• Title/Summary/Keyword: 열화상 시스템

Search Result 195, Processing Time 0.025 seconds

Implementation of Photovoltaic Panel failure detection system using semantic segmentation (시멘틱세그멘테이션을 활용한 태양광 패널 고장 감지 시스템 구현)

  • Shin, Kwang-Seong;Shin, Seong-Yoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.12
    • /
    • pp.1777-1783
    • /
    • 2021
  • The use of drones is gradually increasing for the efficient maintenance of large-scale renewable energy power generation complexes. For a long time, photovoltaic panels have been photographed with drones to manage panel loss and contamination. Various approaches using artificial intelligence are being tried for efficient maintenance of large-scale photovoltaic complexes. Recently, semantic segmentation-based application techniques have been developed to solve the image classification problem. In this paper, we propose a classification model using semantic segmentation to determine the presence or absence of failures such as arcs, disconnections, and cracks in solar panel images obtained using a drone equipped with a thermal imaging camera. In addition, an efficient classification model was implemented by tuning several factors such as data size and type and loss function customization in U-Net, which shows robust classification performance even with a small dataset.

A study on the development of tunnel soundness evaluation system using artificial neural network (인공신경망을 이용한 터널 건전도 평가시스템 개발)

  • 김현우;김영근;이희근
    • Tunnel and Underground Space
    • /
    • v.9 no.1
    • /
    • pp.48-55
    • /
    • 1999
  • One of the major roles of concrete lining is the supplementary support of ground load. Therefore, if there are cracks or deformation found in the lining, the causes should be carefully examined. Tunnel Soundness Evaluation System (DW-TSES) was developed to meet such requirements. Main facility of the system was intended to find the probable causes on the basis of the apparent changes in lining and the environmental conditions. It also includes facilities for evaluating the soundness of a tunnel and indicating the method for repair or reinforcement. The characteristic feature of damages is used for reasoning in case of deterioration and leakage, and artificial neural network is used in external pressure. This process depends on the results of the case analyses and FDM, which have a collection of the typical features of different types of damages as well as the unusual changes caused by the external pressure. The comparison of the outputs of this system with those of expert's diagnoses draws the following conclusions. 1) Artificial neural network was a suitable tool to find to causes of damages by external pressure. 2) The environmental conditions improved the accuracy in reasoning. 3) The result of finding causes and evaluating soundness was helpful to suggest effective methods concerning tunnel maintenance.

  • PDF

Improved Channel Profile Measurement Technique for ATSC Terrestrial DTV System (향상된 지상파 DTV 채널 프로파일 측정기술)

  • Lee, Jaekwon;Jeon, Sung-Ho;Kim, Jung-Hyun;Suh, Young-Woo;Kyung, Il-Soo
    • Journal of Broadcast Engineering
    • /
    • v.18 no.3
    • /
    • pp.435-444
    • /
    • 2013
  • ATSC terrestrial DTV system can support high data rates for HDTV(High Definition Television) service, but it suffers from significant performance degradation caused by multipath fading. Thus, it is necessary to analyze multipath fading effects in order to enhance the DTV reception performance. Generally, DTV channel profile can be obtained by auto-correlation between reference pseudo random signal and received DTV signal. However, in the ATSC terrestrial DTV system, the estimation performance of DTV channel profile may be decreased due to the VSB modulation features. In this paper, improved DTV channel profile measurement technique is analyzed and proposed.

Bit Error Probability Performance of Multi-carrier CDMA System Using M-band Cosine Modulated Filter Bank in the Mobile Radio Channel (M-밴드 코사인변조 필터뱅크를 이용한 멀티캐리어 CDMA 시스템의 이동무선환경에서의 비트오율 성능)

  • Kim, Myoung-Jin
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.6
    • /
    • pp.1-8
    • /
    • 1999
  • Multi-carrier CDMA is a transmission scheme where data symbols are spread in the frequency domain with a spread code then transmitted using multiple carriers. It is robust against narrowband interference because of its long symbol duration. However, due to large sidebands of the rectangular window frequency response, subchannels spectrally overlap with neighboring subchannels, which leads to substantial intercarrier interference in a dispersive channel. In this paper, we consider a mult-carrier CDMA system where subchannel spectral containment is achiveved by M-band cosine modulated filter bank (CMFB). In CMFB based MC-CDMA, subchannel spectral containment is achieved using the filter bank of longer impulse response than that of conventional discrete Fourier transform (DFT) filter bank. We show that spectral containment feature of the CMFB based fading channel is analyzed using computer simulations.

  • PDF

On Robust MMSE-Based Filter Designs for Multi-User Peer-to-Peer Amplify-and-Forward Relay Systems (증폭 및 전달 릴레이 기반 다중 사용자 피어투피어 통신 시스템에서 강인한 MMSE 필터 설계 방법)

  • Shin, Joonwoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.9
    • /
    • pp.798-809
    • /
    • 2013
  • In this paper, we propose robust relay and destination filter design methods for the multi-user peer-to-peer amplify-and-forward relaying systems while taking imperfect channel knowledge into consideration. Specifically, the relay and destination filter sets are developed to minimize the sum mean-squared-error (MSE). We first present a robust joint optimum relay and destination filter calculation method with an iterative algorithm. Motivated by the need to reduce computational complexity of the iterative scheme, we then formulate a simplified sum MSE minimization problem using the relay filter decomposability, which lead to two robust sub-optimum non-iterative design methods. Finally, we propose robust modified destination filter design methods which require only local channel state information between relay node and a specific destination node. The analysis and simulation results verify that, compared with the optimum iterative method, the proposed non-iterative schemes suffer a marginal loss in performance while enjoying significantly improved implementation efficiencies. Also it is confirmed that the proposed robust filter design methods provide desired robustness in the presence of channel uncertainty.

Performance and Operating Characteristics Analysis of the 16-APSK Modulation over Nonlinear Channels (16-APSK 변조 방식의 성능 및 비선형 채널에서의 동작 특성 분석)

  • Kang, Seok-Heon;Kim, Sang-Tae;Sung, Won-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.4C
    • /
    • pp.362-369
    • /
    • 2007
  • APSK (Amplitude Phase Shift Keying) digital modulation is characterized by the circular positioning of the transmission symbols in the constellation diagram. Due to such structural characteristics, the peak-to-average power ratio of the APSK modulation is lower than that of the QAM (Quadrature Amplitude Modulation), and the amount of performance degradation over nonlinear channels can be mitigated. The APSK modulation scheme has recently been adopted as satellite communication system standards including the DVB-S2 (Digital Video Broadcasting - Satellite, Version 2). In this paper, a BER (Bit Error Rate) upper bound approximation formula is derived using the channel model with the output power saturation characteristics, and its accuracy is demonstrated. Using the derived formula, the input power level that minimizes the BER is determined. The optimized performance based on the radii ratio of the 16APSK constellation and the channel saturation level is also presented.

A Study on Combustion Experiments of Multi Type Air-Conditioner Outdoor Units by Large Scale Calorimeter (라지스케일 칼로리미터에 의한 멀티시스템형 에어컨실외기의 연소실험에 관한 연구)

  • Min, Se-Hong;Bae, Yeon-Jun
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.168-177
    • /
    • 2011
  • The combustion test for real box of AC outdoor unit has been performed in this study in order to estimate the fire hazard in multi-system type of AC outdoor unit which is currently used for commercial use. The result showed that in test, there was explosion inside of AC outdoor unit, and flame erupted and fire spread through upper side grill. And then this fire burnt the combustibles such as wires, electronic control board, heat exchange copper plate and plastics etc inside the unit, refrigerant gas pipe was burst due to fire, and accelerated the explosion and flame eruption to outside while the refrigerant was erupting. It is found in this test that the maximum heat release rate of AC outdoor unit is 5,830 kW, the maximum internal temperature measured with infrared camera and thermocouple is $1,201^{\circ}C$, maximum ambient temperature is $881^{\circ}C$, and flame rose higher than about 5 m. It is concluded that the fire in AC outdoor unit cause fire to combustibles around the unit, and may give big damage by generating the secondary fire. It is expected that the result obtained from the test on the real object may be applied to fire realization of AC outdoor unit and estimation of fire spreading to the combustibles around in the future computer simulation.

A Study on the Application Method of Facility Classification System for the Development of Asset Management System for Power Generation Structures (발전구조물의 자산관리 시스템 구축을 위한 시설물분류체계 활용방안에 관한 연구)

  • Jeon, Seokhyeon;Jeong, Jeongsik;Ahn, Jinhee;Kim, Changhak
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.2
    • /
    • pp.113-118
    • /
    • 2019
  • Recently, the maintenance concept of infrastructure has been changed from the stability management of the structure determined by the safety inspection of the existing facilities to the asset management related to evaluating and managing the performance of the facilities. For management of the property of the facilities, it is necessary to efficiently classify their information for the maintenance and service level of the facilities and to manage them. In the case of power plant facility, especially, it is a complex structure, which is constructed in a various component and detail. In this study, therefore, the components of power plant facility were classified into facilities, spaces, parts, and elements considering the type of integrated construction classification system in Korea. To reflect the deterioration rate of the facility in accordance with environmental conditions such as airborne salt and humidity etc., it was classified by adding direction, interior, and exterior condition of each component not to be considered in the existing classification system for its effective and systematic maintenance, since it is generally located in the coastal area due to the operation of the power generation structure. The classification system developed in this study can be used as fundamental data for development of the computer system for asset management of power plant facility.

Patrol Monitoring Plan for Transmission Towers with a Commercial Drone and its Field Tests (상용화 드론을 이용한 송전선로 점검방안 및 현장시험)

  • Kim, Seok-Tae;Park, Joon-Young;Lee, Jae-Kyung;Ham, Ji-Wan;Choi, Min-Hee
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.2
    • /
    • pp.115-123
    • /
    • 2018
  • Various types of robots running on power transmission lines have been developed for the purpose of line patrol monitoring. They usually have complex mechanism to run and avoid obstacles on the power line, but nevertheless did not show satisfactory performance for going over the obstacles. Moreover, they were so heavy that they could not be easily installed on the lines. To compensate these problems, flying robots have been developed and recently, multi-copter drones with flight stability have been used in the electric power industry. The drones could be remotely controlled by human operators to monitor power distribution lines. In the case of transmission line patrol, however, transmission towers are huge and their spans are very long, and thus, it is very difficult for the pilot to control the patrol drones with the naked eye from a long distance away. This means that the risk of a drone crash onto electric power facilities always resides. In addition, there exists another danger of electromagnetic interference with the drones on autopilot waypoint tracking under ultra-high voltage environments. This paper presents a patrol monitoring plan of autopilot drones for power transmission lines and its field tests. First, the magnetic field effect on an autopilot patrol drone is investigated. Then, how to build the flight path to avoid the magnetic interference is proposed and our autopilot drone system is introduced. Finally, the effectiveness of the proposed patrol plan is confirmed through its field test results in the 154 kV, 345 kV and 765 kV transmission lines in Chungcheongnam-do.

Effect of Growing Part Following Local Heating for Cherry Tomato on Temperature Distribution of Crop and Fuel Consumption (방울토마토 생장부 추종 국소난방이 군락 온도분포 및 연료소비에 미치는 영향)

  • Kwon, Jin Kyung;Kang, Geum Chun;Moon, Jong Pil;Lee, Tae Seok;Lee, Su Jang
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.217-225
    • /
    • 2015
  • Local heating system providing hot air locally to growing parts including shoot apex and flower cluster which were temperature-sensitive organs of cherry tomato was developed to reduce energy consumption for greenhouse heating without decline of crop growth. Growing part following local heating system was composed of double duct distributer which connected inner and outer ducts with hot air heater and winder which moved ducts up and down following growing parts with plant growth. Growing part local heating system was compared with conventional bottom duct heating system with respect to distributions of air and leaf surface temperatures according to height, growth characteristics and energy consumption. By growing part local heating, air temperature around growing part was maintained $0.9{\sim}2.0^{\circ}C$ higher than that of lower part of crop and leaf surface temperature was also stratified according to height. Investigations on crop growth characteristics and crop yield showed no statistically significant difference except for plant height between bottom duct heating and growing part local heating. As a result, the growing part local heating system consumed 23.7% less heating energy than the bottom duct heating system without decrease of crop yield.