• Title/Summary/Keyword: 열저장성능

Search Result 16, Processing Time 0.021 seconds

Effect of pyrolysis temperature on the thermal energy storage performance of sesame plant biochar (참깨 바이오차의 열분해 온도가 열에너지 저장 성능에 미치는 영향 평가)

  • Soumen Mandal;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.65-66
    • /
    • 2023
  • This study is aimed to understand the effect of pyrolysis temperature on the biochar synthesis for shape stabilizing the Lauric acid (LA). Three different temperatures (350, 500, and 650 ℃) have been chosen with a soaking time of 1h for synthesizing biochars form sesame plants (SP). The structural characterizations indicate the formation of amorphous biochar at 350 ℃ whereas, a stain of graphene formation has been observed for the biochar synthesized at 500 ℃. Formation of a substantial amount of graphene has been found for the sample, synthesized at 650 ℃. Energy storage performances of the PCMs which are shape stabilized by these three biochars have been discussed in this paper.

  • PDF

A Reaserch on the Performance Verification of Energy Storage Mortar Enhanced in Thermal Efficiency and Strength by Applying Microencapsulated Phase Change Materials and Nanomaterials (마이크로캡슐로 코팅한 상변화 물질과 나노소재를 적용한 고효율 열저장 시멘트 복합체 성능 검증 연구)

  • Ahn, Jun Hyuk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.44 no.4
    • /
    • pp.433-441
    • /
    • 2024
  • This study aims to prevent freezing of existing domestic buildings by developing an energy storage mortar with increased energy efficiency that can reduce the increase in carbon emissions and maintenance costs due to external energy use due to heat wires in civil engineering and buildings with embedded heat wires. I suggest. Research has focused on incorporating phase change materials (PCMs) into common cement composites to provide latent heat performance. However, concrete mixed with phase change materials shows problems such as leakage of phase change materials, decreased strength, and insufficient thermal performance. To overcome this problem, we encapsulate phase change materials using microcapsules and mix them into cement composites to minimize strength loss and leakage, and use multi-walled carbon nanotubes and silica fume to minimize the strength reduction of concrete. A heat storage cement composite was developed. When high-efficiency heat storage cement was used as a replacement for ordinary cement composite in an environment where heat wires were buried, the effect was shown to reduce energy by about 42 %, and compared to a cement composite containing only PCM, the compressive strength and bending strength were 18 % and 23 %, respectively. was improved and its effectiveness was proven.

Numerical Analysis on the Performance for Automobile Heat Storage System Using Phase Change Materical (상변화물질을 이용한 자동차용 열저장 시스템의 성능을 위한 수치 해석)

  • 이관수;김혁제;백창인;송영길;한창섭;김등진
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.3
    • /
    • pp.187-198
    • /
    • 1996
  • In this study, the performance of an automobile heat storage system using PCM is numerically simulated. For the analysis of system performance. The phase-change of the PCM and the transient forced convective heat transfer for the HTF are considered simultaneously as a conjugate problem. The phase-change behavior is effectively analyzed using a concept of thermal resistance. From the correlations of phase change rate and heat transfer due to the variations of flow rate of HTF around PCM, the automobile heat storage system performance is predicted. The present results amy be used as the fundamental information for the design of automobile heat storage system.

  • PDF

Guidelines for Designing the Shape and Layout of Thermal Energy Storage (TES) Rock Caverns (열에너지 저장 암반공동의 형상 및 레이아웃 설계 가이드라인)

  • Park, Dohyun;Park, Eui-Seob
    • Tunnel and Underground Space
    • /
    • v.25 no.2
    • /
    • pp.115-124
    • /
    • 2015
  • Thermal energy storage (TES) is a technology that stores surplus thermal energy at high or low temperatures for later use when the customer needs it, not just when it is available. TES systems can help balance energy demand and supply and thus improve the overall efficiency of energy systems. Furthermore, the conversion and storage of intermittent renewable resources in the form of thermal energy can help increase the share of renewable resources in the energy mix which refers to the distribution of energy consumption from different sources, and to achieve this, it is essential to combine renewable resources with TES systems. Underground TES using rock caverns, known as cavern thermal energy storage (CTES), is a viable option for large-scale, long-term TES utilization although its applications are limited because of the high construction costs. Furthermore, the heat loss in CTES can significantly be reduced due to the heating of the surrounding rock occurred during long-term TES, which is a distinctive advantage over aboveground TES, in which the heat loss to the surroundings is significantly influenced by climate conditions. In this paper, we introduced important factors that should be considered in the shape and multiple layout design of TES caverns, and proposed guidelines for storage space design.

Cooling Characteristics of Refrigerated Vehicles with Heat Storage Materials in Thermobank (냉동탑차의 Thermobank 열저장 매체에 따른 냉각성능 비교)

  • Mun, Je-Cheol;Choi, Kwang-Il;Oh, Jong-Taek;Kim, Jai-Hoon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.810-814
    • /
    • 2009
  • A experimental study of a high efficiency transport refrigeration system for sliced-raw fish transportation is presented in this paper. The refrigeration system, that is powered by the car engine, is equipped with heat storage for reverse cycle-hot gas defrost; the stored heat is used during defrost cycle of the system. The heat storage has size $400(L){\times}350(W){\times}250(H)\;mm$ and made of fin-tube heat exchanger. System performance and container operating conditions are experimentally investigated and analyzed under cooling and defrosting conditions with heat storage materials. The water is faster about 30% than paraffin in cooling-down time of heat storage materials with load and unload.

  • PDF

A Study of Heat Transfer during Freezing Process of Water in a Vertical Cylinder. (수직 원통형 축열조내 물의 응고 과정시 열전달에 관한 실험적 연구(작동 유체의 유동방향에 따른 열저장 성능 비교))

  • Heo, Gyeong;Kim, Young-Ki;Kim, Young-Jung;Kim, Jun-Geun;Lim, Jang-Sun
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.223-229
    • /
    • 1995
  • Heat transfer phenomena during freezing process of the water in a vertical cylinder were experimentally studied. Purified water was inserted into the vertical cylinder Experiment was performed with two conditions ; the inlet temperature of the working fluid was maintained to be -1$0^{\circ}C$ and the direction of the working fluid was to be upward or downward. Both the mean temperature of the liquid and temperature difference of cylinder tube wall in the upward were lower than those in the downward. In addition, shape of ice layer in the upward was more uniform than that in the downward. Finally, time-varying total heat energy stored in the water in the upward was higher than that in the downward.

  • PDF

An Experimental Study on the Evaluation of Thermal Performance of Floor mortar with PCM (PCM을 혼입한 방통 모르타르의 열적 성능 평가에 관한 실험적 연구)

  • Kim, Bo-Hyun;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.5-6
    • /
    • 2011
  • CO2 reduction is the most urgent issue the world is facing. So, there should be a measure to reduce the CO2 emission in construction industry which has more released CO2 gas than other industries. CO2 emission of building depend on using energy. Then efficient energy use process working efficiently at CO2 reduction. Therefore In this study, author find the technical possibility of saving the building energy using the PCM which is able to control heat, storage heat and potential heat. So, it considered that apply to floor heating type which is major heating system of living space in Korea. And evaluate the Using possibility.

  • PDF

The Properties of Concrete with Lightweight Aggregate Impregnated by Phase Change Material (상변화물질 함침 경량골재를 사용한 콘크리트의 특성)

  • Kim, Se-Hwan;Jeon, Hyun-Kyu;Hwang, In-Dong;Seo, Chee-Ho;Kim, Sang-Heon
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.3
    • /
    • pp.331-338
    • /
    • 2013
  • Under the paradigm of sustainable green growth at the national level, various researches and applications for energy saving in the construction field has been attempted. As a part of energy saving efforts, lightweight concrete was investigated for thermal insulation concrete with phase change material (PCM) which has high heat storage capacity. As a part of energy saving efforts, thermal insulation concrete was investigated and evaluated with lightweight aggregate impregnated by PCM which has high heat storage capacity. As a result, it is found that concrete with lightweight aggregate impregnated by PCM is effective to prevent its quality deterioration by reducing water absorption rate of lightweight aggregate. In addition, it has shown that concretes using lightweight aggregate and impregnated lightweight aggregate improve heat insulation property 33% and 40~43% compared with using normal aggregate, respectively. It is that the lightweight aggregate concrete with impregnated lightweight aggregate has 12~14% lower thermal conductivity than unimpregnated.

Development of Thermal Storage System in Plastic Greenhouse(II) -Thermal performance of solar greenhouse system for hydroponic culture- (플라스틱 온실(溫室)의 열저장(熱貯藏) 시스템의 개발(開發)에 관(關)한 연구(硏究)(II) -수경재배용(水耕栽培用) 태양열(太陽熱) 온실(溫室) 시스템의 열적(熱的) 성능(性能)-)

  • Kim, Y.H.;Koh, H.K.;Kim, M.K.
    • Journal of Biosystems Engineering
    • /
    • v.15 no.2
    • /
    • pp.123-133
    • /
    • 1990
  • Thermal performance of a solar heating plastic greenhouse designed for a hydroponic system was studied. The system was constructed with the air-water heat exchanger and thermal storage tank that were combined with hydroponic water beds. Experiments were carried out to investigate the daily average heat stored and released in thermal storage tank, average solar energy collection efficiency, average coefficient of performance, average oil reduction factor of thermal storage system, and the heat transfer coefficient during the nighttime in plastic greenhouse. The results obtained in the present study are summarized as follows. 1. Daily average heat stored in thermal storage tank and released from the thermal storage tank was 1,259 and $797KJ/m^2$ day, respectively. 2. The average solar energy collection efficiency of thermal storage tank was 0.125 during the experiment period. And the average coefficient of performance of thermal storage system in plastic greenhouse was 3.6. 3. The average oil reduction factor of thermal storage system and the heat transfer coefficient during the nighttime in plastic greenhouse were found to be 0.52 and $4.3W/m^2\;hr\;^{\circ}C$, respectively.

  • PDF

Heat Storage Material by Using Phase Change Materials to Control Buildings Thermal Environment Characteristics (건축물 열환경 특성제어를 위한 상변화 축열재)

  • Yun, Huy-Kwan;Han, Seong-Kuk;Shim, Myeong-Jin;Ahn, Dae-Hyun;Lee, Woong-Mok;Park, Jong-Soon;Kim, Jae-Yong
    • Applied Chemistry for Engineering
    • /
    • v.21 no.5
    • /
    • pp.522-526
    • /
    • 2010
  • Heat storage application techniques can be categorized into the sensible heat storage and the latent heat storage according to the method of heat storage. Heat storage is the way of saving remaining heat when heating and cooling loads are light, and then using it when the heating and cooling loads are heavy. Latent heat storage is defined as the method of saving heat by using substances which have high potential heat when phase change is in the range of a certain temperature and when heat storage space is small, compared to those of sensible heat storage and it is possible that absorption and emission of heat at a certain temperature. This study is conducted to save energy when either air-conditioning or heating is operated in a building. We have tried to find out the essential properties of matter and the optimum mixing rate about cement and gypsum for building materials, which have been widely used for proper phase change materials (PCM), when thermal environment property is applied. So we obtained the result of the cooling delay effect about 19% with heat storage mortar containing 3 wt% of PCM.