Current Sensorless Three Phase PWM AC/DC Boost Converter with Unity Power Factor (전류센서리스 단위역률 3상 PWM AC/DC Boost 컨버터)

  • 천창근;김철우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.105-112
    • /
    • 2003
  • Diode rectifier which can't be controlled output voltage and phase control converter as AC/DC converter have low power factor and harmonics of lower order in the line current. In this paper, three phase PWM(Pulse Width Modulation) AC/DC boost converter is studied to solve these problems. The characteristics of a proposed converter are to control the phase of current without current sensor as a very simple control algorithm using circuit parameters only and to apply sinusoidal PWM method with fixed switching frequency due to a difficult design of input filter and switching device. We simulate for the proposed algorithm that high power factor is achieved and DC link voltage has fast dynamic response without ripple in rectifying and regenerating operation. As a result of experiment with circuit parameter(inductor, capacitor) decided in simulation, the proposed converter had high power factor and reduction of low order harmonics as against diode rectifier.

Development of Self Oscillating Electronic Ballast for Fluorescent Lamp Using SEPIC Converter (SEPIC 컨버터를 이용한 형광등용 자려 발진형 전자식 안정기 개발)

  • 김왕식;한재현;조계현;박종연
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.20-25
    • /
    • 2003
  • This paper presents the PFC method for an electronic ballast using SEPIC converter. Generally, the Boost Converter Type PFC has a DC 400V and output voltage is a bigger than input rms voltage. But the SEPIC type converter has above 0.95 Power Factor and wanted output voltage. This paper employs the SEPIC(Single Ended Primary Inductance Converter) Converter for PFC and the Ring core for oscillating method. Consequently, We reduced element's size and capacity in a converter with minimum voltage for the operating lamp.

A Study on Determination of Appropriate Load Power Factor Considering Greenhouse Gas Emission (온실가스 배출량을 고려한 적정 부하역률 개선 연구)

  • Hwang, Sung-Ho;Lee, Byung-Ha
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.288-289
    • /
    • 2011
  • 최근 대두되고 있는 중요한 문제 중 하나인 기후변화협약에 의하여 온실가스 배출량에 대한 감축 및 규제가 실시되고 있으므로, 우리나라에서도 이에 대한 대비를 하지 않으면 안 되며, 유가가 급등하고 있어 에너지 소비를 감소시키는 정책을 적극적으로 수행해 나가야 한다. 전력시스템이 대형화되고 더욱 복잡하게 구성되면서, 전력손실 감소 및 전압관리 차원에서 부하 역률 관리의 중요성이 새롭게 부각되고 있다. 따라서 온실가스 배출량 감축 효과를 반영하여 우리나라의 전력시스템의 적정한 부하역률 기준치가 새롭게 조정될 필요가 있다. 본 논문에서는 온실가스 배출량 감축 효과를 반영하기 위한 기초연구로서 적정 부하역률을 산정하기위한 기법을 제시하고, 이산화탄소의 배출량 감축 효과를 반영하지 않을 때와 반영할 때의 적정 부하역률이 어떻게 변화하는지를 주어진 하나의 전력 시스템을 사용하여 분석한다.

  • PDF

Development of advanced Power Factor Computation Algorithm in Harmonics distorted Distribution System (고조파 왜곡 환경에서 향상된 역률 계측 알고리즘 개발)

  • Lee, Hyun-woo;Park, Young-kyun;Lee, Jinhan;Joung, Sanghyun;Park, Chul-woo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.7
    • /
    • pp.121-127
    • /
    • 2016
  • We propose a algorithm to calculate power factor of fundamental waveform in an environment where the voltage and current have been distorted by harmonics. In the proposed power factor computation algorithm, voltage and current are converted to rotating DQ reference frame, and power factor is calculated from active power and reactive power. We compare the proposed method with the conventional power factor measurement method as mathematically. In a condition that voltage and current are distorted by harmonics, the proposed method accurately measure the power factor of fundamental wave, and it is confirmed by simulation using MATLAB. If the proposed power factor measurement method is applied to an automatic power factor control system, a power factor compensation performance can be maximized in harmonic distortion environment. As a result, it is possible to reduce electricity prices, reduce line loss, increase load capacity, ensure the transmission margin capacity, and reduce the amount of power generation.

Ozone Generating Power Supply with High Power Factor (고역률 오존발생기 전원공급장치 연구)

  • An, Hyunsung;Shin, Changhoon;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.169-170
    • /
    • 2014
  • 본 논문에서는 높은 역률을 가지는 PFC(Power Factor Correction) 컨버터와 높은 고주파 전압을 발생시키는 단상 하프브리지 인버터를 채용한 오존발생기를 소개한다. PFC 컨버터를 채용하여 기존의 오존발생기용 전원장치에 비해 입력 역률, 전원공급체계와 보호 장치를 개선하였으며, 3kW급의 프로토타입을 구현하고 시뮬레이션 및 실험을 통하여 전원장치의 안정성 및 입력에 대한 높은 역률(0.99이상)을 확인하였다.

  • PDF

Input Current Ripple Improvement on Interleaved Boost Power Factor Corrector Operating in Discontinuous Current Mode (불연속 전류모드로 동작하는 Interleaved 승압형 역률보상 컨버터의 입력전류 리플개선)

  • 허태원;박지호;노태균;김동완;박한석;우정인
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.1
    • /
    • pp.116-123
    • /
    • 2003
  • In this paper, interleaved boost converter is applied as a pre-regulator in switched mode power supply. The pre-regulator plays a role to improve power factor. Interleaved Boost Power Factor Corrector(IBPFC) can reduce input current ripple as a single voltage control loop only without inner current loop, because input current is divided each 50% by two switching devices. Each converter cell is also operated in discontinuous current mode and inductor current of each converter is discontinuous. Total input current which is composed by each converter cell is continuous current. Thus, IBPFC is able to improve input current ripple. IBPFC operating in discontinuous current mode can be classified as six modes from switching state and be carried out state space averaging small signal modeling. A control transfer function is obtained according to the modeling. Single voltage control loop is also constructed by the control transfer function. From experimental result, improvement of power factor and input current ripple are verified.

High-Power-Factor High Frequency Resonant LED Driver with Single-Stage (단일전력단을 갖는 고역율 고주파 공진형 LED 구동회로)

  • Jo, Hyeon-Cheol;Seo, Cheol-Sik;Kim, Dong-Hui
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.95-96
    • /
    • 2012
  • 본 논문에서는 조명용 LED 구동 장치를 위한 새로운 방식의 단일전력단을 갖는 LED 구동회로를 제안한다. 제안 회로는 임계모드에서 동작하는 부스트 컨버터를 역률 개선 회로로 사용하였고, LED 구동회로로 LLC 고주파 공진 회로를 채택하였다. 또한, 기존의 역률 개선 회로와 LED 구동회로의 2단 회로를 단일전력단을 갖는 회로로 구성함으로 고역률, 고효율, 경량 및 소형의 LED 구동회로를 구성하였다. 본 논문에서는 제안한 회로의 동작 원리를 설명하였고, 시뮬레이션과 실험을 통하여 제안 회로의 타당성을 입증하였다.

  • PDF

산업공장의 전력계통분석

  • 홍순경
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • no.10 s.202
    • /
    • pp.27-36
    • /
    • 1993
  • 전력계통의 분석은 첫 번째로 특수조건하에서 기존 또는 계획된 전력계통의 성능을 예측 하거나 개선하는데 사용되는 기술로서, 이 기술을 산업체의 전력계통에 적용할 때 안정성, 신뢰성, 고품질의 전력 그리고 초기투자와 운전비의 절감과 같은 전력계통 설계의 목적을 달성 하는데 크게 공헌하게 된다. 산업체의 전력계통 분석은 주로 단락사고, 보호설비의 협조, 전력조류, 전동기의 기동, 접지, 과도적 과전압, 역률개선, 기타의 설계 등을 위한 계산이 포함된다. 전력계통 분석은 전력계통을 신설 또는 개조할 때는 물론이고 기존시설의 부하나 용량이 현저하게 변경되었을 때 또는 기존시설의 고장을 진단할 때에 반드시 실행되어야한다.

  • PDF

Development of Voltage Controlled Power Factor Compensation System using Slidac (슬라이닥을 이용하는 전압 제어 방식의 역률보상시스템 개발)

  • Joung, Sanghyun;Lee, Hyun-woo;Park, Young-kyun;Park, Chul-woo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.8
    • /
    • pp.115-122
    • /
    • 2017
  • In this paper, we propose a novel power factor compensation system using slidac. The proposed power factor compensation system compensates the power factor by adjusting the output voltage of the slidac. In the conventional power factor compensation system using capacitor bank method, the power factor compensation error occurs depending on the load condition due to the limitation of the compensation capacitor capacity. However, the proposed system can finely change slidac output voltage applied to the capacitor, therefore power factor can be compensated up to 100% without error. We compare the proposed system with the conventional system, and confirm that the proposed system has excellent power factor compensation performance through simulations and experiments. If the proposed power factor compensation system is applied to an industrial field, a power factor compensation performance can be maximized. As a result, it is possible to reduce of electricity prices, reduce of line loss, increase of load capacity, ensure the transmission margin capacity, and reduce the amount of power generation.

전력용 콘덴서의 점검과 그 대책

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • no.7 s.127
    • /
    • pp.90-95
    • /
    • 1987
  • 전력용 콘덴서의 설치에 의한 역률개선은 효과가 크므로 조건만 갖추어지면 적극적으로 설치하는 경향이 있다. 장점과 단점은 등을 맞대고 있으며 전력용 콘덴서도 그 예에서 벗어나지 못하여 많은 효과(특징)에 대하여 콘덴서이기 때문에 숙명적인 단점도 몇가지를 안고 있다. 전기사용의 합리화에 있어서는 이 단점을 잘 커버하여 운영해야 되며 그럼으로써 참뜻의 합리화를 달성했다고 할 수 있겠다. 여기서 전력용 콘덴서의 단점과 그 대책을 중심으로 해설한다.

  • PDF