• Title/Summary/Keyword: 열부하 해석

Search Result 139, Processing Time 0.026 seconds

Current control of the Inductively Coupled Superconducting Coils for International Thermonuclear Experimental Reactor (국제 열핵융합실험로의 유도 결합된 초전도코일의 전류제어기법 검증)

  • Jo, Jongmin;Lee, Jaedo;Suh, Jae-Hak;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.44-45
    • /
    • 2014
  • 본 논문은 ITER의 플라즈마 제어를 위하여 자기적으로 결합된 초전도 PF 코일에 흐르는 전류를 제어하는 기법과 RTDS 실험결과를 분석하였다. MATLAB/SIMULINK를 이용하여 유도 결합된 4개의 초전도코일을 모델링하여 전류제어기법을 시뮬레이션하였으며, 실험은 RTDS를 이용하여 진행하였다. 각 부하전류가 전류 지령치를 추종할 때, 동시다발적으로 발생하는 상호 인덕턴스와 전류 극성변화의 영향을 MIMO(Multi Input Multi Output) 시스템 기반으로 하여 각 초전도코일의 전압변화 특성을 해석하였다. 시뮬레이션과 실험을 통해 MIMO 시스템 특성의 유도 결합된 초전도코일의 전류제어 특성을 검증하였다.

  • PDF

Protection Analysis of AC/DC Converter for ITER Superconducting Magnet (ITER 초전도자석 전원공급장치의 보호해석)

  • Jo, S.;Lee, S.;Park, H.;Chung, I.;Hwang, K.;Liu, H.;Oh, J.S.;Choi, J.;Suh, J.H.
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.241-242
    • /
    • 2012
  • ITER 초전도자석 전원공급장치에 심각한 고장이 발생할 경우 전원장치뿐만 아니라 그 부하인 초전도코일에도 영향을 줄 수 있다. 초전도코일이 파괴될 경우 수리가 어려워 프로젝트 자체에 중대한 영향을 미칠 수 있어 전원공급장치의 보호는 매우 중요하다. 본 논문에서는 ITER 초전도자석 전원공급장치에서 발생할 수 있는 주요 고장 항목을 소개하고, 전원장치 보호시퀀스에 따른 보호능력의 적합성을 검증한다.

  • PDF

Visualization of Coolant Flow in the Cylinder Read and Exhaust Valve Bridge for the Countermeasure of Thermal Loading in the DOHC Gasoline Engine (DOHC 가솔린기관의 열부하대책을 위한 실린더헤드 및 국소 배기밸브 브릿지부의 냉각수 유동해석)

  • 위신환;이종태
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.6
    • /
    • pp.1-10
    • /
    • 2002
  • As the preliminary stage for the countermeasure of thermal loading in miller cycle engine, coolant flows in the cylinder head of base engine including exhaust valve bridge were visualized and analyzed by using PIV technique. It was found that low coolant velocity regions were around exhaust valve bridge, around which stagnation of the coolant flow was observed due to the complex geometry configuration of water jacket. And velocity variation between each cylinder was remarkable. For the countermeasure of these, it is necessary to enhance coolant flow around exhaust valve bridge and to improve the deviation of coolant flow between each cylinder.

Transient Structural Analysis of Piston and Connecting Rods of Reciprocating Air Compressor Using FEM (FEM을 이용한 왕복동 공기압축기의 피스톤 및 커넥팅로드의 구조해석)

  • Pham, Minh-Ngoc;Yang, Chang-Jo;Kim, Jun-Ho;Kim, Bu-Gi
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.4
    • /
    • pp.393-399
    • /
    • 2017
  • In a reciprocating compressor, the piston and connecting rod are important parts. Excess mechanical stress on these parts may cause damage, and broken parts are expensive and difficult to replace. Therefore, it is necessary to analyze the mechanical stress affecting durability and longevity. The main purpose of this study was to identify locations of maximum stress on pistons and connecting rods. Based on dynamic calculation of the working process of a specific air compressor, an analysis of piston and connecting rod performance has been completed. A three-dimensional model for the air compressor's pistons and connecting rods was built separately, and FEM analysis of these components was carried out using a numerical method. The pistons were loaded by pressure which was changed according to crankshaft angle without thermal boundary conditions. The simulation results were used to predict and estimate stress concentration as well as the value of this stress on pistons and connecting rods. The maximum equivalent stress calculated are over 190 MPa on pistons and 123 MPa on connecting rods at crank angle $135^{\circ}$ and $225^{\circ}$ but these are under tensile yield strength. Besides, the calculated safety factors of connecting rods and pistons is higher than 1. Moreover, the results obtained can be used to provide manufacturers with references to optimize the design of pistons and connecting rods for reciprocating compressors.

Fundamental Heat Analysis about the Thermoelectric Generation System Using the Waste Heat of Exhaust Gas from Ship (선박의 배기가스 폐열을 활용한 열전발전시스템에 관한 기초 열해석)

  • Kim, Myoung-Jun;Ga, Gwang-Jin;Chea, Gyu-Hoon;Kim, In-Seup
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.5
    • /
    • pp.583-592
    • /
    • 2016
  • IMO (International Maritime Organization) in the UN (United Nations) set up that aim at reducing $CO_2$ emission from ship by up to 30 percent until 2030. The final purpose of this study is the development of marine thermoelectric generation system using waste heat from vessel of internal combustion engines. Before the development of marine thermoelectric generation system, this paper carried out the fundamental heat analysis of marine thermoelectric generation system. It was able to obtain the valuable results about the efficiency improvement of the thermoelectric generation system. The results is as follows : 1) It was confirmed that the efficiency of thermoelectric generation system improves to 8.917 % with increasing the temperature difference of peltier module by reducing the temperature difference between peltier module and heat source at the hot side. 2) System efficiency according to change in the external load resistance was confirmed that the change width of about 6 % which does not significantly occur. 3) System efficiency in the case stainless steel at the same condition is 8.707 %. System efficiency could be confirmed that the stainless steel is higher than duralumin (8.605 %), copper (8.607 %).

Evaluation of Indoor Thermal Environment According to Air-Barrier Air Conditioning System in Perimeter Zone (페리미터존의 에어배리어 공조방식에 따른 실내 열환경 평가)

  • Park Byung-Yoon;Ham Heung-Don;Sohn Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.370-376
    • /
    • 2005
  • For the purpose of investigating the effective removal of heating/cooling load from light-weighted building envelope, two air-conditioning systems, conventional parameter air-conditioning system and air-barrier system, are evaluated and compared by both experiment and simulation with six different cases during heating and cooling season. In addition, the characteristics of window-side building thermal load are assessed by varying supply air velocity in order to seek the optimal system operation condition. The results are as follows. 1) Air-barrier system is more effective to remove heating/cooling load at perimeter zone than conventional parameter air-conditioning system. Moreover, the better effectiveness appears during cooling season than during heating season. 2) The experiment during cooling season provides that indoor temperature of air-barrier system shows $1^{\circ}C$ less than that of the conventional system with similar outdoor air temperature profile, and indoor temperature distribution is more uniform throughout the experimented model space. It concludes that air-barrier system can achieve energy saving comparing to the conventional system. 3) The capturing efficiency of air-barrier system is 0.47 on heating season and 0.2 on cooling season with the same supply air volume. It results that the system performs effectively to remove building thermal load, moreover demonstrates high efficiency during cooling season. 4) The simulation results provide that capturing efficiency to evaluate the effective removal of building load from perimeter zone shows high value when supply air velocity is 1 m/s.

Fault Analysis of AC/DC Converter for ITER Superconducting Magnet (ITER 초전도자석 전원공급장치의 고장해석)

  • Park, H.;Lee, S.;Jo, S.;Chung, I.;Hwang, K.;Liu, H.;Oh, J.S.;Choi, J.;Suh, J.H.
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.243-244
    • /
    • 2012
  • ITER 초전도자석 전원공급장치에서 고장의 종류는 단락, 단락 외 컨버터 내부고장 그리고 여러 외부요인에 의한 고장 크게 세 가지로 구분된다. 여기서 단락 외 컨버터 내부고장과 외부요인에 의한 고장은 보호시스템 및 장치의 동작으로 인해 피해가 축소된다. 하지만 단락시에는 보호시스템이 동작하더라도 단락전류가 매우 커 큰 피해를 줄 수 있다. 또한 ITER 초전도자석 전원공급장치는 운전 중 발생 가능한 부하의 단락으로부터 초전도자석 및 다른 장치 등을 보호하기 위하여 ITER에서 요구하고 있는 FSC(Fault Suppression Capability: 고장 억제 능력) 조건을 만족해야 한다. FSC 조건에서 전원공급장치는 출력에서 300 kA의 단락전류가 흐를 경우에도 80 ms(50 Hz, 4주기)동안 전기적 고장 없이 견뎌야 한다. 본 논문에서는 전원공급장치에서 발생될 수 있는 주요 단락 항목을 소개하고, 최악의 조건에서 단락전류에 의한 전원공급장치의 고장해석을 통해 FSC 요건을 만족하는 소자 선정 및 구조설계의 적합성을 검증한다.

  • PDF

Analysis of Eddy Current Loss in the Bobbin Type Cooling Plate for Winding (권선 보빈형 열전도판의 와전류 손실 해석)

  • Park, Myung-Jin;Kwak, Sang-Yeop;Lee, Sang-Yeop;Kim, Woo-Seok;Lee, Ji-Kwang;Choi, Kyeong-Dal;Bae, Joon-Han;Kim, Seok-Ho;Sim, Ki-Duk;Seong, Ki-Chul;Jung, Hyun-Kyo;Hahn, Song-Yop
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.144-145
    • /
    • 2007
  • SMES의 운전 상태는 충전, 운전, 방전의 3가지 모드로 나눌 수 있으며, 충 방전 구간에서 와전류 손실이 발생한다. SMES의 에너지 방전 시 마그넷에서의 전류 감소로 인한 와전류 손실은 비록 짧은 시간동안 발생하지만 그 크기가 냉동기의 정격 열 부하 용량에 비해 상대적으로 크기 때문에, SMES 시스템 설계 시 이에 대한 영향을 고려해야 한다. 본 논문은 고온초전도 선재를 이용하여 개발 중인 600 kJ SMES의 방전 시, 마그넷을 냉각시키기 위한 권선 보빈형 열전도판의 분할과 슬릿의 위치에 따른 와전류 손실 변화를 3차원 유한요소법을 이용해 해석하고 그 결과를 제시하였다.

  • PDF

Effects of Fuel Blending Ratio and Oxygen Concentration on Auto-ignition Characteristics of n-Decane/Ethanol Blended Fuels (연료 혼합비율 및 산소농도가 노말데케인/에탄올 혼합연료의 점화특성에 미치는 영향)

  • Oh, Chae Ho;Kang, Ki Joong;Choi, Gyung Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.11
    • /
    • pp.749-757
    • /
    • 2017
  • To cope with the development of alternative fuels and international environmental regulations, this study provides a numerical analysis of the effects of composition and temperature changes of n-decane and ethanol on auto-ignition characteristics. CHEMKIN-PRO is used as the analysis program and the LLNL model is used as the reaction model. The numerical results show that the ignition delay time increases as the mole fraction of ethanol increases for temperatures below 1000 K, where low temperature reactions occur. Because of the high octane number of ethanol, the high percentage of ethanol delays the increase in the concentration of OH radicals that cause ignition. The oxygen concentration in the mixture is changed to apply the exhaust gas recirculation and a numerical analysis is then performed. As the oxygen concentration decreases, the total ignition delay time increases because the nitrogen gas acts as a thermal load in the combustion chamber.

A Study on the Reliable Video Transmission Through Source/Channel Combined Optimal Quantizer for EREC Based Bitstream (EREC 기반 비트열을 위한 Source-Channel 결합 최적 양자화기 설계 및 이를 통한 안정적 영상 전송에 관한 연구)

  • 김용구;송진규;최윤식
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.12B
    • /
    • pp.2094-2108
    • /
    • 2000
  • 오류를 수반하는 통신망을 통한 멀티미디어 데이터의 응용은 최근 그 수요가 급증하고 있다. 하지만 그 구현은 많은 문제점들을 야기하는데, 전송된 비디오 데이터에 발생한 오류를 처리하는 문제가 그 중 하나이다. 이는 압축된 비트열에 발생한 오류가 영상의 시-공간 방향으로 심각한 전파 현상을 수반하기 때문이다. 이러한 심각한 오류 전파를 완화하기 위해 본 논문에서는 EREC라 알려진 오류 제한 기법을 적용하고, 적용된 EREC의 오류 전파 특성을 분석하였다. 이를 통해, 압축 부호화된 하나의 기본 블록 (매크로 블록)이 복호시 오류가 생길 확률을 추정하였으며, 추정된 확률의 근사를 통해 양 끝단(전송단과 수신단)에서의 비디오 화질 열화를 예측하였다. 추정 확률의 근사는 매 기본 블록에서 발생된 비트수에 대한 그 기본 블록이 복호시 오류가 생길 확률을 간단한 1차식을 통한 선형 회귀법으로 모델링 되었으며, 따라서 간단한 방법을 통해 양 끝단의 화질 열화를 효과적으로 예측할 수 있었다. 부호화된 비트열이 전송 오류에 보다 강인하게 되도록 하기 위해, 본 논문에서 개발된 화질 열화 모델을 양자화기 선택에 적용함으로써, 새로운 최적 양자화 기법을 제시하였다. 본 논문에서 제안된 최적 양자화 기법은, 기존의 양자기 최적화 기법들과는 달리, 복호단에서의 복원 영상 화질이 주어진 비트율에서 최적이 되도록 양자화를 수행한다. H.263 비디오 압축 규격에 적용한 제안 양자화 기법의 실험 결과를 통해, 제안 기법이 매우 적은 계산상의 부하를 비용으로 객관적 화질은 물론 주관적 화질까지 크게 개선할 수 있음을 확인할 수 있었다.내었다.Lc. lacti ssp. lactis의 젖산과 초산의 생성량은 각각 0.089, 0.003과 0.189, 0.003M이었다. 따라서 corn steep liquor는 L. fermentum와 Lc. lactis ssp, lactis 의 생장을 위해 질소 또는 탄소 공급원으로서 배지에 첨가 될 수 있는 우수한 농업 부산물로 판단되었다.징하며 WLWQ에 적용되는 몇 가지 제약을 관찰하고 이를 일반적인 언어원리로 설명한다. 첫째, XP는 주어로만 해석되는데 그 이유는 XP가 목적어 혹은 부가어 등 다른 기능을 할 경우 생략 부위가 생략의 복원 가능선 원리 (the deletion-up-to recoverability principle)를 위배하기 때문이다. 둘째, WLWQ가 내용 의문문으로만 해석되는데 그 이유는 양의 공리(the maxim of quantity: Grice 1975) 때문이다. 평서문으로 해석될 경우 WP에 들어갈 부분이 XP의 자질의 부분집합에 불과하므로 명제가 아무런 정보제공을 하지 못한다. 반면 의문문 자체는 정보제공을 추구하지 않으므로 앞에서 언급한 양의 공리로부터 자유롭다. 셋째, WLWQ의 XP는 주제어 표지 ‘는/-은’을 취하나 주어표지 ‘가/-이’는 취하지 못한다(XP-는/-은 vs. XP-가/-이). 이는 IP내부 에 비공범주의 존재 여부에 따라 C의 음운형태(PF)가 시성이 정해진다는 가설로 설명하고자 했다. WLWQ에 대한 우리의 논의가 옳다면, 본 논문은 다음과 같은 이론적 함의를 기닌다. 첫째, WLWQ의 존재는 생략에 대한 두 이론 즉 LF 복사 이론과 PF 삭제 이론

  • PDF