• Title/Summary/Keyword: 열확산비

Search Result 211, Processing Time 0.039 seconds

A Study on the Installation and Abolition of Convergence Department in University (한국 대학의 융합학과 설치와 폐과 현황 분석)

  • Oh Dayyoung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.1
    • /
    • pp.111-119
    • /
    • 2024
  • This study analyzed the current status of the convergence departments of universities from 2019 to 2023. The number of installation increased from 430 in 2019 to 649 in 2023. The accumulated number of abolition increased from 177 to 509 at the same period. Many were suddenly installed without enough readiness. The convergence department bubble phenomenon began to extinguish in 2022. The number of the convergence departments in academic division was more in the order of engineering, humanities and social sciences, natural sciences, and arts and sports every year. The proportion of engineering decreased and that of humanities and social sciences increased. The number of sub-division installing convergence departments increased from 65 to 81 during 5 years. Convergence education was in the process of gradually spreading to various fields.

Effects of Fire Curtain and Forced Smoke Ventilation on Smoke Spread to Auditorium in Stage Fire of Theater (공연장 무대 화재 시 방화막과 강제 배연구가 객석으로의 연기 확산에 미치는 영향)

  • Kim, Jae Han;Kim, Duncan;Lee, Chi Young
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.28-36
    • /
    • 2017
  • In this work, the effects of fire curtain and forced smoke ventilation on smoke spread to auditorium in the stage fire of theater were investigated using the Fire Dynamics Simulator (FDS). For the stage of 31 m (Width)${\times}$34 m (Depth)${\times}$32 m (Height) in dimension, the fast growth fire condition with 10 MW of heat release rate was applied. The forced smoke ventilation was set based on the National Fire Safety Code (NFSC) and previous research. The gap distances between the fire curtain and proscenium wall was established to be 0 m and 0.5 m. When the fire curtain was attached completely to the proscenium wall without any gap, no smoke spread from the stage to the auditorium occurred, independent of forced smoke ventilation. When the gap distance between the fire curtain and proscenium wall was 0.5 m, the smoke layer in the stage descended to the lower height from the bottom than the case without the fire curtain, which was because the smoke spread to auditorium was impeded by the fire curtain. Under the same fire curtain condition, the case with the forced smoke ventilation led to decreasing the mass flow rate of outflow through the gap between the fire curtain and proscenium wall, as compared to the case without the forced smoke ventilation. Based on this study, it was confirmed that the fire curtain and forced smoke ventilation were the effective tools to hold down the smoke spread to the auditorium in the stage fire of theater.

A Comparison of Laser Flash and the Divided-bar Methods of Measuring Thermal Conductivity of Rocks (암석 열전도도 측정을 위한 Laser Flash Method와 Divided-bar Method 비교)

  • Oh, Jae-Ho;Kim, Hyoung-Chan;Park, Jeong-Min
    • Economic and Environmental Geology
    • /
    • v.44 no.5
    • /
    • pp.387-397
    • /
    • 2011
  • In this study, we conducted the study of the merits and demerits of the laser flash and the divided-bar methods for measuring the thermal conductivity of rocks and investigated applicability of the divided-bar apparatus which was developed by KIGAM. The laser flash method can measure thermal diffusivity, specific heat capacity, and thermal conductivity of rocks with even small thickness (< ~3 mm) in the high temperature range($25-200^{\circ}C$) in non-contact mode. For the laser flash method, samples must be uniform and homogeneous. In the case of the divided-bar method, the apparatus measures only thermal conductivity of rock samples at the room temperature. We measured thermal conductivities of 12 rock samples with low density and high porosity using two methods. In the laser flash method, there exist potential errors caused by the effect of pulse dispersion and reflection by various minerals and porosity in rock samples; the difference in thermal conductivity values measured on the front surface and the opposite surface ranges from 0.001 to 0.140 W/mK with the standard deviation of 0.003~0.089 W/mK, which seems to be caused by heterogeneity of rock samples. On the contrary, the divided-bar apparatus shows stable thermal conductivity measurements and relatively small measurement errors; the difference in thermal conductivity values, just as we applied to the laser frash method, is 0.001~0.016 W/mK with the standard deviation 0.001~0.034 W/mK. In turn, the divided-bar method can be applied to more thick samples that are more representative of bulk thermal conductivity.

(U-Th)/He Dating: Principles and Applications ((U-Th)/He 연령측정법의 원리와 응용)

  • Min, Kyoung-Won
    • The Journal of the Petrological Society of Korea
    • /
    • v.23 no.3
    • /
    • pp.239-247
    • /
    • 2014
  • The (U-Th)/He dating utilizes the production of alpha particles ($^4He$ atoms) during natural radioactive decays of $^{238}U$, $^{235}U$ and $^{232}Th$. (U-Th)/He age can be determined from the abundances of the parent nuclides $^{238}U$, $^{235}U$ and $^{232}Th$ and the radiogenic $^4He$. Because helium is one of the noble gases (non-reactive) with a relatively small radius, it diffuses rapidly in many geological materials, even at low temperatures. Therefore, ingrowth of $^4He$ during radioactive decay competes with diffusive loss at elevated temperatures during the geologic time scale, determining the amount of $^4He$ existing today in natural samples. For example, He diffusion in apatite is known to be very rapid compared to that in most other minerals, causing a significant diffusive loss at ${\sim}80^{\circ}C$ or higher. At ${\sim}40^{\circ}C$, He diffusion in apatite becomes slow enough to preserve most $^4He$ in the sample. Thus, an apatite's (U-Th)/He age represents the timing when the sample passed through the temperature range of $80-40^{\circ}C$. The crustal depth corresponding to this temperature range is called a "partial retention zone." Normal closure temperatures for a typical grain size and cooling rate are ${\sim}60-70^{\circ}C$ for apatite and ${\sim}200^{\circ}C$ for zircon and titanite. Because the apatite He closure temperature is lower than that of most other thermochronometers, it can provide critical constraints on relatively recent or shallow-crustal exhumation histories.

Thickness Dependence of Low-Field Tunnel-Type Magnetoresistance in$La_{2/3}Sr_{1/3}MnO_3SiO_2/Si(100)$ Thin Films ($La_{2/3}Sr_{1/3}MnO_3SiO_2/Si(100)$ 박막의 저-자장 터널형 자기저항변화의 두께 의존성)

  • 심인보;안성용;김철성
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.3
    • /
    • pp.97-103
    • /
    • 2001
  • Polycrystalline thin films of La$_{2}$3/Sr$_{1}$3/MnO$_3$(LSMO) were prepared by water-based sol-gel processing on thermally oxidized Si(100) substrate. The thickness dependence of the low-field tunnel-type magnetoresistance properties at room temperature was studied. Tunnel-type magnetoresistance at low-field is found to be strongly dependent on film thickness. Maximum value of tunnel-type magnetoresistance of LSMO thin films was appeared at the film thickness of ~1500 $\AA$. This behavior can be explained in terms of dead layer between LSMO thin film and Si(100) substrate and thermal lattice strain effect in the LSMO thin films.

  • PDF

Analysis of Shear Flow Dispersion Using Sequential Mixing Model (순차혼합모형에 의한 전단류 분산 해석)

  • Seo, Il-Won;Son, Eun-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.991-995
    • /
    • 2005
  • 본 연구에서는 1차원 이송-분산 과정을 연구하고 전단류 흐름 및 분산거동에 있어 Taylor 이론의 핵심이라 할 수 있는 '종방향 이송과 횡방향 확산의 균형'을 기본 개념으로 하여, 이송과 확산을 분리하여 이 두 과정이 순차적으로 발생한다는 가정에 의거한 순차혼합모형을 제시하였다. 본 모형에서는 가상의 하천을 여러 개의 행과 종방향 거리를 길이가 일정한 구획으로 나누어 연속적인 분산과정을 이산적인 형태로 나타낼 수 있게 하고, 횡방향 유속분포에 따라 각 행에 각기 다른 유속을 할당한다. 오염물질은 하폭방향 선오염원으로 원점에 순간주입되며, 주어진 혼합시간 $t_m$ 동안 각 행의 오염물질들이 각자에 할당된 유속을 따라 진행하고 진행이 끝난 후 횡방향 확산이 순간적으로 이루어진다. 횡방향 확산은 횡방향으로 완전하게 일어남을 가정하여, 횡방향 확산이 끝나면 각 열에서의 농도 평균값이 할당된다. 이러한 혼합시간 $t_m$ 동안의 순차적인 이송-확산 과정이 반복되면서 오염물질의 분산이 일어나며, 농도 분포 그래프를 그릴 수 있게 된다. 순차혼합모형을 가상의 직선하천에 적용하여 종분산계수를 유도하였는데, 본 연구에서 유도된 종분산계순식은 Fischer.가 제안한 식과 유사한 형태로 나타남을 알 수 있었다. 본 모형에서 계산된 농도분포 곡선을 해석해와 비교한 결과,두 곡선이 적절히 일치함을 확인할 수 있었으며 해석해와의 비교를 통해 종분산계수 K가 혼합시간 $t_m$과 선형관계임을 확인할 수 있었다. 수심대하폭비에 따라 각기 다른 유속분포에 적용하여 종분산계수 K가 유속편차강도의 제곱에 비례관계에 있음이 밝힐 수 있었다. 수압은 $4.69kg/cm^2$으로 나타났다. 밸브 개폐도가 $100\%$일 때가 밸브를 $60\%$$80\%$ 개폐시켰을 때보다 $0.3kg/cm^2,\;0.29kg/cm^2$ 낮게 나타나 밸브를 전체 개방 했을 때 관로내의 수압이 상수설계기준에 적합한 수압을 유지함을 알 수 있다. 상수관로 설계 기준에서는 관로내 수압을 $1.5\~4.0kg/cm^2$으로 나타내고 있는데 $6kg/cm^2$보다 과수압을 나타내는 경우가 $100\%$로 밸브를 개방하였을 때보다 $60\%,\;80\%$ 개방하였을 때가 더 빈번히 발생하고 있으므로 대상지역의 밸브 개폐는 $100\%$ 개방하는 것이 선계기준에 적합한 것으로 나타났다. 밸브 개폐에 따른 수압 변화를 모의한 결과 밸브 개폐도를 적절히 유지하여 필요수량의 확보 및 누수방지대책에 활용할 수 있을 것으로 판단된다.8R(mm)(r^2=0.84)$로 지수적으로 증가하는 경향을 나타내었다. 유거수량은 토성별로 양토를 1.0으로 기준할 때 사양토가 0.86으로 가장 작았고, 식양토 1.09, 식토 1.15로 평가되어 침투수에 비해 토성별 차이가 크게 나타났다. 이는 토성이 세립질일 수록 유거수의 저항이 작기 때문으로 생각된다. 경사에 따라서는 경사도가 증가할수록 증가하였으며 $10\% 경사일 때를 기준으로 $Ro(mm)=Ro_{10}{\times}0.797{\times}e^{-0.021s(\%)}$

  • PDF

A Study on the Improved Parity Check Receiver for the Extended m-sequence Based Multi-code Spread Spectrum System with Code Set Partitioning and Constant Amplitude Precoding (코드집합 분할 방식의 확장 m-시퀀스 기반 정진폭 멀티코드 대역확산 통신 시스템을 위한 개선된 패리티 검사 기반 수신기에 관한 연구)

  • Han, Jun-Sang;Kim, Dong-Joo;Kim, Myoung-Jin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.8
    • /
    • pp.1-11
    • /
    • 2012
  • The multi-code spread spectrum communication system, which spreads data bit stream by multiplexing orthogonal codes, can transmit data in high rate. However it needs the high-cost good linear amplifier because of the multi-level output signal. In order to overcome this drawback several systems making the amplitude of output signal constant with Walsh codes have been proposed. Recently constant amplitude pre-coded multi-code spread spectrum systems using extended m-sequence have been proposed. In this paper we consider an extended m-sequence based constant amplitude multi-code spread spectrum system with code set partitioning. By grouping the orthogonal codes into 4 subsets, not only is the computational complexity of the transceiver reduced but BER performance also improves. It has been shown that parity checking on four detected codes at the receiver can correct code detection error and result in BER performance enhancement. In this paper we propose a improved parity check receiver. We carried out computer simulation to verify feasibility of the proposed algorithm.

NUMERICAL STUDY ON NATURAL CONVECTION HEAT TRANSFER IN A CAVITY CONTAINING A CENTERED HEAT CONDUCTING BODY (열전도 물체가 존재하는 캐비티내 자연대류 열전달에 대한 수치적 연구)

  • Myong H. K.;Chun T. H.
    • Journal of computational fluids engineering
    • /
    • v.10 no.3 s.30
    • /
    • pp.36-42
    • /
    • 2005
  • The present study numerically investigates the natural convection heat transfer in a 2-D square cavity containing a centered heat conducting body. Special emphasis is given to the influences of the Rayleigh number, the dimensionless conducting body size, and the ratio of the thermal diffusivity of the body to that of the fluid on the natural convection heat transfer in overall concerned region. The analysis reveals that the fluid flow and heat transfer processes are governed by all of them. Results for isotherms, vector plots and wall Nusselt numbers are reported for Pr = 0.71 and relatively wide ranges of the other parameters. Heat transfer across the cavity, in comparison to that in the absence of a body, are enhanced (reduced) in general by a body with a thermal diffusivity ratio less (greater) than unity. It is also found that the heat transfer attains a minimum as the body size is increased with a thermal diffusivity ratio greater than unity.

A Study on Transition of Flame Extinction at Low Strain Rate Counterflow Flames (저신장율 대향류화염에서 화염소화에 있어서 천이에 대한 연구)

  • Park, Dae-Geun;Park, Jeong;Kim, Jeong-Soo;Bae, Dae-Suk
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.197-201
    • /
    • 2009
  • Experiments were conducted to study the transition of shrinking flame disk to flame hole in counterflow diffusion flames. The studies of transition are well described by varying burner diameters, global strain rate and velocity ratio. It is experimentally verified that radial conduction heat loss is affected at even high strain rate flames for appropriately small burner diameters. It is also shown that flame extinction modes are grouped into three and particularly, hole or stripe is observed in sufficiently high strain rate flames. There exists critical radius according to burner diameter which divide flame extinction modes into three parts.

  • PDF

Characterization of Graphene Transparent Conducting Film Fabricated on Self-Assembled Monolayers/Polyethylene Terephthalate

  • Go, Yong-Hun;Jeong, Dae-Seong;Adhikari, Prashanta Dhoj;Cha, Myeong-Jun;Jeon, Seung-Han;Park, Jong-Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.380.1-380.1
    • /
    • 2014
  • 열 화학기상증착법은 여러 가지 그래핀의 제작방법 중 대면적으로 양질의 그래핀을 효과적으로 합성할 수 있는 방법으로 널리 이용되고 있다. 이 방법으로 그래핀을 합성할 경우, 주요 변수로 성장 온도와 촉매 금속이 있으며 이를 적절히 조절함으로써 합성되는 그래핀의 결정성과 층수를 조절할 수 있다[1-3]. 본 연구에서는 탄소 용해도가 작은 두꺼운 촉매 금속 기판 위에 선택적인 위치에 탄소 용해도가 큰 얇은 촉매 금속을 증착하여 그래핀의 층수를 적절하게 제어하고자 한다. 그래핀을 합성하기 위해 온도를 증가시키는 과정에서 두 층의 촉매 금속은 표면 에너지를 낮추기 위해 합금을 형성하게 되며, 이 때 탄소 용해도가 변화할 것으로 예상된다. 이 변화하는 탄소 용해도에 맞추어 탄소 공급원인 메탄 가스를 주입하는 시기를 적절히 조절하게 되면, 합성되는 그래핀의 층수 조절이 가능할 것이라 예상한다. 탄소 용해도가 큰 금속으로 니켈을, 탄소 용해도가 작은 금속으로 구리를 선택하였다. 우선 니켈의 확산 거리를 계산하여 메탄 가스를 주입하는 적절한 온도를 결정하였으며, 이 온도를 기준으로 표면에서의 니켈의 함량을 분석하였다. 니켈의 함량과 표면에서의 탄소의 구성비의 관계를 조사한 결과, 본 실험에서 이용한 방법으로 그래핀의 층수를 조절하는 것이 가능하다는 것을 확인하였다.

  • PDF