• Title/Summary/Keyword: 열추가

Search Result 838, Processing Time 0.025 seconds

Gastric Dilatation and Volvulus in Shih-tzu (시츄에서 발견된 위확대염전)

  • Moon, Joon Ho;Kim, Hyun Ah;Ryu, Minok;Jang, Min;Ji, Seoyeon;Lee, Inhyung;Yoon, Junghee;Choi, Mincheol;Youn, Hwayoung;Lee, Byeong Chun;Jang, Goo
    • Journal of Veterinary Clinics
    • /
    • v.32 no.3
    • /
    • pp.255-258
    • /
    • 2015
  • Gastric dilatation and volvulus (GDV) is an acute and life-threatening disease most commonly affecting large- and giant-breed dogs. However a 17-year-old Shih-tzu (4 kg, spayed female) was hospitalized for acute GDV. Repeated unproductive retching, lethargy, and excessively enlarged abdomen were observed. Physical examination indicated that the patient had suffered from hypothermia ($36.5^{\circ}C$), tachycardia (240 bpm), slowed capillary refill time (> 2 sec.), and pale mucous membrane. Grade III murmur with normal lung sound was auscultated. Abdominal palpation revealed that tympanic regions existed in both the left and right sides. Systolic blood pressure decreased gradually from 220 to 40 mmHg within 4 hours. In blood analysis, slight azotemia was observed by blood urea nitrogen (BUN; 29.1 mg/dl) and creatinine (1.6 mg/dl). Blood lactate concentration (8.13 mmol/l) was severely elevated. Additionally, dilatation and volvulus of the stomach was observed by radiograph. Supportive oxygen, heat, fluid, and drugs were administered with gastric decompressions (e.g., gastrocentesis and nasogastric tube). However the patient entered into comatose status with uncontrollable systolic blood pressure, despite the administration of dobutamine intravenously. The case was closed by euthanasia, considering welfare and age. We finally diagnosed the patient as a GDV, thus this is the first GDV case report in small-breed dog such as Shih-tzu.

A Study on the Evaluation of Patient Dose in Interventional Radiology (중재적방사선검사에서 환자 피폭선량에 관한 연구)

  • Park, Hyung-Sin;Lim, Cheong-Hwan;Kang, Byung-Sam;You, In-Gyu;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.299-308
    • /
    • 2012
  • To perform patient dose surveys in major interventional radiography procedures as a mean of inter-institutional comparison and of establishing reference dose levels with the ultimate goal of optimizing patient doses in the field of interventional radiography. We reviewed international patient dose survey data in the literature and measured patient dose in major interventional radiography procedures (TACE, AVF, PTBD, TFCA, GDC embolization). ESD(Entrance Skin Dose) was measured using TLD chips attached to the patient skin and ED(Effective Dose) was calculated using angiography unit-derived DAP. A survey of patient dose in interventional radiography procedures were also performed with a questionnaire for interventional radiologists and we proposed a guideline for optimizing patient doses in the field of interventional radiology. The patient dose survey data in interventional radiography procedures were very rare in literature compared with those in diagnostic radiography procedures. In TACE, the mean ED was 25.43 mSv and the mean ESD was 511.75 mGy. The mean ED of TACE was not high, but the cumulative dose should be checked, due to longer procedure TACE. In TFCA, the mean ED was 22.6 mSv and it was relatively high compared with data of other countries. In GDC embolization, the mean ED was not available, because GDC embolization was performed with old Image-Intensifier-type unit and there has no unit-installed ionization chamber. Also, the mean ESD of GDC embolization was up to 2,264 mGy and further studies are needed to calculate the net ED of GDC embolization. Patient dose occurred during interventional radiography procedures are high related with the difficulty of the procedure, fluoroscopy time, the number of angiographies and the treatment protocol. Therefore, continuous education and efforts should be made to optimize the patient dose in the field of interventional radiology.

Construction and estimation of soil moisture site with FDR and COSMIC-ray (SM-FC) sensors for calibration/validation of satellite-based and COSMIC-ray soil moisture products in Sungkyunkwan university, South Korea (위성 토양수분 데이터 및 COSMIC-ray 데이터 보정/검증을 위한 성균관대학교 내 FDR 센서 토양수분 측정 연구(SM-FC) 및 데이터 분석)

  • Kim, Hyunglok;Sunwoo, Wooyeon;Kim, Seongkyun;Choi, Minha
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.2
    • /
    • pp.133-144
    • /
    • 2016
  • In this study, Frequency Domain Reflectometry (FDR) and COSMIC-ray soil moisture (SM) stations were installed at Sungkyunkwan University in Suwon, South Korea. To provide reliable information about SM, soil property test, time series analysis of measured soil moisture, and comparison of measured SM with satellite-based SM product are conducted. In 2014, six FDR stations were set up for obtaining SM. Each of the stations had four FDR sensors with soil depth from 5 cm to 40 cm at 5~10 cm different intervals. The result showed that study region had heterogeneous soil layer properties such as sand and loamy sand. The measured SM data showed strong coupling with precipitation. Furthermore, they had a high correlation coefficient and a low root mean square deviation (RMSD) as compared to the satellite-based SM products. After verifying the accuracy of the data in 2014, four FDR stations and one COSMIC-ray station were additionally installed to establish the Soil Moisture site with FDR and COSMIC-ray, called SM-FC. COSMIC-ray-based SM had a high correlation coefficient of 0.95 compared with mean SM of FDR stations. From these results, the SM-FC will give a valuable insight for researchers into investigate satellite- and model-based SM validation study in South Korea.

Differences in Yields, Antioxidant Compounds, and Antioxidant Activity of Ethanolic Extracts among 11 Adzuki Bean Cultivars (Vigna angularis L.) Cultivated on a Somewhat Poorly Drained Paddy Field (논 재배 팥 품종별 수량구성요소 및 에탄올 추출물의 항산화 성분 비교)

  • Chun, Hyen Chung;Jung, Ki Yuol;Choi, Young Dae;Lee, Sanghun;Song, Seok bo;Ko, Jee Yeon;Choi, Ji Myung;Jang, Yun Woo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.62 no.3
    • /
    • pp.203-213
    • /
    • 2017
  • This study investigated the changes in yields, antioxidant compounds, and antioxidant activities among 11 adzuki bean cultivars cultivated in a paddy field with somewhat poorly drained soil. The adzuki bean cultivars were cultivated in the paddy field from 2015 to 2016 in Milyang, Gyeongsangnam, Korea. Average soil moisture content was 16.5% in 2015 and 31.0% in 2016 at the experimental site during adzuki bean cultivation. As the soil moisture content increased, most of the adzuki bean cultivars showed deceases in stem height, first setting pod node, number of pods, 100 seed weight, and yield. Chungju-pat produced the greatest yields among the 11 cultivars in 2015 and 2016, whereas Hongeon had the smallest yields. Adzuki bean yields after paddy field cultivation was lower for all cultivars than for adzuki bean yields from the same cultivars after upland field cultivation. Chungju-pat and Chilbo-pat showed the smallest decreases in yields after paddy field cultivation, whereas Hongeon and Kumsil showed the greatest yield reductions. There were no significant differences in proximate composition. Some mineral components ($P_2O_5$, Ca, and Mg) were statistically different across cultivars. Chungju-pat had the highest Ca and Mg contents, but antioxidant components (polyphenol and flavonoids) and antioxidant activities (ABTS and DPPH) were highest in Saegil and lowest in Jungbu-pat. PCA and clustering analyses, based on the growth, yield, and antioxidant component measurements, performed to identify which variables contributed the most to separating adzuki bean cultivars or to grouping cultivars with similar characteristics. These analyses showed that the antioxidant components and antioxidant activities had the most influence on grouping cultivars together. Among the 11 cultivars, Saegil was statistically different from the other cultivars, but the other 10 cultivars were not significantly different under paddy field cultivation. Soil moisture content affected adzuki bean yield and antioxidant component contents. An increase in soil moisture led to a decrease in yield, but an increase in antioxidant components. These results provide information that will improve the selection of an appropriate adzuki bean cultivar for use in paddy fields.

Quality characteristics and preparing of solid starter using fungal strains for Takju (탁주용 곰팡이 고체종국 제조 및 품질 특성)

  • Baek, Chang-Ho;Baek, Seong Yeol;Mun, Ji-Young;Choi, Han-Seok;Kang, Ji-Eun;Jung, Seok-Tae;Yeo, Soo-Hwan
    • Food Science and Preservation
    • /
    • v.23 no.6
    • /
    • pp.797-803
    • /
    • 2016
  • In this study, we investigated the effect of fermentation conditions on the amylolytic and proteolytic activities of Aspergillus luchuensis strain 74-5 and Aspergillus oryzae strain 75-2, which are used in the preparation of the starter culture, for Takju (Korean traditional rice wine). The starter culture was optimized using different conditions, such as inoculum size, inoculation temperature, and incubation time. The enzyme activities under each condition were measured. In the A. luchuensis strain 74-5 starter culture, the ${\alpha}-amylase$ and glucoamylase activities increased, however the activity of acidic protease decreased as the diluent to starter culture ratio increased. In the A. oryzae 75-2 starter culture, all enzyme activities were maintained at a higher level even at 5% inoculation ratio. Higher enzyme activities were observed in the middle range of inoculation temperature (35, $40^{\circ}C$), than in the lower range (20, $30^{\circ}C$). Enzyme activity in the starter culture varied with incubation time, however it was the highest at 144 and 120 hr, respectively, for A. luchuensis strain 74-5 and A. oryzae strain 75-2. The spore count of the starter culture was approximately $2{\times}10^7$ during fermentation, out of which contamination by aerobic bacteria was about $3{\times}10^3$. The results suggested that the starter culture of each strain could be used as an inoculum for fermentation. However, we needs to conduct further research for the selection of suitable diluting agents as well as drying methods to reduce the contamination by aerobic bacteria, while retaining the enzyme activity.

Preparation and Quality Characterization of Apple Jam with Rosa rugosa Thunb. Fruit (해당화 열매 첨가 사과잼 제조 및 품질 특성)

  • Kim, Mi-Hyun;Kim, Myung-Hee;Yun, Sun-Ju;Lee, Byung-Yong;Lee, Chang-Won;Kim, Bo-Ae;Jang, Ki-Hyo;Lee, Jae-Cheol;Surh, Jeong-Hee
    • Korean journal of food and cookery science
    • /
    • v.26 no.4
    • /
    • pp.367-380
    • /
    • 2010
  • Various contents of Rosa rugosa Thunb. fruit(0, 10, 20%), which is grown along the seashore of Gangwon province, were applied to apple jams having different sugar concentrations(20, 40, 60%). The resulting jams were analyzed using a sensory scoring test as well as a response surface methodology to identify the optimum conditions for the preparation of high-preference apple jams. The sensory properties based on sense of sight, smell and taste appeared to be linked to the sugar contents. It could be attributed to the presence of flavor compounds and pigments generated from the caramelization of sugar molecules during heat processing. On the other hand, rheological properties such as viscosity and spreadability were associated with Rosa rugosa fruit content, which was also verified by textural analysis of the jams. As the contents of Rosa rugosa increased, the hardness, gumminess, and chewiness of the jams decreased, which eventually might have contributed to the less thick and thus more spreadable sensory characteristics. Sensory evaluation revealed that apple jams were preferred when prepared with $\leq$10% of Rosa rugosa fruit and $\geq$55% of sugar contents. In particular, apple jams containing 10% Rosa rugosa and 60% sugar showed better mechanical qualities as well as higher sensory preference among 10 jams formulated using central composite design.

Effect of Inhomogeneity correction for lung volume model in TPS (Lnug Volume을 모델로 한 방사선치료계획 시 불균질 조직 보정에 따른 효과)

  • Chung SeYoung;Lee SangRok;Kim YoungBum;Kwon YoungHo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.57-65
    • /
    • 2004
  • Introduction : The phantom that includes high density materials such as steel was custom-made to fix lung and bone in order to evaluation inhomogeneity correction at the time of conducting radiation therapy to treat lung cancer. Using this, values resulting from the inhomogeneous correction algorithm are compared on the 2 and 3 dimensional radiation therapy planning systems. Moreover, change in dose calculation was evaluated according to inhomogeneous by comparing with the actual measurement. Materials and Methods : As for the image acquisition, inhomogeneous correction phantom(Pig's vertebra, steel(8.21g/cm3), cork(0.23 g/cm3)) that was custom-made and the CT(Volume zoom, Siemens, Germany) were used. As for the radiation therapy planning system, Marks Plan(2D) and XiO(CMS, USA, 3D) were used. To compare with the measurement value, linear accelerator(CL/1800, Varian, USA) and ion chamber were used. Image, obtained from the CT was used to obtain point dose and dose distribution from the region of interest (ROI) while on the radiation therapy planning device. After measurement was conducted under the same conditions, value on the treatment planning device and measured value were subjected to comparison and analysis. And difference between the resulting for the evaluation on the use (or non-use) of inhomogeneity correction algorithm, and diverse inhomogeneity correction algorithm that is included in the radiation therapy planning device was compared as well. Results : As result of comparing the results of measurement value on the region of interest within the inhomogeneity correction phantom and the value that resulted from the homogeneous and inhomogeneous correction, gained from the therapy planning device, margin of error of the measurement value and inhomogeneous correction value at the location 1 of the lung showed $0.8\%$ on 2D and $0.5\%$ on 3D. Margin of error of the measurement value and inhomogeneous correction value at the location 1 of the steel showed $12\%$ on 2D and $5\%$ on 3D, however, it is possible to see that the value that is not correction and the margin of error of the measurement value stand at $16\%$ and $14\%$, respectively. Moreover, values of the 3D showed lower margin of error compared to 2D. Conclusion : Revision according to the density of tissue must be executed during radiation therapy planning. To ensure a more accurate planning, use of 3D planning system is recommended more so than the 2D Planning system to ensure a more accurate revision on the therapy plan. Moreover, 3D Planning system needs to select and use the most accurate and appropriate inhomogeneous correction algorithm through actual measurement. In addition, comparison and analysis through TLD or film dosimetry are needed.

  • PDF

Real-time Nutrient Monitoring of Hydroponic Solutions Using an Ion-selective Electrode-based Embedded System (ISE 기반의 임베디드 시스템을 이용한 실시간 수경재배 양액 모니터링)

  • Han, Hee-Jo;Kim, Hak-Jin;Jung, Dae-Hyun;Cho, Woo-Jae;Cho, Yeong-Yeol;Lee, Gong-In
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.141-152
    • /
    • 2020
  • The rapid on-site measurement of hydroponic nutrients allows for the more efficient use of crop fertilizers. This paper reports on the development of an embedded on-site system consisting of multiple ion-selective electrodes (ISEs) for the real-time measurement of the concentrations of macronutrients in hydroponic solutions. The system included a combination of PVC ISEs for the detection of NO3, K, and Ca ions, a cobalt-electrode for the detection of H2PO4, a double-junction reference electrode, a solution container, and a sampling system consisting of pumps and valves. An Arduino Due board was used to collect data and to control the volume of the sample. Prior to the measurement of each sample, a two-point normalization method was employed to adjust the sensitivity followed by an offset to minimize potential drift that might occur during continuous measurement. The predictive capabilities of the NO3 and K ISEs based on PVC membranes were satisfactory, producing results that were in close agreement with the results of standard analyzers (R2 = 0.99). Though the Ca ISE fabricated with Ca ionophore II underestimated the Ca concentration by an average of 55%, the strong linear relationship (R2 > 0.84) makes it possible for the embedded system to be used in hydroponic NO3, K, and Ca sensing. The cobalt-rod-based phosphate electrodes exhibited a relatively high error of 24.7±9.26% in the phosphate concentration range of 45 to 155 mg/L compared to standard methods due to inconsistent signal readings between replicates, illustrating the need for further research on the signal conditioning of cobalt electrodes to improve their predictive ability in hydroponic P sensing.

The fracture resistance of heat pressed ceramics with wire reinforcement (금속선 강화에 따른 열 가압 도재의 파절저항)

  • Jo, Deuk-Won;Dong, Jin-Keun;Oh, Sang-Chun;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.191-198
    • /
    • 2009
  • Statement of problem: Ceramics have been important materials for the restoration of teeth. The demands of patients for tooth-colored restorations and the availability of various dental ceramics has driven the increased use of new types of dental ceramic materials. Improved physical properties of theses materials have expanded its use even in posterior crowns and fixed partial dentures. However, ceramic still has limitation such as low loading capability. This is critical for long-span bridge, because bridge is more subject to tensile force. Purpose: The wire reinforced ceramic was designed to increase the fracture resistance of ceramic restoration. The purpose of this study was to evaluate the fracture resistance of wire reinforced ceramic. Material and methods: Heat pressed ceramic(ingot No.200 : IPS Empress 2, Ivoclar Vivadent, Liechtenstein) and Ni-Cr wire(Alfa Aesar, Johnson Matthey Company, USA) of 0.41 mm diameter were used in this study. Five groups of twelve uniform sized ceramic specimens(width 4 mm, thickness 2 mm, length 15 mm) were fabricated. Each group had different wire arrangement. Wireless ceramic was used as control group. The experimental groups were divided according to wire number and position. One, two and three strands of wires were positioned on the longitudinal axis of specimen. In another experimental group, three strands of wires positioned on the longitudinal axis and five strands of wires positioned on the transverse axis. Three-point bending test was done with universal testing machine(Z020, Zwick, Germany) to compare the flexural modulus, flexural strength, strain at fracture and fracture toughness of each group. Fractured ceramic specimens were cross-sectioned with caborundum disc and grinded with sandpaper to observe interface between ceramic and Ni-Cr wire. The interface between ceramic and Ni-Cr wire was analyzed with scanning electron microscope(JSM-6360, JEOL, Japan) under platinum coating. Results: The results obtained were as follows: 1. The average and standard deviation in flexural modulus, flexural strength and fracture toughness showed no statistical differences between control and experimental groups. However, strain was significantly increased in wire inserted ceramics(P<.001). 2. Control group showed wedge fracture aspects across specimen, while experimental groups showed cracks across specimen. 3. Scanning electron microscopic image of cross-sectioned and longitudinally-sectioned specimens showed no gap at the interface between ceramic and Ni-Cr wire. Conclusion: The results of this study showed that wire inserted ceramics have a high strain characteristic. However, wire inserted ceramics was not enough to use at posterior area of mouth in relation to flexural modulus and flexural strength. Therefore, we need further studies.

Policy suggestions to educate and produce outstanding paramedics in Korea (우수한 1급 응급구조사 인력 양성 및 배출을 위한 정책 제안)

  • Choi, Eun-Sook;Koh, Bong-Yeun;Park, Hee-Jin;Kim, Hyo-Sik;Kwon, Hay-Rran;Choi, Hea-Kyung;Lee, Kyoung-Youl;Yun, Jong-Geun;Hong, Sung-Gi;Cho, Keun-Ja
    • The Korean Journal of Emergency Medical Services
    • /
    • v.22 no.1
    • /
    • pp.7-19
    • /
    • 2018
  • Purpose: With the purpose of educating and producing outstanding paramedics by enhancing their competencies, this study aimed to make policy suggestions to re-establish the education system and improve the national examination and the certification scheme. Methods: This study used focus group interviews and questionnaires to collect data. Totally, there were 277 subjects, including experts from the education and field. Data were collected from September 9 to 20, 2016, and analyzed using SPSS 22.0. Results: To strengthen the curriculum of paramedics, this study suggested 27 courses with 94 credits as the standardized curriculum and derived 9 core competencies of paramedics. For the national examination, this study suggested consolidating written test subjects, adding scenario questions to practical tests, and applying critical criteria to simple practical tests that performs a procedure, grading these tests on a pass/fail basis. In addition, this study suggested converting certification into license, reflecting paramedics' healthcare job characteristics. Conclusion: The quality of emergency medical services in Korea will improve when those with core competencies that originated from the standardized curriculum based on the results of this study acquire their certification through the national test scheme, and the certification management system creates a virtuous cycle to further enhance paramedics' professionalism.