• Title/Summary/Keyword: 연무

Search Result 102, Processing Time 0.048 seconds

Comparison of the Characteristics of 16 Commercial Nebulizer/Compressor Combinations Used in Korea (국내 시판되는 16가지 연무기/압축기의 성능 평가)

  • Kim, Hyun Jung;Lee, Cho Ae;Hwang, Eun Kyung;Han, Man Young;Ann, Uk Sung;Cho, Young Min
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.12
    • /
    • pp.1235-1241
    • /
    • 2003
  • Purpose : We assessed the dynamic characteristics of 16 nebulizer/compressor combinations currently available in Korea. Methods : The 16 nebulizer/compressor combinations(Pariboy Type 38/Long life, Pariboy Type N/Long life, Pariboy Type N/Salter 8900, Pariboy Type N/LC, Devilbiss pulmoaid-LT/Hudson, Devilbiss pulmoaid/Hudson, Mesmed neb-300/Own, San-up 3040/Hudson, Midas(Basic)/Own, AirJolie 2/Hudson, Thomas 1127/Salter 8900, Noel NE-2000/Salter 8900, Omron CX3/Hudson, Chang Woo CWN-100/Salter 8900, Voyage/Mefar, Chang Woo ASI-Pro/Medel jet pulse) were evaluated in terms of particle size and mass output. In addition, we determined the effects of nebulizer fill volume on mass output. Results : Pariboy Type N/Long life has the highest respirable mass of 0.184 mg/min and Mesmed Neb-300/Own has the lowest 0.019 mg/min. Pariboy Type N/Long life has the highest mass output of 0.68 mg/min and the shortest mass median aerodynamic diameter(MMAD) of $3.76{\mu}m$. All combinations other than Pariboy Type N/Long life produced a MMAD of over $5{\mu}m$. MMAD over a 5 min nebulization ranged 3.76 to $9.83{\mu}m$. There were no significant effects of fill volume on mass output. Conclusion : We concluded that there is a wide variation in performance of nebulizer/compressor combinations. The characteristics of nebulizer/compressor combinations should be considered in selecting products.

Male Parental Care, Egg and Larval Development of the Smoky Damselfish, Chromis fumea (Pisces: Pomacentridae) (연무자리돔, Chromis fumea (Pisces: Pomacentridae)의 산란보호, 난발생 및 자어의 형태발달)

  • Kim, Jin-Koo;Kim, Yong-Uk;Park, Jin-Woo
    • Korean Journal of Ichthyology
    • /
    • v.13 no.3
    • /
    • pp.166-172
    • /
    • 2001
  • Parental care of eggs of Chromis fumea (Tanaka) was observed by Skin Scuba gear in August 1995 off Cheju Island. The eggs and larval development were observed in the laboratory at Pukyong National University, Pusan. Eggs were deposited on a flat surface of hard substratum and formed a plain sheet of one layer of eggs. Males showed parental care of the eggs by hovering over the nest and attacking other fishes that approached the nest. The spawned eggs were transparent, elliptical in shape and measured 0.73~0.88 mm in long axis and 0.50~0.56 mm in short axis. An analysis by T-test of the long axis of the egg with time showed a significant difference (p<0.01). However, there was no significant difference in short axis with time. Eggs were reared at water temperatures of $23.0{\sim}25.5^{\circ}C$ and took about 4~5 days from embryonic body stage to hatching. The newly hatched larvae were 1.10~1.61 mm in notochord length (NL) had 21 myomeres, has closed mouth but open anus, preanus length was 45.8% of NL. Melanophores were distributed on the occipital region of head, the eye, the peritoneal region, and along the ventral contour. The larvae absorbed the yolk material and oil globule in 3~4 days after hatching and became postlarvae. On the third day after hatching, the larvae had attained 1.9~2.4 mm in NL, had 25 myomeres, and showed rapid growth. By the ninth day after hatching, the larvae had attained 2.9 mm in NL, had an swimbladder in the dorsal margin of ventral region, the preanus length was 37.9% of NL, and their melanophores were enlarged and reduced in number.

  • PDF

Compositions of haze aerosols and their variation by inflow pathway of air mass at Gosan site in Jeju Island during 2012-2013 (연무 에어로졸의 조성 및 기류 유입경로별 변화: 2012-2013년 제주도 고산지역 측정)

  • Hyeon, Dong-Rim;Song, Jung-Min;Kim, Ki-Ju;Kim, Won-Hyung;Kang, Chang-Hee;Ko, Hee-Jung
    • Analytical Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.213-222
    • /
    • 2014
  • The atmospheric aerosols of $PM_{10}$ and $PM_{2.5}$ were collected at Gosan site of Jeju Island during 2012- 2013. Their ionic and elemental species were analyzed in order to examine the composition variation of the haze aerosols in accordance with the pathway of air mass. The concentrations of $nss-SO_4{^{2-}}$, $NO_3{^-}$, and $NH_4{^+}$ increased 2.1~3.7 times in coarse particle and 3.1~6.5 times in fine particle modes, respectively, showing especially high $NO_3{^-}$ concentrations in fine particles during the haze days. The concentrations of S, Zn, Pb and K increased 3.0~5.6 times in coarse particles and 3.2~7.7 times in fine particles during the haze days, on the other hand Al, Fe, and Ca concentrations were high only in coarse particles. Due to the back trajectory analysis, the concentrations of $nss-SO_4{^{2-}}$ and $NO_3{^-}$ for haze days were high when the inflow pathway of air mass was from China, especially a high increase of $NO_3{^-}$ as through the south of China. The $NO_3{^-}/nss-SO_4{^{2-}}$ concentration ratio was relatively high in coarse mode as air mass inflow from China, but in fine mode it was high as air mass passing through the Korean peninsula.

A Report on the Control Effects of Automatic Dry Fog Sprayer on Aphids in Greenhouse Crops (시설 온실에서 진딧물에 대한 무인 연무방제기의 방제 효과 보고)

  • Kang, Taek-Jun;Kim, Se-Jin;Kim, Dong-Hwan;Yang, Chang Yeol;Kim, Hyeong-Hwan;Cho, Myoung-Rae
    • Korean journal of applied entomology
    • /
    • v.53 no.4
    • /
    • pp.479-483
    • /
    • 2014
  • The area of greenhouse horticulture has increased dramatically since the early 1990s in Korea. However, area per farmer still very small and diverse pest species occurs in greenhouse abundantly because of its protected condition. To manage pests, farmers use many pesticides frequently. Incessant and improper use of chemicals provoked pesticide resistance in pest and poisoning of farmers. In this study, we investigated the efficiencies of automatic dry fog sprayer for controlling two aphid species, Aphis gossypii and Myzus persicae, in greenhouse horticulture. When doors and side windows were completely closed in automatic dry fog sprayer treatment greenhouse, aphids were controlled similar level with conventional spraying method (percent control: 61.0~94.1%). However, when half of the doors and side windows of the greenhouse were opened, aphids were controlled poorly (percent control: 36.0~54.4%).

The Froude Scaling Study on the Ventilation of Non-isothermal Concentrated Fume from the Semi-closed Space (반밀폐형 공간에서 비등온 고농도 연무의 배연산출량 산정을 위한 Froude 상사연구)

  • Chang, Hyuk-Sang;Choi, Byung-Il;Park, Jae-Cheul;Kim, Myung-Bae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.8
    • /
    • pp.877-885
    • /
    • 2005
  • The Froude scaling between the prototype and the model was tried to estimate the necessary ventilation rate for non-isothermal concentrated fume from the semi-closed inner space. Based on the non-dimensional similitude equations derived from the Zukoski plume rise analysis, the scaling experiments were done to verify the relationship of the non-dimensional energy release rate and the non-dimensional mass flow rate by using two different scaled volume models, model A ($1\;m{\times}1\;m{\times}1\;m$) and model B ($0.5\;m{\times}0.5\;m{\times}0.5\;m$). The experimental results showed that the theoretical similitude between the models is acceptable for the prediction of ventilation rate of the concentrated fume. The maximum energy release rate used for the experiments was $20\;kW/m^3$. In the experimental range, the similitude between the energy release rate and the ventilation mass flow rate was well defined and the necessary ventilation rates were 20-30% higher than the stoichiometric ventilation mass flow rate. Based on results of current study, the design of the local air ventilation system can be improved by correcting the effects of buoyancy and diffusion of the non-isothermal concentrated fume.

Prestenotic Bronchial Radioaerosol Deposition: A New Lung Scan Sign of Bronchial Obstruction (기관지 협착 근위부의 연무 침착: 폐스캔에서 기관지 폐색의 특이한 지표)

  • Chung, Soo-Kyo;Kim, Hak-Hee;Choi, Byung-Gil;Lee, Sang-Hoon;Kang, Si-Won;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.3
    • /
    • pp.307-312
    • /
    • 1995
  • The present study has been carried out to assess the diagnostic usefulness of radioaerosol lung scan in complete bronchial obstruction (n=7) and bronchial narrowing (n=1) of varying causes. $^{99m}Tc$-phytate lung scan was performed using the aerosol generated by a BARC nebulizer. Scan alterations were correlated with those of chest radiography, bronchography, lung CT and/or brochoscopy. In every case scan showed characteristic intense deposition of radioaerosol in a short slightly dilated, bronchial segment immediately proximal to obstruction or stenosis. Characteristically it was accompanied by an airspace aerosol deposition defect distally. The finding of a short, clubbed, bronchial radioaerosol deposition with distal airspace defect is a sensitive, specific indicator of bronchial obstruction or stenosis. It was especially useful in the detection of the obstruction of a small bronchus at the lobar and sublobar levels. We propose to name it the prestenotic aerosol deposition sign.

  • PDF

A Study on the Spray Characteristics of the Cold-Fog Spray with Ultrasonic Forcing (초음파적용 상온연무기의 분무특성에 관한 연구)

  • Song Min-Geun;Lee Kyung-Youl;Son Sung-Woo;La Woo-Jung;Ju Eun-Sun
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.299-302
    • /
    • 2002
  • Characteristics of the twin fluid spray with ultrasonic forcing are examined in order to obtain the high efficiency of cold fog spray of the automatic pest control machine which has been widely used for the equipment cultivation recently. An electrostrictive vibrator of PZT BLT and a magnetostrictive vibrator of ${\pi}type$ with 28 kHz are applied as the ultrasonic transducer. All experiments are made and observed in 4 methods of spray ; a conventional spray method without ultrasonic forcing, an indirect vibration method with ultrasonic forcing, an improving duality method by ultrasonic forced within liquid, and a combined use method with both of the indirect vibration method and the improving quality method. In results, It was clarified that the ultrasonic effects the atomization of spray droplets and its efficiency is about $10{\%}$ and especially much more in the case of the combined use method.

  • PDF