Transactions of the Korean Society of Mechanical Engineers B
/
제24권6호
/
pp.870-879
/
2000
An experimental investigation is conducted to improve a slot film cooling system which can be used for the cooling of gas turbine combustor liner. The tangential slots are constructed of discrete holes with different injection types which are the parallel, vertical, and combined to the slot lip. The investigation is focused on the coolant supply systems of normal-, parallel-, and counter-flow paths to the mainstream direction. A naphthalene sublimation technique has been employed to measure the local heat/mass transfer coefficients in a slot with various injection types and coolant feeding directions. The velocity distributions at the exit of slot lip for the parallel and vertical injection types are fairly uniform with mild periodical patterns with respect to the hole positions. However, the combined injection type increases the nonuniformity of flow distribution with the period equaling twice that of hole-to-hole pitch due to splitting and merging of the ejected flows. The secondary flow at the lip exit has uniform velocity distributions for the parallel and vertical injection types, which are similar to the results of a two-dimensional slot injection. In the results of local heat/mass transfer coefficient, the best cooling performance inside the slot is obtained with the vertical injection type among the three different injection types due to the effect of jet impingement. The lateral distributions of Sh with the parallel- and counter-flow paths are more uniform than the normal flow path. The averaged Sh with the injection holes are $2{\sim}5$ times higher than that of a smooth two-dimensional slot path.
Transactions of the Korean Society of Mechanical Engineers B
/
제35권9호
/
pp.923-932
/
2011
Because of the instability of a flow pattern in the inlet transition square duct (hereinafter referred to as "transition duct") of a heat recovery steam generator (hereinafter referred to as "HRSG") in a combined cycle power plant, the Reynolds number in the first row of a tube bank is differs sharply from that in the sectional area of the transition duct. This causes differences in the heat flux in each tube in the tube bank. The computational fluid dynamics (CFD) predictions provide three-dimensional results for velocity, temperature, and other flow parameters over the entire domain of the duct and HRSG. A renormalization group theory (RNG) based k-${\epsilon}$�� turbulent model is used for obtaining the results cited in this study. A porous media option is used for modeling the tube banks and the number of transfer units method is used for determining the heat transfer characteristics. This study describes a comparison between the numerical simulation results and actual design output.
The purpose of this study is to obtain basic data on the optimization of firing process conditions for enamel coating in chemical heat exchanger. The method of increasing the firing temperature in order to apply enamel coating to shell & tube type heat exchanger was examined. The temperature distribution of the heat exchanger in the firing kiln was numerically calculated using a commercial CFD program. The structural safety of the heat exchanger was confirmed by thermal stress analysis using the FSI method. Numerical analysis and experimental results show that there is a problem of safety due to temperature difference when the heat exchanger at room temperature is directly put into a firing kiln at 860℃. Therefore, a preheating process is need to reduce the temperature difference. As in Case2 with fewer firing steps, the first stage preheating temperature of 445℃and the second stage firing temperature of 860 ℃are considered to be most suitable.
Journal of the Korea Academia-Industrial cooperation Society
/
제16권11호
/
pp.7773-7780
/
2015
Analysis of existing kettle and its heating system has been the topic for localization technology development. Test pieces are made, polished and etched for existing kettle analysis. Surface of test pieces is observed using SEM, the kettle is verified to be made by deep drawing process from Ferrite-Perlite material. The kettle is also identified to be plated $16{\sim}49{\mu}m$ of thickness with Nickel(16%). Also heat transfer characteristics based on hot wire arrangement is investigated and optimal hot wire system is developed. Developed control system detects overheating and stops the whole system on the long operating time. Developed kettle takes the performance evaluation test for volume expansion and satisfied for standard 'KS G3602'.
Proceedings of the Korean Vacuum Society Conference
/
한국진공학회 2010년도 제39회 하계학술대회 초록집
/
pp.116-116
/
2010
진공 chamber에서 방전된 plasma 내부를 외부 view port를 통하여 확인하는 것은 극히 제한적이며 leak의 확률을 높이고 plasma의 균일한 방전을 방해한다. 이를 개선하기 위하여 내장형 무선 카메라를 chamber 내부에 위치한 후 고진공 영역에서 촬영을 시도하였으나 일반적인 CCD 카메라로는 촬영할 수 없다. 고진공 영역에서 카메라 내부온도의 급격한 상승이 원인으로 밝혀졌고 적정온도인 $45^{\circ}C$를 초과하여 최대 $96^{\circ}C$까지 4 min 이내에 상승함을 IR camera로 확인할 수 있었으며 이 때 카메라가 작동하지 않았다. 또한 카메라를 고진공 영역에서 촬영 및 녹화하기 위해서는 $46^{\circ}C$의 온도를 낮추어야 함을 진공해제 이후 내부온도가 $50^{\circ}C$로 감소하면서 내장형 무선 카메라가 다시 작동함으로 인해 알 수 있었다. 본 연구에서는 이를 해결하기 위하여 내장형 무선 카메라에 AM 변조 방식의 311 MHz RF remote controller를 장착하여 외부에서 선택적으로 ON/OFF 할 수 있도록 개조하였고 10 L chamber에서 150 L/sec TMP를 이용하여 10-6 Torr의 압력에서 성공적으로 녹화 및 촬영하였다. 또한 내장형 무선 카메라 내부의 반도체 회로 규격 및 발열량과 heat sink의 규격 (열전도도, 복사율)을 추가로 조사하였다. 분자유동 영역에서 열전달은 복사에 의한 영향이 대부분이므로 내장형 무선 카메라 내부 온도를 감소시켜 카메라의 작동 시간을 연장하기 위하여 내부 회로에 emissivity가 높고 전기전도도가 낮아 회로에 영향이 없는 박막을 회로에 증착시키는 추후의 연구가 필요하다.
Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
/
한국윤활학회 1988년도 제7회 학술강연회초록집
/
pp.1-11
/
1988
Tribology라는 용어는 마찰, 마모, 윤활의 과학, 기술을 한마디로 나타내는 말이다. 우리들의 일상생홀, 산업활동, 특히 소성가공에서 Tribology의 역활의 중요성은 새삼 강조할 필요가 없다. 소성가공에서 가공방식, 공구, 소재, 온도, 속도에는 무수한 조합이 있고, 마찰-마모-윤활의 상효연관 또한 복잡하다. 역학, 열전달, 물리학, 화학적과정이 동시에 상호작용을 하면서 진행하는 이 시스템에서는 크게는 공작기계로부터 작게는 micron정도의 표면과 윤활막 뿐만 아니라, 경우에 따라서는 ${\AA}$ 정도의 정체불명체가 결정적인 역활을 한다. 본 고에서는 냉간압연, 단조, 인발등에 Tribology를 응용하는 입장에서 Tribology system의 일부를 공구와 재료의 윤활제를 개재한 micro 접촉상황을 중심으로 분류정리하고, 이것과 공업적 소성가공에서 공구 - 재료접촉면현상과 그 연계를 가능한 한 이해하기 쉽게 서술하였다. 이를 통하여 소성가공기술자 및 연구자가 소성가공의 목적을 달성하는 가운데, Tribology 적으로 양호한 결과를 경제적으로 얻고자하는 시행, 개발, 연구에 대해 도움이 되고자 한다.
Journal of Advanced Marine Engineering and Technology
/
제28권3호
/
pp.538-550
/
2004
The convection heat transfer coefficients on the top surface of a large liquid petroleum liquid injection(LPLi) engine piston with the oil gallery are analyzed by solving an inverse thermal conduction problem. The heat transfer coefficients are numerically found so that the difference between analyzed temperatures from the finite element method and measured temperatures is minimized. Using the resulting heat transfer coefficients as the boundary condition, temperature of a large LPLi engine piston is analyzed. With varying cooling water temperature, temperature, stress, and thermal expansion of the piston are analyzed and evaluated.
직접 접촉식 교환장치(이하 직접 교환기라 함)에서 액체의 유통형태의 선택은 매우 다양하며 전달계수 역시 개별적인 상황이나 충전물의 종류에 따라서 달라지므로 일률적으로 제시되지 못 하고 있다. 많은 경우 실험을 통하여 열전달 또는 물질전달계수를 측정하게 되나 개수로, 자유 낙하액체막, 액체분류와 같이 이상화가 가능한 경우, 이러한 전달계수를 구하기 위하여 이론적 또는 반실험적인 해석을 수행하기도 한다. 수많은 관련 연구결과들은 층류유동에 관한 것과 난류유동의 경우로 구분되고(예상되듯이 대부분의 직접교환기의 유통영역은 난류쪽이다), 난류 유통의 해석은 다시 표면갱신이론(surface renewal model), 와류확산계수모델(eddy diffusivity model-macroscopic), 미분형와류모델(differential eddy diffusivity model)로 대별된다. 여기서는 수많은 교환기형태의 자료정리보다 상기와 같이 대별된 액체측 유동영역별로 전달현상해석의 방법을 간단히 정리하고자 한다.
In a gas engine based cogeneration system, heat is recovered from two parts, which are jacket water and exhaust gas. The heat from the jacket water is often recovered by a plate type heat exchanger and used for the room heating and/or hot water supply. Depending on the operating conditions of engine and heat recovery system, there should be imbalance in the flow rate and supply pressure between engine and heat recovery side of the heat exchanger. The imbalance cause the deformation of the plate, which affects the pressure drop characteristics. In the present study, the pressure drop inside the heat exchanger has been investigated in a 1/5 scaled test rig and compare with the experimental correlations, which are used for the design.
발전소 복수기의 열전달 표면에 형성되는 불순물의 fouling factor와 튜브내면에 부착되는 피막의 두께변화를 측정하여 복수기 관리에 관한 지침을 제시하고자 모델복수기를 이용하여 60일간 현장실험을 실시하였다. 복수기의 fouling factor는 시험 후 약 40일 이후부터 큰 폭으로 증가하였다. 발전용 복수기의 관청결도가 85-90%로 설계되므로 설계치를 유지하기 위해서는 약 40일 마다 복수기튜브를 세정하여 관청결도를 향상시켜야 할 것으로 판단되었다. 또한 동합금 재질을 사용하는 복수기튜브는 설치 후 보호피막이 형성되는 초기 30일 동안의 방식운전이 복수기튜브 건전성 확보에 중요한 인자임을 유추할 수 있었다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.