• Title/Summary/Keyword: 열화상 장치

Search Result 55, Processing Time 0.029 seconds

Development of LabVIEW Program for Lock-In Infrared Thermography (위상잠금 열화상장치 제어용 랩뷰 프로그램 개발)

  • Min, Tae-Hoon;Na, Hyung-Chul;Kim, Noh-Yu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.2
    • /
    • pp.127-133
    • /
    • 2011
  • A LabVIEW program has been developed together with simple infrared thermography(IRT) system to control the lock-in conditions of the system efficiently. The IR imaging software was designed to operate both of infrared camera and halogen lamp by synchronizing them with periodic sine signal based on thyristor(SCR) circuits. LabVIEW software was programmed to provide users with screen-menu functions by which it can change the period and energy of heat source, operate the camera to acquire image, and monitor the state of the system on the computer screen. In experiment, lock-in IR image for a specimen with artificial hole defects was obtained by the developed IRT system and compared with optical image.

An analytical and numerical study of a vertically-discretized wavemaker (수직다열화된 조파장치의 해석해 개발 및 수치모형 실험)

  • Son, Sangyoung;Kim, Yeulwoo;Jung, Taehwa
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.103-103
    • /
    • 2021
  • 실험실에서의 파랑생성에 흔히 사용되는 피스톤형 조파장치는 수심에 따라 유속이 동일하게 생성된다는 제약이 있어 주로 천해파의 생성에 적합한 것으로 알려져 있다. 본 연구에서는 이러한 제약조건 없이 다양한 유속분포의 파형을 생성하는 수직 다열화된 조파장치가 개발되었다. 우선, 수심방향으로 이산화된 각 패들(paddle)의 스트로크에 대해 선형해석해가 유도되었다. 개발된 해석해는 패들의 수 및 유속분포에 따라 기존의 피스톤형 혹은 플랩형 조파장치 해석해로 근사함이 밝혀짐으로써 포괄적으로 활용될 수 있음이 확인되었다. 즉 개발된 해석해를 활용하면 선택적으로 피스톤형 및 플랩형 조파성능이 구현될 수 있다. 더불어 개발된 해석해는 다상유체의 내부파 생성에도 확정되어 적용가능함이 확인되었다. 다음으로, 개발된 조파장치를 수치적으로 구현하였다. 오픈소스 3차원 수치모형인 OpenFOAM 중, 두 개 이상의 불연속 및 비압축 유체에 대한 Navier-Stokes 방정식을 해결하는 수치 모듈을 사용하여 제안된 수직다열화된 조파장치의 성능이 평가되었다. 이때 동적격자모델(olaDyMFlow)을 결합함으로써 개발된 조파장치 움직임이 물리적 조파장치와 흡사하도록 수치적으로 구현하였다. 모의결과, 여러 개의 다열화된 패들이 층류 흐름 조건에서 심해파를 효율적으로 생성시키고, 중간수심 파랑조건에서는 제안된 조파장치가 상대적으로 덜 유리함을 확인할 수 있었다. 마지막으로 공기, 기름 및 물 등 3상의 흐름조건에서 단 두 개의 패들을 활용하여 각각 내부파 및 표면파를 생성하되었으며, 모의 결과는 해석해과 비교됨으로써 개발된 조파장치의 성능이 검증되었다.

  • PDF

Method for Measuring Weld Temperature Using an Infrared Thermal Imaging Camera (적외선 열화상 카메라를 이용한 용접부의 온도 측정 방법)

  • Ro, Chan-Seung;Kim, Kyeong-Suk;Chang, Ho-Seob
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.4
    • /
    • pp.299-304
    • /
    • 2014
  • In this paper, a method is tested to measure temperatures in high-temperature welds. Protective glass was installed between an infrared thermal imaging camera and a heat source, and temperature compensation was applied to the measuring instruments. When the temperature of halogen lamps was taken in real-time and measured by the thermal camera, the temperature was found to be almost invariant with the distance between the camera and heat source. The temperature range could be predicted, through correlations with the thickness of the protective glass and the measured distance. This study suggests that the temperature measurement of welds obtained by using an infrared thermal imaging camera is valid, through experimental testing of heat sources.

Early Detection of Foliar Damage Caused by Ozone Exposure with Thermal Image Analysis (식물체 잎표면의 열화상 분석을 통한 오존 피해 조기 진단)

  • 허재선;이충일
    • Korean Journal Plant Pathology
    • /
    • v.12 no.1
    • /
    • pp.132-136
    • /
    • 1996
  • 오존에 의한 식물체의 가시피해 발현 이전에 나타나는 비가시적 피해를 찾아내기 위하여 적외선 열화상장치(infrared thermography)를 이용하여 하루 8시간씩 0.3 ppm 오존에 노출된 나팔꽃(Ipomoea purpurea)잎표면의 온도분포 변화를 조사하였다. 노출 첫날에는 온도분포의 뚜렷한 변화를 볼 수 없었다. 노출 2일째, 오존 노출 2시간 결과후, 완전히 자란 제3엽의 특정 부분에서 급격한 온도분포 변화를 보였으며, 그로부터 약 4시간 경과 후에 동일 지점에서 최초의 가시적 피해가 발생했다. 급격한 온도분포 변화를 보인 부분과 최초 가시피해가 발생한 부분이 일치한 점은 가시피해 발생과 그 이전의 온도분포 변화가 밀접하게 상관되어 있다는 것을 의미한다고 하겠다. 잎표면의 열화상 분석방법을 대기오염원에 의한 식물체의 가시피해 발현 이전에 진행되고 있는 비가시적 반응의 조기진단에 적용할 수 있으며 생태환경 친화적인 대기 환경관리를 위한 대기오염원은 배출조절용 생체반응기(biosensor)로 이용 가능하겠다.

  • PDF

A Method of the Arc Detection using IR Camera (적외선 카메라를 이용한 아크 검출 기법)

  • Park, Geon-Ho
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2016.01a
    • /
    • pp.321-322
    • /
    • 2016
  • 본 논문에서는 수배전반에서 부하 설비 또는 외부의 영향을 확인할 수 있는 장치 및 보호설비가 설치되어 있으나 자체 사고를 신속히 검출하고 판단할 수 있는 기술의 확보를 위하여 해상도가 낮은 저가의 열화상 센서에 고속 DSP(Digital Signal Process)를 사용하여 영상 처리 기법인 이차원 보간법 기술을 이용하여 아크플래시에 의해 발생되는 열 특성을 검출하고 검출된 데이터를 전송하여 전기화재사고를 미연에 방지할 수 있는 장치 개발을 위한 기초 특성 연구를 수행하였다.

  • PDF

Development of Gas Type Identification Deep-learning Model through Multimodal Method (멀티모달 방식을 통한 가스 종류 인식 딥러닝 모델 개발)

  • Seo Hee Ahn;Gyeong Yeong Kim;Dong Ju Kim
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.12 no.12
    • /
    • pp.525-534
    • /
    • 2023
  • Gas leak detection system is a key to minimize the loss of life due to the explosiveness and toxicity of gas. Most of the leak detection systems detect by gas sensors or thermal imaging cameras. To improve the performance of gas leak detection system using single-modal methods, the paper propose multimodal approach to gas sensor data and thermal camera data in developing a gas type identification model. MultimodalGasData, a multimodal open-dataset, is used to compare the performance of the four models developed through multimodal approach to gas sensors and thermal cameras with existing models. As a result, 1D CNN and GasNet models show the highest performance of 96.3% and 96.4%. The performance of the combined early fusion model of 1D CNN and GasNet reached 99.3%, 3.3% higher than the existing model. We hoped that further damage caused by gas leaks can be minimized through the gas leak detection system proposed in the study.

Study on the Micro Crack Detection in Joints by Using Ultrasound Infrared Thermography (초음파 적외선 열화상을 이용한 접합부의 미세균열 검출 연구)

  • Park, Hee-Sang;Choi, Man-Yong;Park, Jeong-Hak;Lee, Seung-Seok;Huh, Yong-Hak;Lee, Bo-Young;Kim, Jae-Seong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.162-169
    • /
    • 2012
  • This study detected SCC defects of dissimilar metal welded(STS304 and SA106 Gr. b) pipes using the ultrasonic infrared thermography method and the lock-in image treatment method among infrared thermography method. The infrared excitement equipment has 250 Watt of output and 20 kHz of frequency. By using the ultrasound infrared thermography method, the internal defects of dissimilar metal weld joints of pipes used at nuclear power plants could get detected. By an actual PT test, it was observed that the cracks inside the pipe existed not as a single crack but rather as a multiple cracks within a certain area and generated a hot spot image of a broad area on the thermography image. In addition, UT technology could not easily defects detected by the width of $10\;{\mu}m$ fine hair cracks. but, ultrasound infrared thermography technique was defect detected.

Voice Assistant for Visually Impaired People (시각장애인을 위한 음성 도우미 장치)

  • Chae, Jun-Gy;Jang, Ji-Woo;Kim, Dong-Wan;Jung, Su-Jin;Lee, Ik Hyun
    • The Journal of Korean Institute of Information Technology
    • /
    • v.17 no.4
    • /
    • pp.131-136
    • /
    • 2019
  • People with compromised visual ability suffer from many inconveniences in daily life, such as distinguishing colors, identifying currency notes and realizing the atmospheric temperature. Therefore, to assist the visually impaired people, we propose a system by utilizing optical and infrared cameras. In the proposed system, an optical camera is used to collect features related to colors and currency notes while an infrared camera is utilized to get temperature information. The user is enabled to select the desired service by pushing the button and the appreciate voice information are provided through the speaker. The device can distinguish 16 kinds of colors, four different currency notes, and temperature information in four steps and the current accuracy is around 90%. It can be improved further through block-wise input image, machine learning, and a higher version of the infrared camera. In addition, it will be attached to the stick for easy carrying and to use it more conveniently.

Study on Diagnosis of High Voltage Cables for Nuclear Power Plant (원자력발전소 고압케이블 열화진단에 관한 연구)

  • Ha, Che-Wung;Joo, Kwang-Ho;Han, Sung-Heum
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2061-2062
    • /
    • 2011
  • 국내 원자력발전소에 설치되어 있는 고압케이블은 장기운전에 따라 열화진단 및 유지보수의 필요성이 증대되고 있다. 주기적 안전성 평가(Periodic Safety Review) 및 계속운전과 관련하여서도 고압케이블의 관리방안이 지속적으로 요구되고 있다. 본 논문에서는 원자력발전소에 설치되어 있는 13.8kV급 고압케이블의 건전성을 확인하기 위하여 원자력발전소 계획예방정비 중 열화진단을 수행한 결과를 소개하고 있다. 특히 미국 NRC(Nuclear Regulatory Commission)에서는 케이블 진단 기법 11가지를 권고하고 있는데 본 논문에서는 그 중 국내 원자력발전소에 적용이 가능한 최신 케이블 진단 기술인 HFCT(High Frequency Current Transformer)를 이용한 부분방전(Partial Discharge ; PD) 측정, VLF(Very Low Frequency) 장치를 이용한 $Tan{\delta}$ 측정 및 열화상카메라를 이용한 케이블 온도 측정을 사용하여 고압 케이블 진단을 실시하였고, 그 결과를 서술하였다.

  • PDF

Non Destructive Technique for Steel Corrosion Detection Using Heat Induction and IR Thermography (열유도 장치와 적외선 열화상을 이용한 철근부식탐지 비파괴 평가기법)

  • Kwon, Seung Jun;Park, Sang Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.2
    • /
    • pp.40-48
    • /
    • 2012
  • Steel corrosion in concrete is a main cause of deterioration and early failure of concrete structures. A novel integration of electromagnetic heat induction and infrared (IR) thermography is proposed for nondestructive detection of steel corrosion in concrete, by taking advantage of the difference in thermal characteristics of corroded and non-corroded steel. This paper focuses on experimental investigation of the concept. An inductive heater is developed to remotely heat the embedded steel from concrete surface, which is integrated with an IR camera. Concrete samples with different cover depths are prepared. Each sample is embedded with a single rebar in the middle, resulting an identical cover depth from the front and the back surfaces, which enable heat induction from one surface and IR imaging from the other simultaneously. The impressed current (IC) method is adopted to induce accelerated corrosion on the rebar. IR video images are recorded during the entire heating and cooling periods. The test results demonstrate a clear difference in thermal characteristics between corroded and non-corroded samples. The corroded sample shows higher rates of heating and cooling than those of the non-corroded sample. This study demonstrates a potential for nondestructive detection of rebar corrosion in concrete.