• Title/Summary/Keyword: 열 복사열

Search Result 730, Processing Time 0.027 seconds

Design of the helical array antenna for the domestic broadcast satellite (국내 위성방송 수신용 헬리컬 어레이 안테나의 설계)

  • 맹성옥;최학근
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.8
    • /
    • pp.1747-1754
    • /
    • 1997
  • The helical array antenna is designed for domestic DBS(Directcast Satellite) reception. The antenna diameter is determined 30cm with 168 element s to cover from Moojoo (beam center) to Seoul. The helical antenna with 2-turns and 4.deg. pitch angle is chosen as array elements for good axial ratio and antenna height. In array antenna design, row distance is 0.787.lambda., array distance is 0.824.lambda. in the same row. The feed is constructed using the radial waveguide to decrease the height of antenna. The measured values of the designed antenna are not only satisfied with the design goals but also similar to theoritical values except the axial ratio.

  • PDF

A Study on Light-weight Signature Scheme for NFC mCoupon Service (NFC mCoupon 서비스를 위한 경량화 서명 기법에 관한 연구)

  • Park, Sung-Wook;Lee, Im-Yeong
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.24 no.2
    • /
    • pp.275-284
    • /
    • 2014
  • Recently, the combination of mobile and NFC aroused great momentum for Activation of NFC services market. Especially, mCoupon service using NFC has been utilized in a variety consumer marketing. However, mCoupons differ significantly from paper-based coupons because unprotected data can be easily copied or modified without significant cost by anyone. A high number of uncontrolled copies of coupons can result in a significant loss. In this paper, we proposed a light-weight signature scheme that is protected against illegal use in nfc mobile payment environment to using limited resources.

Jet Entrainment Effect in Buoyant Jet and Iso-Thermal Fire Modeling (부력제트의 주위공기 유입효과 및 등온기체 모델링)

  • Lee, Eui-Ju
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.111-115
    • /
    • 2009
  • Acetone LIF and Rayleigh scattering measurements were performed to identify the entrainment of ambient air in the buoyant jet qualitatively. The air entrainment near nozzle exit was enhanced with increasing both an axial distance and Reynolds number. The results supported that the air entrainment had to be considered in isothermal model for the development of its accuracy. Also, this paper provided an isothermal model based on the ideal plume, of which radiative heat loss fraction was assumed to 0.35 and the entainment of isothermal jet was considered. This simple model could be used in compartment or semi-enclosure fires such as tunnel, and it is more reliable because of introducing entrainment effect in isothermal jet.

A Study on the LRE Thrust Chamber Regenerative Cooling Design (액체로켓엔진 추력실의 재생냉각 기관 설계)

  • Kim, Ji-Hoon;Park, Hee-Ho;Kim, Yoo;Hwang, Soo-Kwon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.6 no.4
    • /
    • pp.25-35
    • /
    • 2002
  • A calculation procedure for designing LRE regenerative cooling system is introduced. In LRE thrust chamber, heat is transfered from the hot gas to the wall by convection and radiation, then conduction through the wall and finally convection to the liquid coolant. A cooling channel is designed on the basis of heat transfer rate calculated by using criterial method and integral method. The result is compared with existing Russian cooling channel design code. Also a design logic and quantitative effect of various parameters were introduced to help better understanding for those who is not familiar to LRE system.

A Linear Stability Analysis of Unsteady Combustion of Solid Propellants (고체추진제 비-정상연소의 선형 안정성해석)

  • 이창진;김성인;변영환
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.2 no.1
    • /
    • pp.59-66
    • /
    • 1998
  • The combustion instability analysis of solid propellants is generally done by the simplified governing equations for chemically inert condensed phase region with QSHOD assumption. Since the gas phase and surface reaction layer can be more rapidly relaxed to the external perturbations than the condensed phase, these regions are treated as quasi-steady manner in the analysis. In this paper, the classical ZN(Zeldovic-Novozhilov)approach was re-examined with the presence of radiation augmented burning enhancement in the combustion. Also, the surface reaction was assumed to partially absorb the incident radiant heat fluxes and pass the remaining to the chemically inert condensed phase. As a result of the analysis, the burning rate response function was obtained which consists of a pressure response function and a radiation response function. The response function was shown to be able to predict the results of T-burner tests.

  • PDF

Measurements of Transmittances and Calculations of Fundamental Radiative Properties (투과율의 측정 및 이를 이용한 복사물성치의 계산)

  • Hwang, Yong-Ha;Park, Seung-Ho;Lee, Young-Soo
    • Solar Energy
    • /
    • v.14 no.2
    • /
    • pp.29-37
    • /
    • 1994
  • Radiative charaacteristics of glass windows and porous absorbing media which can be used for a solar air heater are determined through the measurements of spectral transmittances. Those in the visible range are measured by the UV-IR spectrometer. Refractive index of glass are obtained by the comparison of the measured transmittances and the correlations derived from the electromagnetic theory and are compared to the theoretical ones calculated from the classical dispersion theory. Absorption and back-scattering coefficients of 15-mesh stainless wire screens are calcuated by the comparison of the measured transmittances and the correlations derived from the two flux model.

  • PDF

Effect of Radiation on Laminar Film Boiling of Binary Mixtures (2성분 혼합물질의 층류 막비등에서 복사열전달의 효과)

  • Seong Hyeon-Chan;Kim Kyoung-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.942-951
    • /
    • 2004
  • This paper presents the results of a theoretical study of the effect of radiation during free convective laminar film boiling for methanol/water binary mixtures on an isothermal vertical wall at atmospheric pressure. With the well-known boundary layer theory as a basis, a theoretical model has been formulated into consideration for mass diffusion at liquid phase. The equations are numerically solved by a similarity method to investigate the effects of radiation emissivity on the surface with various parameters such as wall superheat and composition of more volatile component at liquid phase far from the wall. From the results, the distributions of the physical quantifies are investigated in both phases. New correlations are proposed to predict the heat transfer coefficient of binary mixtures. It is shown that the proposed correlations are in good agreement with numerical results and with Bromley's correlation within maximum $11\%$ errors. It is also found that as the wall superheat is increased, radiation effect becomes more important.

Study on the Multi-Zone Furnace Analysis Method for Power Plant Boiler (발전용 보일러에 대한 다중영역분할 화로해석 기법의 활용성 연구)

  • Baek, SeHyun;kim, Donggyu;Lee, Jang Ho
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.427-432
    • /
    • 2020
  • In this study, a multi-zone furnace analysis method that couples a 1D energy and mass balance calculation with a 3D radiative heat transfer calculation is tested in order to verify its reliability. The calculated results for a domestic 500 MW capacity coal-fired boiler furnace were compared with the design data of the boiler manufacturer and CFD analysis, and a good agreement was achieved. Although this calculation method is less sophisticated than the CFD furnace analysis, it has an advantage in terms of calculation time while being able to provide the furnace behavior according to the fuel characteristics and operational variable changes. Therefore, it is expected to be useful for boiler operation diagnosis and daily fuel/operation planning.

Design of the Condenser and Automation of a Solar Powered Water Pump (태양열 물펌프의 운전 자동화 설계)

  • Kim Y. B.;Son J. G.;Lee S. K.;Kim S. T.;Lee Y. K.
    • Journal of Animal Environmental Science
    • /
    • v.10 no.3
    • /
    • pp.141-154
    • /
    • 2004
  • The solar powered water pump is very ideal equipment because solar power is more intensive when the water is more needed in summer and it is very helpful in the rural area, in which the electrical power is not available. The average so]ar radiation energy is 3.488 kWh/($m^2{\cdot}day$) in Korea. In this study, the automatic control logic and system of the water pump driven by the radiation energy were studied, designed, assembled, tested and analyzed for realizing the solar powered water pump. The experimental system was operated automatically and the cycle was continued. The average quantity of the water pumped per cycle was about 5,320 cc. The cycle time was about 4.9 minutes. The thermal efficiency of the system was about $0.030\%$. The pressure level of the n-pentane vapour in flash tank was 150$\%$450 hPa(gauge) which was set by the computer program for the control of the vapour supply. The pressure in the condenser and air tank during cycles was maintained as about 600 hPa and 1,200 hPa respectively. The water could be pumped by the amount of 128kg/($m^2{\cdot}day$) with the efficiency of $0.1\%$ and the pumping head of 10 m for the average solar energy in Korea.

  • PDF

The Comparison of the Solar Radiation and the Mean Radiant Temperature (MRT) under the Shade of Landscaping Trees in Summertime (하절기 조경용 녹음수 수관 하부의 일사와 평균복사온도 비교)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.5
    • /
    • pp.22-30
    • /
    • 2014
  • The purpose of this study was to compare the Solar Radiation(SR) and the Mean Radiant Temperature(MRT) under the shades of the three landscaping trees in clear summer daytimes. The trees were Lagerstroemia indica, Quercus palustris and Ulmus parvifolia. The solar radiation, the globe temperature and the air temperature were recorded every minute from the $1^{st}$ of April to the $30^{th}$ of September 2013 at a height of 1.1m above on the four monitoring stations, with four same measuring system consisting of a solar radiation sensor, two resistance temperature detectors(Pt-100), a black brass globe (${\phi}50mm$) and data acquisition systems. At the same time, the sky view photos were taken automatically hourly by three scouting cameras(lens angle: $60^{\circ}$) fixed at each monitoring station. Based on the 258 daily sky view photos and 6,640 records of middays(10 A.M.~2 P.M.) from the $1^{st}$ of June to the $30^{th}$ of August, the time serial differences of SR and MRT under the trees were analysed and compared with those of open sky, The major findings were as follows; 1. The average ratio of sky views screened by the canopies of Quercus palustris, Lagerstroemia indica and Ulmus parvifolia were 99%, 98% and 97%, and the SR were $106W/m^2$, $163W/m^2$ and $202W/m^2$ respectively, while the SR of open sky was $823W/m^2$. Which shows the canopies blocked at least 70% of natural SR. 2. The average MRT under the canopies of Quercus palustris, Lagerstroemia indica and Ulmus parvifolia were $30.34^{\circ}C$, $33.34^{\circ}C$ and $34.77^{\circ}C$ respectively, while that of open sky was $46.0^{\circ}C$. Therefore, it can be said that the tree canopies can reduce the MRT around $10{\sim}16^{\circ}C$. 3. The regression test showed significant linear relationship between the SR and MRT. In summary, the performances of the landscaping shade trees were very good at screening the SR and reducing the MRT at the outdoor of summer middays. Therefore, it can be apparently said that the more shade trees or forest at the outdoor, the more effective in conditioning the outdoor space reducing the MRT and the useless SR for human activities in summertime.