• Title/Summary/Keyword: 열 교환기

Search Result 247, Processing Time 0.031 seconds

Study on Heat Recovery System using Waste Biomass (폐 바이오매스를 이용한 폐열 회수 열교환기에 관한 연구)

  • Lee Chung-Gu;Lee Se-Kyoun;Lee Kye-Bock;Rhi Seok-ho;Ryou In-Seon
    • Journal of Energy Engineering
    • /
    • v.14 no.4 s.44
    • /
    • pp.248-258
    • /
    • 2005
  • In the present study, in order to estimate possibility as a waste heat recovery system, three different heat exchangers are developed. The developed heat exchangers are tile system to supply the hot water using fermentation of waste biomass. For the experiments, various biomass materials were examined to obtain the best heat recovery. Waste heat recovery system was studied numerically and experimentally. Heat exchanger system was designed specially to obtain the optimum heat exchanging performance. The biomass heat exchanger was operated for 20 minutes, after 1 hour from start-up, the temperature of the biomass dump has been raised to the possible operation temperature. From the three time operations per day, the system would be able to supply the amount of energy, about 62,400 kcal/day.

A Development of Heater utilizing Heat from Communication Equipment (통신기기열 활용 난방기 개발)

  • Kang, Wang-Kyu;Park, Tae-Dong
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.482-485
    • /
    • 2008
  • 통신기기실은 겨울철에도 냉방이 이루어질 만큼 열이 많이 발생하는 공간으로, 다수의 특수형 공조기가 설치되어 운용되고 있는데, 여기서 발생된 열은 열교환을 통하여 실외 기에서 그냥 외부로 버려지고 있다. 이 열은 겨울철에 사무실 난방과 온수공급에 필요한 적당한 온도와 풍부한 열량을 가지고 있어 그동안 활용 방법을 많이 모색해 왔으나, 시도되었던 제품이나 방법은 현실성이 떨어지거나 제품화 되지 못하고 있는 실정이었다. 이에, KT인프라연구소에서는 현실성 있는 제안으로 실외기로 가는 고온 고압의 냉매를 인접 사무실로 자동 전환시켜 난방을 가능케 하는 Package Type의 응축열 난방기를 개발하였는데, 본 논문에서는 이에 대한 개발과정과 Spec을 소개하고, 철저한 성능검증과 에너지 절감 효과 분석 결과를 제시하여 사업 적용에 필요한 기초자료로 활용 할 수 있도록 하였다. 개발된 응축열 난방기는 에너지를 대폭 절감할 수 있을 뿐 아니라 지구 온난화의 주범인 $CO_2$를 감축시킬 수 있어 대외 이미지 개선에도 크게 기여할 것이라고 생각된다.

  • PDF

A Performance Evaluation of Plate Type Enthalpy Exchanger through CFD Analysis of Elements (열 교환 소자 형상의 CFD 시뮬레이션을 통한 판형 전열 교환기 성능평가)

  • Kang, In-Sung;Ahn, Tae-Kyung;Park, Jin-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • In order to better save energy, many buildings have been constructed with high levels of insulation and airtightness in recent years. Additionally, having high quality indoor air has become more relevant, necessitating a ventilating system. This study is aimed at evaluating the performance of a humidity exchanger through computational fluid dynamics (CFD) analysis of elements for the purpose of providing comfortable indoor air and reduced energy consumption. The simulation was conducted with three different shapes (triangle, rectangular, and curve) of heat exchanger elements, in order to find the most effective element. A follow-up simulation then proved the efficiency of the chosen humidity exchanger, which was selected by analyzing the results of the preceding simulation, comparing study data with measurement data from the Korea Testing Laboratory (KTL). The resulting analysis revealed that the rectangular element showed the lowest level of efficiency in both heating and cooling, while the curved element showed the highest level of efficiency in both heating and cooling.

Approximate Model of Viscous and Squeeze-film Damping Ratios of Heat Exchanger Tubes Subjected to Two-Phase Cross-Flow (2 상 유동장에 놓인 열 교환기 튜브에 작용하는 점성과 압착막 감쇠비의 어림적 해석 모델)

  • Sim, Woo Gun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.1
    • /
    • pp.97-107
    • /
    • 2015
  • An analytical model was developed to estimate the viscous and squeeze-film damping ratios of heat exchanger tubes subjected to a two-phase cross-flow. Damping information is required to analyze the flow-induced vibration problem for heat exchange tubes. In heat exchange tubes, the most important energy dissipation mechanisms are related to the dynamic interaction between structures such as the tube and support and the liquid. The present model was formulated considering the added mass coefficient, based on an approximate model by Sim (1997). An approximate analytical method was developed to estimate the hydrodynamic forces acting on an oscillating inner cylinder with a concentric annulus. The forces, including the damping force, were calculated using two models developed for relatively high and low oscillatory Reynolds numbers, respectively. The equivalent diameters for the tube bundles and tube support, and the penetration depth, are important parameters to calculate the viscous damping force acting on tube bundles and the squeeze-film damping forces on the tube support, respectively. To calculate the void fraction of a two-phase flow, a homogeneous model was used. To verify the present model, the analytical results were compared to the results given by existing theories. It was found that the present model was applicable to estimate the viscous damping ratio and squeeze-film damping ratio.

Cooling Performance Characteristics of High-Performance Heat Pump with VI Cycle Using Re-Cooler (재냉기를 이용한 고성능 VI(Vapor Injection)사이클 열펌프의 냉방 성능특성에 관한 연구)

  • Lee, Jin-Kook;Choi, Kwang-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.6
    • /
    • pp.592-598
    • /
    • 2015
  • In this study, we experimentally investigate the performance characteristics of a high-performance summer-cooling heat pump for an R410A by applying an air-cooled-type vapor-injection (VI) cycle. The devices used for the experiment consist of a VI compressor, condenser, oil separator, plate-type heat-exchanger, economizer, evaporator, and re-cooler. The experimental conditions employed for the cooling performance were divided into three cycles. First, in Cycle A, we apply a VI cycle and with no heat exchange between the evaporator outlet refrigerant and the VI cycle suction refrigerant in the re-cooler. For Cycle B, there is heat exchange, and for Cycle C, there is neither a VI cycle nor heat exchange between the evaporator outlet refrigerant and the VI cycle suction refrigerant. From the analysis results, we observe that the performance was highest in the VI cycle with heat exchange between the evaporator outlet refrigerant and the VI cycle suction refrigerant (Cycle B), while it was lowest in Cycle C without application of the VI cycle. Moreover, the cooling coefficient of Performance ($COP_C$) averaged 3.5 in Cycle B, which was 8.6% higher than the corresponding value in Cycle A, and 33% higher than that in Cycle C.

Finned Tube Heat Exchanger for Air Conditioning System (공조기용 Finned Tube 열교환기)

  • 김무환
    • Journal of the KSME
    • /
    • v.35 no.9
    • /
    • pp.776-793
    • /
    • 1995
  • 인간이 쾌적한 환경을 요구하는 수준과 함께 개발 및 개선되어 온 공조용 finned tube 열교환 기에 대한 연구는 앞으로도 환경과 소형화 및 정숙 운전의 요구에 부응하기 위하여 지속적인 연구 및 개선이 요구될 것이다. 또한, 생산기술이 발달함에 따라 이에 적합한 새로운 형태의 경 제적이고 효율적인 열교환기의 설계가 필요할 것이다. 특히 앞으로 중요성이 더욱 강조될 환경 오염, 재료의 재활용 등의 측면은 현재 우리가 개척해야 할 분야일 것이다. 한편으로는 국내의 짧은 열교환기 개발의 역사에 의하여 지금까지 사용되어 온 외국의 기술 및 특허 등의 무 제에 대하여 국내 고유의 기술을 보유할 수 있도록 더욱 노력을 하여야 할 것이다. 나아가 실제 열 교환기에서의 확장표면의 효과, 냉동유의 영향 그리고 혼합냉매의 열전달 특성 등을 고려할 수 있는 상관식을 개발함으로써 국내의 열교환기 설계기술이 외국에 비하여 우위를 점할 수 있도록 하는 노력이 계속되어야 할 것이다. 그리고 미래까지 이러한 기술적 우위를 지속하기 위해서는 혼합냉매의 상변화 열전달현상의 기본 메카니즘을 밝히는 등의 열교환기에서의 열유동특성에 대한 기초적인 연구와 새로운 형태의 열교환기 개발 및 전기장을 이용한 열전달 촉진 등의 신 기술을 이용한 열전달 연구 등에 대한 투자와 관심이 지속되어야 한다.

  • PDF

Mistakes of Cooling Tower Performance Analysis (냉각성능 분석오류)

  • 권오익
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.3
    • /
    • pp.397-404
    • /
    • 2004
  • 냉각탑이란 석유화학플랜트, 철강플랜트 등과 같은 생산 공정이나 냉동기를 비롯한 각종 기계장치에서 발생된 열을 수냉식 열 교환장치에서 물로 직접 냉각시킬 때 공정유체의 열을 전달받아 데워진 물을 대기의 공기와 직접 접촉시켜 물의 증발 잠열을 이용하여 원하는 온도로 냉각시켜 주는 기계장치이다.(중략)

A Note on Direct Contact Exchangers (직접방식 열교환기와 전달특성)

  • 김석현
    • Journal of the KSME
    • /
    • v.35 no.9
    • /
    • pp.829-835
    • /
    • 1995
  • 통상의 열교환기에서 전열면이 제거된 형태의 직접열교환을 통하여 제작비나 열전달 특성에 큰 효과를 얻을 수도 있어 에너지이용 합리화에 기여하는 특성과 사례를 언급하였다. 또한 통상의 열교환기 설계와 다른 매질간의 공유계면에서 발생 가능한 전달특성을 위주로 설계상의 일부 유의사항을 기술하였다. 직접열교환의 기술축적은 상변화를 동반하는 열전달(two phase heat transfer) 문제의 기초지식은 물론, 염수플랜트(desalination)의 기본 요소설계, 원자로의 냉각계 통사고(LOCD)대책, 기타 냉각탑, 탱크가열, 증발기(evaporator), 건조장치(drier), 각종 기계, 화공 공정장치 설계 등 매우 광범위한 기술파급 효과도 기대할 수 있으므로 관련 기술자들의 많은 관심을 기대한다.

  • PDF

An Investigation on the Heat Efficiency of Hot Air Heater (온풍난방기 열효율조사 연구)

  • Kim, Yeong-Jung;Yu, Yeong-Seon;Gang, Geum-Chun;Baek, Lee;Yun, Jin-Ha
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.133-138
    • /
    • 2002
  • 온풍난방기 20대를 대상으로 온풍난방기의 베기가스중 탄산가스농도, 온풍온도차, 배기가스온도 및 열효율을 조사하여 사용연수별로 분석하였으며 주요 결과는 다음과 같다. 가. 사용연수별 온풍난방기 배기가스중 탄산가스농도와 온풍온도차는 사용연수에 따른 조사표본의 부족으로 큰 차이가 있었다고 하기는 어렵고 정확한 조사를 위해서는 보다 많은 대수가 필요할 것으로 판단된다. 나. 사용연수별 배기가스온도는 사용연한이 오래될수록 높아졌다고 판단된다. 이는 열교환기에서 흡입공기와 연소열이 열교환이 충분히 이루어지지 않았거나, 버너노즐의 노후화, 버너송풍기, 온풍난방기 송풍기의 노후화에 따른 결과라 여겨진다. 사용연수에 따른 배기가스온도는 회귀방정식 Y= 79.032Ln(X) + 116.66 ($R^2$= 0.6784)로 나타낼 수 있었다. 다. 사용연수별 온풍난방기의 열효율은 사용연한이 오래될수록 감소하는 경향을 보였으며 회귀방정식 Y = 95.167 X $^{-0.054}$ ($R^2$= 0.5696)로 나타낼 수 있었다.

  • PDF