• 제목/요약/키워드: 열 복사열

Search Result 728, Processing Time 0.023 seconds

Temperature Prediction for the Wastewater Treatment Process using Heat Transfer Model (열전달 모델을 이용한 폐수처리공정의 온도 예측)

  • Rho, Seung-Baik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1795-1800
    • /
    • 2014
  • The temperature change in the biologically activated sludge wastewater treatment process was predicted using the heat transfer model. All incoming and outgoing heats in wastewater treatment processes were considered. Incoming heats included the solar radiation heat, the heat from impeller mechanical energy, and the biochemical heat in the aeration process. Outgoing heats comprised the radiation heat from the waste itself, the heat of vaporization and surface aeration, the wind convection heat and the conduction heat between the surface and aerator. All heats were used as an input to the existing empirical heat transfer model. The heat transfer model of wastewater treatment processes is presented also. To test the validity of the heat transfer model, the operating conditions of the actual wastewater treatment plant were used. The temperatures were compared with the model temperatures. Model predictions were consistent within the $1.0^{\circ}C$.

Experimental Analysis of Thermal Comfort for Ceiling and Floor Supply Air-conditioning Systems (냉방시 천장분출 및 바닥분출 공조방식에 따른 열환경 평가실험)

  • Cho, Yong;Kwon, Hurk-Seung;Kim, Sung-Hyun;Kim, Yong-Il
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1998.11a
    • /
    • pp.133-139
    • /
    • 1998
  • 생활수준이 향상됨에 따라 인간의 감성을 생활환경에 적용하려는 연구가 진행되고 있다. 감성에 영향을 미치는 요인은 다양하나 이 중에서도 열환경은 인간에게 미치는 정도가 어떠한 요인보다도 큰 것으로 알려져 있다. 열환경이라 함은 온도, 습도, 기류, 복사열을 말하며 이 요소들은 인간의 감성과 밀접한 관련을 지닌다. 실내의 열환경은 공조방식에 따라 크게 달라지며 본 연구에서는 천장분출과 바닥분출 공조방식의 비교실험을 수행하여 실내의 열환경을 평가한다. 두 공조방식을 여름철 사무실 공간을 모사하는 열환경챔버에 적용하여 실내의 온도, 기류, 복사온도, PMV의 분포를 측정한다. 실험 결과 바닥분출 공조방식이 쾌적성과 에너지 절약면에서 우수함을 알 수 있었다.

  • PDF

Analysis of Thermal Comfort for Ceiling and Floor Supply Air-conditioning System (냉방시 천장분출 및 바닥분출 공조방식에 따른 열환경 평가)

  • 이기섭;김영일
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1998.04a
    • /
    • pp.249-254
    • /
    • 1998
  • 생활수준이 향상됨에 따라 인간의 감성을 생활환경에 적용하려는 연구가 진행되고 있다. 감성에 영향을 미치는 요인은 다양하나 이 중에서도 열환경은 인간에게 미치는 정도가 어떠한 요인보다도 큰 것으로 알려져있다. 열환경이라 함은 온도, 습도, 기류, 복사열을 말하며 이 요소들은 인간의 감성과 밀접한 관련을 지닌다. 실내의 열환경은 공조방식에 따라 크게 달라지며 본 연구에서는 천장분출과 바닥분출 공조방식에 따른 실내의 열환경을 평가한다. 두 공조방식을 여름철 사무실 공간에 적용하여 실내의 온도, 기류, 복사온도, PMV의 분포를 수치해석적으로 계산한다. 해석 결과 바닥분출 공조방식이 쾌적성과 에너지 절약면에서 우수함을 알 수 있었다.

  • PDF

Analysis on the Explosion Risk Characteristic of Hydrogen blended Natural Gas (HCNG 혼합연료의 폭발 위험 특성 분석)

  • Kang, Seung-Kyu;Kim, Young-Gu;Kwon, Jeong-Rak
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.223-229
    • /
    • 2014
  • This study investigated the explosion characteristics of HCNG fuel using a simulation tool. The damage caused by the storage container explosion and vapor cloud explosion in a gas station was predicted. In case of an vapor cloud explosion in the HCNG station, 50~200kPa explosion pressure was predicted inside the station. When the cylinder explosion was occurred, in case of hydrogen, the measured influential distance of overpressure was 59m and radiant heat was 75m. In case of CNG, influential distance of overpressure was 89m and radiant heat was 144m would be estimated. In case of 30% HCNG that was blended with hydrogen and CNG, influential distance of overpressure was 81m and radiant heat was 130m were measured. The damage distance that explosive overpressure and radiant heat influenced CNG was seen as the highest. HCNG that was placed between CNG and hydrogen tended to be seen as more similar with CNG.

A study on the room heating by solar assisted heat pump using the alternatives (대체냉매적용 태양열 열펌프시스템에 의한 난방성능분석(1))

  • 선경호;정현채
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.94-99
    • /
    • 1995
  • 본 연구는 태양열 열펌프시스템에 의한 약 6평 규모의 실내의 난방방법으로서 간접 난방인 온수순환난방과 직접난방인 복사난방의 성능을 분석하였다. 태양열 열펌프의 최대의 열적성능을 나타낼 수 있도록 알루미늄 롤 본드형 태양열 집열기의 면적을 조절하였으며 집열효과를 극대화하기 위하여 온도감응 자동팽창밸브의 용량을 변화시켰다. 본 실험에서 적용된 태양열 열펌프 난방은 서울지방 봄 가을철의 외기온도에서 실내온도가 18~2$0^{\circ}C$로 유지되도록 설계제작되었다. 태양열 열펌프시스템에 적용된 작용유체는 온수순환 난방에는 R-12냉매. 그 대체냉매는 R-134a 및 혼합냉매, 복사난방에는 R-22냉매이었다.

  • PDF

Study on the Thermal Characteristics of the Fire Fighter's Waterproof Clothing Exposed to the Radiation Heat (복사열에 노출된 소방용 방수복의 열적 특성에 관한 연구)

  • 방창훈
    • Fire Science and Engineering
    • /
    • v.17 no.1
    • /
    • pp.21-25
    • /
    • 2003
  • This experimental study shows the thermal characteristics of the fire fighter's waterproof clothing exposed to the radiation heat. From the test results, the surface temperature of the fire fighter's waterproof clothing exposed to the radiation with the passage of time sharply increased as the exposed-distance became closer. Also as the radiant heat flux increased, the surface temperature is higher and the time reaching steady state is sharply shorter. As the exposed-distance become more distant, the surface temperature of the fire fighter's waterproof clothing decreased and the difference of temperature between the front side and the back side of the clothing decreased as well. Besides, the radiant heat flux increased, the safety exposed-distance increased. Therefore it is necessary that fire fighter have to work keeping a fixed safe distance from the radiant heat source.

A Combustion Characteristic Analysis of Sandwich Panel Core Using Radiation Heat Flux (복사열을 이용한 샌드위치 패널 심재의 연소특성 분석)

  • Park, Hyung-Ju
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.25-31
    • /
    • 2007
  • The combustion characteristics and combustion heat of sandwich panel cores were analysed using variable external irradiation level. The characteristics such as ignition time, critical heat flux, ignition temperature and surface temperature profile were measured. Fuel samples were exposed to incident heat fluxes from 15 to $50\;kW/m^2$. For the measurement of various combustion characteristics, the size of specimen was $100\;mm\;{\times}\;100\;mm\;{\times}\;50\;mm$ and the samples were 3 different kinds. As results, Type B showed the best characteristics in measurement of combustion heat and ignition temperature and Type C showd the best characteristics in critical heat flux and surface temperature profile than that of the other two. In conclusion, we knew that Type C had the best performance in fire safety from all data of this study.

보일러 화로내 3차원 복사열전달의 공학적 해석

  • 이진욱;마수만;임동렬
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.150-156
    • /
    • 1995
  • 보일러 화로내의 3차원 복사열전달 현상을 비교적 간단하게 수행할 수 있는 프로그램을 개발하여 중유를 연료로 사용하는 산업용 보일러의 화로해석을 수행하였다. 프로그램 개발시에는, 공학적으로 수용이 가능한 범위내에서의 경험값 및 가정을 도입하여 화로내에서 존재하는 현상들을 해석하기 위한 연립편미분방정식을 가능한 분리(decoupling)시켜 3차원 복사열전달 현상을 비교적 간단하게 수행할 수 있게 하였으며, 특히 보일러 제조업체의 설계부서에서 직접 화로해석을 수행하고 그 결과를 기본설계에 반영할 수 있게 시도하였다. 실제 보일러의 화로에 대한 설계자료를 이용하여 화로해석을 수행하였으며, 그 결과의 신뢰성을 입증하였다.

  • PDF

High Fidelity Calculation of Thermal Load in a Satellite Orbit (고정확도의 인공위성 궤도 열하중 계산 기법)

  • Kim, Min-Ki
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.10
    • /
    • pp.898-906
    • /
    • 2017
  • This paper discusses the efficient high fidelity calculation of external thermal loads of a spacecraft on its orbit. Thermal loads to a spacecraft consist of three major components, direct solar radiation, earth reflection of solar rays, and earth irradiation. With the assumption that both earth reflection and earth emission are diffuse, thermal loads from earth surface divided into pieces of segments to satellite surfaces are individually calculated and summed over. By using analytical integration of both reflected and emitted heat load by earth, high rate of numerical convergence is achieved and the results are even exactly calculated in special cases. Moreover, KD tree ray tracing is employed in the calculation of thermal load to determine whether the radiated ray is obstructed or not by satellite structure.

대형 콘 칼로리미터의 신뢰성 구축을 위한 발열량 측정 결과 분석

  • Yu, U-Jun;Kim, Chang-Seop;Jeon, Gwang-Hun;Yeom, Mun-Cheon;SaGong, Seong-Ho;Kim, Jeong-Yong;Kim, Seong-Chan;Yu, Hong-Seon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.49-49
    • /
    • 2013
  • 실규모급 화재 실험의 신뢰성 있는 발열량 측정을 위해서 흡입 배관의 직경 1.6 m, 직선길이 26m, 후드 직경 10 m 그리고 흡입용량 $2,000m^3/min$ 이상의 대형 콘 칼로리미터를 구성하여 헵탄의 화재 크기별 연소 실험을 진행하였다. 발열량 측정을 비교 분석하기 위해서 산소 소모 지수법, 질량 소모법, 복사열 그리고 대류열 측정 기법에 따라서 각각의 발열량을 산출하고 크기를 비교하였다. 그 결과 대형 콘 칼로리미터에 의해서 측정한 산소 소모 지수법은 이론 발열량에 해당하는 질량 소모법과 최대 약 2.3 % 정도, 복사열에 의한 발열량 산출법은 12.2 % 정도, 연소면적에 의한 이상적인 발열량과는 최대 30 % 정도, 그리고 대류열만 고려한 경우 약 50 % 정도 차이가 나는 것을 확인하였다.

  • PDF