• Title/Summary/Keyword: 열자극 전류

Search Result 28, Processing Time 0.03 seconds

A Design Method for Planar Minimum-Inductance Gradient Coils Considering Pole Piece Effect (Pole piece 효과를 고려한 MRI용 최소 인덕턴스 경사자계 코일 설계 기법)

  • 이수열;강현수;문찬홍;박현욱
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.5
    • /
    • pp.537-544
    • /
    • 1999
  • 자기공명영상시스템의 경사자계코일을 영구자석의 자극에 부착할 경우 경사자계의 분포가 변하고 코일의 인덕턴스가 증가하는 현상이 생긴다. 본 논문에서는 이러한 자극효과를 고려하여 평면형 경사자계코일을 설계하는 방법을 제시하였다. 제사한 방법에는 자극 효과를 거울 전류로 모델링하였고, 모델링한 거울 전류를 고려하여 경사자계코일의 인덕턴스를 최소화하는 방법을 구했다. 또한 실제 상황과 가장 흡사한 자계 분포를 만들어주는 거울 전류의 크기를 구하기 위해 유한요소법을 적용하였다. 제시한 방법으로는 설계된 경사자계코일은 종래의 설계된 경사자계 코일에 비해 우수한 성능을 보였다.

  • PDF

Effect of Microcurrent Therapy on Interleukin-6 Expression in Adjuvant Induced Rheumatoid Arthritis Rat Model (미세전류치료가 아주반트 유도 류마티스관절염 유발 흰쥐의 인터루킨-6 발현에 미치는 영향)

  • Lee, Hyun-Min;Lee, Sang-Yeol;Chang, Jong-Sung;Lee, Myoung-Hee;Kang, Jong-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.4
    • /
    • pp.551-558
    • /
    • 2010
  • 연구목적 : 미세전류 자극이 아주반트로 류마티스 관절염을 유발한 실험동물의 염증반응과 통증에 미치는 효과를 알아보기 위하여 실험동물의 발허리발가락관절내 염증반응 정도를 나타내는 인터루킨-6(interleukin-6)의 발현과 핫플레이트(hot plate)를 이용한 발도피지연시를 측정하여 미세전류의 효과에 대하여 알아보고자 하는데 목적이 있다. 연구방법 : 실험동물은 무작위로 대조군(n=18)과 미세전류를 적용한 실험군(n=18)으로 구분하였고, 각 군당 6마리씩 1일군, 7일군, 14일군으로 배정하였다. 류마티스 관절염 유발후 1일, 7일, 14일에 모든 실험동물의 열통각 역치를 나타내는 발도피지연시와 발허리발가락관절내 인터루킨-6의 발현정도를 측정하였다. 각 집단 내의 기간에 따른 발도피지연시와 인터루킨-6의 면역반응성은 일원배치 분산분석을 실시하였고, 사후분석으로는 Duncan의 다중범위검정을 실시하였다. 실험군과 대조군을 비교하기 위하여 독립표본 t-test를 실시하였다. 연구결과 : 실험결과는 다음과 같다. 1) 아주반트 주사 1일후, 실험군과 대조군에서 인터루킨-6 면역반응성과 발도피지연시는 비슷한 양상을 보였다. 2) 인터루킨-6 면역반응성은 아주반트 주사 7일, 14일 후 대조군이 실험군보다 유의하게 증가되었다(p<.05). 3) 발도피지연시는 아주반트 주사 7일, 14일 후 실험군이 대조군보다 유의하게 증가되었다(p<.05). 결론 : 이상의 결과로부터, 미세전류 자극이 아주반트로 유발된 류마티스관절염 모델에서 활액 조직내 염증반응을 감소시키고 열통각역치는 증가되는 것을 알 수 있었다.

Pulse forming's switching control adopted a Transcranial Magnetic Stimulation Biomedical engineering, Dongju College University (펄스포밍의 스위칭 제어기술을 적용한 경두개 자기자극장치)

  • Kim, Whi-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.3
    • /
    • pp.729-736
    • /
    • 2010
  • In this study, a magnetic stimulation (MS) device with controllable pulse forming technology and pulse shape (MS) is described. The MS device uses an IGBT with appropriate snubbers to switch coil currents up to 6 kA, enabling pulse forming technology control from 5 s to over 100 s. The induced electric field pulses use 2% - 34% less energy and generate 57% - 67% less coil heating compared to matched conventional cosine pulses. MS is used to stimulate rhesus monkey motor cortex in vivo with pulse forming technology of 20 to 100 s, demonstrating the expected decrease of threshold pulse amplitude with increasing pulse forming technology. The technological solutions used in the MS prototype can expand functionality, and reduce power consumption and coil heating in MS, enhancing its research and therapeutic applications.

The Influence of Contamination Affected Phenmenon of Electriacl Conduction in PET (PET의 전기전도현상에 미치는 오염의 영향)

  • 국상훈;고두석
    • Electrical & Electronic Materials
    • /
    • v.1 no.4
    • /
    • pp.333-341
    • /
    • 1988
  • 포리에틸렌, 테레프탈레트를 금속감화물로 오염시켜 열자극특성을 중심으로 가동이온의 중성화, 재이온화 및 이동의 과정등에서 이온의 거동에 관하여 검토하였다. PET가 오염이 되면 이온이 증가되고 전극금속의 영향이 있으며 고온에서 서브리니어 특성을 가지며 가동이온의 증성화 현상이 있는 것을 밝혔다. 가동이돈의 주기적 운동에 기인한 직류전기전도모델로 실험한 결과가 정성적으로 정상전류 전압 특성과 일치함이 입증되었다.

  • PDF

MICROLEAKAGE OF COMPOSITE RESIN RESTORATION ACCORDING TO THE NUMBER OF THERMOCYCLING (열순환 횟수에 따른 복합레진의 미세누출)

  • Kim, Chang-Youn;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.377-384
    • /
    • 2007
  • Present tooth bonding system can be categorized into total etching bonding system (TE) and self-etching boding system (SE) based on their way of smear layer treatment. The purposes of this study were to compare the effectiveness between these two systems and to evaluate the effect of number of themocycling on microleakage of class V composite resin restorations. Total forty class V cavities were prepared on the single-rooted bovine teeth and were randomly divided into four experimental groups: two kinds of bonding system and another two kinds of thermocycling groups. Half of the cavities were filed with Z250 following the use of TE system, Single Bond and another twenty cavities were filled with Metafil and AQ Bond, SE system. All composite restoratives were cured using light curing unit (XL2500, 3M ESPE, St. Paul, MN, USA) for 40 seconds with a light intensity of $600mW/cm^2$. Teeth were stored in distilled water for one day at room temperature and were finished and polished with Sof-Lex system. Half of teeth were thermocycled 500 times and the other half were thermocycled 5,000 times between $5^{\circ}C$ and $55^{\circ}C$ for 30 second at each temperature. Teeth were isolated with two layers of nail varnish except the restoration surface and 1 mm surrounding margins. Electrical conductivity (${\mu}A$) was recorded in distilled water by electrochemical method. Microleakage scores were compared and analyzed using two-way ANOVA at 95% level. From this study, following results were obtained: There was no interaction between variables of bonding system and number of thermocycling (p = 0.485). Microleakage was not affected by the number of thermocycling either (p = 0.814). However, Composite restoration of Metafil and AQ Bond, SE bond system showed less microleakage than composite restoration of Z250 and Single Bond, TE bond system (p = 0.005).

Quantitative vibratory sense measurement systems of a diabetic neuropathy (당뇨병성 신경병증의 정량적 진동 감각 측정 시스템)

  • Ryu, Bong-Jo;Kim, Youngshik;Koo, Kyung-Wan
    • Journal of Digital Contents Society
    • /
    • v.19 no.4
    • /
    • pp.615-620
    • /
    • 2018
  • Evaluation of clinical usefulness of current perception threshold test and vibration sense perception threshold test in diagnosing the diabetic poly-neuropathy patients is one of the diagnosis methods for diabetic poly-neuropathy. Up to the present, some diagnostic methods were used for diabetic poly neuropathy patients. For example, there are neuropathy impairment score test of lower limbs, nerve conduction test, cooling detection threshold test, heat-pain threshold test and so on. However, most of the above tests require very expensive cost and take a lot of time in test. In this paper, a new apparatus estimating vibration sense ability is introduced. For this purpose, the VCM(voice coil motor) stimulating patient's peripheral nerve and current amplifier were manufactured. Also, softwares sensing and driving the vibration detection threshold test in order to measure the quantitative vibration sensory levels in diabetic poly-neuropathy patients were developed.

Oprical Properties of $\alpha$-Sulfur Single Crystal ($\alpha$-sulfur 단결정의 광학적 특성에 관한 연구)

  • 송호준;김화택;이정순
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.6
    • /
    • pp.442-446
    • /
    • 1998
  • $\alpha$--sulfur single crystal which has orthorohmbic structure was grown using Bridgman method. The indirect optical energy band gap of this crystal are 2.65 and 2.82 eV at 10 and 300K, respectively. The wavelengths of photoluminecence(PL) peaks are 543 and 596 nm at 10k, By thermally stimulated current (TSC) method, two electron traps($D_1,D_2$) located at 0/23 and 0.43eV below the conduction band and a hole trap(A) located at 0.31 eV above the valence band are observed. PL mechanism of $\alpha$-sulfur single crystal is analyzed using the values of optical energy band gap at 10k two electron traps and a hole trap.

  • PDF

Study on Polarization Properties of BaTiO3by Using Thermally Stimulated Depolarization Current (열자극 탈분극전류 방법에 의한 BaTiO3의 분극 특성 연구)

  • Song, Ho-Jun;Lee, Yong-Ryeol;Park, Yeong-Joon
    • Korean Journal of Materials Research
    • /
    • v.12 no.8
    • /
    • pp.613-616
    • /
    • 2002
  • The polarization properties of $BaTiO_3$ were investigated by using thermally stimulated depolarization current (TSDC) technique. Two peaks were observed at about 400 K (peak A) and 435 K (peak B) from TSDC spectra obtained from the temperature range of 280-500 K. Peak A shows a sharp decrease of TSDC due to extinction of spontaneous polarization above the phase transition temperature of $BaTiO_3$. The values of activation energy of peak A and peak B were calculated to be 0.70 eV and 0.87 eV respectively. From the results of TSDC measurement with a variation of polarizing electric field strength, we found that saturation of total current of TSDC was started from 3kV/cm. However, the amount of total current of TSDC was not affected by the variation of polarizing time.