• Title/Summary/Keyword: 연소 가스

Search Result 2,399, Processing Time 0.032 seconds

Concentration Distribution of PCBs in Soil Around Industrial Complex and Relationship with PCBs Sources (공단지역 주변 토양 중 PCBs 농도분포 및 발생원 추정에 관한 연구)

  • Park, Seok-Un;Kim, Kyoung-Soo;Kim, Jong-Guk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.5
    • /
    • pp.521-527
    • /
    • 2007
  • To investigate the relationship between PCB sources and concentration level in soil, PCBs concentration of 8 soil samples around Shiwa industrial complex were measured. The concentration of PCBs in soil samples were ranged from 2.43 to 274 ng/g dry (0.116 to 60.5 pg WHO-TEQ/g dry) md off-gas were ranged from 48.6 to $2872ng/m^3(0.00150\sim15.2ng\;WHO-TEQ/m^3)$; these are similar levels with results of previous study in Korea. The homologue patterns in soil samples were varied from sample to sample, but isomer patterns were very similar with each other. The two principal components were extracted by Principal Component Analysis(PCA) of 8 soil samples and cumulative factor loading was 95.7%. As the result of PCA, it could be expected that PCBs in soil samples of this study were more affected by PCB products than combustion process and mostly affected by already-known sources.

A Study on the Analysis of Polycyclic Aromatic Hydrocarbons in Air (대기중 다환 방향족 탄화수소류의 분석에 관한 연구)

  • Pyo, Hee-Soo;Hong, Jee-Eon;Lee, Kang-Jin;Park, Song-Ja;Lee, Won
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.453-465
    • /
    • 2000
  • Polycyclic aromatic hydrocarbons (PAHs) were produced by thermoreaction (incompletely combustion) of organic compounds such as fuel, gasoline, diesel etc, and were known the strong carcinogenic compounds. In our country, a study for health risk assessment of PAHs in air were needed according to rapidly increasing of motor vehicle and progressing to industrial country. In this study, concentrations of PAHs in 263 air samples of fourteen sites-Seoul, Pusan, etc-according to four times sampling for one year are measured by GC/MSD for basic research for health risk assessment. As the result, 14 PAHs are detected in all samples and annual average concentration of total PAHs was $28.72ng/m^3$ and highest average concentration of total PARs was $47.76ng/m^3$ in winter season. The concentrations of total PAHs are proportioned to amount of extracted organic material (EOM). The average concentration of total PAHs in EOM was 0.28%.

  • PDF

A study on permeation of $CO_2-N_2-O_2$ mixed gases through a NaY zeolite membrane under permeate evacuation mode (진공모드에서 NaY 제올라이트 막의 $CO_2-N_2-O_2$ 혼합기체의 투과거동 연구)

  • Jeong, Su Jung;Yeo, Jeong-Gu;Han, Moon Hee;Cho, Churl Hee
    • Membrane Journal
    • /
    • v.23 no.5
    • /
    • pp.352-359
    • /
    • 2013
  • In the present study, $CO_2$ permeation through a hydrophilic NaY zeolite membrane was studied under permeate evacuation mode for $CO_2$ single gas, $CO_2-N_2$ and $CO_2-O_2$ binary mixtures, and $CO_2-N_2-O_2$ ternary mixture. It was reconfirmed that the $CO_2$ permeation was governed by surface diffusion and the $CO_2$ selectivity was induced from blocking effect of adsorbed $CO_2$ molecules. The $CO_2$ permeance measured in permeate evacuation mode was much lower than that done in He sweeping mode, but was comparable to that obtained under feed pressurization mode. The NaY zeolite membrane showed a considerable $CO_2$ separation for $14%CO_2-80%N_2-6%O_2$ mixture : $CO_2$ permeance was about $1{\times}10^{-7}mol/m^2secPa$ and $CO_2$ selectivity was more than 10. Therefore, it was concluded that NaY zeolite membrane was one of promising membranes for post-combustion CCS process.

A numerical analysis study on the flammable volume by leakage of hydrogen fuel vehicles in parking lot (지하주차장 내 수소연료차의 수소 방출시 가연체적에 관한 수치해석적 연구)

  • Lee, Ho-Hyung;Kim, Hyo-Gyu;Yoo, Ji-Oh;Kim, Doo-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.6
    • /
    • pp.439-449
    • /
    • 2021
  • The recent reduction in greenhouse gases, interest in environmental pollution such as low-carbon emission policies is increasing. Accordingly, the penetration rate of eco-friendly vehicles, including hydrogen battery vehicles capable of reducing carbon emission, is increasing, and thus it is required for disaster prevention and safety-related measures. In this study, the degree of risk for the concentration distribution of hydrogen when leaking hydrogen fuel vehicles according to ventilation conditions was analyzed through numerical analysis, limited to places in parking lots. As a result, when only one hydrogen tank was released, the combustible volume ratio of hydrogen in the underground parking lot was up to 8.6%, and as ventilation continued, the volume ratio of combustible hydrogen decreased to less than 1% after 150 seconds, indicating that mechanical ventilation is essential. In the case of simultaneous release or stage release of three hydrogen tanks, the final combustible volume ratio of hydrogen is similar, but the increase in the combustible volume ratio of hydrogen in the early stage of release is low, and further research is expected.

A Study on the Characteristics of Coffee Ground(CG)-RDF by Using Different Drying Method (건조법에 따른 커피박 고형연료의 특성 고찰 연구)

  • Kim, Sang-bin;Ha, Jin-wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.451-457
    • /
    • 2019
  • In this study, the characteristics of coffee grounds were reviewed by making them from solid fuel through heat-drying and oil-drying method. The differences in the higher calorific power by each dried sample were compared. And industrial analysis using the thermogravimetric analyzer was considered for applicability to organic waste and oily samples. Before and after drying, the surface of the specimen was observed with SEM equipment and the ingredients were measured through the EDS equipment. As a result, no other hazardous substances, such as heavy metals, were measured. Next, The differences between thermal decomposition and combustion reactions were considered through the TG and DTG curves. As a result, it is that the oil-dried coffee grounds is longer to burn than the heat-dried coffee grounds. Finally, the combustion gases emitted through the thermogravimetric analyzer were collected and the carbon monoxide and carbon dioxide performed qualitative and quantitative analysis using GC over time.

Measurement of Sulfur Dioxide Concentration Using Wavelength Modulation Spectroscopy With Optical Multi-Absorption Signals at 7.6 µm Wavelength Region (7.6 µm 파장 영역의 다중 광 흡수 신호 파장 변조 분광법을 이용한 이산화황 농도 측정)

  • Song, Aran;Jeong, Nakwon;Bae, Sungwoo;Hwang, Jungho;Lee, Changyeop;Kim, Daehae
    • Clean Technology
    • /
    • v.26 no.4
    • /
    • pp.293-303
    • /
    • 2020
  • According to the World Health Organization (WHO), air pollution is a typical health hazard, resulting in about 7 million premature deaths each year. Sulfur dioxide (SO2) is one of the major air pollutants, and the combustion process with sulfur-containing fuels generates it. Measuring SO2 generation in large combustion environments in real time and optimizing reduction facilities based on measured values are necessary to reduce the compound's presence. This paper describes the concentration measurement for SO2, a particulate matter precursor, using a wavelength modulation spectroscopy (WMS) of tunable diode laser absorption spectroscopy (TDLAS). This study employed a quantum cascade laser operating at 7.6 ㎛ as a light source. It demonstrated concentration measurement possibility using 64 multi-absorption lines between 7623.7 and 7626.0 nm. The experiments were conducted in a multi-pass cell with a total path length of 28 and 76 m at 1 atm, 296 K. The SO2 concentration was tested in two types: high concentration (1000 to 5000 ppm) and low concentration (10 ppm or less). Additionally, the effect of H2O interference in the atmosphere on the measurement of SO2 was confirmed by N2 purging the laser's path. The detection limit for SO2 was 3 ppm, and results were compared with the electronic chemical sensor and nondispersive infrared (NDIR) sensor.

Degradation of Aqueous Monoethanolamine Absorbent (모노에탄올아민 흡수제의 열화특성 분석)

  • Cho, Youngmin;Nam, Sung-Chan;Yoon, Yeo-Il;Moon, Sungjun;Baek, Il Hyun
    • Applied Chemistry for Engineering
    • /
    • v.21 no.2
    • /
    • pp.195-199
    • /
    • 2010
  • The reversible chemical absorption using MEA (monoethanolamine), one of alkanolamine, is generally used as a conventionally method for $CO_{2}$ capture. Even MEA absorbent has excellent reactivity with $CO_{2}$, it has been known to have the decrease of absorption capacity caused by $CO_{2}$, $O_{2}$ or other acid gases in flue gas, corrosion and thermal degradation. In this study, MEA solutions degraded in the steam reforming process of refinery used and the absorption performance were compared for the used of conventional MEA solution. In case of 30 wt% MEA and mixture of 20 wt% thermal degraded absorbent (DP) and 10 wt% PZ, the absorption capacities were $0.5365mol-CO_{2}$/mol-absorbent and $0.5939mol-CO_{2}$/mol-absorbent respectively. PZ added thermally degraded absorbent showed the enhanced absorption capacity. On the contrary, the absorption rates were $1.1610kg_{f}/cm^2{\cdot}min$ for 30 wt% MEA, $0.5310kg_{f}/cm^2{\cdot}min$ for mixture of 20 wt% thermal degraded absorbent (DP) and 10 wt% PZ and $0.3525kg_{f}/cm^2{\cdot}min$ for 30 wt% thermally degraded absorbent only. The absorption rates of PZ added thermally degraded absorbent was higher than that of thermally degraded absorbent only. Therefore, it can be confirmed that thermally degraded absorbent can be reused as an absorbent for $CO_{2}$ by the addition of suitable additives.

The Simultaneous Absorption Rate of CO2/SO2/NO2 from Flue Gas with Aqueous Alkanolamine Solutions (알카놀아민 수용액을 이용한 연소배가스 중의 CO2/SO2/NO2 동시 흡수속도에 관한 연구)

  • Seo, Jong-Beom;Choi, Won-Joon;Kim, Jae-Won;Choi, Bong-Wook;Oh, Kwang-Joong
    • Korean Chemical Engineering Research
    • /
    • v.47 no.5
    • /
    • pp.639-645
    • /
    • 2009
  • In this study, alkanolamine was used to achieve high absorption rates for $CO_2$ as suggested at several literatures. The absorption rates of aqueous AMP and MEA solutions with $CO_2$, $SO_2$, $NO_2$ were measured using a stirredcell reactor. The reaction rate constants were determined from the measured absorption rates. The performances were evaluated under various operating conditions. As a result, the reactions with $SO_2$, $NO_2$ into aqueous AMP and MEA solutions were classified as an instantaneous reaction respectively. The absorption rates increased with increase of the reaction temperature and the concentration of absorbents. The simultaneous absorption rate of $CO_2/SO_2/NO_2$ into 3, 5, 10 wt.% MEA at various pressure of $CO_2/SO_2/NO_2$, was more increased 14~20% than AMP solution. We investigated the effect of $SO_2$ and $NO_2$ on the simultaneous absorption of $CO_2/SO_2/NO_2$ from a flue gas. The performances were evaluated under various operating conditions in order to investigate the absorption characteristic.

A Study on the Application of Marine Emulsion Fuel for Tier 3 Regulation (Tier 3 규제 대응을 위한 선박용 에멀젼 연료 적용성 연구)

  • Lee, Ki-Bong;Kim, Moon-Chan;Park, Hea Kyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.10
    • /
    • pp.671-677
    • /
    • 2012
  • In this study, the characteristics of emulsified fuel and engine emissions were studied with an engine dynamometer. In the results of physical property analysis, the margin of error of net calorific value and gross calorific value was ${\pm}0.5%$, were almost same theoretical calculation and results of physical property analysis test. In emulsified fuel, density and viscosity increased with increasing water contents. Emulsified fuel which is composed of water and Bunker-A was manufactured by using homogenizer and ultrasonic generator in $80^{\circ}C$. Phase separation did not take place in $20^{\circ}C$ and $50^{\circ}C$. In the results of engine dynamometer test, NOx concentration and smoke density were reduced with increasing water contents in using emulsified fuel. Total NOx could be reduced by about 41%, 10%, 32% and 28% at 1,000 rpm, 1,200 rpm, 1,500 rpm and 2,500 rpm respectively. Total smoke density was reduced to 42%, 65%, 70%, 62%, and 82% at 1,000 rpm, 1,200 rpm, 1,500 rpm, 2,000 rpm, and 2,500 rpm respectively.

Flame and Carbonization Patterns of Animal-Origin Foods Ignited by Overheating (과열에 의해 발화된 동물성 식품의 화염 및 탄화 패턴에 관한 연구)

  • Lee, Jeong-Hun;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.126-131
    • /
    • 2019
  • Real-scale fire tests were performed on animal-origin foods using a gas stove with no overheating prevention device. When the animal-origin foods were ignited, a large quantity of white smoke and steam was generated from them; however, when they became dry and began to carbonize, a dark smoke was generated. Even after the gas stove was overheated for more than 5400 s, mackerel, pollack, chicken, etc., did not ignite. However, pork, beef, and tuna caught fire after 2643 s, 2819 s, and 6492 s of heating, respectively. The flame patterns of animal-origin foods were in the forms of a mixed laminar flow and a turbulent flow, and a halo pattern was produced. A sand glass form of the flame pattern was generated when a kitchen hood was operated, but a triangular flame pattern was produced when the kitchen hood was not operated. When the tuna in the pot was overheated, it spontaneously ignited after 6492 s, with the surface temperature of the kitchen hood rapidly rising to 464.5 ℃. Moreover, the temperature at the back of the pot, which was 6 cm away from the outer surface of the upper part of the pot, was 869 ℃ after 6660 s because of the radiant heat. The flame formed a sand glass pattern on the kitchen wall. When the kitchen hood was not operated, or when the flame grew lower than the height of the ceiling, a triangular pattern was formed.