, no peri-hydrogen effect was observed.

  • PDF

Study on the Preparation of Copper Sulfate by Copper Powder using Cation Membrane Electrowinning Prepared from Waste Cupric Chloride Solution (염화동 폐액으로부터 양이온격막 전해 채취된 구리 분말을 이용한 황산동의 제조방법 연구)

  • Kang, Yong-Ho;Hyun, Soong-Keun
    • Resources Recycling
    • /
    • v.28 no.1
    • /
    • pp.62-72
    • /
    • 2019
  • Generally, $H_2SO_4$ and Cu metal are used as raw materials for producing copper sulfate. The study relates to a method for producing copper sulfate using electrowinning from a waste solution of copper chloride. Uses are used for copper plating for industry, plating, feed, agriculture, electronic grade PCB. Conventional methods for producing copper sulfate have a problem of a large amount of waste water and a high energy cost. A study on the production method of copper sulfate ($CuSO_4$), which is the most used among copper (Cu) compounds, has a low process operation ratio, a small amount of waste water, and a simple manufacturing process. It is easy to remove Na, Ca, Mg, and Al as impurities by using a cationic membrane. At the same time, high purity copper powder could be recovered by an electrowinninng method. Using the recovered copper powder, high purity copper sulfate could be produced.