• Title/Summary/Keyword: 연료봉

Search Result 193, Processing Time 0.027 seconds

The Investigation of Accidental Case for LNG Terminal (LNG 생산기지의 사고사례 조사)

  • Ma, Y.W.;Lee, S.R.;Yoon, K.B.
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.4 s.33
    • /
    • pp.47-51
    • /
    • 2006
  • Safety issues for LNG(Liquified Natural Gas) terminal or LNG tank involve various concerns such as production/transportation at cryogenic temperature of $-160^{\circ}C$, large volume of handling, flammability and explosion risk. Hence, in designing an LNG terminal rigid safety criteria and mandatory requirements are unavoidable. Since known cases of LNG related accident are very few, careful study and root cause analysis of them are very important and provide precious information to increase safety level of the LNG terminal. In this paper most key accident cases were gathered and analysed to understand fundamental safety issues of LNG terminal to prevent further accident.

  • PDF

Uncertainty Quantification of RELAP5/MOD3/KAERI on Reflood Peak Cladding Temperature (재관수 첨두 피복재 온도에 대한 RELAP5/MOD3/KAERI의 불확실성 정량화)

  • Park, Chan-Eok;Chung, Bub-Dong;Lee, Young-Jin;Lee, Guy-Hyung;Lee, Sang-Yong
    • Nuclear Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.389-400
    • /
    • 1994
  • The predictability of KAERI version of RELAP5/MOD3 on reflood peak cladding temperature during large break loss-of-coolant accident is assessed against 18 test runs in FLECHT SEASET test data. The associated uncertainty is statistically quantified. The selected test runs include a gravity feed test and several forced feed tests with wide range of the parameters such as flooding rate, system pressure, initial clad temperature, rod bundle power. The results show that the code under-predicts the peak cladding temperature by 7.56 K on average. The upper limit of the associated uncertainty at 95% confidence level is evaluated to be about 99 K, It including the bias due to the under-prediction.

  • PDF

Sloshing Reduction Characteristics to Baffle for Cylindrical Liquefied Fuel Tank subject to Dynamic Load (동하중을 받는 원통형 액화연료 탱크의 배플에 따른 슬로싱 저감 특성)

  • Koo, Jun-Hyo;Cho, Jin-Rae;Jeong, Weui-Bong;Kim, Dang-Ju
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.9
    • /
    • pp.950-959
    • /
    • 2009
  • Liquid fluctuation called sloshing within liquid-storage tank gives rise to the significant effect on the dynamic stability of tank. This liquid sloshing can be effectively suppressed by installing baffles within the tank, and the suppression effect depends strongly on the design parameters of baffle like the baffle configuration. The present study is concerned with the parametric evaluation of the sloshing suppression effect for the CNG-storage tank, a next generation liquefied fuel for vehicles, to the major design parameters of baffle, such as the baffle configuration, the installation angle and height, the hole size of baffle. The coupled FEM-FVM analysis was employed to effectively reflect the interaction between the interior liquid flow and the tank elastic deformation.

Vibration Simulation Using LuGre Friction Model for Cladding Tube Fretting Wear Analysis (피복관 프레팅마모 해석을 위한 LuGre 마찰모델 성능 고찰)

  • Park, Nam-Gyu;Kim, Jin-Seon;Kim, Joong-Jin;Kim, Jae-Ik
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.1
    • /
    • pp.55-62
    • /
    • 2016
  • Nuclear fuels are always exposed to hot temperature and high speed coolant flow during the reactor operation. Thus the fuel rod accompanies small amplitude vibration due to the turbulent flow. The random vibration causes friction between the fuel rod and the grid structure which provides the lateral supports. The friction is critical to the fuel rod fretting wear, and it degrades fuel performance when a severe wear is developed. LuGre friction model is introduced in the paper, and the performance was evaluated comparing to the classical Coulomb model. It is shown that the developed friction force considering the Coulomb friction is not enough to stop or delay the motion while the stick-slip can be simulated using LuGre friction model. Numerical solutions of the two dimensional spacer grid cell model with the modern friction are also reviewed, and it is discussed that the new friction model simulates well the nonlinear mechanism.

Vibration Analysis of Beam Supported by Springs Considering a Contact (접촉해석이 연계된 스프링 지지보의 진동해석)

  • 최명환;강홍석;송기남;윤경호;김형규
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1216-1221
    • /
    • 2002
  • The fuel rods in the pressurized water reactor are continuously supported by a spring system called a spacer grid which is one of the main structural components for the fuel rod cluster (fuel assembly). The fuel rods are vibrating within the reactor due to coolant flow. Since the vibration, what is called flow-induced vibration(FIV), can wear away the surface of the fuel rod, it is important to understand the vibration characteristics of it. In this paper, the vibration analyses and the tests for the dummy rods supported by New Doublet(ND) spacer grids are described. A new FE model which reflects the contact area between the rod and ND spacer grid spring is developed to replace the previous one by which a good agreement could not be obtained with the vibration test. The natural frequency and mode shape calculated by both the previous FE model and the new one are compared with those of experiment fur a single-spanned rod supported by two ND spacer grids. The results by the new model show good agreement to experiment as compared with the ones by previous model. In addition, the new FE model is applied to the vibration analysis fur the dummy rod of 2.19 m tall continuously supported by five ND spacer grids. It is also obtained that the analysis results by the new FE model well agree to experiment ones as the single-spanned rod.

  • PDF

Modal Analysis and Testing for a Middle Spacer Grid of a Nuclear Fuel Rod (핵 연료봉 중간 지지격자의 모달 해석 및 실험)

  • Ryu, Bong-Jo;Koo, Kyung-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1948-1952
    • /
    • 2012
  • The paper presents modal testing and analysis in order to obtain the dynamic characteristics of a middle spacer grids of a nuclear fuel rod. A spacer grid is one of the important structural elements supporting nuclear fuel rods. Such a fuel rod can be oscillated by its thermal expansion, neutron irradiation and etc. due to cooling water flow under the operation of a nuclear power plant. When the fuel rod vibrates, fretting wear due to repeated friction motion between the fuel rods and spacer grids can be occurred, and so the fuel rod is damaged. In this paper, through modal analysis and testing, natural frequencies and modes of a middle spacer grid were calculated, and the following conclusions were obtained. Firstly the numerical first-seven natural frequencies for spacer grids of a fuel rod having complicated structures have a small difference within 3.8% with experimental natural frequencies, and so the suitability of simulation results was verified. Secondly, experimental mode shapes for a middle spacer grid of a nuclear fuel rod were verified by obtaining lower non-diagonal terms through MAC(Modal Assurance Criteria), and were confirmed by the simulation modes.

Reflood Experiments with Horizontal and Vertical Flow Channels

  • Chung, Moon-Ki;Lee, Seung-Hyuck;Park, Choon-Kyung;Lee, Young-Whan
    • Nuclear Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.153-162
    • /
    • 1980
  • The investigation of the fuel cladding temperature behavior and heat transfer mechanism during the reflooding phase of a LOCA plays an important role in performance evaluation of ECCS and safety analysis of water reactors. Reflooding experiments were performed with horizontal and vertical flow channels to investigate the effect of coolant flow channel orientation on rewetting process. Emphasis was mainly placed on the CANDU reactor which has horizontal pressure tubes in core, and the results were compared with those of vertical channel. Also to investigate the rewetting process visually, the experiments by using a rod in annulus and a quartz tube heated outside were performed. It can be concluded that the rewetting velocity in horizontal flow channel is clearly affected by flow stratification, however, the average rewetting velocity is similar to those in vertical flow channel for same conditions.

  • PDF

영광 3호기 가연성흡수봉 종류에 따른 노심특성 분석

  • 최기용;이국종;이해찬;정선교
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.219-224
    • /
    • 1996
  • 노심설계에서 현재 사용되는 일체형 가연성 흡수봉인 Gd, ZrB$_2$ 그리고 Er의 한국표준형 원전 노심 설계에의 타당성을 노심 F$\Delta$H 제어, 저누출 장전모형 설계, 농축도/주기길이 그리고 주기말의 잔존 페널티 등의 측면에서 분석하였다. 초기노심의 경우는 영광 3호기 1주기 장전모형에 동일 연료집합체를 사용한 Gd/ZrB$_2$/Er의 경우와 ZrB$_2$/Er 최적장전모형에 동일 연료집합체를 사용한 경우에 대하여 분석하였다. 평형노심은 Gd/ZrB$_2$/Er 모두 동일한 장전모형을 사용한 18개월 주기길이의 노심에 대하여 동일한 농축도에서의 주기길이차이와 동등 주기길이를 내는데 필요한 농축도 요구량에 대하여 분석하였다. 초기노심 평형노심 모두 F$\Delta$H 제어에는 ZrB$_2$/Er가 Gd보다 유리하였으며, 저누출 장전모형의 설계에도 ZrB$_2$와 Er가 Gd보다 유리하였다. 평형노심에서 동일한 주기길이를 내는데 요구되는 농축도는 ZrB$_2$에 비하여 Er는 0.182 w/o Gd는 0.063 w/o 높게 나타났으며 동일 농축도를 사용할 경우 주기길이는 ZrB$_2$에 비하여 Gd는 165 MWD/MTU 그리고 Er은 575 MWD/MTU가 짧게 나타났다. 따라서, F$\Delta$H 제어와 저누출 장전모형은 설계에는 ZrB$_2$와 Er가 Gd보다 유리하였으나 Er의 경우 주기말에서의 잔존 페널티가 매우 크다는 단점이 있다.

  • PDF

A Study on the Application of Marine Emulsion Fuel for Tier 3 Regulation (Tier 3 규제 대응을 위한 선박용 에멀젼 연료 적용성 연구)

  • Lee, Ki-Bong;Kim, Moon-Chan;Park, Hea Kyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.10
    • /
    • pp.671-677
    • /
    • 2012
  • In this study, the characteristics of emulsified fuel and engine emissions were studied with an engine dynamometer. In the results of physical property analysis, the margin of error of net calorific value and gross calorific value was ${\pm}0.5%$, were almost same theoretical calculation and results of physical property analysis test. In emulsified fuel, density and viscosity increased with increasing water contents. Emulsified fuel which is composed of water and Bunker-A was manufactured by using homogenizer and ultrasonic generator in $80^{\circ}C$. Phase separation did not take place in $20^{\circ}C$ and $50^{\circ}C$. In the results of engine dynamometer test, NOx concentration and smoke density were reduced with increasing water contents in using emulsified fuel. Total NOx could be reduced by about 41%, 10%, 32% and 28% at 1,000 rpm, 1,200 rpm, 1,500 rpm and 2,500 rpm respectively. Total smoke density was reduced to 42%, 65%, 70%, 62%, and 82% at 1,000 rpm, 1,200 rpm, 1,500 rpm, 2,000 rpm, and 2,500 rpm respectively.

The Component Characteristics and the Distribution Channels for Forest Products Consumed as a Fuel in Kyeongseong City (Seoul) in 1929 (1929년 경성부(京城府)에서 소비(消費)된 임산연료(林産燃料)의 구성별(構成別) 특성(特性)과 유통(流通) 경로(經路))

  • Lee, Ki-Bong;Bae, Jae-Soo
    • Journal of Korean Society of Forest Science
    • /
    • v.94 no.3 s.160
    • /
    • pp.135-145
    • /
    • 2005
  • The purpose of this study is to reveal the component characteristics and the channels of distribution for forest products as a fuel that were consumed in Kyeongseong city (Seoul) in 1929, in the middle of the colonial period. The summary of the results are as follows; (1) though the average consumption of forest products consumed as a fuel per household in Kyeongseong city was slightly less than one-third as much forest products as fuel consumed in other counties of Kyeongki province, but due to the high heat capacity, the amount of fuelwood and charcoal consumption was much higher than leaf and grass consumption; (2) the largest supply areas of forest products for fuel were the riverside of Kangwon province and Kyeonggi province in which the waterways were available. They supplied 42.6% of total consumption, and the other supply areas were the northern part of Kyeonggi province, etc. (29.5%) where railroads were handy, and the suburbs of Kyeongseong City (27.9%) by roads; (3) the transportation areas using the Han River were divided into two parts of Ttook island (43.0%) and former Yongsan and Mapo (45.6%), but the volume of transportation by railroad was centralized in Kyeongseong Station, which accounted for 72.2% of total volume of transportation by rail; (4) the most of the forest products consumed for fuel in Kyeongseoung city were sold in temporary fuelwood markets, rather than permanent and regular markets.