• Title/Summary/Keyword: 열발생량

Search Result 990, Processing Time 0.03 seconds

Analysis of Test Operations Effect of Open-Closed Loops Complex Geothermal System Combined with Groundwater Well (지하수정호 결합 복합지열시스템의 시범운영 효과분석)

  • Song, Jae-Yong;Kim, Ki-Joon;Lee, Geun-Chun;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.28 no.3
    • /
    • pp.475-488
    • /
    • 2018
  • This study evaluates geothermal system efficiency in terms of input power and heat exchange volume on the heat-source and load sides, by applying a combined open-closed type loop system comprising a geothermal system and a groundwater well to a cultivation site. In addition, this study analyzes the effects of heating and cooling for a complex geothermal system, by evaluating the temperatures of an external site and a cultivation site during operation. During cooling operations the heat exchange volume on the heat source side, average 90.0kW/h for an open type system with an input of 235L/minute groundwater, and 40.1kW/h for a closed type system with an input of 85L/minute circulating water, for a total average heat exchange volume of 130.1kW/h. The actual heat exchange volume delivered on the load side averages 110.4kW/h. The average EER by analysis of the geothermal system's cooling efficiency is 5.63. During heating operation analysis, the heat exchange volume on the heat source side, average 60.4kW/h in an open type system with an input of 266L/minute groundwater, and 22.4kW/h in closed type system with an input of 86L/minute circulating water, for a total average heat exchange volume of 82.9kW/h. The actual heat exchange volume delivered on the load side averages 112.0kW/h in our analysis. The average COP determined by analysis of the geothermal system's heating efficiency is 3.92. Aa a result of the tradeoff between the outside temperature and the inside temperature of the production facility and comparing the facility design with a combined well and open-closed loops geothermal(CWG) system, we determine that the 30RT-volume CWG system temperature are lower by $3.4^{\circ}C$, $6.8^{\circ}C$, $10.1^{\circ}C$ and $13.4^{\circ}C$ for ouside temperature is of $20^{\circ}C$, $25^{\circ}C$, $30^{\circ}C$ and $35^{\circ}C$, respectively. Based on these results, a summer cooling effect of about $10^{\circ}C$ is expected relative to a facility without a CWG system as the outside temperature is generally ${\geq}30^{\circ}C$. Our results suggest that a complex geothermal system provides improvement under a variety of conditions even when heating conditions in winter are considered. Thus It is expected that the heating-cooling tradeoffs of complex geothermal system are improved by using water screen.

Heat efficiency Analysis of PVT module system using CFD (CFD를 이용한 PVT 모듈 열교환기 성능 해석)

  • Kim, Yangjoon;Kim, Dongkwon;Nam, Seungbaek;Cho, Insoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.112.2-112.2
    • /
    • 2011
  • PVT(Photovoltaic Thermal) 모듈은 태양광과 태양열 에너지를 동시 이용이 가능한 모듈로서 태양광전지(PV, Photovoltaic)모듈에 열교환기를 접합한 형태로 전기에너지뿐만 아니라 열에너지를 동시에 생산할 수 있는 시스템이다. 기존 PV 모듈은 일사량이 많으면 전력 생산량이 증가하는 동시에 PV모듈의 온도가 상승함에 따라 발전 효율이 감소하는 문제점이 있으며 일반적으로 $25^{\circ}C$이상 조건에서 모듈 온도가 $10^{\circ}C$ 증가할수록 발전효율의 약 4~5% 정도 감소하는 것으로 보고되고 있다. PVT 모듈은 기존 태양광모듈에 열교환기를 접합하여 냉각함으로써 PV모듈의 온도를 낮추어 발전효율을 증가시키는 동시에 부가적으로 발생하는 온수를 직접이용하거나 다양한 계통의 보조 열원으로 이용할 수 있는 장점이 있다. 본 연구에서는 수치해석기법(CFD)을 활용하여 PV모듈 냉각 및 온수 발생을 위한 열교환기를 설계하였으며 다양한 형상의 열교환기에 대해 유동해석을 수행하여 최적의 열흡수효율을 갖는 열교환기의 형상을 설계하였다. 또한 최적 설계된 PVT 모듈을 제작하여 실제 태양과 유사한 광원을 갖는 인공태양조건에서의 실내 실험을 통해 PVT 모듈의 성능을 검증하였으며 또한 실제 노상에 설치하여 ASHRAE 93-77의 실험기준과 ECN의 PVT 집열기 성능측정 가이드라인에 따라 옥외 시험평가를 하여 PVT 모듈의 성능 검증을 하였다. 최적 설계된 PVT모듈에 대한 성능평가 결과 기존 PV 모듈보다 발전효율이 약 15%(기존 발전효율 대비) 향상된 결과를 확인하였다.

  • PDF

영상처리에 의한 압연철판 최적절단의 최적화

  • 이상열;정성호;황병곤
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 1998.03a
    • /
    • pp.89-92
    • /
    • 1998
  • 압연철판의 생산라인에 있는 카메라에 입력되는 영상정보를 Image Frame Grabber를 이용하지 않고 Video Overlay Board를 사용하여 라인에 입력되는 압연철판을 분석하여 외곽선을 가로지른 선분의 길이가 기준에 준할 때 정확한 절단정보를 발생시킴으로 기존에 사용해온 작업자의 대략적인 지식을 이용한 절단에서 발생되는 압연 철판의 손실을 최소화시키며 불량률을 줄인다. 그리고 발생되는 정보를 DB화시킴으로 생산품의 정확한 재고량을 관리하는 시스템을 개발한다.

Estimation of water surface evaporation in Yongdam Dam using Empirical wind function (경험적 바람공식을 적용한 용담댐 내의 수면증발량 추정)

  • Minwoo Park;Sumiya Uranchimeg;Ho-Jun Kim;Min-kyu Jung;Hyun-Han Kwon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.291-291
    • /
    • 2023
  • 증발량을 산정하는 방법 중 증발접시를 활용한 방법은 하천의 증발량을 직접적으로 측정할 수 있는 장점이 있는 반면, 장기간의 증발접시를 활용한 증발량 추정은 현실적으로 쉽지 않다. 대표적인 증발량 산정식으로는 에너지 수지 및 공기동역학적 원리의 혼합적용 방법(PCE, Penman combination equation)과 경험적 바람공식(PWF, Penman wind function)이 있다. PCE로 산정된 증발량의 경우 하천 내 바닥열(bed heat flux)과 물기둥의 열저장 변화율이 장기간 규모의 순 복사량에 비해 작은 값을 가져 식에서 제외되므로 전반적으로 증발량이 과대 추정되는 문제가 발생한다. 반면, PWF로 산정한 증발량에서는 광범위한 매개변수 범위와 기상자료의 부족으로 모형의 불확실성을 증대시키는 요인으로 작용한다. 본 연구의 최종적인 목표는 하천 수로의 수면증발량을 추정하는 것이지만, 실제 하천 중심에서 증발량을 추정하기 위한 수문학적 자료는 매우 부족한 실정이다. 따라서, 본 연구에서는 유역단위에서의 증발량을 전이하는 방안을 모색하고자 하며, 구체적인 연구과정은 다음과 같다. 첫째, 유역단위 수문학적 자료를 수집하여(flux tower 자료 활용) 유역단위의 증발량을 산정한다. 둘째, PCE와 PWF으로 산정한 증발량과 관측된 증발량을 이용하여 각 식의 매개변수를 최적화한다. 마지막으로 최적화된 매개변수를 적용한 증발량과 관측값의 유사성을 분석한다. 본 연구에서는 하천단위의 증발량을 산정하기 위해 PWF을 적용하였으며 용담댐 내의 기상자료를 활용하여 산정한 증발량과 실제 용담댐 내의 수면증발량의 상관성을 분석한 결과 높은 상관성 확인할 수 있었다. 따라서 하천 주변에 증발량 추정을 위한 최소한의 기상정보가 존재하는 지역에서, 하천단위의 증발량을 산정할 수 있으며 장기간의 증발량도 산정할 수 있을 것으로 판단된다.

  • PDF

Optimization of the Layout of a Radioactive Waste Repository Based on Thermal Analysis (열해석에 기초한 방사성폐기물 처분장 배치 최적화)

  • Kwon Sangki;Choi Jong-Won;Cho Won-Jin
    • Tunnel and Underground Space
    • /
    • v.14 no.6 s.53
    • /
    • pp.429-439
    • /
    • 2004
  • The deep underground High Level Waste (HLW) repository to dispose of 36,000tons of spent fuel from the reactors in Korea needs about $4km^2$ repository area. In this study, the deep undergrond repository layout was optimized to minimize the excavation rock volume as well as underground repository area. In the optimization, the results from thermal analysis were used to define the influence of tunnel and deposition hole spacings on repository layout. The repository area and excavation rock volume could be reduced with longer disposal tunnel length. When it is necessary to reduce the repository area with satisfying thermal criteria, it is better to reduce tunnel spacing and increase deposition hole spacing. In contrast, the excavation rock volume can be reduced by increasing the tunnel spacing and decreasing the hole spacing.

Structural Breaks in the Securities markets (자본시장과 구조변화)

  • Rhee, Il-King
    • The Korean Journal of Financial Management
    • /
    • v.19 no.1
    • /
    • pp.1-32
    • /
    • 2002
  • 한국 종합주가지수는 한국증권거래소에 상장된 모든 기업들의 가치 가중치에 의한 포트폴리오의 가격의 시계열이라고 할 수 있다. 따라서 이 지수는 한국 경제의 현재의 활동과 미래의 활동에 대한 예상의 총합의 반영 또는 표상을 표현하는 정보라 할 수 있다. 본 논문에서는 시차변수가 독립변수로 도입될 수도 있으며, 시차변수가 아닌 변수가 독립변수로 도입되는 것이 허용되는 회귀모형을 통하여 구조변화의 회수와 구조변환점을 검정할 수 있는 통계량과 이 통계량의 확률분포를 분석하고 한국 종합주가지수에 적용하여 한국 종합주가 지수의 일별수익률에 구조변화가 발생하였는지의 여부와 발생했다면 발생회수와 변환점들을 발견하는데 그 목적이 있다. 한국 종합주가지수의 일별수익률은 분산의 변화 그리고 평균 및 분산의 동시변화가 1997년 9월 27일에 발생하였다. 자기회귀모형에 의할 때 증권시장의 구조변화는 1999년 11월 16일에 이루어졌다. 평균과 분산의 변화가 일어나 구조변화의 단계를 시작하고 구조변화에 알맞는 환경조성에 2년이 소요된 후에 1999년 11월 16일에 구조변화가 정착되었다. 정착이 이루어진 후에야 비로서 이 두 기간은 서로 다른 경제구조와 증권시장구조가 이루어지고 이에 입각하여 시장의 새로운 운동법칙이 전개되고 있다고 할 수 있을 것이다.

  • PDF

Shift Characteristics Analysis of Transmission for Construction Vehicles (건설차량용 변속장치의 특성 해석)

  • 윤소남;함영복;류찬수;최병오
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.674-679
    • /
    • 2002
  • As the object of this study, a transmission system with the style of HST in combination with mechanical semi-automatic transmission for application in hydraulic wheel excavators was chosen. The dynamic characteristics of the object transmission was studied by numerical analysis of the mathematical model. The results of numerical analysis showed comparatively good agreements with experimental results, so the validity of the numerical analysis process was ascertained.

  • PDF

아트리움의 Ceiling Jet 온도 예측 모델 비교

  • 김운형;김종훈;이수경
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2000.06a
    • /
    • pp.144-149
    • /
    • 2000
  • 최근에 국내에서도 대형 쇼핑 몰이나 건축물에 부속된 아트리움 등 대형공간을 도입한 건축물이 점차 증가하고 있다. 따라서 건물 방화 설계자는 화재시 공간의 특성에 따른 열과 연기의 확산과 이동에 관한 정량적인 해석이 필요하지만 국내에서는 아직 이에 대한 관련 규정이 미비한 실정이다. 대형 공간의 공학적인 해석은 크게 실험을 통하여 제시되는 계산공식을 이용하거나 대상 공간의 화재 조건을 예측하는 컴퓨터 모델을 이용할 수 있다. 외국의 경우, 미국의 NFPA 92B는 이러한 공간에 대한 제연 시스템에 적용하는 공식과 계산식을 제시하고 있으며 이를 통하여 연기나 열 감지기의 작동시간, 연기 발생비율, 연기 층의 하강을 제어하기 위한 배기량 등을 계산할 수 있다. (중략)

  • PDF

Study on the Performance of the Separate type Heat Pipe Using the Parallel Flow type Heat Exchanger (평행류형 열교환기를 이용한 분리형 히트파이프의 성능에 관한 연구)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5045-5050
    • /
    • 2015
  • As modern houses are constructed with high-density and high-insulation, there is benefit to reduce energy consumption, but there are many side effects raised from polluted air. To solve the problem, a ventilation system is used to improve a indoor air quality. In this study, we tested the parallel flow type heat exchanger used in a heat exchanger of an automotive air conditioner. And we experimentally estimate ventilation performance of HRV(heat recovery ventilator) with heat-pipe according to working fluid filling quantity and ventilation. The working fluid was R22, which was filled from 40 to 60 (%vol.) by 10(%vol.). Ventilation based on the front velocity was measured from 0.3 m/s to 1.5 m/s by 0.3 m/s intervals. Refrigerant filling quantity with the highest efficiency was found to depend on the ventilation. From this study the optimal refrigerant filling quantity in accordance with the ventilation of the detachable heat pipes was found experimentally.

Syngas production from pyrolysis and gasification of rice husks by simulation study (전산해석을 통한 초본계 농업부산물의 합성가스 생산 특성)

  • Kim, Suhyun;Gu, Jaehoi;Park, Yongcheol
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.249.1-249.1
    • /
    • 2010
  • 현재 농업부산 폐자원은 퇴비, 가축사료 등의 단순 활용이 대부분을 차지하고 있어, 열분해 가스화를 통한 고효율 에너지 이용 시스템 개발로 기존 단순 활용에 그치던 농업부산 폐자원의 고부가가치 이용이 절실히 필요한 실정이다. 본 연구에서는 초본계 농업부산물인 왕겨를 이용한 열분해 가스화 시스템에 대한 특성 파악 및 초본계 농업부산물을 이용한 에너지자원화 및 고효율 에너지 이용을 위한 방안을 모색하고자 다양한 조건에서 전산해석을 수행하였다. 공정해석에 사용된 왕겨는 수분함량 11.33%, 회분함량 10.66%, 가연분 함량, 78.01%의 조성으로, 발열량은 LHV 기준으로 3,729 kcal/kg 였다. 상용해석 프로그램을 사용하여 열분해로의 열손실, 투입되는 시료의 가스화 반응 비율 변화, 열분해 가스화 반응의 산화제로 사용되는 공기의 유량 변화에 따른 발생되는 가스의 유량, 성상, 온도 특성을 파악하였다.

  • PDF