• Title/Summary/Keyword: 연쇄성

Search Result 631, Processing Time 0.029 seconds

DNMT3b Promoter Polymorphism and Risk of Gastric Cancer in the Korean Population (한국인에서 DNMT3b 유전자 다형성과 위암의 감수성)

  • Kim, Sung Geun;Jung, Hun;Kim, Sin Sun;Jeon, Kyung Hwa;Song, Kyo Young;Kim, Jin Jo;Jin, Hyung Min;Kim, Wook;Park, Cho Hyun;Park, Seung Man;Lim, Keun Woo;Kim, Seung Nam;Jeon, Hae Myung
    • Journal of Gastric Cancer
    • /
    • v.7 no.1
    • /
    • pp.9-15
    • /
    • 2007
  • Purpose: DNA methylation is an important epigenetic factor in tumorigenesis. We hypothesized that polymorphism of the promoter of the DNA methyltransferase 3b (DNMT3b) genes, which are responsible for regulating the methylation status of tumor suppressor genes, are associated with increased risk of gastric cancer. Materials and Methods: In this hospital-based case-control study, to determine the role of this polymorphism of the promoter of DNA methyltransferase 3b (DNMT3b) genes in gastric cancer, we genotyped 176 cases and 70 control subjects. To determine the genotype, we used a polymerase chain reaction restriction fragment length polymorphism assay. We compared alleles and genotypes between the two groups and revealed an association of DNMT3b promoter polymorphism with increased risk of gastric cancer in the Korean population. Results: Genotype frequencies were 14.8% (Cytosine-Cytosine), 71.6% (Cytosine-Thymine), and 13.6% (Thymine- Thymine) in the case patients and 40.0% (Cytosine-Cytosine), 42.9% (Cytosine-Thymine), and 17.1% (Thymine-Thymine) in the control subjects, respectively. Compared with CC homozygotes, CT heterozygotes had a 4.523-fold increased risk (OR, 2.13; 95% CI, 2.324~8.803), and the TT homozygotes had a 2.154-fold elevated risk (OR, 1.42; 95% CI, 0.899~85.165). For the T variant genotype (CT+TT), there was a 3.846-fold increased risk (OR, 1.88; 95% CI, 2.040~7.251). However, no significance was observed in the genotype distributions of both polymorphisms according to histopathology, stage of stomach cancer. The Ssame results were observed with Helicobacter infection. Conclusion: DNMT3b promoter polymorphism, especially the T variant genotype, is associated significantly with thean increased risk of gastric cancer.

  • PDF

Particulate Matter from Asian Dust Storms Induces the Expression of Proinflammatory Cytokine in A549 Epithelial Cells (PM10이 A549 Cells에서 전염증성 Cytokine발현에 미치는 영향)

  • Kim, Jung Ho;Jeon, Hyo Keun;Kim, Mi Kyeong;Kyung, Sun Yong;An, Chang Hyeok;Lee, Sang Pyo;Park, Jung Woong;Jeong, Sung Hwan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.6
    • /
    • pp.663-672
    • /
    • 2006
  • Background: $PM_{10}$(Particulate matter with a diameter ($<10{\mu}m$), which is characterized by different environmental conditions, is a complex mixture of organic and inorganic compounds. The Asian dust event caused by meteorological phenomena can also produce unique particulate matter in affected areas. This study investigated the cytokine produced by A549 epithelial cells exposed to particles collected during both the Asian dust pfenomenon and ambient air particles in a non-dusty period. Method: Air samples were collected using a high volume air sampler(Sibata Model HV500F) with an air flow at $500{\ell}/min$ for at least 6 hours. The cytokine messenger RNA(mRNA) was measured using a reverse transcriptase polymerase chain reaction(RT-PCR). The A549 cells were exposed to 10 to $500{\mu}g/m{\ell}$ of a suspension containing $PM_{10}$ for 24 hours. Each was compared with those in the non-exposed control cells. Result: The mRNA levels of interleukin(IL)-$1{\alpha}$, $IL-I{\beta}$, IL-8, and the granulocyte macrophage colony stimulating factor(GM-CSF) increased after veing exposed to $PM_{10}$ in the ambient air particles, compared with those in the non-exposed control cells. The increase in $IL-1{\alpha}$ and IL-8 were dose dependent at a $PM_{10}$ concentration between $100{\mu}g/m{\ell}$ and $500{\mu}g/m{\ell}$. The mRNA level of IL-8 in the A549 epithelial cells was higher during the in the Asian dust period($500{\mu}g/m{\ell}$) than during the non dust period. Conclusion: A549 cells exposed to the $PM_{10}$ collected during the Asian dust period produce more proinflammatory cytokine than during non-dusty period. This cytokine enhances the local inflammatory response in the airways and can also contribute to the systemic component of this inflammatory process.

A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer (변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구)

  • Kim, Do-Hyun;Cho, Nam-Wook;Yoon, Choung-Ho;Park, Pil-Yong;Park, Keun-Sung
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.53-62
    • /
    • 2017
  • Electric power which is the energy source of economy and industries requires long distance transportation due to regional difference between its production and consumption, and it is supplied through the multi-loop transmission and distribution system. Prior to its actual use, electric power flows through several transformations by voltage transformers in substations depending on the characteristics of each usage, and a transformer has the structure consisting of the main body, winding wire, insulating oil and bushings. A transformer fire that breaks out in substations entails the primary damage that interrupts the power supply to houses and commercial facilities and causes various safety accidents as well as the secondary economic losses. It is considered that causes of such fire include the leak of insulating oil resulting from the destruction of bottom part of bushings, and the chain reaction of fire due to insulating oil that reaches its ignition point within 1 second. The smoke detector and automatic fire extinguishing system are established in order to minimize fire damage, but a difficulty in securing golden time for extinguishing fire due to delay in the operation of detector and release of gas from the extinguishing system has become a problem. Accordingly, this study was carried out according to needs of active mechanism to prevent the spread of fire and block the leak of insulating oil, in accordance with the importance of securing golden time in extinguishing a fire in its early stage. A bushings fireproof structure was developed by applying the high temperature shape retention materials, which are expanded by flame, and mechanical flame cutoff devices. The bushings fireproof structure was installed on the transformer model produced by applying the actual standards of bushings and flange, and the full scale fire test was carried out. It was confirmed that the bushings fireproof structure operated at accurate position and height within 3 seconds from the flame initiation. It is considered that it could block the spread of flame effectively in the event of actual transformer fire.

Diagnostic Evaluation of the BioFire® Meningitis/Encephalitis Panel: A Pilot Study Including Febrile Infants Younger than 90 Days (BioFire® Meningitis/Encephalitis Panel의 진단적 유용성 평가: 90일 미만 발열영아에서의 예비 연구)

  • Kim, Kyung Min;Park, Ji Young;Park, Kyoung Un;Sohn, Young Joo;Choi, Youn Young;Han, Mi Seon;Choi, Eun Hwa
    • Pediatric Infection and Vaccine
    • /
    • v.28 no.2
    • /
    • pp.92-100
    • /
    • 2021
  • Purpose: Rapid detection of etiologic organisms is crucial for initiating appropriate therapy in patients with central nervous system (CNS) infection. This study aimed to evaluate the diagnostic value of the BioFire® Meningitis/Encephalitis (ME) panel in detecting etiologic organisms in cerebrospinal fluid (CSF) samples from febrile infants. Methods: CSF samples from infants aged <90 days who were evaluated for fever were collected between January 2016 and July 2019 at the Seoul National University Children's Hospital. We performed BioFire® ME panel testing of CSF samples that had been used for CSF analysis and conventional tests (bacterial culture, Xpert® enterovirus assay, and herpes simplex virus-1 and -2 polymerase chain reaction) and stored at -70℃ until further use. Results: In total, 72 (24 pathogen-identified and 48 pathogen-unidentified) CSF samples were included. Using BioFire® ME panel testing, 41 (85.4%) of the 48 pathogen-unidentified CSF samples yielded negative results and 22 (91.7%) of the 24 pathogen-identified CSF samples yielded the same results (enterovirus in 19, Streptococcus agalactiae in 2, and Streptococcus pneumoniae in 1) as those obtained using the conventional tests, thereby resulting in an overall agreement of 87.5% (63/72). Six of the 7 pathogen-unidentified samples were positive for human parechovirus (HPeV) via BioFire® ME panel testing. Conclusions: Compared with the currently available etiologic tests for CNS infection, BioFire® ME panel testing demonstrated a high agreement score for pathogen-identified samples and enabled HPeV detection in young infants. The clinical utility and cost-effectiveness of BioFire® ME panel testing in children must be evaluated for its wider application.

Research on the revitalization of Japanese artworks: Focus on Japan Advanced Art Museum Policy (일본의 문화경제전략과 미술품 유동성 활성화에 관한 연구 - 문화청의 선진미술관 정책 추진을 중심으로 -)

  • Chu, Min-Hee
    • Korean Association of Arts Management
    • /
    • no.51
    • /
    • pp.135-166
    • /
    • 2019
  • Recently, the Japan Cultural Agency announced a plan for revitalizing the art market represented by reading museums (advanced art museums) to promote industry through strengthening the sustainability and economics of art museums. Along with these policy announcements, the Japanese cultural system and Bypyeongje are divided into pros and cons, and there has been a heightened opposition, which is now in a state where policy promotion has been temporarily suspended. The opposite reason is that it does not meet the museum's inherent purpose of preservation and lore, and the reason for favoring that commercialism can ruin the art world is that the Japanese art society is other than art museums and museums Also, it consists of non-profit organizations, art festival administration organizations, support staff, volunteers, etc., but because of the high subsidy bias, no real labor costs are paid, which means that it is virtually neglected. Also, there is a vigilance that the art society itself, which reduces its reliance on subsidies in response to social changes, can survive. Seeing that the situation is not much different from Japan, Korea is also actively discussing new establishments of the National Art Bank, performing art appraisal and evaluation functions for revitalizing art works, art loan, art trust, etc. There is. As it is difficult to solve realistic problems with subsidies from the future situation, it is difficult for us to expand investment in culture, and culture and economy are united and linked. You will find a plan to make it operational. In this regard, it is thought that the examination of the cultural and economic agency's strategy, represented by the Japanese advanced art museums, gives us a meaningful suggestion.

A Study on the Location of Retail Trade in Kwangju-si and Its Inhabitants와 Effcient Utilization (광주시 소매업의 입지와 주민의 효율적 이용에 관한 연구)

  • ;Jeon, Kyung-sook
    • Journal of the Korean Geographical Society
    • /
    • v.30 no.1
    • /
    • pp.68-92
    • /
    • 1995
  • Recentry the structure of the retail trade have been chanaed with its environmantal changes. Some studies may be necessary on the changing process of environment and fundamental structure analyses of the retail trade. This study analyzes the location of retail trades, inhabitants' behavior in retail tredes and their desirable utilization scheme of them in Kwangju-si. Some study methods, contents and coming-out results are as follows: 1. Retail trades can be classified into independent stores, chain-stores (supermarket, voluntary chain and frenchiise system and convenience store), department stores, cooperative associations, traditional, markets mail-order marketing, automatic vending and others by service levels, selling-items, prices, managements, methods of retailing and store or nonstore type. 2. In Kwangju, the environment of retail trades is related to the consumers of population structure: chanes in consumers pattern, trends toward agings and nuclear family, increase of leisur: time and female advances to society. Rapid structural shift in retail trade has also been occurred due to these social changes. Traditionl and premodern markets until 1970s altere to supermarkets or department stores in 1980s, and various types, large enterprises and foreign capitals came into being in 1990s. 3. The locational characteristics of retail trades are resulted from the spatial analysis of the total population distribution, and from the calculation of segregation index in the light of potential demand. The densely-populated areas occurs in newly-built apartment housing complex which is distributed with a ring-shaped pattern around the old urban core. The numbers and rates of the aged over sixty in Kwangsan-gu and the circumference area of Mt.Moodeung, are larger and higher where rural elements are remarkable. A relation between population distribution and retail trade are analysed by the index of population per shop. The index of the population number per shop is lower in urban center, as a whole, being more convenient for consumers. In newly-formed apartment complex areas, on the other, the index more than 1,000 per shop, meeting not the demands for consumers. Because both the younger and the aged are numerous in these areas, the retail trade pattern pertinent to both are needed. Urban fringes including Kwangsan-gu and the vicinity of Mt.Moodeung have some problems owing to the most of population number per shop (more than 1, 500) and the most extensive as well. 4. The regional characteristic of retail trade is analyzed through the location quotient of shops by locational patterns and centerality index. Chungkum-dong is the highest-order central place in CBD. It is the core of retail trades, which has higher-ordered specialty store including three big department stores, supermarkets and large stores. Taegum-dong, Chungsu-dong, Taeui-dong, and Numun-dong that are neiahbored to Chungkum-dong fall on the second group. They have a central commercial section where large chain stores, specialty shopping streets, narrow-line retailing shops (furniture, amusement service, and gallary), supermarkets and daily markets are located. The third group is formed on the axis of state roads linking to Naju-kun, Changseong-kun, Tamyang-kun, Hwasun-kun and forme-Songjeong-eup. It is related to newly, rising apartment housing complex along a trunk road, and characterized by markets and specialty stores. The fourth group has neibourhood-shopping centers including older residential area and Songjeong-eup area with independent stores and supermarkets as main retailing functions. The last group contains inner residential area and outer part of a city including Songjeong-eup. Outer part of miscellaneous shops being occasionally found is rural rather than urban (Fig. 7). 5. The residents' behaviors using retail trade are analyzed by factors of goods and facilities. Department stores are very high level in preference for higher-order shopping-goods such as clothes for full dress in view of both diversity and quality of goods(28.9%). But they have severe traffic congestions, and high competitions for market ranges caused by their sma . 64.0% of respondents make combined purpose trips together with banking and shopping. 6. For more efficiency of retail-trading, it is necessary to induce spatial distribution policy with regard to opportunity frequency of goods selection by central place, frontier regions and age groups. Also we must consider to analyze competition among different types of retail trade and analyze the consumption behaviors of working females and younger-aged groups, in aspects of time and space. Service improvement and the rationalization of management should be accomplished in such as cooperative location (situation) must be under consideration in relations to other functions such as finance, leisure & sports, and culture centers. Various service systems such as installment, credit card and peremium ticket, new used by enterprises, must also be carried service improvement. The rationalization and professionalization in for the commercial goods are bsically requested.

  • PDF

Community Dynamics of Phytoplankton and Bacteria as Affected by Physicochemical Environmental factors in Hoeya Dam Reservoir (회야댐 저수지에서 물리 ${\cdot}$ 화학적 환경요인에 따른 식물플랑크톤과 세균 군집의 변화)

  • Kim, Dae-Kyun;Choi, Ae-Ran;Lee, Hye-Kyeong;Kwon, O-Seob;Kim, Jong-Seol
    • Korean Journal of Ecology and Environment
    • /
    • v.37 no.1 s.106
    • /
    • pp.26-35
    • /
    • 2004
  • We investigated the effect of physicochemical environmental factors on the community dynamics of phytoplanktons and bacteria at the Hoeya Dam Reservoir, a drinking water reservoir for Ulsan city. Water samples were collected and analyzed every two to four weeks at three sites along the reservoir from April to October, 2001. During the study period, the Secchi depths were between 0.4 and 3.5 m. At the surface layer of water column, temperature ranged 10.2 ~ $32.0^{\circ}C$, pH 7.3${\sim}$9.6, dissolved oxygen 5.5 ${\sim}$ 12.4 mg $L^{-1}$, $BOD_5$ 0.8 ${\sim}$ 5.0 mg $L^{-1}$, $COD_{Mn}$ 3.7 ${\sim}$ 10.0 mg $L^{-1}$, and Chl-a 8.9 ${\sim}$ 60.9 mg $m^{-3}$. At the bottom layer, temperature varied 7.2 ${\sim}$ $28.9^{\circ}C$, pH 7.1 ${\sim}$ 9.3, dissolved oxygen 0.6 ${\sim}$ 9.7 mg $L^{-1}$, $BOD_5$ 0.8 ${\sim}$ 4.5 mg $L^{-1}$, $COD_{Mn}$ 3.9 ${\sim}$ 10.0 mg $L^{-1}$, and Chl-a 4.3 ${\sim}$ 81.9 mg $m^{-3}$. The numbers of phytoplanktons were 7.4${\pm}10^2{\sim}2.6{\pm}10^5$ cells $mL^{-1}$ at surface and 2.5${\pm}10^2{\sim}2.4{\pm}10^4$ cells $mL^{-1}$ at bottom, and were positively correlated with water temperature and Chl- a concentration. Genus Stephanodiscus and genus Oscillatoria dominated on April and on May, respectively. Cyanobacterial blooms of Aphanizomenon, Microcystis, Anabaena were observed from June to early September, and thereafter Stephanodiscus and Aulacoseiral dominated again. Total microbial counts ranged 1.73${\pm}10^4{\sim}1.68{\pm}10^5$ cells $mL^{-1}$, and were positively correlated with water temperature and phytoplankton counts at surface water. Heterotrophic plate counts (HPCs) ranged 30${\sim}4.1{\pm}10^3$ CFU $mL^{-1}$, and were positively correlated with $BOD_5$ and $NO^3\;^-$-N concentration at bottom water. Unlike the total microbial counts, the numbers of fecal coliforms and fecal streptococci as well as HPCs were higher at the bottom than the surface layer and were highest at the upper a site among the three sampling sites. Since the concentrations of fecal coliforms and streptococci were still high at the bottom of site c, where intake for water treatment plant is located, it appeared that special management of water treatment processes may be needed especially after strong rainfall.

A Comparative Study of Subset Construction Methods in OSEM Algorithms using Simulated Projection Data of Compton Camera (모사된 컴프턴 카메라 투사데이터의 재구성을 위한 OSEM 알고리즘의 부분집합 구성법 비교 연구)

  • Kim, Soo-Mee;Lee, Jae-Sung;Lee, Mi-No;Lee, Ju-Hahn;Kim, Joong-Hyun;Kim, Chan-Hyeong;Lee, Chun-Sik;Lee, Dong-Soo;Lee, Soo-Jin
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.234-240
    • /
    • 2007
  • Purpose: In this study we propose a block-iterative method for reconstructing Compton scattered data. This study shows that the well-known expectation maximization (EM) approach along with its accelerated version based on the ordered subsets principle can be applied to the problem of image reconstruction for Compton camera. This study also compares several methods of constructing subsets for optimal performance of our algorithms. Materials and Methods: Three reconstruction algorithms were implemented; simple backprojection (SBP), EM, and ordered subset EM (OSEM). For OSEM, the projection data were grouped into subsets in a predefined order. Three different schemes for choosing nonoverlapping subsets were considered; scatter angle-based subsets, detector position-based subsets, and both scatter angle- and detector position-based subsets. EM and OSEM with 16 subsets were performed with 64 and 4 iterations, respectively. The performance of each algorithm was evaluated in terms of computation time and normalized mean-squared error. Results: Both EM and OSEM clearly outperformed SBP in all aspects of accuracy. The OSEM with 16 subsets and 4 iterations, which is equivalent to the standard EM with 64 iterations, was approximately 14 times faster in computation time than the standard EM. In OSEM, all of the three schemes for choosing subsets yielded similar results in computation time as well as normalized mean-squared error. Conclusion: Our results show that the OSEM algorithm, which have proven useful in emission tomography, can also be applied to the problem of image reconstruction for Compton camera. With properly chosen subset construction methods and moderate numbers of subsets, our OSEM algorithm significantly improves the computational efficiency while keeping the original quality of the standard EM reconstruction. The OSEM algorithm with scatter angle- and detector position-based subsets is most available.

Changes in Serum IGF-I and Spermatogenesis Analysed by Flow Cytometry in Growing Male Rabbit (성장 중인 수토끼에서 혈청 IGF-I 수준과 Flow Cytometry 측정에 의한 정자 형성의 변화)

  • Lee J. H.;Kim C. K.;Chang Y. M.;Ryu J. W.;Park M. Y.;Chung Y. C.;Pang M. G.
    • Reproductive and Developmental Biology
    • /
    • v.29 no.3
    • /
    • pp.163-168
    • /
    • 2005
  • The aim of this study was to investigate the changes in insulin-like growth factor-I (IGF-I) and growth hormone (GH) in serum, the quantitation of spermato-genesis and the comparable relationships among these measurements during pubertal period in New Zealand White male rabbits. To investigate the age-related testicular changes in DNA contents of spermatogenic cells, the fine-needle testicular biopsies from males aged 10 to 28 wks were evaluated by flow cytometry(FCM). Body weight increased significantly between the ages of 12 and 20 wks (P<0.05) and reached 3.4 kg at 28 wks of age. The highest serum IGF-I level (451.3ng/mL) was observed at 20wks of age (P<0.05) and thereafter remained stable at low levels. Serum GH level at 18 wks of age was 183.3 pg/mL which was significantly higher compared to the other ages (P<0.05), and the rising time in serum GH tend to be somewhat earlier than that of IGF-I. The relative percentage of It-cells in testicular cell compartments was $48.2\%$ at the age of 18 wks which significantly increased than those of 16-wk-old (P<0.05) and thereafter increased with the advance of age to $68\%$. The percentage of 2C-cells in testis was $26.8\%$ at 18 wks of age which was significantly lower than $54.3\%$ at 16 wks old (P<0.05). The percentage of 4C-cells was constantly maintained $2\~6\%$ except the $9.9\%$ at 18 wks of age. In conclusion, the results suggest that the puberty onset occurred at about the 18 wks of age and that the IGF-I and GH in serum during the pubertal period showed the age/growth-specific changes and these changes might be related to the spermatogenesis. The DNA FCM combined with fine-needle testicular biopsy could offer a very sensitive method to monitor the quantitative spermatogenic events related to the puberty onset.

Correlation Between Angiotensin-Converting Enzyme(ACE) Inhibitor Induced Dry Cough and ACE Gene Insertion/Deletion(I/D) Polymorphism (안지오텐신 전환효소 억제제에 의한 건성 기침의 발생과 안지오텐신 전환효소 유전자 다형성과의 관계)

  • Kim, Je-Hyeong;Jeong, Hye-Cheol;Kim, Kyung-Kyu;Lee, Sung-Yong;Kwon, Young-Hwan;Lee, So-Ra;Lee, Sang-Youb;Lee, Sin-Hyung;Cha, Dae-Ryong;Cho, Jae-Youn;Shim, Jae-Jeong;Cho, Won-Yong;Kang, Kyung-Ho;Kim, Hyoung-Kyu;Yoo, Se-Hwa;In, Kwang-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.2
    • /
    • pp.241-250
    • /
    • 1999
  • Background: Persistent nonproductive cough is a major adverse effect encountered with ACE inhibitor treatment and the most frequent reason for withdrawal of the drug. The mechanism of cough was postulated to be associated with accumulation of bronchial irritants which are substrates of ACE. It has been speculated that occurrence of this adverse effect is genetically predetermined ; in particular, variants of the genes encoding ACE. To investigate this relationship, we determined ACE gene Insertion/Deletion polymorphism in subjects with and without a history of ACE inhibitor-induced cough. Methods: Among the 339 patients with ACE inhibitor treatment, subjects who developed cough that resolved when not taking medication were designated to cough group and other subjects who did not complain cough were designated to non-cough group. Clinical characteristics of the patients were collected by review of medical records. ACE genotypes were determined by PCR amplification of DNA from peripheral blood and agarose gel electrophoresis. Results: 37 patients complained of dry cough(cough group) and 302 patients did not complained of cough(non-cough group). The incidence of ACE inhibitor induced dry cough was 10.9%. There was a preponderance of females in the cough group (M : F=24.3% : 75.7%) compared to the non-cough group (M : F=49.7% : 50.3%, p=0.004). There was no significant difference in mean age, underlying diseases, and kinds and frequencies of ACE inhibitors and their mean dosage between the both groups. ACE genotypic frequencies were I/I : I/D : D/D=16.2% : 18.9% : 64.9% in the cough group and 18.9% : 18.2% : 62.9% in the non-cough group which showed no significant difference between the both groups(p=0.926). Allelic frequencies were I : D = 25.7% : 74.3% and 28.0% : 72.0% in the cough and non-cough group respectively and the difference was not significant(p = 0.676). Conclusion: The incidence of ACE inhibitor-induced cough are 10.9%, and women are more susceptible to ACE inhibitor-induced cough. ACE inhibitor-induced dry cough is not associated with ACE gene Insertion/Deletion polymorphism.

  • PDF