• Title/Summary/Keyword: 연마지

Search Result 145, Processing Time 0.044 seconds

Influencing factors for abrasive flow rate and abrasive flow quality of abrasive injection waterjet systems for tunnel excavation (터널굴착용 투입형 연마재 워터젯 시스템의 연마재 투입량과 유동성에 미치는 영향 인자)

  • Joo, Gun-Wook;Oh, Tae-Min;Cho, Gye-Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.4
    • /
    • pp.417-430
    • /
    • 2014
  • A new rock excavation method using an abrasive waterjet system is under development for efficiently creating tunnels and underground spaces in urban areas. In addition, an appropriate abrasive flow rate and abrasive flow quality are important for the new rock excavation (cutting) method using an abrasive waterjet system. This study evaluated the factors influencing the abrasive flow rate and abrasive flow quality, specifically the abrasive pipe height, length, tortuosity and inner diameter, through experimental tests. Based on the experimental test results, this study suggested optimal conditions for the abrasive flow rate and abrasive flow quality. The experimental results can be effectively utilized as baseline data for rock excavation methods using an abrasive waterjet system in various construction locations such as tunnels near urban surroundings, utility tunnels, and shafts.

Appling of Force Control of the Robotic Sweeping Machine for Grinding (연마작업을 위한 로봇형 연마기의 힘제어 적용)

  • Jin, Taeseok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.2
    • /
    • pp.276-281
    • /
    • 2014
  • In this research, we describe a force feedback control for industrial robots has been proposed as a system which is suitable to work utilizing pressure sensitive alternative to human. Conventionally, polished surface of the workpiece are recognized, chamfer ridge, machining processes such as deburring, and it is most difficult to automate because of its complexity, has been largely dependent on the human. To aim to build automatic vacuum system robotic force control was gripping the grinding tool, the present study we examined the adaptability to the polishing process to understand the characteristics of the control system feedback signal obtained from the force sensor mainly. Furthermore, as a field, which holds the key to the commercialization, I went ahead with the application to robotic sweeping machine. As a result, the final sweeping utilizing a robot machine to obtain a very good grinded surface was revealed.

Prevention of Candida albicans infection in dental polishing lathe by chlorhexidine (클로르헥시딘을 이용한 치과기공용 연마기 캔디다균의 감염방지)

  • Song, Young-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.4
    • /
    • pp.274-279
    • /
    • 2016
  • Purpose: The purpose of this study was to evaluate the transmission of candida in denture by dental polishing lathe. Materials and Methods: Maxillary complete dentures made from the same model were infected with Candida albicans. Polishing wheels were keep in various chlorhexidine solution and distilled water for an hour. The infected dentures were polished by prepared dental polishing lathe with sterile pumice and distilled water. And then sterile maxillary complete dentures were polished with same method. Polishing surface was wiped with a cotton swab and the sample was regrown for checking Candida albicans. Results: All polishing wheel with chlorhexidine resist fungal infection. But the polishing wheel with distilled water is infected with Candida albicans. Conclusion: A chlorhexidine is highly efficient in fungal infection prevention on dental polishing lathe.

Study on Scintillator Polishing Technology for Increasing the Detection Efficiency of Radiation Detectors Using Plastic Scintillators (플라스틱 섬광체를 이용한 방사선 검출기의 검출 효율을 높이기 위한 섬광체 연마 기술 연구)

  • Kim, Jeong-Ho;Joo, Koan-Sik
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.456-462
    • /
    • 2014
  • Scintillators were polished in four steps using polishing paper, to reduce the optical loss occurring at their cross section when radiation detectors are fabricated with plastic scintillators. We studied the correlation between the polishing steps and detection efficiency and assessed the detection characteristics that are dependent in the polishing steps. Our results showed that the detection efficiency increased by approximately 7.75 times for a detector that used a scintillator polished in four steps, compared to a detector that used an depolished scintillator. For detectors fabricated using scintillators polished in different steps, better detection characteristics were obtained in terms of the activity, distance, and location of radiation, compared to detectors fabricated with an depolished scintillator.

Performance Improvement based on the Teaching Control for Sweeping Robot (연마로봇의 교시기반 제어에 의한 성능개선)

  • Jin, Taeseok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.7
    • /
    • pp.1525-1530
    • /
    • 2014
  • In this research, we describe teaching based sweeping control for grinder robot has been proposed as a system which is suitable to work utilizing pressure sensitive alternative to human. Teaching method is used for grinder robots operations because of their position accuracy, path accuracy, and machining reaction force. A grinder robot for two-dimensional iron plate was developed on the basis of an force sensor based teaching method. An automatic-path-generation method and experimental results using specific points was adopted to reduce the number of teaching points and time. And also, in order to determine the proper machining conditions, various machining conditions such as grinder-wheel rotation speed and robot moving speed, were evaluated.

Evaluation of Surface Condition and Food Solution on the Color Stability of Dental Restoration Materials (표면 상태와 용액에 따른 치과용 수복재료의 색안정도 평가)

  • Woo, Hee-Sun;Kim, Hyo-Jin;Jun, Soo-Kyung
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.4
    • /
    • pp.359-367
    • /
    • 2019
  • For this study, specimens were prepared using five types of composite resin and resin-reinforced glass ionomer Fuji II LC, and 29 days precipitation was done in four kinds of solution, which were soy sauce, gochujang, wine, and distilled water. Ten specimens for each coloring sample were divided into two groups, one those surfaces was polyester film and the other with 1200-grit abrasive paper, and 20 specimens per materials. Color change (${\Delta}{\ast}ab$) in the colored specimens is measured in 2days, 7days, 14days and 29days using spectrophotometer (CM-2600d, Konica, Minolta, Ramsey, NJ). All values were considered significant when P<0.05. 1. Each material is discolored over time under the influence of different storage solutions. 2. In soy source, among the specimens polished with polyester film, color change was observed in resin-modified glass ionomer Fuji II LC, prodigy and compomer F-2000 on day 2. Meanwhile, Fuji II LC showed noticeable color change in specimens prepared with 1200-grit sandpaper on day 2, which was followed by flowable resin on day 7. 3. On day 2, there was a color change with the specimens of flowable resin, resin-modified glass ionomer Fuji II LC and Prodigy among the hybrid specimen in the groups of polyester film in gochujang.

Polishing characteristics of polyetherketoneketone on Candida albicans adhesion (Polyetherketoneketone의 연마 특성이 Candida albicans의 부착에 미치는 영향)

  • Kim, Hyunyoung;Lee, Jonghyuk;Lee, Sung-Hoon;Baek, Dongheon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.207-216
    • /
    • 2020
  • Purpose: To compare the polishing characteristics and their influence on Candida albicans adhesion to the recently introduced polyetherketoneketone (PEKK) and the conventional polymethylmethacrylate (PMMA) denture resin material. Materials and methods: Specimens from PEKK (Group E) and PMMA (Group M) were made in dimensions of 8 mm in diameter and 2 mm in thickness. The specimens were further divided into sub-groups according to the extent of polishing (ER, MR: rough; EP, MP: polished, N = 12 each). The specimens were polished using polishing machine and SiC foil. ER and MR group specimens were polished with 600 grit SiC foil only. EP and MP groups were further polished with 800, 1,000, 1,200 grit SiC foils sequentially. To measure the surface roughness values (Sa) of specimens, atomic force microscope (AFM) was used and scanning electron microscope (SEM) observation under 1,000, and 20,000 magnifications was performed to investigate surface topography. The polished specimens were soaked in C. albicans suspension for 2 hours with shaking to promote adhesion. The attached C. albicans were detached from the surface with 10 times of pipetting. The suspension of detached C. albicans was performed by serial dilution to 103 times, and the diluted suspensions were inoculated on Sabouraud dextrose agar plates using spread plate method. After incubating the plate for 48 hours, colony forming unit (CFU)/plate of C. albicans was counted. Statistical analysis was performed using one-way ANOVA and Tukey HSD test to confirm significant difference between the groups (α=.05). Results: Average Sa value was significantly higher in MR group compared to other groups (P<.05), meaning that additional polishing steps reduced surface roughness effectively only in the PMMA specimens. There was no significant difference in Sa values between MP and EP groups. In SEM images, PEKK specimens showed numerous spikes of abraded material protruding from the surface and this phenomenon was more significant in EP group. The mean CFU/plate value was the highest in EP group and this was significant when it was compared to MP group (P<.05) which was the lowest. Conclusion: Polishing PEKK using serial SiC abrasive foil may result in higher adhesion of C. albicans. In clinic, this should be considered carefully.

Study of transmission of Candida albicans in denture by dental polishing lathe (의치에서 치과기공용 연마기를 통한 캔디다균의 전염성에 대한 연구)

  • Lee, Gi-Ho;Song, Young-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.3
    • /
    • pp.199-205
    • /
    • 2014
  • Purpose: The purpose of this study was to evaluate the transmission of candida in denture by dental polishing lathe. Materials and Methods: Maxillary complete dentures made from the same model were infected with Candida albicans. The infected dentures were polished by dental polishing lathe with sterile pumice and distilled water. And then sterile maxillary complete dentures were polished with same method. Polishing surface was wiped with a cotton swab and the sample was checked for Candida albicans. The polishing wheel at room temperature was checked for Candida albicans every 24 hours for 3 days. Results: A considerable number of Candida was found on the polished sterile dentures. And the Candida albicans in polishing wheel was detected at up to two days. Conclusion: An anti-infection measure is urgently needed when dental polishing lathe is used for denture polishing, because of the possibility of fungal infection.

Chemical Mechanical Polishing Characteristics of Mixed Abrasive Silica Slurry (MAS) by adding of Manganese oxide (MnO2) Abrasive (산화망간이 첨가된 혼합 연마제 실리카 슬러리의 산화막 CMP 특성)

  • Seo, Yong-Jin
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1175-1181
    • /
    • 2019
  • In this paper, we have studied the chemical mechanical polishing(CMP) characteristics of mixed abrasive silica slurry(MAS) retreated by adding of manganese oxide(MnO2) abrasives within 1:10 diluted silica slurry. A slurry designed for optimal performance should produce high removal rates, acceptable polishing selectivity with respect to the underlying layer, low surface defects after polishing, and good slurry stability. The polishing performances of MnO2 abrasive-added MAS are evaluated with respect to their particle size distribution, surface morphology, and CMP performances such as removal rate and non-uniformity. As an experimental result, we obtained the comparable slurry characteristics compared to original silica slurry in the view-point of high removal rate and low non-uniformity. Therefore, our proposed MnO2-MAS can be useful to save on the high cost of slurry consumption since we used a 1:10 diluted silica slurry.

Development of Grinding/Polishing Process for Microstructure Observation of Copper melted Beads (구리 용융흔 미세조직 관측을 위한 연마/미세연마 프로세스 개발)

  • Park, Jin-Young;Bang, Sun-Bae
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.108-116
    • /
    • 2018
  • A melted bead microstructure can be divided into a deformed and undeformed layer. Measurement errors occur in the presence of a deformed layer, which should be removed through grinding/polishing whilst preserving the original structure. This paper proposes a grinding/polishing process to analyze the microstructure of copper melted beads. For the removal of the deformed layer, the correlation between the abrasive type/size, the polishing time and polishing rate was analyzed and the thickness of the deformed layer was less than $1{\mu}m$. The results suggest a new grinding/polishing procedure: silicon carbide abrasive $15{\mu}m$ (SiC P1200) 2 min, and $10{\mu}m$ (SiC P2400) 1 min; and diamond abrasive $6{\mu}m$ 8 min, $3{\mu}m$ 6 min, $1{\mu}m$ 10 min, and $0.25{\mu}m$ 8 min. In addition, a method of increasing the sharpness of the microstructure by chemical polishing with $0.04{\mu}m$ colloidal silica for 3 min at the final stage is also proposed. The overall grinding/polishing time is 38 min, which is shorter than that of the conventional procedure.