• Title/Summary/Keyword: 열화곡선

Search Result 73, Processing Time 0.028 seconds

Analysis for Threshold-voltage of EPI MOSFET (EPI MOSFET의 문턱 전압 특성 분석)

  • 김재홍;고석웅;임규성;정학기;이종인
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.665-668
    • /
    • 2001
  • As reducing the physical size of devices, we can integrate more devices per the unit chip area and make its speed better. We have investigated MOSFET built on an epitaxial layer(EPI) of a heavily-doped ground plane. We compared and analyzed the characteristics of such device structure, i.e., impact ionization, electric field and I-V characteristics curve with lightly-doped drain(LDD) MOSFET. We simulated MOSFET with gate lengths from 0.10 to 0.06${\mu}{\textrm}{m}$ step 0.01${\mu}{\textrm}{m}$ in according to constant voltage scaling theory.

  • PDF

New Fire Resistant Method of Reinforced Tunnel Structures Using Engineered Cementitious Composites (터널구조물의 내화대책에 대한 ECC 적용 가능성)

  • Kim, Jung-Hee;Kwon, Young-Jin;Lee, Hye-Kyung;Kim, Jae-Jwan;Han, Byung-Chan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.441-448
    • /
    • 2009
  • 화재에 대한 안전성 확보는 ECC 등과 같은 신소재를 실제 구조물에 적용 또는 실용화하기 위해 필요한 중요한 요소 중 하나이다. 본 논문은 터널구조물에 대한 내화대책의 일환으로써 ECC의 적용가능성을 평가하고자 하는 것을 목적으로 한다. 이를 위하여 터널구조물의 화재 온도조건인 RABT 화재온도이력곡선을 적용하여 내화성능을 실험적으로 평가하였다. 또한 비정상 온도분포해석 기법을 이용하여 이를 해석적으로 묘사 검증하였으며, 실험결과를 통해 검증된 해석기법을 이용하여 터널라이닝에 대한 열전달 해석을 수행하여 ECC의 적용가능성을 고찰하였다. 실험결과 ECC는 폭렬 및 화재상태에서의 모체콘크리트에 열화가 발생하지 않았으며, 기존 콘크리트 및 내화소재와의 상대 비교에 있어서도 가장 우수한 내화성능을 나타냈다. 이를 통하여 터널구조물의 내화대책에 있어 ECC 소재가 적용가능성이 있는 것으로 판단되었다.

  • PDF

Experimental Investigation on Torsional Analysis and Fracture of Tripod Shaft for High-speed Train (고속열차용 트리포드 축의 비틀림 해석 및 파단에 대한 실험적 연구)

  • Lee, Joo Hong;Kim, Do Sik;Nam, Tae Yeon;Lee, Tae Young;Cho, Hae Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.11
    • /
    • pp.979-986
    • /
    • 2016
  • The tripod shafts of constant-velocity joint are used in both the trains KTX and KTX-sanchon. It is an important component that connects the motor reduction unit and the axle reduction unit in a power bogie. The tripod shaft not only transmits drive and brake torque in the rotational direction, but also slides in the axial direction. If the drive system is loaded with an excessive torque, the fuse part of the shaft will be fractured firstly to protect the other important components. In this study, a rig was developed for conducting torsion tests on the tripod shaft, which is a type of mechanical fuse. The tripod shafts were subjected to torsional fracture test and torsional fatigue test on the rig. The weak zone of the tripod shaft was identified, and its fatigue life was predicted using finite element analysis (FEA). After analyzing the FEA results, design solutions were proposed to improve the strength and fatigue life of the tripod shaft. Furthermore, the deterioration trend and time for failure of the tripod shaft were verified using the hysteresis loops which had been changed with the advancement of the torsional fatigue test.

A Dynamic Behavior Evaluation of the Curved Rail according to Lateral Spring Stiffness of Track System (궤도시스템의 횡탄성에 따른 곡선부 레일의 동적거동평가)

  • Kim, Bag-Jin;Choi, Jung-Youl;Chun, Dae-Sung;Eom, Mac;Kang, Yun-Suk;Park, Yong-Gul
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.517-528
    • /
    • 2007
  • Domestic or international existing researches regarding rail damage factors are focused on laying, vehicle conditions, driving speed and driving habits and overlook characteristics of track structure (elasticity, maintenance etc). Also in ballast track, as there is no special lateral spring stiffness of track also called as ballast lateral resistance in concrete track, generally, existing study shows concrete track has 2 time shorter life cycle for rail replacement than ballast track due to abrasion. As a result of domestic concrete track design and operation performance review, concrete track elasticity is lower than track elasticity of ballast track resulting higher damage on rail and tracks. Generally, concrete track has advantage in track elasticity adjustment than ballast track and in case of Europe, in concrete track design, it is recommended to have same or higher performance range of vertical elastic stiffness of ballast track but domestically or internationally review on lateral spring stiffness of track is very minimal. Therefore, through analysis of service line track on site measurement and analysis on performance of maintenance, in this research, dynamic characteristic behaviors of commonly used ballast and concrete track are studied to infer elasticity of service line track and experimentally prove effects of track lateral spring stiffness that influence curved rail damage as well as correlation between track elasticity by track system and rail damage to propose importance of appropriate elastic stiffness level for concrete and ballast track.

  • PDF

A Performance Evaluation of mSE-MMA Adaptive Equalization Algorithm in QAM Signal (QAM 신호에서 mSE-MMA 적응 등화 알고리즘의 성능 평가)

  • Lim, Seung-Gag
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.1
    • /
    • pp.95-100
    • /
    • 2020
  • This paper related with the performance evaluation of mSE-MMA (modified Signed Error-Multi Modulus Algorithm) adaptive equalization algorithm which is possible to reduce the distortion that is occurs in nonlinear communication channel like as additive noise, intersymbol interference and fading. The SE-MMA algorithm are emerged in order to reducing the computational load compared to the presently MMA algorithm, it has the degraded equalization performance by this. In order to improve the performance degradation of SE-MMA, the mSE-MMA controls the step size according to the existence of arbitrary radius circle of equalizer output is centered at transmitted symbol point. The performance of proposed mSE-MMA algorithm were compared to present SE-MMA using the same channel and noise environment by computer simulation. For this, the recoverd signal constellation which is the output of equalizer, residual isi and MD (Maximum Distortion), MSE learning curve which is represents the convergence performance and SER which is represents the roburstness of noise were used as performance index. As a result of simulation, the mSE-MMA has more superior to the SE-MMA in every performance index, and was confirmed that mSE-MMA has roburstness to the noise in the SER performance than SE-MMA especially.

A Linear Change of Leakage Current and Insulation Resistance of 22 kV Cables (22 kV 케이블의 누설전류 및 절연저항의 선형적 변화)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.3
    • /
    • pp.169-173
    • /
    • 2015
  • This study is to predict the life exponent by measuring, over 7 years, the insulation resistance of high-voltage cables in 22 kV operation for 13 years. We found out the lifetime index in order to determine the time-dependent trend of deteriorating performance of power cables. The insulation resistances decreased according to elapsed time. We found that: the initial measurements of the cable systems were in agreement with the deterioration properties of the Arrhenius Law. By analyzing the life curve of the cable system, we also verified that the value of the life exponent (n) in the v-t characteristics defined by Weibull distribution has values from 10 to 11. When designing the cable system, the initial value of life exponent was chosen as 9 without any grounding. We have verified that the theoretical grounding based on the design safety of n=9 was actually the best one available. In the short term, we apply our research result to the diagnosis and evaluation of the power cables. In the long run, however, we plan to reduce the cost of the installation and management of cable systems in operation at power stations.

Remaining Useful Life Prediction of Li-Ion Battery Based on Charge Voltage Characteristics (충전 전압 특성을 이용한 리튬 이온 배터리의 잔존 수명 예측)

  • Sim, Seong Heum;Gang, Jin Hyuk;An, Dawn;Kim, Sun Il;Kim, Jin Young;Choi, Joo Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.4
    • /
    • pp.313-322
    • /
    • 2013
  • Batteries, which are being used as energy sources in various applications, tend to degrade, and their capacity declines with repeated charging and discharging cycles. A battery is considered to fail when it reaches 80% of its initial capacity. To predict this, prognosis techniques are attracting attention in recent years in the battery community. In this study, a method is proposed for estimating the battery health and predicting its remaining useful life (RUL) based on the slope of the charge voltage curve. During this process, a Bayesian framework is employed to manage various uncertainties, and a Particle Filter (PF) algorithm is applied to estimate the degradation of the model parameters and to predict the RUL in the form of a probability distribution. Two sets of test data-one from the NASA Ames Research Center and another from our own experiment-for an Li-ion battery are used for illustrating this technique. As a result of the study, it is concluded that the slope can be a good indicator of the battery health and PF is a useful tool for the reliable prediction of RUL.

Long-term corrosion-resistance of an uncoated weathering steel and its on-line and in-situ measurements (무도장 내후성강의 장기 내식성 및 그 현장즉시측정법)

  • Park, Jeong Real;Kim, Kyoo Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.4 s.71
    • /
    • pp.415-423
    • /
    • 2004
  • To investigate the long-term corrosion resistance of an uncoated weathering steel, an important outdoor constructional steel material, skyward surfaces of the weathering steel and a control steel initially exposed to rural and industrial atmospheres for 9 years were electrochemically tested in neutral artificial rain in terms of electrochemical potentials, impedances, and anodic potentiodynamic polarization curves. Their results were then discussed. A quite passive and stable rust layer to the artificial rain was well formed on the skyward surface of the weathering steel exposed to the industrial and rural atmospheres, and its corrosion rate in the artificial rain was measured to be about a low $3{{\mu}m}/y$. Continuous immersion of all the weathered surfaces in the artificial rain revealed the gradual degradation of the weathered corrosion layers on the steel, resulting in a cathodically controlled corrosion of the substrate steel by the electrochemical measurements. Alloy components of the weathering steel were found to retard the degradation of the weathered corrosion layers on the steel in the artificial rain. For better corrosion evaluation of the weathering steel, more electrochemical measurements of surfaces that have been exposed for more than 9 years to more closely simulated atmospheric waters are needed. These measurements are almost non-destructive and can provide online and in situ information on the corrosion rate, the development of corrosion and the conditions of rust layers on any interested surface and at any exposure time of the steel, so they can be effectively applicable to the corrosion evaluation of steel structures such as bridges, towers, and architectures by forming an electrochemical cell on an interested structural surface and by using a portable electrochemical instrument.

Evaluation of pore water pressure on the lining during tunnel operation (운영 중 터널에 작용하는 간극수압 평가기법)

  • Shin, Jong-Ho;Shin, Yong-Suk;Choi, Kyu-Cheol
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.10 no.4
    • /
    • pp.361-369
    • /
    • 2008
  • Control of ground water is one of the most important factors for long-term operation of tunnel because most of tunnel is located in the ground. In case of leakage tunnel, there is no pore water pressure on the lining when the drainage system is properly working. After long-term operation, however, the pore water pressure can be developed on the lining due to the deterioration of the drainage system. The increased pore water pressure on the lining is termed here as 'residual pore water pressure'. Residual pore water pressure can be measured by piezometer, but it is generally not allowed because of damages of drainage system. Therefore, an indirect and nondestructive method is required for evaluating the residual pore water pressure. Moreover, understanding of pore water pressure is needed during healthy operation of the lining. In this study, a new method for evaluation of pore water pressure on the lining during operation is proposed using theoretical and numerical analysis. It is shown that the method is particularly useful for stability investigation of pore water pressure on the lining during operation using theoretical analysis with normalized pore water pressure curve.

  • PDF

Isolation and characterization of microorganisms biological damage of Dongchundang (동춘당 생물학적 가해 미생물의 분리 및 특성)

  • Lee, Jeung-Min;Kim, Young-Hee;Hong, Jin-Young;Jo, Chang-Wook;Kim, Soo Ji;Seo, Min Seok
    • 보존과학연구
    • /
    • s.35
    • /
    • pp.111-119
    • /
    • 2014
  • Microorganisms were isolated from Dongchundang(wooden cultural heritage) with PDA medium culture. Nineteen species shows the cellulolytic activity. Methylobacterium sp. was the most active in cellulose degradation. The growth curve and pH were measured during incubation of the microorganism for 72 hours. The pH was increased with the increasing of microbial growth. The degree of cellulose degradation was determined with the amount of reducing sugar by use of dinitrosalicylic acid (DNS) method. The amount of reducing sugar was decreased after 45 hours. As a results, It should suggested that wood component were deteriorated by Methylobacterium sp..

  • PDF