• Title/Summary/Keyword: 연소도

Search Result 8,693, Processing Time 0.036 seconds

A Clinical Study of Acute Colonic Diverticulitis in Children (소아에서 발생한 급성 대장 게실염의 임상적 고찰)

  • Sim, Jae Hoon;Song, Keum Ho;Sim, Yun Jung;Cho, Do Jun;Kim, Dug Ha;Min, Ki Sik;Yoo, Ki Yang;Lee, Hae Ran;Lee, Kwan Seop
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.11
    • /
    • pp.1095-1100
    • /
    • 2003
  • Purpose : Children with acute colonic diverticulitis(ACD), can be misdiagnosed with acute appendicitis. Methods : We reviewed 15 cases of ACD during five years, from January 1998 to June 2002 retrospectively. Results : Most patients(80%) with ACD in children presented with right lower quadrant pain. The primary diagnosis on admission was mostly acute appendicitis(87%), and all ACD in children occurred in the right colon. Fourteen patients were managed by conservative treatment including antibiotics. A follow-up study was performed in 15 patients. There were symptomatic recurrences in two patients, but no significant complication was noted. The frequency of ACD was 11.7 per 1000 acute appendicitis. Conclusion : ACD in children can mostly be cured by conservative treatment. It is prudent to choose the management through the diagnostic work up, including abdominal sonography and computed tomography, because there was no significant difference of clinical findings between ACD and acute appendicitis.

Estimation of fire Experiment Prediction by Utility Tunnels Fire Experiment and Simulation (지하공동구 화재 실험 및 시뮬레이션에 의한 화재 설칠 예측 평가)

  • 윤명오;고재선;박형주;박성은
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.23-33
    • /
    • 2001
  • The utility tunnels are the important facility as a mainstay of country because of the latest communication developments. However, the utilities tunnel is difficult to deal with in case of a fire accident. When a cable burns, the black smoke containing poisonous gas will be reduced. This black smoke goes into the tunnel, and makes it difficult to extinguish the fire. Therefore, when there was a fire in the utility tunnel, the central nerves of the country had been paralyzed, such as property damage, communication interruption, in addition to inconvenience for people. This paper is based on the fire occurred in the past, and reenacting the fire by making the real utilities tunnel model. The aim of this paper is the scientific analysis of the character image of the fire, and the verification of each fire protection system whether it works well after process of setting up a fire protection system in the utilities tunnel at a constant temperature. The fire experiment was equipped with the linear heat detector, the fire door, the connection water spray system and the ventilation system in the utilities tunnel. Fixed portion of an electric power supply cable was coated with a fire retardant coating, and a heating tube was covered with a fireproof. The result showed that the highest temperature was $932^{\circ}c$ and the linear heat detector was working at the constant temperature, and it pointed at the place of the fire on the receiving board, and Fixed portion of the electric power supply cable coated with the fire retardant coating did not work as the fireproof. The heating tube was covered with the fireproof about 30 minutes.

  • PDF

Distribution Characteristics of Polycyclic Aromatic Hydrocarbons(PAHs) in Riverine Waters of Ulsan Coast, Korea (울산연안 하천에서 다환방향족탄화수소 분포특성)

  • You, Young-Seok;Lee, Jeong-Hoon;Park, Jeong-Chae;Kim, Dong-Myung;Cho, Hyeon-Seo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.5
    • /
    • pp.398-405
    • /
    • 2012
  • PAHs(Polycyclic Aromatic Hydrocarbons) in coastal area and estuary adjacent to urban area and industrial activities region are mainly introduced into marine environment via atmosphere and river. This study which is evaluated the distribution characteristics of PAHs discharge from rivers and sewage disposal water which flowing into Ulsan bay, and were carried out in Jun of dry season and in Auguest of wet season, 2008. The water samples from eight main rivers and Youngyeon WWTP(Wastewater Treatment Plant) flowed into Ulsan bay were taken for analysis of dissolved PAHs. The range and mean values of dissolved PAHs concentrations showed 10.30 to 87.88 ng/L, its mean 36.94 ng/L in dry season and 10.30 to 69.57 ng/L, its mean 24.37 ng/L in wet season. The distribution of dissolved PAHs showd the high concentrations in the Gungcheoncheon which is flowed from urban and industrial area. The ranges and means values of the loading fluxes were estimated with 0.04 to 8.27 g/day, its mean 2.05 g/day in dry season, and 0.03 to 4.77 g/day, its mean 1.61 g/day, in wet season. The loading flux showed the highest value in Taewha river due to the high flow rate and the urban activity. The composition patterns of dissolved PAHs compound showed most of the trend occupying low molecuar weight PAHs than high molecular weight PAHs. These results were due to physical and chemical characteristics of PAHs compound, and were similar to those of other studies. The concentrations of dissolved PAHs in this study are lower than those of other studies, and the level of PAHs pollution appeared to be not serious in reverine waters of Ulsan coast.

Growth and Production of Mactra veneriformis (Bivalvia) on the Songdo Tidal Flat, West Coast of Korea (서해 송도 갯벌에서의 동죽(Mactra veneriformis: Bivalvia)의 성장과 생산)

  • 신현출;고철환
    • 한국해양학회지
    • /
    • v.30 no.5
    • /
    • pp.403-412
    • /
    • 1995
  • The present study was performed to determine th growth and production of Mactra veneriformis on the Songdo tidal flat off Inchon. west coast of Korea. Monthly samples were collected from Marc 1989 to September 1990. The size distributions of shell length showed unimodal patterns from March to August 1989. The binodal pattern after September 1989 indicated a recruitment of young clams during this period. The density fluctuated irregularly, but showed a decreasing pattern over time on the whole. The density of the year class 1989 increased markedly after February 1990. The growth in shell length showed three phases during a year, a fast growth phase in spring, a slow growth phase in summer and autumn, and a lag phase in winter. The annual increment in shell length reduced with age. The flesh dry weight showed a peak in late spring just before the spawning period, and another peak in autumn. The length of annuli and the back-calculated flesh dry weight were used to describe the annual growth. The growth in shell length fitted to the von Bertalanffy model and the flesh dry weight to the Gompertz model. The absolute growth rate of the shell length reduced gradually with age. The year class 1985 had the highest L, and the yeat class 1986 the lowest L. The annual growth in weight showed a typical sigmoid curve. The growth rate was maximum at the age of 2 to 3. Year classes of 1984 and 1985 had higher values of W and higher absolute growth rates than those of 1986 and 1987. Maximum absolute growth rates of 1986 and 1987 year classes were recorded at younger ages than 1984 and 1985 year classes. The annual relative growth rates of length and weight decreased exponentially with age. Biomass in flesh dry weight increased till spring and thereafter decreased progressively. Maximum biomass was 134.6g m/SUP -2/ in August 1990. The biomass of 1989 yeat class occupied highest proportion in total biomass. Annual production in flesh dry weight from March 1989 to March 1990 was 67.9 g m/SUP -2/ year/SUP -1/. Cumulative production of 1989 year class was highest among all year classes, and that of year class 1984 was lowest. The production is high in spring and autumn, and very low in summer and winter.

  • PDF

Exposure Assessment for Polycyclic Aromatic Hydrocarbons in the Model Menu System of Korean (한국인의 모델식이에 대한 다환방향족탄화수소류(PAHs)의 인체노출량평가)

  • Kim YunHee;Yoon EunKyung;Lee HyoMin;Park KyungAh;Jun EunAh;Lee CherlHo;Choi SangYun;Lim SeungTaek;Ze KeumRyun;Choi KwangSik
    • Journal of Food Hygiene and Safety
    • /
    • v.19 no.4
    • /
    • pp.176-184
    • /
    • 2004
  • This study was conducted to compare and estimate the daily PAHs dietary intake from both home-cooking and dining-out, through approach of model diet used in exposure assessment of food contaminants. Food commodities reflecting in model diet were selected from the KHIDI report and were analysed in cooked or uncooked edible forms using HPLC-Fluorscence Detector. The PAHs dietary intake comparison between home-cooking and dining-out was based on one meal intake suggested in model diet and PAHs dietary intake was estimated by using food consumption rate and body weight of the Korean adult group. The daily PAHs dietary intake was calculated by permutation and combination method with assumption that a person consumed 2 meals from home-cooking menu and 1 meal from dining-out menu. The total PAHs levels in 36 food commodities with 200 samples were ranged from 2.00 ug/kg to 141.28 ug/kg and a food showing the highest PAHs level was the stir-fried anchovy. The $TEQ_{BaP}$ levels of PAHs were calculated using benzo(a)pyrene equivalents individual congener level and corresponding TEF value and the $TEQ_{BaP}$ level were ranged from $0.03\;ugTEQ{BaP}$ to $1.31\;ugTEQ_{BaP}$ and a food showing the highest $TEQ_{BaP}$ level was the hamburger. The PAHs dietary intakes per one meal from home-cooking and dining-out were $2.4\times10^{-3}\;ugTEQ_{BaP}/kg/meal\;and\;4.0\times10^{-3}\;ugTEQ_{BaP}/kg/meal$, respectively. This data showed the PAHs dietary intake from dining-out was about 1.7 times higher than from the home-cooking. The daily PAHs dietary intakes of general Korean adult having two meals from home-cooking and one meal from dining-out per a day were ranged between $8.0\times10^{-3}\~9.7\times10^{-3}\;ugTEQ_{BaP}/gg/day$ and mean value as $8.9\times10^{-3}\~9.7\times10^{-3}\;ugTEQ_{BaP}/gg/day$.

Allogeneic Hematopoietic Stem Cell Transplantation in Juvenile Myelomonocytic Leukemia (연소형 골수단구성 백혈병에서의 동종 조혈 모세포 이식)

  • Yoo, Keon Hee;You, Dong Kil;Lee, Soo Hyun;Sung, Ki Woong;Cho, Eun Joo;Koo, Hong Hoe
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.2
    • /
    • pp.178-185
    • /
    • 2005
  • Purpose : The purpose of this study was to evaluate the outcome of children with juvenile myelomonocytic leukemia(JMML) treated with allogeneic hematopoietic stem cell transplantation(allo-HSCT). Methods : Eleven JMML patients aged 8-39 months underwent allo-HSCT. The sources of grafts were unrelated donors(n=7), HLA-matched siblings(n=3) and an HLA 1-antigen mismatched familial donor. All patients had received chemotherapy ${\pm}13$-cis-retinoic acid(CRA) before transplant, and CRA was used, posttransplant, in six patients. Results : Only three patients were in complete remission(CR) at the time of transplantation. Initial chimeric status revealed complete donor chimerism(CC) in five patients, mixed chimerism(MC) in five and autologous recovery(AR) in one. One patient with MC having persistent splenomegaly eventually turned to CC and CR after rapid tapering of cyclosporine, combined with daily use of CRA. An AR case relapsed shortly after transplant but was rescued with second, unrelated cord blood transplantation. Ultimately, six patients are alive, event-free, with a median follow-up of 15.5 months posttransplant. All three deaths occurred in patients who failed to achieve CC, leading to disease progression. Conclusion : We suggest that graft-versus-leukemia effect play an important role and CRA a possible role in posttransplant leukemic involution in JMML. In patients whose leukemic burden is still high with MC after transplant, early tapering of immunosuppressants and introduction of CRA might provide a chance of a cure for some patients.

Effect of Added NH$_3$ to AMP on Absorption Rate for Simultaneous Removal of CO$_2$/NO$_2$ in Composite Absorption Process (복합흡수공정에서 CO$_2$/NO$_2$ 동시제거 시 AMP(2-amino-2-methyl-1-propanol)에 Ammonia 첨가가 흡수속도에 미치는 영향)

  • Seo, Jong-Beom;Choi, Won-Joon;Moon, Seung-Jae;Lee, Gou-Hong;Oh, Kwang-Joong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.12
    • /
    • pp.1287-1293
    • /
    • 2008
  • In this study, a blend of 2-amino-2-methyl-1-propanol (AMP) and ammonia (NH$_3$) was used to achieve high absorption rates for carbon dioxide (CO$_2$) as suggested at several literatures. The absorption rates of aqueous AMP and blended AMP+NH$_3$ solutions with CO$_2$ and nitrogen dioxide (NO$_2$) were measured using a stirred-cell reactor at 303 K. The effect of the added NH$_3$ to enhance absorption characteristics of AMP was studied. The performances were evaluated under various operating conditions. The absorption rates increased following the increase of the concentration of NH$_3$. The absorption rate of NH$_3$ blended into 30 wt.% AMP solution with NO$_2$ at 303 K was 12.6$\sim$32.6% higher than that of aqueous AMP solution without NH3. Also, the addition of 3 wt.% NH$_3$ to 30 wt.% AMP increased 48.2$\sim$41.6% values for the reactions with CO$_2$ and NO$_2$ at 303 K. Therefore, it clearly shows that the reaction rate of AMP with CO$_2$ and NO$_2$ can be increased by the addition of NH$_3$.

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

A Comprehensive Study on the Forced Aging of Flue-cured Tobacco-Leaves (황색종 잎담배의 발효숙성 촉진에 관한 종합적 연구)

  • Bae, H.W.
    • Applied Biological Chemistry
    • /
    • v.13 no.1
    • /
    • pp.1-27
    • /
    • 1970
  • The process of the forced aging of flue-cured tobacco leaves were studied extensively from various scientific points of view. The Flue-cured tobacco leaves were inoculated and fermented with nicotine resistant Hansenula yeast, or the leaves were subjected under simple forced aging. The above two processes of forced aging were studied from the summarized points of microbiology, physics, chemistry, and biochemistry, and the resulted products ware compared in their physical, chemical and biochemical quality determining factors with that of raw material tobacco leaves (dried-tobacco leaves) and 2 years aged high quality tobacco leaves. The summary results were as follows. 1) The Korean flue-cured tobacco leaves, were forcedly aged under the basic optimum aging condition, temperature $40^{\circ}C$, moisture contents 18%, relative humidity 74%. It was found that this aging condition was the best in bringing the quality of forcedly aged tobacco leaves to the utmost state. 2) Under this optimum temperature and moisture condition of forced aging in about 20 days the forcedly aged tobacco leaves both with yeast inoculation and without yeast inoculation showed the equivalent tobacco qualities comparable with that of more than 2 years aged tobacco leaves. 3) The forcedly aged tobacco leaves both with and without yeast inoculation under $40^{\circ}C$ temperature and $74^{\circ}C$ relative humidity achieved the necessary quality determining physical and chemical changes in about 20 days. 4) The microbial changes during the forced aging were as follows. The population of yeasts and bacteria increased until to 15 days of aging, then decreased thereafter. Whereas the molds grew continously until the end of fermentation. 5) The tobacco quality determing physico-chemico-properties of yeast inoculated aged and simple forcedly aged tobacco leaves, progressed as the follows in time. As the forced aging progresses, swelling and combustibility properties were improved. The pH, total reducing materials, total sugars, alkaloids contents decreased. The contents of organic and ether extractable materials increased. The total nitrogen, protein, crude fiber, ash contents showed no changes. The color properties, excitation purity, luminance, main wave length, showed equivalent changes comparable with that of 2 years aged tobacco leaves. 6) The changes in chemical components in yeast treated and simple forcedly aged tobacco leaves during $15{\sim}20{\;}days$ of forced aging were as follows. The following chemical components decreased as the aging. Sugars-sucrose. rhamnose, glucose. Pigments-chlorophyll, carotenes, xanthophyll and violax anthine. Polyphenols-rutin, chlorogenic and, coffeic acid. Organic acids-iso-butylic, crotonic, caprylic, galacturonic, tartaric, succinic, citric acid. Alkaloids-nicotine, nornicotine. The following components increased as the forced aging progressed. Sugars-frutose, maltose, raffinose. Amino acids-proline, cystine. Organic acids-formic, acetic, propionic, n-butyric, iso-valeric, n-valeric, malic, oxalic, malonic, ${\alpha}-ketoglutaric$, fumaric, glutaric acid. 7) During the forced aging of tobacco Leaves the oxygen-uptake decreased gradually. The enzyme activities of polyphenol oxidase, ${\beta}-amylase$ ${\alpha}-amylase$ decreased gradually. The activities of the enzymes, catalase, and invertase increased once then decreased at the later stage.

  • PDF

Firefighters' Exposures to Polynuclear Aromatic Hydrocarbons and Volatile Organic Compounds by Tasks in Some Fire Scenes in Korea (일부 화재현장에서 소방공무원의 직무별 다핵방향족탄화수소 및 휘발성유기화합물 노출평가)

  • Jin, Suhyun;Byun, Hyaejeong;Kang, Taesun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.4
    • /
    • pp.477-487
    • /
    • 2019
  • Objectives: Firefighters are known to be exposed to a variety of toxic substances, but little information is available on the exposure profile of firefighting activities. The aims of this study were to conduct exposure monitoring of toxic chemicals at fire scenes, to compare the concentrations of respective chemicals among firefighting tasks, and to assess the main factors influencing the concentrations of chemicals. Methods: Researchers performed sampling at firefighting scenes during four weeks in 2013. At the scene, we collected samples based on firefighters' own activities and examined the situation and scale of the accident. Collected samples were classified into three categories, including fire extinguishing and overhaul, and were analyzed in the laboratory according to respective analysis methods. Results: A total of fourteen fire activity events were surveyed: five fire extinguishing, six overhaul, and three fire investigations. Although no substance exceeded the ACGIH TLV, PAHs were detected in every sample. Naphthalene ranged from 0.24 to 279.13 mg/㎥ (median 49.6 mg/㎥) and benzo(a)pyrene was detected in one overhaul case at 10.85 ㎍/㎥. Benzene (0.01-12.2 ppm) was detected in every task and exceeded the ACGIH TLV. No significant difference in concentrations between tasks was shown. Conclusions: These results indicate that all firefighting tasks generated various hazardous combustion products, including possible carcinogens.